March 2007 Rev 1 1/110
1
M58LT128HST
M58LT128HSB
128-Mbit (8 Mb ×16, Multiple Bank, Multilevel interface, Burst)
1.8 V supply, Secure Flash memories
Features
Supply voltage
–V
DD = 1.7 V to 2.0 V for program, erase
and read
–V
DDQ = 2.7 V to 3.6 V for I/O buffers
–V
PP = 9 V for fast program
Synchronous / Asynchronous Read
Synchronous Burst Read mode: 52 MHz
Asynchronou s Page Read mode
Random Access: 85 ns
Synchronous Burst Read Suspend
Programming time
2.5 µs typical Word program time using
Buffer Enhanced Factory Program
command
Memory organization
Multiple Bank memo ry array: 8-Mbit Banks
Parameter Blocks (top or bottom location)
Dual operations
program/erase in one Bank while read in
others
No delay between read and write
operations
Block protectio n
All blocks protected at power-up
Any combination of blocks can be protected
with zero latency
Absolute Write Protection with VPP = VSS
Security
Software security features
64-bit unique device number
2112-bit user programmable OTP Cells
Common Flash Interface (CFI)
100 000 program/ erase cycles per block
Electronic signature
Manufacturer code: 20h
Top device codes:
M58LT128HST: 88D6h
Bottom device codes
M58LT128HSB: 88D7h
TBGA64 package
ECOPACK® complia nt
TBGA64 (ZA)
10 × 13 mm
BGA
www.st.com
Contents M58LT128HST, M58LT128HSB
2/110
Contents
1 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2 Signal descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
2.1 Address inputs (A0-A22) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
2.2 Data inputs/outputs (DQ0-DQ15) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
2.3 Chip Enable (E) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
2.4 Output Enable (G) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
2.5 Write Enable (W) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
2.6 Reset (RP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
2.7 Latch Enable (L) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.8 Clock (K) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.9 Wait (WAIT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.10 VDD supply voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.11 VDDQ supply voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.12 VPP program supply vo ltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.13 VSS ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2.14 VSSQ ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
3 Bus operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
3.1 Bus Read . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
3.2 Bus Write . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
3.3 Address Latch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
3.4 Output Disable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
3.5 Standby . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
3.6 Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
4 Command interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
4.1 Read Array command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
4.2 Read Status Register command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
4.3 Read Electronic Signature command . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
4.4 Read CFI Query command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
4.5 Clear Status Register command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
M58LT128HST , M58LT128HSB Contents
3/110
4.6 Block Erase command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
4.7 Blank Check command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
4.8 Program command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
4.9 Buffer Program command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
4.10 Buffer Enhanced Factory Program command . . . . . . . . . . . . . . . . . . . . . 24
4.10.1 Setup phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
4.10.2 Program and verify phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
4.10.3 Exit phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
4.11 Program/Erase Suspend command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
4.12 Program/Erase Resume command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
4.13 Protection Register Program command . . . . . . . . . . . . . . . . . . . . . . . . . . 27
4.14 Set Configuration Register command . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
4.15 Block Protect command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
4.16 Block Unprotect command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
5 Status Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
5.1 Program/Erase Controller status bit (SR7) . . . . . . . . . . . . . . . . . . . . . . . . 33
5.2 Erase Suspend status bit (SR6) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
5.3 Erase/Blank Check status bit (SR5) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
5.4 Program status bit (SR4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
5.5 VPP status bit (SR3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
5.6 Program Suspend status bit (SR2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
5.7 Block Protection status bit (SR1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
5.8 Bank Write/Multiple Word Program status bit (SR0) . . . . . . . . . . . . . . . . 35
6 Configuration Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
6.1 Read Select bit (CR15) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
6.2 X-Latency bits (CR13-CR11) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
6.3 Wait Polarity bit (CR10) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
6.4 Data Output Configuration bit (CR9) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
6.5 Wait Configuration bit (CR8) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
6.6 Burst Type bit (CR7) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
6.7 Valid Clock Edge bit (CR6) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
6.8 Wrap Burst bit (CR3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Contents M58LT128HST, M58LT128HSB
4/110
6.9 Burst length bits (CR2-CR0) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
7 Read modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
7.1 Asynchronous Read mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
7.2 Synchronous Burst Read mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
7.2.1 Synchronous Burst Read Suspend . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
7.3 Single Synchronous Read mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
8 Dual operations and Multiple Bank architecture . . . . . . . . . . . . . . . . . 47
9 Block protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
9.1 Reading a block’s protection status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
9.2 Protected state . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
9.3 Unprotected state . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
9.4 Protection operations during Erase Suspend . . . . . . . . . . . . . . . . . . . . . . 50
10 Program and erase times and endurance cycles . . . . . . . . . . . . . . . . . 51
11 Maximum rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
12 DC and AC parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
13 Package mechanical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
14 Part numbering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
Appendix A Block address tables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
Appendix B Common Flash Interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
Appendix C Flowcharts and pseudo codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
Appendix D Command interface state tables. . . . . . . . . . . . . . . . . . . . . . . . . . . 100
Revision history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109
M58LT128HST , M58LT128HSB List of tables
5/110
List of tables
Table 1. Signal names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Table 2. Bank architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Table 3. Bus operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Table 4. Command codes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Table 5. Standard commands. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Table 6. Factory commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Table 7. Electronic signature codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Table 8. Protection Register locks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Table 9. Status Register bits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Table 10. X-Latency Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Table 11. Configuration Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Table 12. Burst type definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Table 13. Dual operations allowed in other banks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Table 14. Dual operations allowed in same bank. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Table 15. Dual operation limitations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Table 16. Program/Erase times and endurance cycles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Table 17. Absolute maximum ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Table 18. Operating and ac measurement conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Table 19. Capacitance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Table 20. DC characteristics - currents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Table 21. DC characteristics - voltages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Table 22. Asynchronous Read ac characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Table 23. Synchronous Read ac characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Table 24. Write ac characteristics, Write Enable controlled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Table 25. Write ac Characteristics, Chip Enable Controlled. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
Table 26. Reset and Power-up ac characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Table 27. TBGA64 10 × 13 mm - 8 × 8 active ball array, 1 mm pitch, package
mechanical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Table 28. Ordering information scheme . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
Table 29. Top boot block addresses, M58LT128HST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
Table 30. Bottom boot block addresses, M58LT128HSB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
Table 31. Query structure overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
Table 32. CFI query identification string . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
Table 33. CFI query system interface information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
Table 34. Device geometry definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
Table 35. Primary algorithm-specific extended query table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
Table 36. Protection Register information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
Table 37. Burst Read information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
Table 38. Bank and Erase Block region information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
Table 39. Bank and Erase Block region 1 information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
Table 40. Bank and Erase Block Region 2 Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
Table 41. Command Interface states - modify table, next state . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
Table 42. Command Interface states - modify table, next output state . . . . . . . . . . . . . . . . . . . . . . 103
Table 43. Command interface states - lock table, next state . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
Table 44. Command interface states - lock table, next output state . . . . . . . . . . . . . . . . . . . . . . . . 107
Table 45. Document revision history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109
List of figures M58LT128HST, M58LT128HSB
6/110
List of figures
Figure 1. Logic diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Figure 2. TBGA64 package connections (top view through package). . . . . . . . . . . . . . . . . . . . . . . . 10
Figure 3. Memory map. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Figure 4. Protection Register memory map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Figure 5. X-latency and data output configuration example. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Figure 6. Wait configuration example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Figure 7. AC measurement I/O waveform . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Figure 8. AC measurement load circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Figure 9. Asynchronous random access Read ac waveforms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Figure 10. Asynchronous Page Read ac waveforms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Figure 11. Synchronous Burst Read ac waveforms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Figure 12. Single Synchronous Read ac waveforms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Figure 13. Synchronous Burst Read Suspend ac waveforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Figure 14. Clock input ac waveform. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Figure 15. Write ac waveforms, Write Enable controlled. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Figure 16. Write ac waveforms, Chip Enable controlled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Figure 17. Reset and Power-up ac waveforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Figure 18. TBGA64 10 × 13 mm - 8 × 8 active ball array, 1 mm pitch, bottom view
package outline. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 0
Figure 19. Program flowchart and pseudo code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
Figure 20. Blank Check flowchart and pseudo code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
Figure 21. Buffer Program flowchart and pseudo code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
Figure 22. Program Suspend & Resume flowchart and pseudo code. . . . . . . . . . . . . . . . . . . . . . . . . 94
Figure 23. Block Erase flowchart and pseudo code. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
Figure 24. Erase Suspend & Resume flowchart and pseudo code . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
Figure 25. Protect/Unprotect operation flowchart and pseudo code . . . . . . . . . . . . . . . . . . . . . . . . . . 97
Figure 26. Protection Register Program flowchart and pseudo code . . . . . . . . . . . . . . . . . . . . . . . . . 98
Figure 27. Buffer Enhanced Factory Program flowchart and pseudo code . . . . . . . . . . . . . . . . . . . . . 99
M58LT128HST, M58LT128HSB Description
7/110
1 Description
The M58LT128HST/B are 128 Mbit (8 Mbit x16) non-volatile Secure Flash memories. They
may be erased electrically at block level and programmed in-system on a w ord-by-word
basis using a 1.7 V to 2.0 V VDD supply f or the circuitry and a 2.7 V to 3.6 V VDDQ supply for
the Input/Output pins. An optional 9 V VPP power supp ly is provided to sp ee d up factory
programming.
