Keysight N2780B Series
AC/DC Current Probes
A wide selection of current probes
to meet your applications needs
Data Sheet
02 | Keysight | N2780B Series AC/DC Current Probes A wide selection of current probes to meet your application’s needs - Data Sheet
Various bandwidths: DC to 2 MHz,
10 MHz, 50 MHz, 100 MHz
DC and AC measurements
Superior 1% accuracy and high
signal-to-noise ratio
Overload-protect function prevents
probe damage from excessive input
Direct connection to high-
impedance 1 MΩ BNC input of
oscilloscope
“Demagnetize” button to remove
any residual magnetism that builds
up in the magnetic core
External power supply (N2779A)
lets you connect up to three
N278xB current probes to a
single power supply
Compatible with any oscilloscope
with a high-impedance BNC input, the
new N2780B Series current probes
offer accurate and reliable solution for
measuring DC and AC currents.
Hybrid technology for AC and DC measurements
Using hybrid technology that includes a Hall-effect sensor and an AC current
transformer, the probes provide accurate measurement of DC or AC currents up
to 500 Arms (for model N2780B) or DC–100 MHz (for model N2783B), without
breaking into the circuit. Using split core construction, the probe easily clips on
and off of a conductor.
Wide range of applications
The current probes feature broad measurement ranges (up to 500 A), flat
frequency response, low noise and low insertion loss that make the probes ideal
for current measurements in areas such as measuring steady state or transient
current of motor drives, switching power supplies, inverters, controllers, sensors,
disk drives, LCD displays, electronic ballasts and amplifiers. The high signal-to-
noise ratio of the N2782B and N2783B makes them ideal for making low-level
current measurements in milliampere ranges.
Accurate current measurement
A built-in DEMAG (demagnetize) function allows the removal of any residual
magnetism that has built up in the magnetic core due to power on/off switching
or excessive input current. In addition, voltage offset or temperature drift on the
probe can be easily corrected by using the zero adjustment control.
Figure 1. N2780B Series current probes
with N2779A power supply
Figure 2. N2783B, N2780B, N2781B and N2782B current probe (from left to right)
03 | Keysight | N2780B Series AC/DC Current Probes A wide selection of current probes to meet your application’s needs - Data Sheet
Figure 3. Frequency response of N2783B Figure 4. Continuous maximum input rating of N2783B
-10
-20
-30
-40
-50
100 10k 1M 100M
1
-60
Frequency (Hz)
Amplitude (dB)
35
30
25
20
15
10
5
10 100 1k 10k 100k 1M 10M 100M
Frequency (Hz)
Maximum input current (Arms)
Figure 5. Insertion impedance of N2783B Figure 6. Amplitude accuracy characteristics of N2783B
100 1k 10k 100k 1M 10M 100M
Frequency (Hz)
1m
10m
100m
1
10
Input Impedance (ohm)
0.001 0.01 0.1 110 100
-6
-3
0
3
6
9
12
Input Current (A)
Deviation (%)
AC 50 Hz DC
N2779A 3-channel power supply specifications
Applicable current probes: N2780B, N2781B, N2782B, N2783B and N2774A
Number of power supply connectors: 3
Connector type: LEMO inc./FFA..0S.304.CNAC42Z
Output voltage: DC (12 V, 2.5 A)
Maximum rated power: 170 VA
Input power requirement: AC 100-240 VAC, 50/60 Hz, 125-170 VAC
Note: For the characteristic plots of other current probe models, refer to the N2780B Series current probe user’s manual.
04 | Keysight | N2780B Series AC/DC Current Probes A wide selection of current probes to meet your application’s needs - Data Sheet
Compatible Oscilloscopes
Any oscilloscope offering 1 MΩ BNC
input including Keysight Technologies,
Inc. 1000, 3000 InfiniiVision 2000X,
3000X, 5000, 6000 and 7000 Series,
and Infiniium 8000 and 9000 Series.
You must select the input impedance
of the oscilloscope to be 1 MΩ in order
to make accurate measurements. If the
oscilloscope you are using has a 50Ω
input impedance setting only, you can
purchase the Keysight E2697A 50Ω to 1
MΩ adapter for use with the Infiniium
80000 or 90000 Series or the N5449A
high impedance probe adapter for use
with the Infiniium 90000 X-Series.
Ordering Information
N2780B
2 MHz/500A AC/DC current probe
N2781B
10 MHz/150A AC/DC current probe
N2782B
50 MHz/30A AC/DC current probe
N2783B
100 MHz/30A AC/DC current probe
N2779A
3-channel power supply for
N2780B Series current probes
Note*: The amplitude accuracy specifications are guaranteed at 23°C ± 3°C (or 73°F ± 5°F)
**: Insulated conductor should be used.
Model number N2780B N2781B N2782B N2783B
Bandwidth (-3dB) DC to 2 MHz DC to 10 MHz DC to 50 MHz DC to 100 MHz
Risetime 175 ns or less 35 ns or less 7 ns or less 3.5 ns or less
Maximum current (continuous) RMS 500 A 150 A 30 A 30 A
Maximum peak current (non-continuous) 700 A peak 300 A peak; 50 A peak 50 A peak
Lowest measurable current (at ±3% accuracy
at DC, scope set to 1 mV/div and
high-resolutionmode on)
20 mA 20 mA 5 mA 5 mA
Output voltage rate 0.01 V/A (100:1) 0.01 V/A (100:1) 0.1 V/A (10:1) 0.1 V/A (10:1)
Max input voltage** 600 V CAT II,
300 V CAT III
600 V CAT II,
300 V CAT III
300 V CAT I 300 V CAT I
Amplitude accuracy*
(DC and 45 to 66 Hz, rated current)
±1.0% rdg.
