Family of Affordable
Basic System DC
Power Supplies
The Agilent Technologies N8700 series
system DC power supplies give you
just the right performance — at just
the right price — in a compact (2 U)
package. This family of affordable
3300 W and 5000 W single-output
programmable DC power supplies
consists of 21 models for simple
DC power applications.
They provide stable output power,
built-in voltage and current measure-
ment, and output voltage and current
from 8 V to 600 V and 5.5 A to 400 A.
These economical supplies offer many
system-ready features like multiple
standard I/O interfaces to simplify
and accelerate test-system develop-
ment for R&D, design validation,
and manufacturing engineers in the
aerospace/defense, automotive,
component and communications
industries.
Small, high-density package
saves you rack space
The N8700 provides up to 5200 W in
a small space-saving 2 U-high, 19-
inch-wide package. Its air vents are
in the front and rear (not on the top
or bottom), so you can stack other
instruments directly above or below it
to save valuable rack space.
Agilent N8700 Series
System DC Power Supplies
Models: N8731A-42A (3.3 kW), N8754A-62A (5 kW)
Data Sheet
21 Models: 3300 W and 5000 W output power
Up to 600 V and up to 400 A
Small, high density 2 U package
Built-in voltage and current measurement
Full protection from over-voltage and over-current
Flexible AC input voltage options
LAN, USB, and GPIB interfaces standard
Fully compliant to LXI Class C specification
®
Easy front-panel operation
You can quickly and easily operate
the power supply with its rotary
knobs and buttons. Using the front-
panel controls, you can make coarse
or fine adjustments of output voltage
and current, protection settings, and
set power-on states (last setting
memory or factory default setting).
The output voltage and current are
displayed simultaneously, and LED
indicators show power supply status
and operating modes. You can lock
the front panel controls to protect
against accidental power-supply
parameter changes.
Extensive device protection
To safeguard your device from
damage, the N8700 Series power
supplies provide over-temperature,
over-current and over-voltage protec-
tion (OVP) to shut down the power
supply output when a fault condition
occurs. They also offer an under-
voltage limit (UVL) that prevents
adjustment of the output voltage
below a certain limit. The combina-
tion of UVL and OVP capabilities
lets you create a protection window
for sensitive load circuitry.
Simplify system connections
The N8700 Series power supplies
comes standard with GPIB,
Ethernet/LAN, and USB 2.0
interfaces giving you the flexibility
to use your I/O interface of choice
today and safeguard your test setup
for the future. The N8700 is fully
compliant with the LXI Class C
specification.
2
Figure 1. Front panel control knobs and buttons make the N8700 easy to use
in a system and on the bench
Figure 2. The N8700's standard LAN (LXI C), USB 2.0 and GPIB interfaces enable simple
system connections
Remote access and control
The built-in Web server provides
remote access and control of the
instrument via a standard browser
such as Microsoft® Internet
Explorer or Mozilla Firefox®. This
control goes above and beyond the
LXI specification, giving user's the
ability to monitor and control the
instrument from anywhere. Using
the Web browser, you can set up,
monitor and operate the N8700
remotely.
Easy system integration
and confi guration
To simplify system development,
the N8700 comes standard with
IVI-COM drivers. The N8700
supports the easy-to-use SCPI
(Standard Commands for
Programmable Instruments).
Flexible confi guration:
connect multiple units in
parallel or series
Should you need greater output
power, the N8700 series power
supplies give you the flexibility to
connect in parallel up to four identi-
cal units (same model number) for
greater output current or connect
two identical units (same model
number) in series for greater output
voltage (see output terminal isola-
tion information).
Analog programming
and monitoring
The output voltage and current can
be programmed from zero to full
scale by either an analog voltage
0 to 5 V or 0 to 10 V or by resistance
of 0 to 5 kΩ or 0 to 10 kΩ.
Flexible AC input
voltage options
The N8700 models offer flexible AC
input voltage options. Every N8700
model can be purchased with either
a 208 V 3-phase or 400 V 3-phase
voltage input option. The 3.3 kW
models have the additional option
of a 230 V single-phase AC input
voltage. Choose the one that best
fits your operating environment. They
also provide power factor correction.
Please choose carefully the AC input
voltage option for your N8700 power
supply. The AC input voltage cannot
be changed without returning the
unit to Agilent and placing a new order.