The devices feature an asymmetrical block architecture. The M58LT128HST/B have an
array of 131 blocks, and are divided into 8 Mbit banks. There are 15 banks each containing
8 main blocks of 64 Kwords, and one parameter bank containing 4 parameter blocks of 16
Kwords and 7 main blocks of 64 Kwords.
The Multiple Bank Architecture allows Dual Operations, while programming or erasing in
one bank, read ope rations ar e possible in ot her banks . Only one bank at a time is allo wed to
be in program or erase mode. It is possible to perform burst reads that cross bank
boundaries. The bank architecture is summarized in Table 2, and the memory map is shown
in Figure 3. The Parameter Blocks are located at the top of the memory address space f or
the M58LT128HST, and at the bottom for the M58LT128HSB.
Each block can be erased separately. Erase can be suspended, in order to perform a
program or read operation in any other bl ock, and then resumed. Program can be
suspended to read data at any memory location except fo r th e on e being p rogrammed, and
then resumed . Each block can be programmed and erased over 100,000 cycles using the
supply voltage VDD. There is a Buffer Enhanced Factory programming command available
to speed up programming.
Program and erase commands are written to the Command Interface of the memory. An
internal Program/Erase Controller takes care of the timings necessary for program and
erase operations. The end of a program or erase operation can be detected and any error
conditions identified in the Status Register. The command set required to control the
memory is consistent with JEDEC standards.
The device supports Synchronous Burst Read and Asynchronous Read from all blocks of
the memory array; at power-up the device is configured for Asynchronous Read. In
Synchronous Burst Read mode, data is output on each clock cycle at frequencies of up to
52 MHz. The Synchronous Burst Read operation can be suspended and resumed.
The device features an Automatic Standby mode. When the bus is inactive during
Asynchronous Read oper ations, t he device aut omatically s witches to the Automatic Standby
mode. In this condition the power consumption is reduced to the standby value and the
outputs are still driven.
The M58LT128HST/B f eatures a n instant, individual b lock p rotection scheme that allo ws any
bl ock to be protected or unprot ected with no latency, enabling instant code and data
protection. They can be protected individually preventing any accidental programming or
erasure . The re is an ad ditional hard war e protectio n against prog ram a nd er ase . When V PP
VPPLK all blocks are protected against program or erase. All blocks are protected at power-
up.
The de vice includes 17 Protection Registers and 2 Protection Register locks , one f or the fir st
Protection Register and the other for the 16 One-Time-Programmable (OTP) Protection
Registers of 128 bits each. The first Protect ion Register is divided into two segments: a 64
bit segment containing a unique device number written by ST, and a 64 bit segment One-
Description M58LT128HST, M58LT128HSB
8/110
Time-Programmable (OTP) by the user. The user programmable segment can be
permanently prot ec te d. Figure 4, shows the Protection Register me mory map.
The M58LT128HST/B also has a full set of Softw are security f eatur es that are not described
in this datasheet, but are documented in a dedicated Application Note. For further
information please contact STMicroelectronics.
The M58LT128HST/B are offered in a TBGA64, 10 × 13 mm, 1 mm pitch pac kage . The y are
supplied with all the bits erased (set to ’1’).
M58LT128HST, M58LT128HSB Description
9/110
Figure 1. Logic diagram
Table 1. Signal names
Signal name Function Direction
A0-A22 Address inputs Inputs
DQ0-DQ15 Data input/outputs, command inputs I/O
EChip Enable Input
GOutput Enable Input
WWrite En able Input
RP Reset Input
K Clock Input
LLatch Enable Input
WAIT Wait Output
VDD Supply voltage Input
VDDQ Supply voltage for input/output buffers Input
VPP Optional supply voltage for fast program & erase Input
VSS Ground
VSSQ Ground input/output supply Input
NC Not Connected Internally
DU Do Not Use
AI12887
A0-A22
W
DQ0-DQ15
VDD
M58LT128HST
M58LT128HSB
E
VSS
16
G
RP
VDDQ VPP
L
K
WAIT
VSSQ
Description M58LT128HST, M58LT128HSB
10/110
Figure 2. TBGA64 package connections (top view through package)
AI10270b
DQ6
A0
VSSQ
VDD
DQ10
VDD
DQ7
DQ5VDDQ
DQ2
H
DQ14
VSS
DQ13
D A15
A19
EA8
C
A16
A20
A10
A14
K
A7
B A18A1
A12
A13
A
87654321
A6A2
A3 A4
G
F
E
DQ0
A5 VPP A17
A9 A11
RP
DQ15DQ9DQ8 DQ1 DQ4DQ3
GDQ12DQ11
W
VSS NC
NC
NC NC
NC
NC
NC NC
NC
A21
A22
WAIT
NC
NC
L
M58LT128HST, M58LT128HSB Description
11/110
Figure 3. Memory map
Table 2. Bank architecture
Number Bank Size Parameter Blocks Main Blocks
Parameter Bank 8 Mbits 4 bloc ks of 16 Kwords 7 blocks of 64 Kwords
Bank 1 8 Mbits - 8 blocks of 64 Kwords
Bank 2 8 Mbits - 8 blocks of 64 Kwords
Bank 3 8 Mbits - 8 blocks of 64 Kwords
----
----
----
----
Bank 14 8 Mbits - 8 blocks of 64 Kwords
Bank 15 8 Mbits - 8 blocks of 64 Kwords
AI12888
M58LT128HST - Top Boot Block
Address lines A0-A16
8 Main
Blocks
Bank 15
M58LT128HSB - Bottom Boot Block
Address lines A0-A16
64 KWord
000000h
00FFFFh
64 KWord
070000h
07FFFFh
64 KWord
600000h
60FFFFh
64 KWord
670000h
67FFFFh
64 KWord
680000h
68FFFFh
64 KWord
6F0000h
6FFFFFh
64 KWord
700000h
70FFFFh
64 KWord
770000h
77FFFFh
64 KWord
780000h
78FFFFh
64 KWord
7E0000h
7EFFFFh
16 KWord
7F0000h
7F3FFFh
16 KWord
7FC000h
7FFFFFh
4 Parameter
Blocks
Parameter
Bank
Parameter
Bank
16 KWord
000000h
003FFFh
16 KWord
00C000h
00FFFFh
64 KWord
010000h
01FFFFh
64 KWord
070000h
07FFFFh
64 KWord
080000h
08FFFFh
64 KWord
0F0000h
0FFFFFh
64 KWord
100000h
10FFFFh
64 KWord
170000h
17FFFFh
64 KWord
180000h
18FFFFh
64 KWord
1F0000h
1FFFFFh
64 KWord
780000h
78FFFFh
64 KWord
7F0000h
7FFFFFh
Bank 3
Bank 2
Bank 1
Bank 15
Bank 3
Bank 2
Bank 1
8 Main
Blocks
8 Main
Blocks
8 Main
Blocks
7 Main
Blocks
4 Parameter
Blocks
7 Main
Blocks
8 Main
Blocks
8 Main
Blocks
8 Main
Blocks
8 Main
Blocks
Signal descriptions M58LT128HST, M58LT128HSB
12/110
2 Signal descriptions
See Figure 1: Logic diagram and Table 1: Signal names, for a brief overview of the signals
connected to this device.
2.1 Address inputs (A0-A22)
The Address Inputs select the cells in the me mory array to access during Bus Read
operations. During Bus Write operations they control the commands sent to the Command
Interface of the Program/ Erase Controller.
2.2 Data inputs/outputs (DQ0-DQ15)
The Data I/O outp ut the data stored at th e selected address during a Bus Read oper ation or
input a command or the data to be prog rammed during a Bus Write operation.
2.3 Chip Enable (E)
The Chip Enable input activates the memory control logic, input buffers, decoders and
sense amplifiers. When Chip Enable is at VILand Reset is at VIH the device is in active
mode. When Chip Enable is at VIH the memory is deselected, the outputs are high
impedance and the power consumption is reduced to the standby level.
2.4 Output Enable (G)
The Output Enable input controls data outputs during the Bus Read operation of the
memory.
2.5 Write Enable (W)
The Write Enable input controls the Bus Write operation of the memory’s Command
Interface. The data and address inputs are latched on the rising edge of Chip Enable or
Write Enable whichever occurs first.
2.6 Reset (RP)
The Reset input provides a hardware reset of the memory. When Reset is at VIL, the
memory is in reset mode: the outputs are high impedance and the current consumption is
reduced to the Reset Supply Current IDD2. Refer to Table 20: DC characteristics - currents,
for the value of IDD2. After Reset all blocks are in the Protected state and the Configuration
Register is reset. When Reset is at VIH, the device is in normal operation. Exiting reset
mode the device enters asynchronous read mode, but a negative transition of Chip Enable
or Latch Enable is required to ensure valid data outputs.
