TE30
20W-30W Single Output External Power
Test & Measurement/Industrial Series
www.slpower.com TE30 Rev 1.8 5-JAN-17 2
General Specifications
AC Input 100-240Vac, ±10%, 47-63Hz, 1∅Turn On Time Less than 700mS @115Vac, full load
Input Current 115Vac: 1.2A, 230Vac: 0.6A Hold-up Time 20mS min., at full Load, 100Vac input
Inrush Current 264Vac, cold start: will not exceed 40A Overtemperature
Protection Will shutdown upon an overtemperature
condition, auto-recovery.
Input Fuse 2.0A, 250Vac Overload Protection 130 to 180% of rating, Hiccup Mode
Earth Leakage
Current Input-GND: <500μA@264Vac, 60Hz, NC
Output-GND: <4mA@264Vac, 60Hz, NC Short Circuit
Protection Hiccup Mode, auto recovery.
Efficiency Meets US DoE Efficiency Level VI Average
efficiency levels Overvoltage
Protection Hiccup Mode. See model chart above for
trip ranges.
Output Power 20 to 30W continuous – See models chart for
specific voltage model ratings. Isolation Input-Output: 4000Vac
Input-Ground: 1500Vac
Output-Ground: 1500Vac
No Load Input
Power <0.1W per DoE Efficiency Level VI
Requirements Safety Standards EN/CSA/UL/IEC 60950-1, 2nd Edition, Am 2
Ripple and Noise See models chart on pg 1. Operating
Temperature -20°C to +70°C
Start Up at -40°C, full load, (warmup period before
all parameters are within published specifications).
Output Voltage See models chart on pg 1. Temperature
Derating See Derating Charts below.
Transient
Response
500
s response time for return to within 0.5%
of final value for any 50% load step over the
range of 5% to 100% of rated load, ∆i/∆t<
0.2A/µs. Max. voltage deviation is +/-3.5%.
Storage Temperature -40°C to +85°C
Regulation See models chart on pg 1. Altitude Operating: to 5000m.
Non-operating: -500 to 40,000 ft.
Drop Test 1.4m from table top to wooden platform, 4
faces. Relative Humidity 5% to 95%, non-condensing
Vibration
Operating: 0.003g/Hz, 1.5grms overall, 3
axes, 10 min/axis, 1-500Hz.
Non-Oper.: random waveform, 3 minutes per
axis, 3 axes and Sine waveform, Vib.
frequency/acceleration: 10-500Hz/1g, sweep
rate of 1 octave / minutes, Vibration time of 10
sweeps / axes, 3 axes
Shock
Operating: Half-sine, 20gpk, 10mS, 3 axes,
6 shocks total
Non-Operating: Half-sine waveform, impact
acceleration of 100G, Pulse duration of 6
mS, Number of shocks: 3 for each of the
three axis
Dimensions See outline drawings MTBF >1,000,000 hours, full load, 110 & 220Vac
input, 25°C amb., per Telcordia 332 Issue 6.
Weight 250g E-Cap Life >8 year life based on calculations at
115Vac/60Hz & 230Vac/50Hz, ambient 25°C
at 24 hrs per day, 365 days/year, 6 power up
cycles per day.
All specifications are typical at nominal input, full load, at 25°C ambient unless noted.