Rack mounting
The rack mount ears and handles
are provided standard with every
unit. In addition, the N5740A rack
mount slide kit makes it easy to
integrate an N8700 into a test rack by
providing all the necessary hardware
to rack mount an N8700 series power
supply in only 2 U of rack space. The
N5740A rack mount slide kit is the
same kit used with the N5700 series.
3
Figure 3. N8700 series web graphical user interface for remote access and control
of the power supply
4
Performance Specifi cations
Notes:
1. Minimum voltage is guaranteed to maximum 0.2% of rated output voltage.
2. Minimum current is guaranteed to maximum 0.4% of rated output current.
3. 20 MHz
4. 5 Hz - 1 MHz
5. From no-load to full-load, constant input voltage. Maximum drop in remote sense.
6. For load voltage change equal to the unit voltage rating, constant input voltage
7. Single-phase and 3-Phase 208 V models: 170~265 VAC, constant load. 3-Phase 400 V models: 342~460 VAC, constant load.
8. The constant current programming readback and monitoring accuracy does not include the warm-up and load regulation thermal drift.
9. Time for output voltage to recover within 0.5% of its rated output for a load change 10 - 90% of rated output current, local sense.
N8731A N8732A N8733A N8734A N8735A N8736A
DC output ratings
Voltage 18 V 10 V 15 V 20 V 30 V 40 V
Current 2400 A 330 A 220 A 165 A 110 A 85 A
Power 3200 W 3300 W 3300 W 3300 W 3300 W 3400 W
Output ripple and noise
CV p-p 360 mV 60 mV 60 mV 60 mV 60 mV 60 mV
CV rms 4 8 mV 8 mV 8 mV 8 mV 8 mV 8 mV
Load effect
CV load regulation 56.2 mV 6.5 mV 7.25 mV 8 mV 9.5 mV 11 mV
CC load regulation 685 mA 71 mA 49 mA 38 mA 27 mA 22 mA
Source effect
CV line regulation 7
2.8 mV 3 mV 3.5 mV 4 mV 5 mV 6 mV
CC line regulation 742 mA 35 mA 24 mA 18.5 mA 13 mA 10.5 mA
Programming accuracy
Voltage 1 0.05% + 4 mV 5 mV 7.5 mV 10 mV 15 mV 20 mV
Current 2, 8 0.1% + 800 mA 660 mA 440 mA 330 mA 220 mA 170 mA
Measurement accuracy
Voltage 0.1% + 8 mV 10 mV 15 mV 20 mV 30 mV 40 mV
Current 8 0.1% + 1200 mA 990 mA 660 mA 495 mA 330 mA 255 mA
Load transient recovery time
Time 9<1 ms <1 ms <1 ms <1 ms <1 ms <1 ms
5
Performance Specifi cations (Continued)
Notes:
1. Minimum voltage is guaranteed to maximum 0.2% of rated output voltage.
2. Minimum current is guaranteed to maximum 0.4% of rated output current.
3. 20 MHz
4. 5 Hz - 1 MHz
5. From no-load to full-load, constant input voltage. Maximum drop in remote sense.
6. For load voltage change equal to the unit voltage rating, constant input voltage
7. Single-phase and 3-Phase 208 V models: 170~265 VAC, constant load. 3-Phase 400 V models: 342~460 VAC, constant load.
8. The constant current programming readback and monitoring accuracy does not include the warm-up and load regulation thermal drift.
9. Time for output voltage to recover within 0.5% of its rated output for a load change 10 - 90% of rated output current, local sense.
N8737A N8738A N8739A N8740A N8741A N8742A
DC output ratings
Voltage 160 V 80 V 100 V 150 V 300 V 600 V
Current 255 A 42 A 33 A 22 A 11 A 5.5 A
Power 3300 W 3360 W 3300 W 3300 W 3300 W 3300 W
Output ripple and noise
CV p-p 360 mV 80 mV 100 mV 100 mV 300 mV 500 mV
CV rms 4 8 mV 25 mV 25 mV 25 mV 100 mV 120 mV
Load effect
CV load regulation 514 mV 17 mV 20 mV 27.5 mV 50 mV 95 mV
CC load regulation 616 mA 13.4 mA 11.6 mA 9.4 mA 7.2 mA 6.1 mA
Source effect
CV line regulation 7
8 mV 10 mV 12 mV 17 mV 32 mV 62 mV
CC line regulation 77.5 mA 6.2 mA 5.3 mA 4.2 mA 3.1 mA 2.6 mA
Programming accuracy
Voltage 1 0.05% + 30 mV 40 mV 50 mV 75 mV 150 mV 300 mV
Current 2, 8 0.1% + 110 mA 84 mA 66 mA 44 mA 22 mA 11 mA
Measurement accuracy
Voltage 0.1% + 60 mV 80 mV 100 mV 150 mV 300 mV 600 mV
Current 8 0.1% + 165 mA 126 mA 99 mA 66 mA 33 mA 16.5 mA
Load transient recovery time
Time
9
<1 ms <1 ms <1 ms <2 ms <2 ms <2 ms
6
Supplemental Characteristics
Notes:
10. From 10% to 90% or 90% to 10% of rated output voltage, with rated, resistive load.
11. From 90% to 10% of rated output voltage.
12. For 8 V - 15 V models the ripple is measured from 2 V to rated output voltage and rated output current. For other models, the ripple is measured at
10 - 100% of rated output voltage and rated output current.
N8731A N8732A N8733A N8734A N8735A N8736A
Output response time
Up-prog response time 10 80 ms 80 ms 80 ms 80 ms 80 ms 80 ms
Down-prog response time
Full-load 10 20 ms 100 ms 100 ms 100 ms 160 ms 160 ms
Down-prog response time
No-load 11 500 ms 600 ms 700 ms 800 ms 900 ms 1000 ms
Command response time
100 ms
(typical)
100 ms
(typical)
100 ms
(typical)
100 ms
(typical)
100 ms
(typical)
100 ms
(typical)
Remote sense compensation
2 V 2 V 2 V 2 V 5 V 5 V
Over-voltage protection
Range
0.5-10 V 0.5-12 V 1-18 V 1-24 V 2-36 V 2-44 V
Output ripple and noise
CC rms 12 1300 mA 1200 mA 880 mA 660 mA 300 mA 200 mA
Programming resolution
Measurement resolution
Voltage 0.96 mV 1.2 mV 1.8 mV 2.4 mV 3.6 mV 4.8 mV
Current 48 mA 39.6 mA 26.4 mA 19.8 mA 13.2 mA 10.2 mA
Front panel display accuracy
(4 digits; ± 1 count)
Voltage 40 mV 50 mV 75 mV 100 mV 150 mV 200 mV
Current 2000 mA 1650 mA 1100 mA 825 mA 550 mA 425 mA
Temperature stability
Voltage 4 mV 5 mV 7.5 mV 10 mV 15 mV 20 mV
Current 200 mA 165 mA 110 mA 82.5 mA 55 mA 42.5 mA
Temperature coeffi cient
Voltage from rated output voltage 100 PPM/°C 100 PPM/°C 100 PPM/°C 100 PPM/°C 100 PPM/°C 100 PPM/°C
Current from rated output current 200 PPM/°C 200 PPM/°C 200 PPM/°C 200 PPM/°C 200 PPM/°C 200 PPM/°C
(add this to the output response time to obtain the total programming time)
(over 8 hours, after a 30 minute warm-up, with constant line, load, and temperature)
(after a 30 minute warm-up)
7
Notes:
10. From 10% to 90% or 90% to 10% of rated output voltage, with rated, resistive load.
11. From 90% to 10% of rated output voltage.
12. For 8 V - 15 V models the ripple is measured from 2 V to rated output voltage and rated output current. For other models, the ripple is measured at
10 - 100% of rated output voltage and rated output current.