M58LT128HST, M58LT128HSB Signal descriptions
13/110
2.7 Latch Enable (L)
Latch Enable latches the address bits on its rising edge. The address latch is transparent
when Latch Enable is at VIL and it is inhibited when Latch Enable is at VIH.
2.8 Clock (K)
The clock input synchronizes the memory to the microcontroller during synchronous read
operat ions; the address is latched on a Clock edge (rising or falling, according to the
configuration settings) when Latch Enable is at VIL. Clock is ignored during asynchronous
read and in write operations.
2.9 Wait (WAIT)
Wait is an output signal used during synchronous read to indicate whether the data on the
output bus are valid. This output is high im pe da n ce when C hip Enable is at VIH, Output
Enable is at VIH or Reset is at VIL. It can be configured to be ac tive during the wait cycle or
one cloc k cycle in advance.
2.10 VDD supply voltage
VDD provides the power supply to the internal core of the memory device. It is the main
power supply for all operations (Read, Prog ram and Erase).
2.11 VDDQ supply voltage
VDDQ provides the power supply to the I/O pins and enables all Outputs to be powered
independently fr om VDD.
2.12 VPP program supply voltage
VPP is both a control input and a power supply pin. The two functions are selected by the
voltage range applied to the pin.
If VPP is kept in a low v oltage ra nge (0V to VDDQ) VPP is seen as a control input. In this case
a voltage lo wer than VPPLK gives absolute protection against program or erase, while VPP in
the VPP1 range enables these function s (se e Tables 20 and 21, DC Characteristics for the
rele vant v alues). VPP is only sampled at the begin ning of a progr am or era se; a change in its
value after the operation has started does not have any effect and program or erase
operat ions continue .
If VPP is in the range of VPPH it acts as a power supply pin. In this condition VPP must be
stable until the Program/Erase alg orithm is completed.
Signal descriptions M58LT128HST, M58LT128HSB
14/110
2.13 VSS ground
VSS ground is the reference for the core supply. It must be connected to the system ground.
2.14 VSSQ ground
VSSQ ground is the reference for the input/output circuitry driven by VDDQ. VSSQ must be
connected to VSS
Note: Each device in a system should have VDD, VDDQ and VPP decoupled with a 0.1µF ceramic
capacitor close t o the pin (high freq uency, inherently lo w inductance capacitors should be as
close as possible to the package). See Figure 8: AC measurement load circuit. The PCB
track widths should be sufficient to carry the required VPP progr am and erase currents.
M58LT128HST, M58LT128HSB Bus operations
15/110
3 Bus operations
There are six standard bus operations that control the device. These are Bus Read, Bus
Write, Address Latch, Output Disable, Standby and Reset. See Table 3: Bus operations, for
a summar y.
Typically glitches of less than 5ns on Chip Enable or Write Enable are ignored by the
memory and do not affect Bus Write operations.
3.1 Bus Read
Bus Read oper ations are used to output the contents of the Memory Array, the Electronic
Signature, the Status Register and the Common Flash Interface. Both Chip Enable and
Output Enable must be at VIL in order to perform a read operation. The Chip Enab le input
should be used to enable the device. Output Enable should be used to gate data onto the
output. The data read depends on the previous command written to the memory (see
Command Interf a ce section). See Figur es 9, 10 and 11 Read A C W a v ef orms, and Tab les 22
and 23 Read AC Characteristics , for details of when the output becomes va lid.
3.2 Bus Write
Bus Write operations write Commands to the memory or latch Input Data to be
programmed. A bus write operation is initiated when Chip Enable and Write Enable are at
VIL with Output Enable at VIH. Commands, Input Data and Addresses are latched on the
rising edge of Write Enable or Chip Enable, whichever occurs first. The addresses must be
latched prior to the write operation by toggling Latch Enable (when Chip Enable is at VIL).
The Latch Enable must be tied to VIH during the bus write operation.
See Figures 15 and 16, Write AC Waveforms, and Tables 24 and 25, Write AC
Characteristics, for details of the timing requirements.
3.3 Address Latch
Address latch operations input valid addresses. Both Chip enab le and Latch Enab le must be
at VIL during address latch operations. The a ddresses are latched on the rising edge of
Latch Enable.
3.4 Output Disable
The outputs are h igh impedance when the Output Enab le is at VIH.
Bus operations M58LT128HST, M58LT1 28HSB
16/110
3.5 Standby
Standb y disab les most of the internal circuitry allowing a substantial reduction of the cu rrent
consumption. The memory is in standb y when Chip Enable and Reset are at VIH. The pow er
consumption is re duced to the stand by le v el I DD3 and th e outputs are set to high impedan ce,
independently from the Output Enable o r Write Enable inputs . If Chip Enable switches to VIH
during a program or erase operation, the device enters Standby mode when finished.
3.6 Reset
During Reset mode the memory is deselected and the outputs are high impedance. The
memory is in Reset mode when Reset is at VIL. The power consumption is reduced to the
Reset level, independently from the Chip Enable, Output Enable or Write Enable inputs. If
Reset is pulled to VSS during a Progra m or Er ase , this oper ation is aborted and the memory
content is no longer valid.
Table 3. Bus operations(1)
1. X = Don't care.
Operation E G W L RP WAIT(2)
2. WAIT signal polarity is configured using the Set Configuration Register command.
DQ15-DQ0
Bus Read VIL VIL VIH VIL(3)
3. L can be tied to VIH if the valid address has been previously latched.
VIH Data Output
Bus Write VIL VIH VIL VIL(3) VIH Data Input
Address Latch VIL XV
IH VIL VIH Data Output or Hi-Z(4)
4. Depends on G.
Output Disable VIL VIH VIH XV
IH Hi-Z Hi-Z
Standby VIH XXXV
IH Hi-Z Hi-Z
Reset XXXXV
IL Hi-Z Hi-Z
M58LT128HST , M58LT128HSB Command interface
17/110
4 Command interface
All Bus Write operations to the memory are interpreted by the Command Interface.
Commands consist of one or more sequential Bus Write operations. An inter nal
Program/Erase Controller handles all timings and verifies the correct execution of the
program and erase commands. The Program/Erase Controller provides a Status Register
whose output ma y be read at any time to monitor the progress or the result of the operation.
The Command Inte rface is re set to read mode when po wer is first app lied, when ex iting from
Reset or whene ver VDD is lo wer than VLKO. Command sequences must be follow ed exactly.
Any invalid combination of commands will be ignored.
Refer to Tabl e 4: Command codes, Tab le 5: Standard commands, Table 6: Factory
commands, and App endix D: Command interface state tables, for a summary of the
Command Interface.
Table 4. Command codes
Hex Code Command
01h Block Protect Confirm
03h Set Configuration Register Confirm
10h Alternative Program Setup
20h Block Erase Setup
40h Program Setup
50h Clear Status Register
60h Block Protect Setup, Block Unprotect Setup and Set Configuration Register
Setup
70h Read Status Register
80h Buffer Enhanced Factory Program Setup
90h Read Electronic Signature
98h Read CFI Query
B0h Program/Erase Suspend
BCh Blank Check Setup
C0h Protection Register Program
CBh Blank Check Confirm
D0h Program/Erase Resume, Block Erase Confirm, Block Unprotect Confirm, Buffer
Program or Buffer Enhanced Factory Program Confirm
E8h Buffer Program
FFh Read Array
Command interface M58LT128HST, M58LT128HSB
18/110
4.1 Read Array command
The Read Array command returns the addressed bank to Read Array mode.
One Bus Write cycle is required to issue the Read Array command. Once a bank is in Read
Array mode, subsequent read operations will output the data from the memory array.
A Read Array command can be issued to any banks while programming or erasing in
another bank.
If the Read Array command is issued to a bank currently executing a program or erase
operation, the bank will return to Read Array mode but the program or erase operation will
continue, however the data output from the bank is not guaranteed until the program or
erase operation has finished. The read modes of other banks are not affected.
4.2 Read Status Register command
The device contains a Status Register that is used to monitor program or erase operations.
The Read Status Register command is use d to read the contents of the Status Register for
the addresse d ba n k.
One Bus Write cycle is required to issue the Read Status Register command. Once a bank
is in Read Status Register mode, subsequent read operations will output the contents of the
Status Register.
The Status Register data is latched on the f a lling edge of the Chip Enable or Output Enable
signals. Eith er Chip Enab le or Output Enab le must be toggled to upd ate the Status Regi ster
data
The Read Status Register command can be issued at any t ime, even during program or
erase operations. The Read Status Register command will only change the read mode of
the addresse d ba n k. Th e re a d mode s of other banks are not affected. Only Asynchron ou s
Read and Single Synchronous Re ad operation s should be used to read t he Status Register.
A Read Array command is required to return the bank to Read Array mode.
See Table 9 for the description of the Status Register Bits.
