TE30
20W-30W Single Output External Power
Test & Measurement/Industrial Series
www.slpower.com TE30 Rev 1.8 5-JAN-17 1
Features
Meets DoE Efficiency Level VI Requirements
No load input power
Average Efficiency
Up to 30W of AC-DC Power
Universal Input 90-264Vac Input Range
Desktop and Wall-Plug versions
Meets “Heavy Industrial” Levels of EN61000 EMC
Requirements
Meets EN55032/CISPR22 and FCC Part 15.109
Class B Conducted & Radiated Emissions, with 6db
margin
Approved to EN/IEC/UL60950-1, 2nd Ed., Am. 2
E-cap life of >8 years
>1,000,000 hours MTBF
3 Year Warranty
Description
A high performance AC to DC external power supply family designed for test & measurement and industrial applications. The TE30A
Series models are compliant with Efficiency Level VI requirements per U.S. Dept. of Energy, PLUS Heavy Industrial levels of various
EN61000-4-x standards for EMC.
Model Selection
Model
Output
Output
Ripple &
Line
Load
Output
Input
Number Volts Current Power Noise
¹
Regulation Regulation
Connector
TE30A0503F01 5.0V 4.00A 20W 75mV pk-pk ±1% ±5%
2.5 x 5.5 x 9.5mm
Straight Barrel Type,
center positive
Class I Desktop,
IEC60320 C14
Receptacle
TE30A0903F01 9.0V 3.00A 27W 90mV pk-pk ±1% ±5%
TE30A1203F01 12.0V 2.50A 30W 120mV pk-pk ±1% ±5%
TE30A1503F01 15.0V 2.00A 30W 150mV pk-pk ±1% ±5%
TE30A1803F01 18.0V 1.67A 30W 180mV pk-pk ±1% ±5%
TE30A2403F01 24.0V 1.33A 30W 240mV pk-pk ±1% ±5%
TE30A4803F01 48.0V 0.63A 30W 480mV pk-pk ±1% ±5%
TE30A0503N01 5.0V 4.00A 20W 75mV pk-pk ±1% ±5%
2.5 x 5.5 x 9.5mm
Straight Barrel Type,
center positive
Class II Desktop,
IEC60320 C8
Receptacle
TE30A0903N01 9.0V 3.00A 27W 90mV pk-pk ±1% ±5%
TE30A1203N01 12.0V 2.50A 30W 120mV pk-pk ±1% ±5%
TE30A1503N01 15.0V 2.00A 30W 150mV pk-pk ±1% ±5%
TE30A1803N01 18.0V 1.67A 30W 180mV pk-pk ±1% ±5%
TE30A2403N01 24.0V 1.33A 30W 240mV pk-pk ±1% ±5%
TE30A4803N01 48.0V 0.63A 30W 480mV pk-pk ±1% ±5%
TE30A0503Q01 5.0V 4.00A 20W 75mV pk-pk ±1% ±5%
2.5 x 5.5 x 9.5mm
Straight Barrel Type,
center positive
Class II Desktop,
IEC60320 C18
Receptacle
TE30A0903Q01 9.0V 3.00A 27W 90mV pk-pk ±1% ±5%
TE30A1203Q01 12.0V 2.50A 30W 120mV pk-pk ±1% ±5%
TE30A1503Q01 15.0V 2.00A 30W 150mV pk-pk ±1% ±5%
TE30A1803Q01 18.0V 1.67A 30W 180mV pk-pk ±1% ±5%
TE30A2403Q01 24.0V 1.33A 30W 240mV pk-pk ±1% ±5%
TE30A4803Q01 48.0V 0.63A 30W 480mV pk-pk ±1% ±5%
TE30A0503B01 5.0V 4.00A 20W 75mV pk-pk ±1% ±5%
2.5 x 5.5 x 9.5mm
Straight Barrel Type,
center positive
Class II Wall-Plug,
Interchangeable
Blades (North
American Blade
included)²
TE30A0903B01 9.0V 3.00A 27W 90mV pk-pk ±1% ±5%
TE30A1203B01 12.0V 2.50A 30W 120mV pk-pk ±1% ±5%
TE30A1503B01 15.0V 2.00A 30W 150mV pk-pk ±1% ±5%
TE30A1803B01 18.0V 1.67A 30W 180mV pk-pk ±1% ±5%
TE30A2403B01 24.0V 1.33A 30W 240mV pk-pk ±1% ±5%
TE30A4803B01 48.0V 0.63A 30W 480mV pk-pk ±1% ±5%
TE30A0503C01 5.0V 4.00A 20W 75mV pk-pk ±1% ±5%
2.5 x 5.5 x 9.5mm
Straight Barrel Type,
center positive
Class II Wall-Plug,
Fixed North
American Blades³
TE30A0903C01 9.0V 3.00A 27W 90mV pk-pk ±1% ±5%
TE30A1203C01 12.0V 2.50A 30W 120mV pk-pk ±1% ±5%
TE30A1503C01 15.0V 2.00A 30W 150mV pk-pk ±1% ±5%
TE30A1803C01 18.0V 1.67A 30W 180mV pk-pk ±1% ±5%
TE30A2403C01 24.0V 1.33A 30W 240mV pk-pk ±1% ±5%
TE30A4803C01 48.0V 0.63A 30W 480mV pk-pk ±1% ±5%
Notes: 1. Measured at the output connector, with noise probe directly across output and load terminated with 0.1μF ceramic and 10μF low ESR capacitors. For 5V and 6V models, values listed
are typical, 100mV pk-pk maximum with 0.1μF ceramic and 47μF low ESR capacitors used at measurement point.