Supplemental Characteristics (Continued)
N8737A N8738A N8739A N8740A N8741A N8742A
Output response time
Up-prog response time 10 150 ms 150 ms 150 ms 150 ms 150 ms 250 ms
Down-prog response time
Full-load 10 160 ms 300 ms 300 ms 300 ms 300 ms 500 ms
Down-prog response time
No-load 11 1100 ms 1200 ms 1500 ms 2000 ms 3500 ms 4000 ms
Command response time
100 ms
(typical)
100 ms
(typical)
100 ms
(typical)
100 ms
(typical)
100 ms
(typical)
100 ms
(typical)
Remote sense compensation
5 V 5 V 5 V 5 V 5 V 5 V
Over-voltage protection
Range
5-66 V 5-88 V 5-110 V 5-165 V 5-330 V 5-660 V
Output ripple and noise
CC rms 12 100 mA 80 mA 70 mA 60 mA 20 mA 10 mA
Programming resolution
Measurement resolution
Voltage 7.2 mV 9.6 mV 12 mV 18 mV 36 mV 72 mV
Current 6.6 mA 5 mA 4 mA 2.6 mA 1.3 mA 0.66 mA
Front panel display accuracy
(4 digits; ± 1 count)
Voltage 300 mV400 mV500 mV750 mV1500 mV3000 mV
Current 275 mA 210 mA 165 mA 110 mA 55 mA 27.5 mA
Temperature stability
Voltage 30 mV 40 mV 50 mV 75 mV 150 mV 300 mV
Current 27.5 mA 21 mA 16.5 mA 11 mA 5.5 mA 2.8 mA
Temperature coeffi cient
Voltage from rated output voltage 100 PPM/°C 100 PPM/°C 100 PPM/°C 100 PPM/°C 100 PPM/°C 100 PPM/°C
Current from rated output current 200 PPM/°C 200 PPM/°C 200 PPM/°C 200 PPM/°C 200 PPM/°C 200 PPM/°C
(after a 30 minute warm-up)
(add this to the output response time to obtain the total programming time)
(over 8 hours, after a 30 minute warm-up, with constant line, load, and temperature)
8
Performance Specifi cations
Notes:
1. Minimum voltage is guaranteed to maximum 0.2% of rated output voltage.
2. Minimum current is guaranteed to maximum 0.4% of rated output current.
3. 20 MHz
4. 5 Hz - 1 MHz
5. From no-load to full-load, constant input voltage. Maximum drop in remote sense.
6. For load voltage change equal to the unit voltage rating, constant input voltage
7. Single-phase and 3-Phase 208 V models: 170~265 VAC, constant load. 3-Phase 400 V models: 342~460 VAC, constant load.
8. The constant current programming readback and monitoring accuracy does not include the warm-up and load regulation thermal drift.
9. Time for output voltage to recover within 0.5% of its rated output for a load change 10 - 90% of rated output current, local sense.
N8754A N8755A N8756A N8757A N8758A
DC output ratings
Voltage 120 V 30 V 40 V 60 V 80 V
Current 2250 A 170 A 125 A 85 A 65 A
Power 5000 W 5100 W 5000 W 5100 W 5200 W
Output ripple and noise
CV p-p 375 mV 75 mV 75 mV 75 mV 100 mV
CV rms 4 10 mV 10 mV 10 mV 10 mV 15 mV
Load effect
CV load regulation 58 mV 9.5 mV 11 mV 14 mV 17 mV
CC load regulation 6250 mA 170 mA 125 mA 85 mA 65 mA
Source effect
CV line regulation 7
2 mV 3 mV 4 mV 6 mV 8 mV
CC line regulation 7125 mA 85 mA 62.5 mA 42.5 mA 32.5 mA
Programming accuracy
Voltage 1 0.025% + 15 mV 22.5 mV 30 mV 45 mV 60 mV
Current 2, 8 0.1% + 750 mA 510 mA 375 mA 255 mA 195 mA
Measurement accuracy
Voltage 0.025% + 25 mV 37.5 mV 50 mV 75 mV 100 mV
Current 8 0.1% + 750 mA 510 mA 375 mA 255 mA 195 mA
Load transient recovery time
Time
9
<1 ms <1 ms <1 ms <1 ms <1 ms
9
Performance Specifi cations
Notes:
1. Minimum voltage is guaranteed to maximum 0.2% of rated output voltage.
2. Minimum current is guaranteed to maximum 0.4% of rated output current.
3. 20 MHz
4. 5 Hz - 1 MHz
5. From no-load to full-load, constant input voltage. Maximum drop in remote sense.
6. For load voltage change equal to the unit voltage rating, constant input voltage
7. Single-phase and 3-Phase 208 V models: 170~265 VAC, constant load. 3-Phase 400 V models: 342~460 VAC, constant load.
8. The constant current programming readback and monitoring accuracy does not include the warm-up and load regulation thermal drift.
9. Time for output voltage to recover within 0.5% of its rated output for a load change 10 - 90% of rated output current, local sense.