M58LT128HST , M58LT128HSB Command interface
19/110
4.3 Read Electronic Signature command
The Read Electronic Signature command is used to read the Manufacturer and Device
Codes, the Protection Status of the addressed bank, the Protection Register, and the
Configuration Regist er.
One Bus Write cycle is required to issue the Read Electronic Signature command. Once a
bank is in Read Electronic Signature mode, subsequent read op erations in the same bank
will output the Manuf acturer Code , the De vice Code , the Protection Status of the addressed
bank, the Protection Register, or the Configuration Register (see Table 8).
The Read Electronic Signatu re command can be issued at any time , e ven during prog ram or
erase operations, except during Protection Register Program operations. Dual operations
between the Parameter bank and the Electronic Signature location are not allowed (see
Table 15: Dual operation limitations for details).
If a Read Electronic Signature command is issued to a bank that is executing a program or
erase operation the bank will go into Read Electronic Signature mode. Subsequent Bus
Read cycles will output the Electronic Signature data and the Program/Erase controller will
continue to program or erase in the background.
The Read Electronic Signature command will only change the read mode of the addressed
bank. The read mod es of other banks are not af fect ed. Only Asynchronous Read and Sin gle
Synchronous Read operations should be used to read the Electronic Signature. A Read
Array command is required to return the bank to Read Array mode.
4.4 Read CFI Query command
The Read CFI Query command is used to read data from the Common Flash Interface
(CFI).
One Bus Write cycle is required to issue the Read CFI Query command. Once a bank is in
Read CFI Query mode, subsequent Bus Read o perations in the same bank read from the
Common Flash Interface.
The Read CFI Query command can be issued at any time, even during program or erase
operations.
If a Read CFI Query command is issued to a bank that is executing a program or erase
operation the bank will go into Read CFI Query mode. Subsequent Bus Read cycles will
output the CFI data and the Program/Erase controller will continue to program or erase in
the background.
The Read CFI Query command will only change t he read mode of the addre ssed bank. The
read modes of othe r banks ar e no t affected. Only Asynch ro no u s Rea d an d Single
Synchronous Read operations should be used to read from the CFI. A Read Array
command is required to return the bank to Read Array mode. Dual operations between the
Parameter Bank and the CFI memory space are not allowed (see Table 15: Dual operation
limitations for details).
See Appendix B: Common Flash Interface, Tables 31, 32, 33, 34, 35, 36, 37, 38, 39 and 40
for details on the information contained in the Common Flash Interface memory area.
Command interface M58LT128HST, M58LT128HSB
20/110
4.5 Clear Status Register command
The Clear Status Register command can be used to reset (set to ‘0’) all error bits (SR1, 3, 4
and 5) in the Stat us Register.
One Bus Write cycle is required to issue the Clear Status Re gister command. The Clear
Status Register command does not affect the read mode of the bank.
The error b its in th e Status Register do not aut omatically return to ‘0’ when a ne w comman d
is issued. The error bits in the Status Register should be cleared before attempting a new
program or erase command.
4.6 Block Erase command
The Bloc k Erase command is used to erase a block. It sets all the bits within the selected
block to ’1’. All previous data in the block is lost.
If the block is protected then the erase operation will abor t, the data in the block will not be
changed and the Status Register will output the error.
Two Bus Write cycles are required to issue the command.
The first bus cycle sets up the Block Erase command.
The second latches the bl ock address and starts the Program/Erase Controller.
If the second bus cycle is not the Block Erase Confirm code , Status Register bits SR4 and
SR5 are set and the command is a borted.
Once the command is issued the b ank enters Read Status Register mode and any read
operation within the addressed bank will output the contents of the Status Register. A Read
Array command is required to return the bank to Read Array mode.
During Block Erase oper ations the bank containing the block being erased will only accept
the Read Array, Read Status Register, Read Electronic Signature, Read CFI Query and the
Program/Erase Suspend command, all other commands will be ignored.
The Block Erase operation aborts if Reset, RP, goes to VIL. As data integrity cannot be
guaranteed when the Block Erase operation is aborted, the block must be erased again.
Refe r to Dual Operations section for detailed information about simultaneous operations
allowed in banks not being erased.
Typical Erase times are given in Table 16: Program/Erase times and endurance cycles.
See Appendix C, Figure 23: Bloc k Erase flowchart and pseudo code, for a sugges te d
flowchart for using the Block Erase command.
M58LT128HST , M58LT128HSB Command interface
21/110
4.7 Blank Check command
The Blank Check command is used to check whether a Block has been completely erased.
Only one Block at a time can be checked. To use the Blank Check command VPP must be
equal to VPPH. If VPP is not equal to VPPH, the device ignores the command and no er ror is
shown in the Status Register.
Two bus cycles are required to issue the Blank Check command:
The first bus cycle writes the Blank Check command ( BCh) to any address in the Bloc k
to be checked.
The second b us cycle writes the Blank Chec k Co nfirm command (CBh) to any address
in the Bloc k to be checked and starts the Blank Check operation.
If the second bus cycle is not Blank Check Confirm, Status Register bits SR4 and SR5 are
set to '1' and the command aborts.
Once the command is issued the addressed bank automatically enters the Status Register
mode and further reads within the bank output the Status Register contents.
The only operation permitted during Blank Check is Read Status Register. Dual Operations
are not supported while a Blank Check operation is in progress. Blank Check operations
cannot be suspended and are not allowed while the device is in Program/Erase Suspend.
The SR7 Status Register bit indicates the status of the Blank Check operation in progress:
SR7 = '0' means that the Blank Check operation is still ongoing. SR7 = '1' means that the
operation is complete.
The SR5 Status Register bit goes High (SR5 = '1') to indicate that the Blank Check
operat ion has failed.
At the end of th e operation th e bank remains in the Read Sta tus Register mode until a nother
command is written to the Command Interface.
See Appendix C, Figure 20: Blank Check flowchart and pseudo code, for a su ggested
flowchart for using the Blank Check command.
Typical Blank Check times are given in Table 16: Program/Erase times and endurance
cycles.
Command interface M58LT128HST, M58LT128HSB
22/110
4.8 Program command
The program command is used to program a single word to the memory array.
If the block being programmed is protected, then the Program operation will abort, the data
in the block will not be changed and the Status Register will output the error.
Two Bus Write cycles are required to issue the Program Command.
The first bus cycle sets up the Program command.
The second latches the address and dat a to be programmed and starts the
Program/Erase Controller.
Once the programming ha s started, read operations in the bank being programmed output
the Status Register content.
During a Program operation, the bank containing the word being programmed will only
accept the Read Array, Read Status Register, Read Electronic Signature , Read CFI Query
and the Program/Erase Suspend command, all other commands will be ignored. A Read
Array command is required to return the bank to Read Array mode.
Refe r to Dual Operations section for detailed information about simultaneous operations
allowed in banks not being programmed.
Typical Program times are given in Table 16: Program/Erase times and endurance cycles.
The Program operation aborts if Reset, RP, goes to VIL. As data integrity cannot be
guaranteed when the Program operation is aborted, the word must be reprogrammed.
See Ap pendix C, Fi gure 19: Progr am f lo wch art and pseudo code, for the flowchart f or using
the Program command.
M58LT128HST , M58LT128HSB Command interface
23/110
4.9 Buffer Program command
The Buffer Program Co mmand ma kes use of the de vice’s 32-word Write Buffer to speed up
programming. Up to 32 words can be loaded into the Write Buffer. The Buffer Program
command dram atically reduces in-system prog ramming ti me compared to the st andard non-
buffered Program command.
F our successive steps are required to issue the Buffer Program command.
1. The first Bus Write cycle sets up t he Buffer Program command. Th e setup code can be
addressed to any location within the targeted block.
After the first Bus Write cycle, read operations in the bank will output the contents of the
Status Register. Status Re gister bit SR7 should be read to check that the buffer is available
(SR7 = 1). If the buffer is not a vailable (SR7 = 0), re-issue the Buffer Program command to
update th e Status Register contents.
2. The second Bus Write cycle sets up the n umber of w ords to be prog rammed. Value n is
written to the same block addr ess, where n+1 is the number of words to be
programmed.
3. Use n+1 Bus Write cycles to load the address and data for each word into the Write
Buff er . Addresse s must lie within the r ange from the start addre ss to the start address +
n, where the start address is the location of the first data to be programmed. Optim um
performance is obtained when the start address corresponds to a 32 word boundary.
4. The final Bus Write cycle confirms the Buffer Program command and starts the
program operation.
All the addresses used in the Buffer Program oper ation must lie within the same bloc k.
Invalid address combinations or failing to follow the correct sequence of Bus Write cycles
will set an error in the Status Register and abort the operation without affecting the data in
the memory array.
If the bloc k being programmed is protected an error will be set in the Status Register and the
operation will abort without affecting the data in the memory array.
During Buffer Program operations the bank being programmed will only accept the Read
Array, Read Status Register, Read Electronic Signature, Read CFI Query and the
Program/Erase Suspend command, all other commands will be ignored.