± 500 mA
±1.0% rdg.
± 100 mA
±1.0% rdg.
± 10 mA
±1.0% rdg.
± 10 mA
Noise (measured with 20 MHz
bandwidth limit filter on the scope)
Equivalent to
25 mArms or less
Equivalent to
25 mArms or less
Equivalent to
2.5 mArms or less
Equivalent to
2.5 mArms or less
Temperature coefficient for sensitivity (within a
range of 0°C to 40 °C or 32 °F to 104 °F)
±2% or less ±2% or less ±2% or less ±2% or less
Effect of external magnetic fields
(in a DC to 60 Hz, 400 A/m magnetic field)
Equivalent to a
maximum of
800 mA
Equivalent to a
maximum of
150 mA
Equivalent to a
maximum of 20 mA
Equivalent to a
maximum of 5 mA
Maximum rated power 7.2 VA (with rated
current)
5.5 VA (with rated
current)
5.6 VA (with rated cur-
rent)
5.3 VA (with rated cur-
rent)
Rated supply voltage DC ±12 V ±0.5 V DC ±12 V ±1 V DC ±12 V ±0.5 V DC ±12 V ±0.5 V
Diameter of measurable conductors 20 mm dia. (0.79” dia.) 20 mm dia. (0.79”
dia.) )
5 mm dia. (0.2” dia.) 5 mm dia. (0.2” dia.)
Diameter of measurable conductors Sensor cable:
Approx. 2 m (78.7”)
Power supply cable:
Approx. 1 m (39.4”)
Sensor cable:
Approx. 2 m (78.7”)
Power supply cable:
Approx. 1 m (39.4”)
Sensor cable:
Approx. 1.5 m (78.7”)
Power supply cable:
Approx. 1 m (39.4”)
Sensor cable
Approx. 1.5 m (78.7”)
Power supply cable:
Approx. 1 m (39.4”)
myKeysight
www.keysight.com/find/mykeysight
A personalized view into the information most relevant to you.
www.axiestandard.org
AdvancedTCA® Extensions for Instrumentation and Test (AXIe) is an
open standard that extends the AdvancedTCA for general purpose and
semiconductor test. Keysight is a founding member of the AXIe consortium.
www.lxistandard.org
LAN eXtensions for Instruments puts the power of Ethernet and the
Web inside your test systems. Keysight is a founding member of the LXI
consortium.
www.pxisa.org
PCI eXtensions for Instrumentation (PXI) modular instrumentation delivers a
rugged, PC-based high-performance measurement and automation system.
Three-Year Warranty
www.keysight.com/find/ThreeYearWarranty
Keysight’s commitment to superior product quality and lower total cost
of ownership. The only test and measurement company with three-year
warranty standard on all instruments, worldwide.
Keysight Assurance Plans
www.keysight.com/find/AssurancePlans
Up to five years of protection and no budgetary surprises to ensure your
instruments are operating to specification so you can rely on accurate
measurements.
www.keysight.com/quality
Keysight Electronic Measurement Group
DEKRA Certified ISO 9001:2008
Quality Management System
Keysight Channel Partners
www.keysight.com/find/channelpartners
Get the best of both worlds: Keysight’s measurement expertise and product
breadth, combined with channel partner convenience.
www.keysight.com/find/probes
For more information on Keysight
Technologies’ products, applications or
services, please contact your local Keysight
office. The complete list is available at:
www.keysight.com/find/contactus
Americas
Canada (877) 894 4414
Brazil 55 11 3351 7010
Mexico 001 800 254 2440
United States (800) 829 4444

Australia 1 800 629 485
China 800 810 0189
Hong Kong 800 938 693
India 1 800 112 929
Japan 0120 (421) 345
Korea 080 769 0800
Malaysia 1 800 888 848
Singapore 1 800 375 8100
Taiwan 0800 047 866
Other AP Countries (65) 6375 8100
Europe & Middle East
Austria 0800 001122
Belgium 0800 58580
Finland 0800 523252
France 0805 980333
Germany 0800 6270999
Ireland 1800 832700
Israel 1 809 343051
Italy 800 599100
Luxembourg +32 800 58580
Netherlands 0800 0233200
Russia 8800 5009286
Spain 0800 000154
Sweden 0200 882255
Switzerland 0800 805353
Opt. 1 (DE)
Opt. 2 (FR)
Opt. 3 (IT)
United Kingdom 0800 0260637
For other unlisted countries:
www.keysight.com/find/contactus
(BP-05-19-14)
05 | Keysight | N2780B Series AC/DC Current Probes A wide selection of current probes to meet your application’s needs - Data Sheet
This information is subject to change without notice.
© Keysight Technologies, 2012 - 2014
Published in USA, August 2, 2014
5989-6432EN