Miniature Switches Series 83 161 DIN 41635 A Types General specifications Layout 2 3 6 Part numbers for standard products with connections of type Components Material - Case : glass-filled polyamide (self-extinguishing version to UL 94 VO and IEC 695-2-1 850 C - available on request) - Button : polyamide - Contacts : nickel silver or gold alloy (dual-current) Actuators - flat : stainless steel - roller : stainless steel, glass-filled polyamide roller - other types of polyamide Approvals: NF - UL/cUL Operating curve For type 83 161 5 - 5 SP 4136 For type 83 161 1 3 Number of operations Number of operations Resistive circuit: Inductive circuit { c L = 5 ms R a cos = 0.8 831613 Mechanical 831611 durability Resistive circuit: inductive circuit { c L = 5 ms R a cos = 0.8 Mechanical durability Features Electrical characteristics Current Horsepower Current rating at 125/250 V A HP Mechanical characteristics Operating force - max. Release force - min. Total travel force - max. Permitted overtravel force - max. Rest position - max. Tripping point Differential travel Overtravel - min. (OT) Ambient operating temperature Mechanical durability (for 2/3 OT) Contact gap Weight N (oz.) N (oz.) N (oz.) N (oz.) mm (in.) mm (in.) mm (in.) mm (in.) C (F) Operations mm (in.) g (oz.) Contact type C (Form C) SPDT B (Form B) SPNC A (Form A) SPNO Mechanical durability Connections Rating in Amps For type 83 161 8 Rating in Amps For type 83 161 9 SP 4136 Number of operations Number of operations 3 for 1/4 Quick Connects Actuators and mounting positions Resistive circuit: Resistive circuit: 2 solder A 79 215 740 Part numbers for standard actuators Actuators-Length mm (in.) Flat 161A R14.2 (.56) Mechanical durability Mechanical durability Mounting positions Coefficient Tripping point (except 83 161 6) Tripping point 83 161 6 Rating in Amps Rating in Amps For types 83 161 8 - 9 SP 4136 dual-current Models 83 161 8 and 83 161 9 SP 4136 are designed to operate equally well on dual-current (1 mA 4 V minimum) or medium-current (5 A maximum) circuits. However, a given product should only be used to switch one type of circuit during its working life. Part numbers for standard actuators Actuators-Length mm (in.) A 2 15.2 1(.6.004) 14.8 1(.59.004) B 1 15.2 0.45(.6.018) 15 0.45(.59.018) H 79 218 651 Dummy roller 161G R21.8 (.86) Mounting positions A B Coefficient 3 1.8 2 .08 Tripping point (except 83 161 6) 21.7 (.85 ) 21.7 0.7(.85.03) Tripping point 83 161 6 21.5 2(.85.08) 21.5 07(.85.03) Except where otherwise indicated, flat and roller actuators are supplied unmounted. Other information For other forces, actuators, connections and temperatures, please consult us. Normally stocked items Catalog products produced to order Products and specifications subject to change without notice. Order/Technical Support - Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 3/14 1 83161.1(10.1A) 