Refe r to Dual Operations section for detailed information about simultaneous operations
allowed in banks not being programmed.
See Appendix C, Figure 21: Buffer Program flowchart and pseudo code, for a suggested
flowchart on using the Buffer Program command.
Command interface M58LT128HST, M58LT128HSB
24/110
4.10 Buffer Enhanced Factory Program command
The Buff er Enhanced Factory Program command ha s been specially de v eloped to speed up
programming in manufacturing environments where the programming time is critical.
It is used to program one or more Write Buffer(s) of 32 words to a block. Once the device
enters Buffer Enhanced Factory Program mode, the Write Buffer can be reloaded any
number of times as long as the address remains within the same block. Only one block can
be programmed at a time.
If the block being programmed is protected, then the Program operation will abort, the data
in the block will not be changed and the Status Register will output the error.
The use of the Buffer Enhanced Factory Program command requires certain operating
conditions:
VPP must be set to VPPH
VDD must be within operating range
Ambient temperature TA must be 30°C ± 10°C
The targeted block must be unprotected
The start address must be aligned with the start of a 32 word buffer boundary
The address must remain the Start Address throughout programming.
Dual operations are not supported during the Buffer Enhanced Factory Program operation
and the command cannot be susp ended.
The Buffer Enhanced Factory Program Command consists of three phases: the Setup
Phase, t he Program and Verify Phase, and the Exit Phase, Please refer to Table 6: Factory
commands for detail information.
4.10.1 Setup phase
The Buffer Enhanced Factory Program command requires two Bus Write cycles to initiate
the command.
The first Bus Write cycle sets up the Buffer Enhanced Factory Program command.
The second Bus Write cycle confirms the command.
After the confirm command is issued, read operations output the contents of the Status
Register. The read Status Register command must not be issued as it will be interpreted as
data to program.
The Status Register P/E.C. Bit SR7 should be read to check that the P/E.C. is ready to
proceed to the next phase.
If an error is detected , SR4 goes hig h (set to ‘1’) and the Buffer Enhanced Factory Prog ram
operat ion is terminated. See Status Register section for details on the error.
M58LT128HST , M58LT128HSB Command interface
25/110
4.10.2 Program and verify phase
The Program and Verify Phase requires 32 cycles to program the 32 words to the Write
Buffer. The data is stored sequent ially, starting at the first address of the Write Buffer, until
the Write Buffer is full (32 words). To progr am less than 32 words, the remaining words
should be progra mmed with FFFFh.
Three successive steps are required to issue and execute the Program and Verify Phase of
the command.
1. Use one Bus Write operation to latch the Start Address and the first word to be
programmed. The Status Register Bank Write Status bit SR0 should be read to check
that the P/E.C. is ready for the next word.
2. Each subsequent word to be programmed is latched with a new Bus Write operation.
The address m ust remain the Start Address as the P/E.C. increments the address
location.If any address that is not in the same blo ck as the Start Address is given, the
Progr am and Verify Phase te rminates . Status Register bit SR0 should be rea d between
each Bus Write cycle to check that the P/E.C. is ready f or the next word.
3. Once the Write Buffer is full, the data is progr a mmed seque ntially t o the memory array.
After the prog ram operation th e device automat ically verifies the data and repro grams if
necessary.
The Program and Verify phase can be repeated, without re-issuing the command, to
program additional 32 word locations as long as the address remains in the same block.
4. Finally, after all words , or the ent ir e block ha ve been progr amme d, write one Bus Write
operatio n to any address outside the block containing the Start Address, to terminate
Program and Verify Phase.
Status Register bit SR0 must be checked to determine whether the program operation is
finished. The Status Register may be checked for errors at any time but it must be chec ked
after the entire block has been programmed.
4.10.3 Exit phase
Status Register P/E.C. bit SR7 set to ‘1’ indicates that the device has exit ed the Buffer
Enhanced Factory Program operation and returned to Read Status Register mode. A full
Status Register check should be done to ensure that the block has been successfully
programmed. See the section on the Status Register for more details.
For optimum performance the Buffer Enhanced Factory Program command should be
limited to a maximum of 100 program/erase cycles per block. If this limit is e xceeded the
internal algorithm will continue to work properly but some degradation in performance is
possible. Typical program times are given in Table 16.
See Appendix C, Figur e 27: Buffer Enhanced Factory Program f lowchart and pseudo code,
for a suggested flowchart on using the Buffer Enhanced Factory Program command.
Command interface M58LT128HST, M58LT128HSB
26/110
4.11 Program/Erase Suspend command
The Program/Erase Suspend command is used to pause a Program or Block Erase
operation. The command can be addressed to any bank.
The Program/Erase Resume command is required to restar t the suspended operation.
One bus write cycle is required to issue the Program/Erase Suspend command. Once the
Program/Er ase Controller has paused bits SR7, SR6 and/ or SR2 of the Status Register will
be set to ‘1’.
The following commands are accepted during Program/Erase Suspend:
Program/Erase Resume
Read Array (data from erase-suspended bl ock or program-suspended word is not
valid)
Read Status Register
Read Electronic Signature
Read CFI Query
Additionally, if the susp ended operation was a Bloc k Erase t hen the f ollowing command s are
also accepted:
Clear Status Register
Program (except in erase-suspended block)
Buffer Program (except in erase suspended blocks)
Block Protect
Block Unprotect
Set Configuration Register
During an erase suspend the block being erased can be protected by issuing the Block
Protect command. When the Progra m/Erase Resume command is issued the operation will
complete.
It is possib le to accumulate multiple suspend operations. For example: suspend an erase
operation, start a prog ram operation, suspend the progr am operation, then read the array.
If a Prog ram command is issued during a Bloc k Er ase Su spend, t he er ase oper ation ca nnot
be resumed until the program operation has completed.
The Prog ram/Er ase Suspe nd command d oes not chang e the rea d mode of the ba nks. If the
suspended bank was in Read Status Register, Read Electronic signature or Read CFI
Query mode the bank remains in that mode and outputs the corresponding data.
Refe r to Dual Operations section for detailed information about simultaneous operations
allowed during Pro gram/Erase Suspen d.
During a Program /Erase Suspend, the de vice can be placed in standby mode b y taking Chip
Enable to VIH. Program/erase is aborted if Reset, RP, goes to VIL.
See Appendix C, Figure 22: Program Suspend & Resume flowchart and pseudo code, and
Figure 24: Erase Suspend & Resume flowchart and pseudo code, for flowcharts for using
the Program/Erase Suspend command.
M58LT128HST , M58LT128HSB Command interface
27/110
4.12 Program/Erase Resume command
The Program/Erase Resume command is used to restart the program or erase operation
suspended by the Program/Er ase Suspend command. One Bus Write cycle is required to
issue the command. The command can be issued to any address .
The Program/Erase Resume command doe s n ot ch an ge t he read m ode of th e banks. If the
suspended bank was in Read Status Register, Read Electronic signature or Read CFI
Query mode the bank remains in that mode and outputs the corresponding data.
If a Program command is issued during a Block Erase Suspend, then the era se cannot be
resumed until the program operation ha s completed.
See Appendix C, Figure 22: Program Suspend & Resume flowchart and pseudo code, and
Figure 24: Erase Suspend & Resume flowchart and pseudo code, for flowcharts for using
the Program/Erase Resume command.
4.13 Protection Register Program command
The Protection Register Program command is used to program the user One-Time-
Programmable (OTP) segments of the Protection Register and the two Protection Register
Locks.
The device features 16 OTP segments of 128 bits and one OTP segment of 64 bits, as
shown in Figure 4: Protection Register memory map.
The segments are programmed one word at a time. When shipped all bits in the segment
are set to ‘1’. The user can only program the bits to ‘0’.
Two Bus Write cycles are required to issue the Protection Register Program command.
The first bus cycle sets up the Protection Register Program command.
The second latches the addre ss and data to be prog rammed to the Protection Register
and starts the Program/Erase Controller.
Read operat ions to the bank being prog rammed out put the Status Register content after the
program operation has started.
Attempting to program a previously protected Protection Register will result in a Status
Register error.
The Protection Register Program cannot be suspended. Dual operations between the
Parameter Bank and the Protection Register memory space are not allowed (see Table 15:
Dual operation limitations for details)
The two Protection Register Locks are used to protect the OTP segments from further
modification. The protection of the OTP segments is not reversible. Refer to Figure 4:
Protection Register memory map, and Table 8: Protection Register locks, for details on the
Lock bits.
See Appendix C, Figure 26: Protection Regist er Program flowchart and pseu d o code, for a
flo wchart for using the Protection Register Program command.
Command interface M58LT128HST, M58LT128HSB
28/110
4.14 Set Configuration Register command
The Set Configuration Register command is used to write a new value to the Configuration
Register.
Two Bus Write cycles are required to issue the Set Configuration Register command.
The first cycle sets up the Set Configuration Register command and the address
corresponding to the Configuration Register content.
The second cycle writes the Configuration Register data and the confirm command.
The Configuration Register data must be written as an address during the bus write cycles,
that is A0 = CR0, A1 = CR1, …, A15 = CR15. Addresses A16-A22 are ignored.