N8759A N8760A N8761A N8762A
DC output ratings
Voltage 1100 V 150 V 300 V 600 V
Current 250 A 34 A 17 A 8.5 A
Power 5000 W 5100 W 5100 W 5100 W
Output ripple and noise
CV p-p 3100 mV 120 mV 300 mV 500 mV
CV rms 4 15 mV 25 mV 60 mV 120 mV
Load effect
CV load regulation 520 mV 27.5 mV 50 mV 95 mV
CC load regulation 650 mA 34 mA 17 mA 8.5 mA
Source effect
CV line regulation 7
10 mV 15 mV 30 mV 60 mV
CC line regulation 725 mA 17 mA 8.5 mA 4.3 mA
Programming accuracy
Voltage 1 0.025% + 75 mV 112.5 mV 225 mV 450 mV
Current 2, 8 0.1% + 150 mA 102 mA 51 mA 25.5 mA
Measurement accuracy
Voltage 0.025% + 125 mV 187.5 mV 375 mV 750 mV
Current 8 0.1% +
150 mA 102 mA 51 mA 25.5 mA
Load transient recovery time
Time
9
<1 ms <2 ms <2 ms <2 ms
10
Supplemental Characteristics
Notes:
10. From 10% to 90% or 90% to 10% of rated output voltage, with rated, resistive load.
11. From 90% to 10% of rated output voltage.
12. For 8 V - 15 V models the ripple is measured from 2 V to rated output voltage and rated output current. For other models, the ripple is measured at
10 - 100% of rated output voltage and rated output current.
N8754A N8755A N8756A N8757A N8758A
Output response time
Up-prog response time 10 30 ms 30 ms 30 ms 50 ms 50 ms
Down-prog response time
Full-load 10 50 ms 80 ms 80 ms 80 ms 100 ms
Down-prog response time
No-load 11 700 ms 800 ms 900 ms 1000 ms 1200 ms
Command response time
100 ms
(typical)
100 ms
(typical)
100 ms
(typical)
100 ms
(typical)
100 ms
(typical)
Remote sense compensation
2 V5 V5 V5 V5 V
Over-voltage protection
Range
1-24 V 2-36 V 2-44 V 5-66 V 5-88 V
Output ripple and noise
CC rms 12 1000 mA 460 mA 300 mA 150 mA 120 mA
Programming resolution
Measurement resolution
Voltage 2.4 mV 3.6 mV 4.8 mV 7.2 mV 9.6 mV
Current 30 mA 20.4 mA 15 mA 10.2 mA 7.8 mA
Front panel display accuracy
(4 digits; ± 1 count)
Voltage 100 mV 150 mV 200 mV 300 mV 400 mV
Current 1250 mA 850 mA 625 mA 425 mA 325 mA
Temperature stability
Voltage 10 mV 15 mV 20 mV 30 mV 40 mV
Current 125 mA 85 mA 62.5 mA 42.5 mA 32.5 mA
Temperature coeffi cient
Voltage from rated output voltage 100 PPM/°C 100 PPM/°C 100 PPM/°C 100 PPM/°C 100 PPM/°C
Current from rated output current 100 PPM/°C 100 PPM/°C 100 PPM/°C 100 PPM/°C 100 PPM/°C
(add this to the output response time to obtain the total programming time)
(over 8 hours, after a 30 minute warm-up, with constant line, load, and temperature)
(after a 30 minute warm-up)
11
Notes:
10. From 10% to 90% or 90% to 10% of rated output voltage, with rated, resistive load.
11. From 90% to 10% of rated output voltage.
12. For 8 V - 15 V models the ripple is measured from 2 V to rated output voltage and rated output current. For other models, the ripple is measured at
10 - 100% of rated output voltage and rated output current.
Supplemental Characteristics (Continued)
N8759A N8760A N8761A N8762A
Output response time
Up-prog response time 10 50 ms 50 ms 50 ms 100 ms
Down-prog response time
Full-load 10 100 ms 100 ms 100 ms 200 ms
Down-prog response time
No-load 11 1500 ms 2000 ms 2500 ms 3000 ms
Command response time
100 ms
(typical)
100 ms
(typical)
100 ms
(typical)
100 ms
(typical)
Remote sense compensation
5 V5 V5 V5 V
Over-voltage protection
Range
5-110 V 5-165 V 5-330 V 5-660 V
Output ripple and noise
CC rms 12 100 mA 90 mA 30 mA 15 mA
Programming resolution
Measurement resolution
Voltage 12 mV 18 mV 36 mV 72 mV
Current 6 mA 4.1 mA 2 mA 1 mA
Front panel display accuracy
(4 digits; ± 1 count)
Voltage 500 mV 750 mV 1500 mV 3000 mV
Current 250 mA 170 mA 85 mA 42.5 mA
Temperature stability
Voltage 50 mV 75 mV 150 mV 300 mV
Current 25 mA 17 mA 8.5 mA 4.3 mA
Temperature coeffi cient
Voltage from rated output voltage 100 PPM/°C 100 PPM/°C 100 PPM/°C 100 PPM/°C
Current from rated output current 100 PPM/°C 100 PPM/°C 100 PPM/°C 100 PPM/°C
(add this to the output response time to obtain the total programming time)
(over 8 hours, after a 30 minute warm-up, with constant line, load, and temperature)
(after a 30 minute warm-up)
12
Supplemental Characteristics (Continued)
Notes:
8. The constant current programming readback and monitoring accuracy does not include the warm-up and load regulation thermal drift.
