Specifications by Model Number – 4 Amp Contact Versions
Fixed Timer Adjustable Timer Input Temperature Contact Contact
Model Number Model Number Voltage Range Rating Arrangement
4610 4710 DC -55°C to +125°C 10 Amp 1 Form C (SPDT)
4611 4711 DC -55°C to +125°C 10 Amp 2 Form C (DPDT)
4621 4721 DC -55°C to +125°C 4 Amp 1 Form C (1PDT)
4622 4722 DC -55°C to +125°C 4 Amp 2 Form C (DPDT)
4624 4724 DC -55°C to +125°C 4 Amp 4 Form C (4PDT)
4671 4771 AC -55°C to +125°C 4 Amp 1 Form C (SPDT)
4672 4772 AC -55°C to +125°C 4 Amp 2 Form C (DPDT)
4674 4774 AC -55°C to +125°C 4 Amp 4 Form C (4PDT)
Environmental Specifications
Temperature Range:
-55°C to +125°C.
Vibration: 20 G’s, 10 - 2,000 Hz.
Shock: 50 G’s, 11 ± 1ms duration.
Insulation Resistance: 1,000
megohms, min., at 500Vdc.
Dielectric Strength: 1,000Vrms, 60
Hz., at sea level, all terminals to case.
Sealing: Hermetic, 1.3 in. (33.0mm) of
mercury.
Life: 100,000 operations, min. (4A
models); 50,000 operations, min. (10A
models);
Weight:
4A units: 4.5 oz (127.6g) max.
10A units: 8.5 oz (240g) max.
1
Catalog 8-1773439-0 Dimensions are in inches and Dimensions are shown for USA: 1-800-522-6752 South America: 55-11-3611-1514
Revised 4-05 millimeters unless otherwise reference purposes only. Canada: 1-905-470-4425 Hong Kong: 852-2735-1628
specified. Values in brackets Specifications subject Mexico: 01-800-733-8926 Japan: 81-44-844-8013
www.tycoelectronics.com are metric equivalents. to change. C. America: 52-55-5-729-0425 UK: 44-141-810-8967
© 2005 by Tyco Electronics Corporation. All Rights Reserved.
CII and TYCO are trademarks.
Other products and company names mentioned herein may be trademarks of their respective owners.
Product Facts
AC/DC input interval timer
offered in fixed (4600) and
adjustable (4700) types
Up to 10A loads
Reverse polarity protection
Hermetic package
Built to MIL-R-83726
environmentals
Many customizing options
Extended timing ranges
Tighter timing tolerances
Header and mounting
115Vac, 60 Hz. input types
Part Numbering System
Typical Part Number 4722 –C – 1102
Model Number:
Four digit code from table above.
Mounting (see outline dimension drawings):
A = Studs on bottom B = Studs on top C = Studs on side
Timing Code:
Four-digit code for any value between 100ms and 600s for fixed (4600) timers, and
100ms and 240s for adjustable (4700) timers.
The timing code consists of four digits and gives the time in ms. The first three digits
are the significant figures and the last digit is the number of zeros following the
significant figures; thus 50 ms would be coded 0500, 1.1 s would read 1101, and 1 m
(60 s) would be 6002.
Adjustable timers cover one decade, e.g., 62 ms to 620 ms. The upper decade limit is
Tmax. in the timing formula and is the the value defined by the timing code in the part
number.
4600/4700 Series Interval Timers
Fixed/Adjustable Timing, Relay Output
CII 4600/4700 series interval
timers combine solid state
timing circuits with
electromechanical output
relays in robust hermetically
sealed enclosures. The 4600
types are fixed timers, while the
4700 models are adjustable via
an external resistor. Numerous
output options include 4A rated
contacts in 1, 2 and 4 form C
(SPDT, DPDT and 4PDT)
arrangements and 10A rated
contacts in 1-2 form C (SPDT-
DPDT) arrangements.
Electrical Specifications
Timing Range:
4600 series (fixed): 100 ms to 600 s.
4700 series (adjustable): 100 ms to
240 s.
Tolerance: ±10%
Recycle Time: 10 ms (DC input),
50ms (AC input).
Operate Time (Max.) : 10 ms (4A
models), 20ms (10A models).
Input Voltage: 18 to 31Vdc,
105 to 125Vac, 400 Hz.
Current Drain (at 25°C, 28Vdc):
DC Coil, 10A contacts:
1- and 2-pole: 135mA maximum.
AC or DC Coil, 4A contacts:
1-pole: 100mA maximum.
2-pole: 150mA maximum.
3- and 4-pole: 200mA maximum.
