GaAs Broadband SPDT Switch
DC - 6.0 GHz
MASWSS0202
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.
V1
2
RoHS
Compliant
Electrical Specifications: TA = 25°C, Z0 = 50 Ω, Vc = 0 V/ 3 V, 8 pF Capacitor 3
3. For positive voltage control, external DC blocking capacitors are required on all RF ports.
4. Insertion loss can be optimized by varying the DC blocking capacitor value.
Parameter Test Conditions Units Min. Typ. Max.
Insertion Loss 4 2 - 3 GHz
3 - 4 GHz
4 - 5 GHz
5 - 6 GHz
dB
dB
dB
dB
—
—
—
—
0.55
0.55
0.65
0.75
0.9
0.9
1.0
1.1
Isolation 2 - 6 GHz dB 22 25 —
Return Loss DC - 6 GHz dB — 20 —
IIP2 Two Tone, +5 dBm / Tone, 5 MHz Spacing
VC = 0.0 V/3 V @ 2.4 GHz
VC = 0.0 V/3 V @ 5.8 GHz
VC = 0.0 V/5 V @ 2.4 GHz
VC = 0.0 V/5 V @ 5.8 GHz
dBm
dBm
dBm
dBm
—
—
—
—
91
81
99
91
—
—
—
—
IIP3 Two Tone, +5 dBm / Tone, 5 MHz Spacing
VC = 0.0 V/3 V @ 2.4 GHz
VC = 0.0 V/3 V @ 5.8 GHz
VC = 0.0 V/5 V @ 2.4 GHz
VC = 0.0 V/5 V @ 5.8 GHz
dBm
dBm
dBm
dBm
—
—
—
—
52
50
53
51
—
—
—
—
Input P-1dB VC = 0.0 V/3 V @ 2.4 GHz
VC = 0.0 V/3 V @ 5.8 GHz
VC = 0.0 V/5 V @ 2.4 GHz
VC = 0.0 V/5 V @ 5.8 GHz
dBm
dBm
dBm
dBm
—
—
—
—
32
29
37
35
—
—
—
—
2nd Harmonic 2.4 GHz, PIN = +20 dBm
5.3 GHz, PIN = +20 dBm
5.8 GHz, PIN = +20 dBm
dBc
dBc
dBc
—
—
—
-88
-91
-77
—
—
—
3rd Harmonic 2.4 GHz, PIN = +20 dBm
5.3 GHz, PIN = +20 dBm
5.8 GHz, PIN = +20 dBm
dBc
dBc
dBc
—
—
—
-87
-81
-85
—
—
—
T-rise, T-fall 10% to 90% RF and 90% to 10% RF nS — 13 —
Ton, Toff 50% control to 90% RF, 50% control to 10% RF nS — 35 —
Transients — mV — 14 —
Control Current |VC| = 3 V µA — 10 25
Truth Table 5
Control V1 Control V2 RFC– RF1 RFC—RF2
1 0 On Off
0 1 Off On
5. 1 = +2.9 V to +5 V, 0 = 0 V + 0.2 V.
Absolute Maximum Ratings 6,7
Parameter Absolute
Maximum
Input Power @ 3 V Control +32 dBm
Input Power @ 5 V Control +34 dBm
Operating Voltage +8.5 volts
Operating Temperature -40°C to +85°C
Storage Temperature -65°C to +150°C
6. Exceeding any one or combination of these limits may cause
permanent damage to this device.
7. M/A-COM does not recommend sustained operation near
these survivability limits.