Analog programming and monitoring
Vout voltage programming 0-100%, 0-5 V or 0-10 V, user selectable. Accuracy and linearity: ±0.5% of rated Vout.
Iout voltage programming 80-100%, 0-5 V or 0-10 V, user selectable. Accuracy and linearity: ±1% of rated Iout.
Vout resistor programming 0-100%, 0-5/10 Kohm full scale, user selectable. Accuracy and linearity: ±1% of rated Vout.
Iout resistor programming 80-100%, 0-5/10 Kohm full scale, user selectable. Accuracy and linearity: ±1.5% of rated Iout.
On/Off control (rear panel) Controlled by voltage: 0-0.6 V/2-15 V, or dry contact, user selectable logic.
Output current monitor 80-5 V or 0-10 V, user selectable, Accuracy: ±1%.
Output voltage monitor 0-5 V or 0-10 V, user selectable, Accuracy: ±1%.
Power supply OK signal TTL high (4-5 V) = OK; 0 V = Fail; 500 ohm series resistance.
CV/CC Indicator 3.3 kW: CV = TTL high (4-5 V) (source current: 10 mA); CC = TTL low (0-0.6 V) (sink current = 10 mA)
5 kW: Open collector; CV mode: OFF, CC mode: ON, Max voltage = 30 V; Max sink current = 10 mA
Enable/disable Dry contact. Open: off, Short: on. Max. voltage at terminal = 6 V
Series and parallel capability
Parallel operation Up to 4 identical units (same model number) can be connected in master/slave mode with
single-wire current balancing
Series operation Up to 2 identical units (same model number) can be connected using external protection diodes
(see Output Terminal Isolation on page 13)
Savable states
In volatile memory
16 (in memory locations 0-15)
Interface capabilities
GPIB SCPI - 1993, IEEE 488.2 compliant interface
LXI Compliance Class C (only applies to units with the LXI label on the front panel)
USB 2.0 Requires Agilent I/O Library version M.01.01 and up, or 14.0 and up
10/100 LAN
Requires Agilent I/O Library version L.01.01 and up, or 14.0 and up
Environmental conditions
Environment Indoor use, installation category II (AC input), pollution degree 2
Operating temperature 0°C to 40°C @ 100% load
Storage temperature –20°C to 70°C
Operating humidity 30% to 90% relative humidity (no condensation)
Storage humidity 10% to 95% relative humidity (no condensation)
Altitude Up to 3000 meters.
Above 2000 m, derate the output current by 2%/100 m and derate the maximum ambient
temperature by 1°C/100 m.
Built-in Web server Requires Internet Explorer 5+ or Netscape 6.2+
All Models (unless otherwise specifi ed)
13
Supplemental Characteristics (Continued)
Regulatory
Regulatory
compliance
compliance
EMC
Complies with the European EMC directive 89/336/EEC for Class A test and measurement products.
Complies with the Australian standard and carries the C-Tick mark.
This ISM device complies with Canadian ICES-001. Cet appareil ISM est conforme
à la norme NMB-001 du Canada.
Electrostatic discharges >1 kV near the I/O connectors may cause the unit to reset and
require operator intervention.
Safety Complies with the European Low Voltage Directive 73/23/EEC and carries the CE-marking.
Complies with the US and Canadian safety standards for test and measurement products.
Any LEDs used in this product are Class 1 LEDs as per IEC 825-1
Acoustic noise
declaration
Statements provided to comply with requirements of the German Sound Emission Directive,
from 18 January 1991:
Sound Pressure Lp <70 dB(A), *At Operator Position, *Normal Operation,
*According to EN 27779 (Type Test).
Schalldruckpegel Lp <70 dB(A) *Am Arbeitsplatz, *Normaler Betrieb, *Nach EN 27779
(Typprüfung).
Output terminal
isolation
8 V to 60 V units
No output terminal may be more than ± 60 VDC from any other terminal or chassis ground.