Contact Ratings:
DC Coil, 10A contacts:
10A resistive @ 30Vdc.
5A inductive @ 30Vdc.
5A resistive @ 115 Vrms, 400 Hz
3A inductive @ 115 Vrms, 400 Hz
AC or DC Coil, 4A contacts:
4A resistive @ 30Vdc.
1A inductive @ 30Vdc.
2A resistive @ 115 Vrms, 400 Hz
1A inductive @ 115 Vrms, 400 Hz
Adjustable Timing Formula
(4700 types)
The resistance required to obtain timing
within this range is determined by using
the formula:
Rx = 400K (T/Tmax.) – 40K, where
Rx = External Resistance in Ohms,
T - Desired Time in Seconds, and
Tmax. = Maximum Time (Code).
A high quality deposited carbon ±1%,
0.1W (min.) resistor is recommended for
external resistance.
A typical part number for an adjustable timer would be 4722–C–1102. This is a DC
unit in the -55°C to +125°C temperature range with a 2 form C (DPDT) contact
arrangement in a style “C” mounting, with a maximum time delay of 11s.
Timing Diagram
Apply power and the output will
energize. After time-out, the output will
revert to de-energized state. Remove and
reapply input to cycle.
ON
OFF
INPUT
ON
OFF
OUTPUT
2
4600/4700 Series Delay On Operate Timers (Continued)
High Performance Electronic Products
Catalog 8-1773439-0 Dimensions are in inches and Dimensions are shown for USA: 1-800-522-6752 South America: 55-11-3611-1514
Revised 4-05 millimeters unless otherwise reference purposes only. Canada: 1-905-470-4425 Hong Kong: 852-2735-1628
specified. Values in brackets Specifications subject Mexico: 01-800-733-8926 Japan: 81-44-844-8013
www.tycoelectronics.com are metric equivalents. to change. C. America: 52-55-5-729-0425 UK: 44-141-810-8967
2.419
[61.44]
MAX.
SEATED
HEIGHT
.063 MAX.
[1.60]
.375
[9.53]
#6-32 THD
4 PLACES
INDEX DOT
1.250
[31.75]
1.790
[45.47]
1.284
[32.61] .750
[19.05]
.063 MAX.
[1.60]
.375
[9.53]
#6-32 THD
4 PLACES
INDEX DOT
.297
[7.54]
1.250
[31.75]
1.790
[45.47]
1.284
[32.61] .750
[19.05]
2.419
[61.44]
MAX.
SEATED
HEIGHT
.062 MAX.
[1.575]
.375
[9.53]
#6-32 THD
4 PLACES
INDEX
DOT
.625
[15.875]
.910
[23.11]
.625
[15.875]
.
31
[7.87]
.297
[7.54]
1.25
[31.75]
2.357
[59.88]
MAX.
1.284
[32.61]
.530
[13.46]
1.813
[46.05]
MAX.
SEATED
HEIGHT
Outline Dimensions
Mounting Option A Mounting Option B Mounting Option C
2.384
[60.55]
MAX.
.063 MAX.
[1.60]
.375
[9.53]
#4-40 THD
4 PLACES
INDEX DOT
.75 DIA.
[19.05]
MAX.
.875
[22.22]
1.25 MAX.
[31.75]
1.0 MAX.
[25.4]
.625
[15.875]
.063 MAX.
[1.60] .375
[9.53]
#4-40 THD
4 PLACES
INDEX DOT
.875
[22.22]
1.25 MAX.
[31.75]
1.0 MAX.
[25.4]
.625
[15.875]
.250 MAX.
[6.35]
.81 DIA.
[50.57]
MAX.
2.384
[60.55]
MAX.
.062 MAX.
[1.57]
.375
[9.53]
#4-40 THD
4 PLACES
INDEX
DOT
.625
[15.875]
1.25 MAX.
[31.75]
1.0 MAX.
[25.4]
.625
[15.875]
.438 MAX.
[11.12]
1.25
[31.75]
.78 DIA.
[19.8]
MAX.
2.384
[60.55]
MAX.
Mounting Option A Mounting Option B Mounting Option C
INPUT
INDEX DOT
+
INPUT
INDEX
DOT
+
TIMING
RESISTOR TIMING
RESISTOR
INPUT
INDEX DOT
+
TIMING
RESISTOR
10 Amp Units
4 Amp Units
4700 Series (Adjustable)
Wiring Diagrams
INPUT
INDEX DOT
+
INPUT
INDEX DOT
+
INPUT
INDEX DOT
+
4600 Series (Fixed)
1 Form C 2 Form C 3 Form C
1 Form C 2 Form C 3 Form C