Read operations output the array content after the Set Configuration Register command is
issued.
The Read Electronic Signature command is required to read the updated contents of the
Configuration Regist er.
4.15 Block Protect command
The Block Protect command is used t o protect a b lock and prev ent program or erase
operations from changing the data in it. All blocks are protected after power-up or reset.
Two Bus Write cycles are required to issue the Block Protect command.
The first bus cycle sets up the Block Protect command.
The second Bus Write cycle latches the block address and protects the block.
Once the command has been issu ed subsequent Bus Read operations read the Statu s
Register.
The protection status can be monitored for each block using the Read Electronic Signature
command.
Refer to Section 9: Block protection, for a detailed explanation. See Appendix C, Figure 25:
Protect/Unprotect operation flowchart and pseudo code, for a flowchart fo r usin g th e Block
Protect command.
4.16 Block Unprotect command
The Block Unprotect command is used to unprotect a block, allowing the block to be
programmed or erased.
Two Bus Write cycles are required to issue the Block Unprotect command.
The first bus cycle sets up the Block Unprotect command.
The second Bus Write cycle latches the block address and unprotects the block.
Once the command has been issu ed subsequent Bus Read operations read the Statu s
Register.
The protection status can be monitored for each block using the Read Electronic Signature
command.
Refer to Section 9: Block protection, for a de ta iled explanation and Appendix C, Figure 25:
Protect/Unprotect operation flowchart and pseudo code, for a flowchart fo r usin g th e Block
Unprotect command.
M58LT128HST , M58LT128HSB Command interface
29/110
Table 5. Standard commands(1)
1. X = Don't Care, WA = word Address in targeted bank, RD =Read Data, SRD =Status Register Data, ESD =
Electronic Signature Data, QD =Query Data, BA =Block Address, BKA = Bank Address, PD = Program
Data, PRA = Protection Register Address, PRD = Protection Register Data, CRD = Configuration Register
Data.
Commands
Cycles
Bus operations
1st cycle 2nd cycle
Op. Add Data Op. Add Data
Read Array 1+ Write BKA FFh Read WA RD
Read Status Register 1+ Write BKA 70h Read BKA(2)
2. Must be same bank as in the first cycle. The signature addresses are listed in Table 7.
SRD
Read Electronic Signature 1+ Write BKA 90h Read BKA(2) ESD
Read CFI Query 1+ Write BKA 98h Read BKA(2) QD
Clear Status Register 1 Write X 50h
Block Erase 2 Write BKA or
BA(3)
3. Any address within the bank can be used.
20h Write BA D0h
Program 2 Write BKA or
WA(3) 40h or
10h Write WA PD
Buffer Program(4)
4. n+1 is the number of words to be programmed.
n+4
Write BA E8h Write BA n
Write PA1PD1Write PA2PD2
Write PAn+1 PDn+1 Write X D0h
Program/Erase Suspend 1 Write X B0h
Program/Erase Resume 1 Write X D0h
Protection Register Program 2 Write PRA C0h Write PRA PRD
Set Configuration Register 2 Write CRD 60h Write CRD 03h
Block Protect 2 Write BKA or
BA(3) 60h Write BA 01h
Block Unprotect 2 Write BKA or
BA(3) 60h Write BA D0h
Command interface M58LT128HST, M58LT128HSB
30/110
Table 6. Factory commands
Command Phase
Cycles
Bus Write operations(1)
1. WA = word Address in targeted bank, BKA = Bank Address, PD =Program Data, BA = Block Address, X =
Don’t Care.
1st 2nd 3rd Final -1 Final
Add Data Add Data Add Data Add Data Add Data
Blank
Check 2 BA BCh BA CBh
Buffer
Enhanced
Factory
Program
Setup 2 BKA or
WA(2)
2. Any address within the bank can be used.
80h WA1D0h
Program/
Verify(3)
3. The Program/Verify phase can be executed any number of times as long as the data is to be programmed
to the same block.
32 WA1PD1WA1PD2WA1PD3WA1PD31 WA1PD32
Exit 1 NOT
BA1(4)
4. WA1 is the Start Address, NOT BA1 = Not Block Address of WA1.
X
Table 7. Electronic signature codes
Code Address (h) Data (h)
Manufacturer code Bank Address + 000 0020
Device code Top Bank Address + 001 88D6 (M58LT128HST)
Bottom Bank Address + 001 88D7 (M58LT128HSB)
Block Protection Protected Block Address +
002 0001
Unprotected 0000
Configuration Register Bank Address + 005 CR(1)
1. CR = Configuration Register, PRLD = Protection Register Lock Data.
Protection Register
PR0 Lock
ST Factory Default Bank Address + 080 0002
OTP Area Permanently
Protected 0000
Protection Register PR0
Bank Address + 081
Bank Address + 084 Uni que Device Number
Bank Address + 085
Bank Address + 088 OTP Area
Protection Register PR1 throu gh PR16 Lock Bank Address + 089 PRLD(1)
Protection Registers PR1-PR16 Bank Address + 08A
Bank Address + 109 OTP Area
M58LT128HST , M58LT128HSB Command interface
31/110
Figure 4. Protect ion Register memory map
AI07563
User Programmable OTP
Unique device number
Protection Register Lock 1 0
88h88h
85h
84h
81h
80h
User Programmable OTP
PROTECTION REGISTERS
User Programmable OTP
Protection Register Lock 1043297513 12 1011 8 6
14
15
PR1
PR16
PR0
89h
8Ah
91h
102h
109h
Command interface M58LT128HST, M58LT128HSB
32/110
Table 8. Protection Register locks
Lock Description
Number Address Bits
Lock 1 80h
Bit 0 preprogrammed to protect Unique Device Number, address
81h to 84h in PR0
Bit 1 protects 64bits of OTP segment, address 85h to 88h in PR0
Bits 2 to 15 reserved
Loc k 2 89h
Bit 0 protects 128bits of OTP segment PR1
Bit 1 protects 128bits of OTP segment PR2
Bit 2 protects 128bits of OTP segment PR3
----
----
Bit 13 protects 128bits of OTP segment PR14
Bit 14 protects 128bits of OTP segment PR15
Bit 15 protects 128bits of OTP segment PR16
M58LT128HST, M58LT128HSB Status Register
33/110
5 Status Register
The Status Register provides information on th e current or previous program or erase
operations. Issue a Read Status Register command to read the contents of the Status
Register, refer to Read Status Register Command section for more details. To output the
contents, the Status Register is latched and updated on the falling edge of the Chip Enable
or Output Enab le signals and can be read until Ch ip Enable or Out put Enable re turns to VIH.
The Status Register can only be read using single Asynchronous or Single Synchronous
reads. Bus Read operations from any address within the bank always read the Status
Register during program and erase operat ions if no Read Array command has been issued.
The various bits convey information about the status and any errors of the operation. Bits
SR7, SR6, SR2 and SR0 give inf ormation on the status of the device and are set and reset
by the device. Bits SR5, SR4, SR3 and SR1 give information on errors, they are set by the
device but must be rese t by issuing a Clear Status Register command or a hardware reset.
If an error bit is set to ‘1’ the Status Register should be reset before issuing another
command.
The bits in the Status Register are summarized in Table 9 : Status Register bits. Refer to
Table 9 in conjunction with the following text descriptions.
5.1 Program/Erase Controller status bit (SR7)
The Program/Erase Controller Status bit indicates whether the Program/Erase Controller is
active or inactive in any bank.
When the Program/Erase Controller Status bit i s Low (set to ‘0’), the Progr am/Erase
Controller is active ; when the bit is High (set to ‘1’), the Program/Erase Controller is inactiv e,
and the device is ready to process a new command.
The Program/Erase Controller Status bit is Low immediately after a Program/Erase
Suspend command is issued until the Program/Erase Controller pauses. After the
Program/Erase Controller pauses the bit is High.
5.2 Erase Suspend status bit (SR6)
The Erase Susp end Status bit indicates that an e rase operatio n has been suspended. Wh en
the Erase Suspend Status bit is High (set to ‘1’), a Program/Erase Suspend command has
been issued and the memory is waiting for a Program/Erase Resume command.
The Erase Suspend Status bit should only be considered valid when the Program/Erase
Controller Status bit is High (Progr am/Erase C ontroller inactiv e). SR6 is set within the Erase
Suspend Latency time of the Progr am/Er ase Suspend comm and being issued therefore the
memor y may still complete the operation rather than entering the Suspend mode.
When a Program/Erase Resume command is issued the Erase Suspend Status bit returns
Low.
Status Register M58LT128HST, M58LT128HSB
34/110
5.3 Erase/Blank Check status bit (SR5)
The Erase/Blank Check Status bit is used to identify if there was an error during a Block
Erase operation. When the Erase/Blank Check Status bit is High (set to ‘1’), the
Program/Erase Controller has applied the maximum number of pulses to the block and still
failed to verify that it has erased correctly.
The Erase/Bla nk Check Status bit should be read once the Prog ram/Er ase Controller Status
bit is High (Program/Erase Controller inactive).
