Delivery Program
Product Category: Load Cells
Model: 41 Precision Low Profile
Order Code(s): AL111
USE THE CHART BELOW TO DETERMINE LEAD TIMES1
The range or option code with the longest lead time dictates the shipping time. Categories shaded in grey are required selections.
For example (reference only):
If you build this: The order configuration is this: The delivery class is:
AL111 + 50 lb load range (BN), 60 °F to 160 °F (1a),
Unamplified, mV/V output (2u), and horizontal electrical
exit port (15a)
AL111 – BN – 1a – 2u – 15a Quick ship, ships in 1 to 5
days
AL111 + 50 lb load range (BN), 30 °F to 130 °F (1b), four-
wire output (2b), and horizontal electrical exit port (15a)
AL111 – BN – 1b – 2b – 15a Fast-track manufacture,
ships within 4 weeks
AL111 + 5 lb (AT), 30 °F to 130 °F (1b), four-wire output
(2b), and vertical electrical exit port (15b)
AL111 – AT – 1b – 2b – 15b Build-to-order, call
Honeywell for lead time
Page 1 of 2
39B
Quick-ship
(Ships in 1-5 days)
Fast track manufacture
(Ships within 4 weeks)
Build-to-order
(Call Honeywell 1-800-848-6564 or
+1 614-850-5000)
Load ranges 50 (BN),100 (BR), 500 (CR),
1000 (CV), 2000 (DL), 5000
(DR), 10000 (DV), 20000
(EL), 50000 lb (EP)
7500 lb (DT) 5 (AT), 10 (AV), 25 (BL),250 (CN), 3000
(DN), 4000 (DP), 15000 (EJ), 30000 (EN),
75000 (ER), 100000 (ET), 150000 (FJ),
200000 (FL), 300000 (FN), 400000 (FP),
500000 lb (FR)
Temperature
compensation
1a. 60 °F to 160 °F *
1b. 30 °F to 130 °F
1c. 0 °F to 185 °F
1d. -20 °F to 130 °F
1e. -20 °F to 200 °F
1f. 70 °F to 250 °F
1i. -65 °F to 250 °F
1j. 0 °C to 50 °C
1k. -20 °C to 85 °C
1m. -25 °C to 110 °C
1g. 70 °F to 325 °F
1h. 70 °F to 400 °F
Internal
amplifiers
2u. Unamplified, mV/V
output *
2b. 4 wire, ±5 Vdc
2c. 0-5 Vdc output
2j. 4-20 mA (three-wire) output
2t. 0 Vdc to 10 Vdc
2k. 4 mA to 20 mA (two-wire)
2n (2N) 4 mA to 20 mA (wire) intrinsically
safe
Electrical
connector
orientation
15a. Horizontal electrical exit
port orientation *
15b. Vertical electrical exit port orientation
15c. Radial electrical exit port orientation
15d. Connector on end of cable
Internal amplifier
enhancements
3d. Remote buffered shunt calibration
3a. Input/output isolation
Overload stops 4a. Overload stops
Electrical
termination
6a. Bendix PTIH-10-6P 6-pin
(ranges to 5000 lb) *
6b. MS3102E-14S-6P
(ranges 7500 lb and up) *
6e. Integral cable: Teflon
6i. Integral underwater cable (for ranges 7500 and
above)
6f. Integral cable: PVC
6g. Integral cable: Neoprene
6h. Integral cable: Silicone
6i. Integral underwater cable (for ranges 5k
and below)
6j. 1/2-14 conduit fitting with 5 ft of 4
conductor PVC cable
6q. Molded integral cable polyurethane
6v. Phoenix connector on end of cable