83161.2(15.1A) 83161.3(10.1A) 831611C2.0 831611C3.0 831611C6.0 831612C2.0 831612C3.0 831612C6.0 831613C2.0 831613C3.0 831613C6.0 High Force High Current Standard 10.1 1/2 15.1 1/2 83161.5(4A) 83161.9(0.1A) 83161.5SP4136 83161.9SP4136 831615C2.0 831615C3.0 831615C6.0 Low Force 10.1 1/2 83161.8(0.1A) 831616C2.0 831616C3.0 831616C6.0 Ultra Light Force 4 1/10 83161.6 831618C2.0 831618C3.0 831618C6.0 Wide Gap 4 1/10 Dual Current 6.1 1/3 0.1 N/A 3 (10.5) 1 (3.5) 4.5 (15.8) 20 (70.5) 16.1 (0.63) 14.70.4 (.580.16) 0.35 (0.014) 1.1 (0.05) -20 +125 (-4 +257) 107 0.4 (0.016) 5.6 (.2) 0.8 (2.8) 0.2 (0.7) 2 (7.0) 20 (70.5) 16.2 (0.64) 14.70.3 (.580.16) 0.35 (0.014) 1.2 (0.05) -20 +125 (-4 +257) 2 x 107 0.4 (0.016) 5.6 (.2) 0.8 (2.8) 0.2 (0.7) 2 (7.0) 20 (70.5) 16.2 (0.64) 14.70.3 (.580.16) 0.35 (0.014) 1.2 (0.05) -20 +125 (-4 +257) 2 x 107 0.4 (0.016) 5.6 (.2) 0.25 (0.9) 0.05 (0.18) 0.35 (1.2) 20 (70.5) 16.3 (0.64) 14.70.4 (.580.16) 0.35 (0.014) 1.1 (0.05) -20 +125 (-4 +257) 5 x 107 0.4 (0.016) 5.6 (.2) 0.15 (0.54) 0.04 (0.14) 0.2 (0.72) 20 (70.5) 16.3 (0.64) 14.70.3 (.580.16) 0.35 (0.014) 1.2 (0.05) -20 +125 (-4 +257) 5 x 107 0.4 (0.016) 5.6 (.2) 5 (18) 0.5 (1.8) 6 (21.6) 20 (70.5) 16.1 (0.63) 14.50.4 (.580.16) 0.8 (0.03) 0.9 (0.035) -20 +125 (-4 +257) 5 x 104 3.2 (0.126) 5.6 (.2) 0.8 (2.8) 0.2 (0.7) 0.2 (.07) 20 (70.5) 16.2 (0.64) 14.70.4 (.580.16) 0.35 (0.014) 1.2 (0.05) -20 +125 (-4 +257) 2 x 107 0.4 (0.016) 5.6 (.2) C B A C B A C B A C B A C B A C B A C B A 2 3 3 5 screw 6 for 3/16 Quick Connects 7 for .11 Quick Connects 4 B 70 507 524 Flat 161A R25.4 (1) A 4 15.22.5 (.6.1) 14.42.5(.56.1) B 2 15.21(.6.04) 14.81(.58.04) E C 1.5 15.2 0.8(.6.03) 14.9 0.8(.59.03) 79 215 742 Roller 161E R13.6 (.54) A 2 20.51.5(.81.06) 20.11.5(.79.06) L B 1 20.50.8(.81.03) 20.30.8(.80.03) V G 70 507 529 Roller 161E R24.1 (.95) A 4 20.52.9(.81.11) 19.72.9(.76 .11) B 2 20.51.5(.81.06) 20.11.5(.79.06) F 70 507 528 Dummy 161F roller R22.2 (.84) C 1.5 20.51.2(.81.05) 20.21.2(.79 .05) A 3 20.42(.8.08) 20.22(.79.08) C 70 507 526 B C 1.8 1.5 0.7 .03 20.5 (.81 ) 20.50.9(.81.035) 20.22(.79.08) 4 D 79 215 835 Flat 161A R50 (1.9) Flat 161A R60 (2.39) 161V ** Telescopic plunger Manual action 161L D Factory Mount only D Factory Mount only B C B C A A 1 6 3 2 7 3.5 2.2 1 21.5 1 (.85 .04 ) 15.26.3 15.22 15.21.6 15.26.9 15.22.5 15.22.3 18.35 0.45 21.5 1 (.85 .04 ) For factory mounting, specify fixing position A, B or C ** For 83 161 1, 83 161 3, 83 161,6, 83 161 8, mounted in factory (supplied without nut) To order, please specify : 1 Switch Type 831612 831619 831613 831616 831615 831611 831618 2 Contact Type A B C To order actuators seperately, use the 8 digit P/N 3 Connection Example : 831612 C 3 * C A 4 2 3 5 6 7 Example switch is 831612, SPDT, 1/4" Q.C., C actuator mounted in A position 5 Actuators O A B C D E F G H L V Actuator Position A B C D A C B (std) D O = No actuator 3/15 5