The Erase/Blank Check Status bit is also used to indicate whether an er ror occurred during
the Blank Chec k oper ati on: if t he data at on e or more location s in th e b l oc k whe re the Bla nk
Check command has been issued is different from FFFFh, SR5 is set to '1'.
Once set High, the Erase/Blank Check Status bit must be set Low by a Clear Status
Register command or a hardware reset before a new erase command is issued, otherwise
the new command will appear to fail.
5.4 Program status bit (SR4)
The Program Status bit is used to identify if there was an error during a progr am operation.
The Progr am Status bit should be read once the Prog ram/Er ase Controller Sta tus bit is High
(Program/Erase Controller inactive).
When the Program Status bit is High (set to ‘1’), the Program/Erase Controller has applied
the maximum number of pulses to the word and still failed to verify that it has programmed
correctly.
Attempting to program a '1' to an alread y pr og rammed bit while VPP = VPPH will also set the
Program Status bit High. If VPP is different from VPPH, SR4 remains Low (set to '0') and the
attempt is not shown.
Once set High, the Program Status bit must be set Low by a Clear Status Register
command or a har dware reset b efor e a new pro gram command is issued, otherwise the ne w
command will appear to fail.
5.5 VPP status bit (SR3)
The VPP Status bit is used to identify an invalid voltage on the VPP pin during program and
erase operations . The VPP pin is only sampled at the beginning of a program or erase
operation. Program and erase operations are not guaranteed if VPP becomes invalid during
an operation
When the VPP Status bit is Low (set to ‘0’), the v oltage on the VPP pin w as sampled at a v alid
voltage.
When the VPP Status bit is High (set to ‘1’), the VPP pin has a voltage that is below the VPP
Lock out Voltage, VPPLK, the memory is protected and progr am and er ase oper ations cann ot
be performed.
Once set High, the VPP Status bit must be set Low by a Clear Status Register command or
a hardware reset before a new program or erase command is issued, otherwise the new
command will appear to fail.
M58LT128HST, M58LT128HSB Status Register
35/110
5.6 Program Suspend status bit (SR2)
The Program Suspend Status bit indicates that a program operation has been suspended.
The Program Suspend Status bit should only be considered valid when the Progr am/Erase
Controller Status bit is High (Program/Erase Controller inactive).
When the Program Suspend Status bit is High (set to ‘1’), a Program/Erase Suspend
command has been issued and the memory is waiting for a Program/Erase Resume
command.
SR2 is set within the Program Suspend Latency time of the Progr am/Erase Suspend
command being issued therefore the memory ma y still complete the oper ation rather than
entering the Suspend mode.
When a Program/Erase Resume command is issued the Program Suspend Status bit
returns Low.
5.7 Block Protection status bit (SR1)
The Bloc k Protection Status bit is used to identi fy if a Progr am or Bloc k Er ase oper ation has
tried to mod ify th e contents of a protecte d block.
When the Block Protection Status bit is High (set to ‘1’), a program or erase operation has
been attempt ed on a protected block.
Once set High, the Block Protection Status bit must be set Low by a Clear Status Register
command or a hardware reset before a new program or erase command is issued,
otherwise the new command will appear to fail.
5.8 Bank Write/Multiple Word Program status bit (SR0)
The Bank Write Status bit indicates whether the addressed bank is pro gramming or erasing.
In Buffer Enhanced Factory Program mode the Multiple Word Program bit sh ows if the
device is ready to accept a new word to be programmed to the memory array.
The Bank Write Status bit should only be considered valid when the Program/Erase
Controller Status SR7 is Low (set to ‘0’).
When both the Program/Erase Controller Status bit and the Bank Write Status bit are Low
(set to ‘0’), the addressed bank is executing a program or erase operation. When the
Program/Erase Controller Status bit is Low (set to ‘0’) and the Bank Write Status bit is High
(set to ‘1’), a program or erase operation is being executed in a bank other than the one
being addres se d.
In Buff er Enhanced F act ory Progr am mode if Multiple W ord Program Sta tus bit is Low (set to
‘0’), the de vice is read y f or the ne xt word , if the Multiple W ord Pr ogram Sta tus bit is High (set
to ‘1’) the device is not ready for the next word.
F or f urther details on how to u se the St atus Reg ister, see the Flowcharts and Pseudocodes
provided in Appendix C.
Status Register M58LT128HST, M58LT128HSB
36/110
Table 9. Status Register bits
Bit Name Type Logic
Level(1)
1. Logic level '1' is High, '0' is Low.
Definition
SR7 P/E.C. Status Status '1' Ready
'0' Busy
SR6 Erase Suspend
Status Status '1' Erase Suspended
'0' Erase In progress or Completed
SR5 Erase/Blank Check
Status Error '1' Erase/Blank Check Error
'0' Erase/Blank Check Success
SR4 Program Status Error '1' Program Error
'0' Program Success
SR3 VPP Status Error '1' VPP Invalid, Abort
'0' VPP OK
SR2 Program Suspend
Status Status '1' Program Suspended
'0' Program In Progress or Completed
SR1 Block Protection
Status Error '1' Program/Erase on protected Block, Abort
'0' No operation to protected blocks
SR0
Bank Write Status Status
'1' SR7 = ‘1’ Not Allowed
SR7 = ‘0’ Program or erase operation in a bank
other than the addressed bank
'0' SR7 = ‘1’ No Program or erase operation in the
device
SR7 = ‘0’ Program or erase operation in
addressed bank
Multiple Word
Program Status
(Buffer Enhanced
Factory Program
mode)
Status
'1'
SR7 = ‘1’ Not Allowed
SR7 = ‘0’ the device is NOT ready for the next
Buffer loading or is going to exit the
BEFP mode
'0' SR7 = ‘1’ the device has exited the BEFP mode
SR7 = ‘0’ the de vice is ready f or the ne xt Buff er
loading
M58LT128HST, M5 8LT128HSB Configuration Register
37/110
6 Configuration Register
The Configuration Register is used to configure the type of bus access that the memory will
perform. Refer to Read Modes section for details on read operations.
The Configuration Register is set through the Command Int erface using the Set
Configuration Register command. After a reset or power-up the device is configured for
asynchronous read (CR15 = 1). The Configuration Register bits are described in Table 11
They specify the selection of the burst length, burst type, burst X latency and the read
operat ion. Refer to Figures 5 and 6 for examples of synchronous b urst configurations.
6.1 Read Select bit (CR15)
The Read Select bit, CR15, is used to switch between Asynchronous and Synchronous
Read operations.
When the Read Select bit is set to ’1’, read operations are asynch ronous; when the Re ad
Select bit is set to ’0’, read operations are synchronous.
Synchronous Burst Read is supported in both parameter and main blocks and can be
performed across banks.
On reset or power-up the Read Select bit is set to ’1’ for asynchronous access.
6.2 X-Latency bits (CR13-CR11)
The X-Latency bits are used during Synchrono us Read operations to set the number of
clock cycles between the address being latche d and the f irst data be coming a v ailab le . Ref er
to Figure 5: X-latency and data ou tput configuration example.
For correct operation the X-Latency bits can only assume the values in Table 11:
Configuration Regist er.
Table 10 shows how to set the X-Latency parameter, taking into account the speed class of
the device and the Frequency used to read the Flash memory in Synchronous mode.
Table 10. X-Latency Settings
fmax tKmin X-Latency min
30 MHz 33 ns 3
40 MHz 25 ns 4
52 MHz 19 ns 5
Configuration Register M58LT128HST, M58LT128HSB
38/110
6.3 Wait Polarity bit (CR10)
The Wait P o larity bit is used to set the po larity of the Wait signal used in Synchronous Burst
Read mode. During Synchronous Burst Read mode the Wait signal indicates whether the
data output are valid or a WAIT st at e must be ins ert ed .
When the Wait Polarity bit is set to ‘0’ the Wait signal is active Low. When the Wait Polarity
bit is set to ‘1’ the Wait signal is active High.
6.4 Data Output Configuration bit (CR9)
The Data Output Configuration bit is used to configure the output to remain valid fo r either
one or two clock cycles during synchronous mode.
When the Data Output Configuration Bit is ’0’ the output data is valid for one clock cycle,
when the Data Output Configuration Bit is ’1’ the output data is valid for two clock cycles.
The Data Output Configuration must be configured using the following condition:
tK > tKQV + tQVK_CPU
where
tK is the clock period
tQVK_CPU is the data setup time required by the system CPU
tKQV is the clock to data valid time.
If this condition is not satisfied, the Data Output Configuration bit should be set to ‘1’ (two
clock cycles). Refer to Figure 5: X-latency and data output configuration example.
6.5 Wait Configuration bit (CR8)
The Wait Configuration bit is used to control the timing of the Wait output pin, WAIT, in
Synchronous Burst Read mode.
When WAIT is asserted, Data is Not Valid and when WAIT is de-asserted, Data is Valid.
When the Wait Configur at ion bit is Low (set to ’0’) the Wait output pin is asserted during the
WAIT state. When the Wait Configuration bit is High (set to ’1’), the Wait output pin is
asserted one data cycle before the WAIT state.