2. Order blade kit KT-1027K for other blades (EU. UK, Australia)
3. For EU fixed blades, replace “C” in the model number with “M”, for UK blades, replace C” with “G”, for Australia blades, replace “C” with “H”.
4. All specifications are typical at nominal input, full load, at 25C ambient unless noted.
5. For Input Class I models: For AC GND connected to output common (-), insert a “B” in the part number where the “A” is located (TE30B1203F01).
TE30
20W-30W Single Output External Power
Test & Measurement/Industrial Series
www.slpower.com TE30 Rev 1.8 5-JAN-17 2
General Specifications
AC Input 100-240Vac, ±10%, 47-63Hz, 1Turn On Time Less than 700mS @115Vac, full load
Input Current 115Vac: 1.2A, 230Vac: 0.6A Hold-up Time 20mS min., at full Load, 100Vac input
Inrush Current 264Vac, cold start: will not exceed 40A Overtemperature
Protection Will shutdown upon an overtemperature
condition, auto-recovery.
Input Fuse 2.0A, 250Vac Overload Protection 130 to 180% of rating, Hiccup Mode
Earth Leakage
Current Input-GND: <500μA@264Vac, 60Hz, NC
Output-GND: <4mA@264Vac, 60Hz, NC Short Circuit
Protection Hiccup Mode, auto recovery.
Efficiency Meets US DoE Efficiency Level VI Average
efficiency levels Overvoltage
Protection Hiccup Mode. See model chart above for
trip ranges.
Output Power 20 to 30W continuous See models chart for
specific voltage model ratings. Isolation Input-Output: 4000Vac
Input-Ground: 1500Vac
Output-Ground: 1500Vac
No Load Input
Power <0.1W per DoE Efficiency Level VI
Requirements Safety Standards EN/CSA/UL/IEC 60950-1, 2nd Edition, Am 2
Ripple and Noise See models chart on pg 1. Operating
Temperature -20°C to +70°C
Start Up at -40°C, full load, (warmup period before
all parameters are within published specifications).
Output Voltage See models chart on pg 1. Temperature
Derating See Derating Charts below.
Transient
Response
500
µ
s response time for return to within 0.5%
of final value for any 50% load step over the
range of 5% to 100% of rated load, i/t<
0.2A/µs. Max. voltage deviation is +/-3.5%.
Storage Temperature -40°C to +85°C
Regulation See models chart on pg 1. Altitude Operating: to 5000m.
Non-operating: -500 to 40,000 ft.
Drop Test 1.4m from table top to wooden platform, 4
faces. Relative Humidity 5% to 95%, non-condensing
Vibration
Operating: 0.003g/Hz, 1.5grms overall, 3
axes, 10 min/axis, 1-500Hz.
Non-Oper.: random waveform, 3 minutes per
axis, 3 axes and Sine waveform, Vib.
frequency/acceleration: 10-500Hz/1g, sweep
rate of 1 octave / minutes, Vibration time of 10
sweeps / axes, 3 axes
Shock
Operating: Half-sine, 20gpk, 10mS, 3 axes,
6 shocks total
Non-Operating: Half-sine waveform, impact
acceleration of 100G, Pulse duration of 6
mS, Number of shocks: 3 for each of the
three axis
Dimensions See outline drawings MTBF >1,000,000 hours, full load, 110 & 220Vac
input, 25°C amb., per Telcordia 332 Issue 6.