80 V to 600 V units
No positive output terminal may be more than ± 600 VDC from any other terminal or chassis ground.
No negative output terminal may be more than ± 400 VDC from any other terminal or chassis ground.
All Models (unless otherwise specifi ed)
Dimensions
(excluding connectors and handles) Height: 88 mm (3.46 in); Width: 423 mm (16.65 in); Depth: 442.5 mm (17.42 in)
Weight
3.3 kW: 13 kg (28.6 lbs.); 5 kW: 16 kg (35.2 lbs.)
14
Supplemental Characteristics (Continued)
All Models (unless otherwise specifi ed)
AC Input
Nominal input 230 VAC single-phase option 13 190 - 240 VAC; 50/60 Hz
208 VAC 3-phase option 190 - 240 VAC; 50/60 Hz
400 VAC 3-phase option 380 - 415 VAC; 50/60 Hz
Input current 230 VAC single-phase option
13 23 - 24 A Max @ 100% load
208 VAC 3-phase option
3.3 kW models: 13.6 - 14.5 A Max @ 100% load
5 kW models: 21-22 A max @ 100% load
400 VAC 3-phase option
3.3 kW models: 6.8 - 7.2 A Max @ 100% load
5 kW models: 10.5 - 12 A Max @ 100% load
Input range
230 VAC single-phase option
13 170 - 265 VAC; 47 - 63 Hz
208 VAC 3-phase option
170 - 265 VAC; 47 - 63 Hz
400 VAC 3-phase option
342 - 460 VAC; 47 - 63 Hz
Input VA
3.3 kW models
4000 VA
5 kW models 5800 VA
Power factor
230 VAC single-phase option
13
0.99 at nominal input and rated output power
208 & 400 VAC 3-phase options
3.3 kW models: 0.95 at nominal input and rated output power
5 kW models: 0.94 at nominal input and rated output power
Effi ciency 3.3 kW models 82% - 88%
5 kW models 83% - 88%
Inrush current 230 VAC single-phase option 13 < 50 A
208 VAC 3-phase option < 50 A
400 VAC 3-phase option < 20 A
Notes:
13. Available on 3.3 kW models only.
15
AC Input
Output cover
detail
8 V to 100 V
models
DC Output
Bus-Bar detail
8 V to 100 V
models
Outline Diagram
88.0 mm ±0.3 mm
42.0 mm
39.0 mm ±0.3 mm
60.5 mm
5.0 mm
30.0 mm
φ10.5 mm
40.0 mm
92.0 mm 92.0 mm
50.0 mm 108.0 mm
80.0 mm
482.0 mm ±1.0 mm
497.5 mm (150 V to 600 V models)
442.5 mm ±1.0 mm
423.0 mm ±1.0 mm
86.0 mm ±0.3 mm
16
Front panel
(All models)
Rear panel with busbars
8 V to 100 V models (shown with 230 V single-phase AC input voltage option, available on 3.3 kW models only)
Rear panel with wire clamp connectors
150 V to 600 V models (shown with 400 V 3-phase AC option, available on all models)
= air flow (in front, out rear)
Front and Rear Panel Detail
17
Ordering Information
Model Voltage (V) Current (A) Max Power (W) Series
N8731A 8 V 400 A 3200 W 3.3 kW
N8732A 10 V 330 A 3300 W 3.3 kW
N8733A 15 V 220 A 3300 W 3.3 kW
N8734A 20 V 165 A 3300 W 3.3 kW
N8735A 30 V 110 A 3300 W 3.3 kW
N8736A 40 V 85 A 3400 W 3.3 kW
N8737A 60 V 55 A 3300 W 3.3 kW
N8738A 80 V 42 A 3360 W 3.3 kW
N8739A 100 V 33 A 3300 W 3.3 kW
N8740A 150 V 22 A 3300 W 3.3 kW
N8741A 300 V 11 A 3300 W 3.3 kW
N8742A 600 V 5.5 A 3300 W 3.3 kW
N8754A 20 V 250 A 5000 W 5 kW
N8755A 30 V 170 A 5100 W 5 kW
N8756A 40 V 125 A 5000 W 5 kW
N8757A 60 V 85 A 5100 W 5 kW
N8758A 80 V 65 A 5200 W 5 kW
N8759A 100 V 50 A 5000 W 5 kW
N8760A 150 V 34 A 5100 W 5 kW
N8761A 300 V 17 A 5100 W 5 kW
N8762A 600 V 8.5 A 5100 W 5 kW
All Models (unless otherwise specified)
Opt 861
Unterminated line cord for 208 V 3-phase AC input voltage (Option 208)
Unterminated line cord for 208 V 3-phase AC input voltage (Option 208)
Opt 862
Unterminated line cord for 400 V 3-phase AC input voltage (Option 400)
Unterminated line cord for 400 V 3-phase AC input voltage (Option 400)
Opt 83113
Unterminated line cord for 230 V single-phase AC input voltage (Option 230)
Unterminated line cord for 230 V single-phase AC input voltage (Option 230)