Weight 250g E-Cap Life >8 year life based on calculations at
115Vac/60Hz & 230Vac/50Hz, ambient 25°C
at 24 hrs per day, 365 days/year, 6 power up
cycles per day.
All specifications are typical at nominal input, full load, at 25°C ambient unless noted.
TE30
20W-30W Single Output External Power
Test & Measurement/Industrial Series
www.slpower.com TE30 Rev 1.8 5-JAN-17 3
EMI/EMC Compliance
Conducted Emissions: EN55032/CISPR22 Class B, FCC Part 15, Class B: 6db margin typ, at 115 and 230Vac
Radiated Emissions: EN55032/CISPR22 Class B, FCC Part 15, Class B: 3db margin typ, at 115 and 230Vac
Common Mode Noise: High Frequency (100kHz-20MHz): <40mA pk-pk
Electro-Static Discharge (ESD)
Immunity on Power ports: EN55024/IEC61000-4-2, Level 4: +/- 8kV contact, +/- 15kV air, Criteria A
Radiated RF EM Fields Susceptibility EN55022/EN61000-4-3, 10V/m, 80MHz-2.7GHz, 80% AM at 1kHz
Electrical Fast Transients (EFT) /Bursts: EN55024/IEC61000-4-4, Level 4, +/- 4.4kV, 100Khz rep rate, 40A, Criteria A
Surges, Line to Line (Diff Mode) and Line
to GND (CMN Mode) EN55024/IEC61000-4-5, Level 4, +/-2kV DM, +/-4kV CM, Criteria A
Conducted Disturbances induced by RF
Fields EN55022/IEC61000-4-6, 3.6V/m Level 4, 0.15 to 80Mhz; and 12V/m) in ISM and amateur
radio bands between 0.15Mhz and 80Mhz, 80% AM at 1KHz
Rated Power frequency magnetic fields EN55024/IEC1000-4-8, Level 4: 30 A/m, 50/60 Hz
Voltage Interruptions, Dips, Sags &
Surges
EN55024/IECEN61000-4-11:
--100% dip for 20mS, Criteria A
--100% dip for 5000mS (250/300 cycles), Criteria B
--60% dip for 100mS, Criteria B
--30% dip for 500mS, Criteria A
Harmonic Current Emissions EN55011/EN61000-3-2, Class A
Flicker Test EN61000-3-3
All specifications are typical at nominal input, full load, at 25°C ambient unless noted.
Output Power Derating
Output power is derated above 40°C as follows, for operation over the entire AC input range (90-264Vac).
0
5
10
15
20
25
30
35
-20° -10° 10° 20° 30° 40° 50° 60° 70°
Output Power
Ambient Operating Temperature (°C)
5V Models
9V Models
12V-48V Models
TE30
20W-30W Single Output External Power
Test & Measurement/Industrial Series
www.slpower.com TE30 Rev 1.8 5-JAN-17 4
Mechanical Drawing
IEC60320 C14 Receptacle, 2.5 x 5.5 x 9.5mm Barrel Connector Interchangeable N.A. Blade, 2.5 x 5.5 x 9.5mm barrel connector
Notes: 1. All dimensions in mm.
2. Interchangeable blade models come with North American blade fitted. For other blades (EU, UK, Aust.) order blade kit KT1027K.
Connector Information
Standard models include a 2.5 x 5.5 x 9.5mm straight barrel type connector (Ault #3), center positive. Other standard options are listed below.
The “03” in the standard model number is replaced by the applicable digits below:
Cable length for 5V
a
n
d
9V
models is 1200 +/
-
50mm
1450±50
54
95.5
9
6
55
1450±50
33.6
Cable length for 5V
a
n
d
9V
models is 1200 +/
-
50mm
TE30
20W-30W Single Output External Power
Test & Measurement/Industrial Series
www.slpower.com TE30 Rev 1.8 5-JAN-17 5
Efficiency Level VI Information:
Data Sheet © 2017 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. However, SL Power accepts no responsibility for
consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.
TE30A Series
9V
-
48V models
TE30A Series
5V
models