Opt 83213
Unterminated, harmonized line cord for Europe for 230 V single-phase AC
Unterminated, harmonized line cord for Europe for 230 V single-phase AC
input voltage (Option 230)
input voltage (Option 230)
Opt 208
190-240 V, 3-phase AC, 50/60 Hz input (use with line cord Opt 861)
190-240 V, 3-phase AC, 50/60 Hz input (use with line cord Opt 861)
Opt 400
380-415 V, 3-phase AC, 50/60 Hz input (use with line cord Opt 862)
380-415 V, 3-phase AC, 50/60 Hz input (use with line cord Opt 862)
Opt 23013
190-240 V, single-phase AC, 50/60 Hz input (use with line cord Opt 831 or
190-240 V, single-phase AC, 50/60 Hz input (use with line cord Opt 831 or
832)
832)
Agilent N8700 Series
Options
Accessories
N5740A
Rack mount slide kit (required for rack mounting; standard system
Rack mount slide kit (required for rack mounting; standard system
rack-mounting hardware will not work)
rack-mounting hardware will not work)
Notes:
13. Available on 3.3 kW models only.
18
Remove all doubt
Our repair and calibration services
will get your equipment back to you,
performing like new, when prom-
ised. You will get full value out of
your Agilent equipment through-
out its lifetime. Your equipment
will be serviced by Agilent-trained
technicians using the latest factory
calibration procedures, automated
repair diagnostics and genuine parts.
You will always have the utmost
confi dence in your measurements.
For information regarding self main-
tenance of this product, please
contact your Agilent offi ce.
Agilent offers a wide range of ad-
ditional expert test and measure-
ment services for your equipment,
including initial start-up assistance,
onsite education and training, as
well as design, system integration,
and project management.
For more information on repair and
calibration services, go to:
www.agilent.com/fi nd/removealldoubt
Agilent Email Updates
www.agilent.com/fi nd/emailupdates
Get the latest information on the
products and applications you select.
Agilent Direc
t
www.agilent.com/fi nd/agilentdirect
Quickly choose and use your test
equipment solutions with confi dence.
www.lxistandard.org
LXI is the LAN-based successor to
GPIB, providing faster, more effi cient
connectivity. Agilent is a founding
member of the LXI consortium.
Microsoft is a U.S. registered trademark of
Microsoft Corporation.
For more information on Agilent Technolo-
gies’ products, applications or services,
please contact your local Agilent offi ce.
The complete list is available at:
www.agilent.com/fi nd/contactus
Americas
Canada (877) 894-4414
Latin America 305 269 7500
United States (800) 829-4444
Asia Pacifi c
Australia 1 800 629 485
China 800 810 0189
Hong Kong 800 938 693
India 1 800 112 929
Japan 0120 (421) 345
Korea 080 769 0800
Malaysia 1 800 888 848
Singapore 1 800 375 8100
Taiwan 0800 047 866
Thailand 1 800 226 008
Europe & Middle East
Austria 01 36027 71571
Belgium 32 (0) 2 404 93 40
Denmark 45 70 13 15 15
Finland 358 (0) 10 855 2100
France 0825 010 700*
*0.125 €/minute
Germany 07031 464 6333**
**0.14 €/minute
Ireland 1890 924 204
Israel 972-3-9288-504/544
Italy 39 02 92 60 8484
Netherlands 31 (0) 20 547 2111
Spain 34 (91) 631 3300
Sweden 0200-88 22 55
Switzerland 0800 80 53 53
United Kingdom 44 (0) 118 9276201
Other European Countries:
www.agilent.com/fi nd/contactus
Revised: October 1, 2008
© Agilent Technologies, Inc. 2009
Printed in USA, October 29, 2009
5990-3881EN
Product specifi cations and descriptions
in this document subject to change
without notice.
www.agilent.com
www.agilent.com/fi nd/N8700