6.6 Burst Type bit (CR7)
The Burst Type bit determines the sequence of addresses read during Synchronous Burst
Reads.
The Burst Type bit is High (set to ’1’), as the memory outputs from sequential addresses
only.
See Table 12: Burst type definition, for the sequence of addresses output from a given
starting address in sequential mode.
M58LT128HST, M5 8LT128HSB Configuration Register
39/110
6.7 Valid Clock Edge bit (CR6)
The Valid Clock Edge bit, CR6, is used to configure the active edge of the Clock, K, during
synchronous read operations. When the Valid Clock Edge bit is Low (set to ’0’) the falling
edge of the Clock is the active edge. When the Valid Clock Edge bit is High (set to ’1’) the
rising edge of the Clock is the active edge.
6.8 Wrap Burst bit (CR3)
The Wrap Burst bit, CR3, is used to select b etween wrap and no wrap. Synchronous burst
reads can be confined inside the 4, 8 or 16 word boundary (wrap) or ov ercome the boundary
(no wrap).
When the Wrap Burst bit is Low (set to ‘0’) the burst read wraps. When it is High (set to ‘1’)
the burst read does not wrap.
6.9 Burst length bits (CR2-CR0)
The Burst Length bits are used to set the number of words to be output during a
Synchronous Burst Read operation as re sult of a single address latch cycle.
The y can be set for 4 words , 8 w ords, 16 word s or contin uous b urst, wher e all the w ords are
read sequent ially. In continuous b ur st mo de t he burst sequence can cross bank boundaries .
In continuous burst mode, in 4, 8 or 16 words no-wrap, depending on the starting address,
the device asserts the WAIT signa l to indic at e that a de lay is necessary before the data is
output.
If the starting address is shifted by 1, 2 or 3 positions from the four-word boundary, WAIT is
asserted for 1, 2 or 3 clock cycles, respectively, when the burst sequence crosses the first
16-word bou ndary, to indicate that the de vice needs an internal dela y to read the successiv e
words in the array. WAIT will be asserted only once during a continuous burst access. See
also Table 12: Burst type definition.
CR14, CR5 and CR4 are reserved for future use .
Configuration Register M58LT128HST, M58LT128HSB
40/110
Table 11. Configuration Register
Bit Description Value Description
CR15 Read Select 0 Synchronous Read
1 Asynchronous Read (Default at power-on)
CR14 Reserved
CR13-CR11 X-Latency
010 2 clock latency (1)
1. The combination X-Latency=2, Data held for two clock cycles and Wait active one data cycle before the
WAIT state is not supported.
011 3 clock latency
100 4 clock latency
101 5 clock latency
110 6 clock latency
111 7 clock latency (default)
Other configurations reserved
CR10 Wait Polarity 0 WAIT is active Low
1 WAIT is active High (default)
CR9 Data Output
Configuration 0 Data held for one clock cycle
1 Data held for tw o clock cycles (default)(1)
CR8 Wait Configuration 0 WAIT is active during WAIT state
1WAIT is active one data cycle before WAIT
state(1) (default)
CR7 Burst Type 0Reserved
1 Sequential (default)
CR6 Valid Clock Edge 0 Falling Clock edge
1 Rising Clock edge (default)
CR5-CR4 Reserved
CR3 Wrap Burst 0Wrap
1 No Wrap (default)
CR2-CR0 Burst Length
001 4 words
010 8 words
011 16 words
111 Continuous (default)
M58LT128HST, M5 8LT128HSB Configuration Register
41/110
Table 12. Burst type definition
Mode
Start
Add
Sequential Continuous Burst
4 words 8 words 16 wo rds
Wrap
0 0-1-2-3 0-1-2-3-4-5-6-
70-1-2-3-4-5-6-7-8-9-10-
11-12-13-14-15 0-1-2-3-4-5-6...
1 1-2-3-0 1-2-3-4-5-6-7-
01-2-3-4-5-6-7-8-9-10-
11-12-13-14-15-0 1-2-3-4-5-6-7-...15-WAIT-16-17-
18...
2 2-3-0-1 2-3-4-5-6-7-0-
12-3-4-5-6-7-8-9-10-11-
12-13-14-15-0-1 2-3-4-5-6-7...15-WAIT-WAIT-16-
17-18...
3 3-0-1-2 3-4-5-6-7-0-1-
23-4-5-6-7-8-9-10-11-12-
13-14-15-0-1-2 3-4-5-6-7...15-WAIT-WAIT-
WAIT-16-17-18...
...
7 7-4-5-6 7-0-1-2-3-4-5-
67-8-9-10-11-12-13-14-
15-0-1-2-3-4-5-6 7-8-9-10-11-12-13-14-15-WAIT-
WAIT-WAIT-16-17...
...
12 12-13-14-15-16-17-18...
13 13-14-15-WAIT-16-17-18...
14 14-15-WAIT-WAIT-16-17-18....
15 15-WAIT-WAIT-WAIT-16-17-18...
Configuration Register M58LT128HST, M58LT128HSB
42/110
No-wrap
0 0-1-2-3 0-1-2-3-4-5-6-
70-1-2-3-4-5-6-7-8-9-10-
11-12-13-14-15
Same as for Wr ap
(Wrap /No Wrap has no effect
on Continuous Burst)
1 1-2-3-4 1-2-3-4-5-6-7-
8
1-2-3-4-5-6-7-8-9-10-
11-12-13-14-15-WAIT-
16
2 2-3-4-5 2-3-4-5-6-7-8-
9...
2-3-4-5-6-7-8-9-10-11-
12-13-14-15-WAIT-
WAIT-16-17
3 3-4-5-6 3-4-5-6-7-8-9-
10
3-4-5-6-7-8-9-10-11-12-
13-14-15-WAIT-WAIT-
WAIT-16-17-18
...
7 7-8-9-10 7-8-9-10-11-
12-13-14
7-8-9-10-11-12-13-14-
15-WAIT-WAIT-WAIT-
16-17-18-19-20-21-22
...
12 12-13-14-
15 12-13-14-15-
16-17-18-19
12-13-14-15-16-17-18-
19-20-21-22-23-24-25-
26-27
13 13-14-15-
WAIT-16
13-14-15-
WAIT-16-17-
18-19-20
13-14-15-WAIT-16-17-
18-19-20-21-22-23-24-
25-26-27-28
14
14-15-
WAIT-
WAIT-16-
17
14-15-WAIT-
WAIT-16-17-
18-19-20-21
14-15-WAIT-WAIT-16-
17-18-19-20-21-22-23-
24-25-26-27-28-29
15
15-WAIT-
WAIT-
WAIT-16-
17-18
15-WAIT-
WAIT-WAIT-
16-17-18-19-
20-21-22
15-WAIT-WAIT-WAIT-
16-17-18-19-20-21-22-
23-24-25-26-27-28-29-
30
Table 12. Burst type definition (continued)
Mode
Start
Add
Sequential Continuous Burst
4 words 8 words 16 wo rds
M58LT128HST, M5 8LT128HSB Configuration Register
43/110
Figure 5. X-latency and data output configuration example
1. The settings shown are X-latency = 4, Data Output held for one clock cycle.
Figure 6. Wait configuration example
AI10542
A22-A0 VALID ADDRESS
K
L
DQ15-DQ0 VALID DATA
X-latency
VALID DATA
tACC
tAVK_CPU tKtQVK_CPU
tQVK_CPUtKQV
1st cycle 2nd cycle 3rd cycle 4th cycle
E
tDELAY
AI06972
A22-A0 VALID ADDRESS
K
L
DQ15-DQ0 VALID DATA
WAIT
CR8 = '0'
CR10 = '0'
WAIT
CR8 = '1'
CR10 = '0'
VALID DATA NOT VALID VALID DATA
E
WAIT
CR8 = '0'
CR10 = '1'
WAIT
CR8 = '1'
CR10 = '1'
Read modes M58LT128HST, M58LT128HSB
44/110
7 Read modes
Read operations can be performed in two different ways depending on the settings in the
Configuration Register. If the clock signal is ‘don’t care’ for the data output, the read
operation is asynchronous; if the data output is synchronized with clock, the read opera tion
is synchronous.
The read mode a nd format of th e data output are d etermined b y the Co nfigu rat ion Regist er.
(See Section 6: Configuration Regist er f or details). All banks support both asynchronous
and synchronous read operations.
7.1 Asynchronous Read mode
In Asynchronous Read operations the clock signal is ‘don’t care’. The device outputs the
data corresponding to the addr ess latched, that is the memory array, Status Register,
Common Flash Interface or Electronic Signat ur e d epend ing on the comm and issued . CR15
in the Configuration Register must be set to ‘1’ for asynchronous operations.
Asynchronous Read operations can be performed in two different ways, Asynchronous
Random Access Read and Asynchronous Page Read. Only Asynchrono u s Page Read
tak es full advantage of the internal page storage so different timings are applied.
In Asynchronous Read mode a Page of data is internally read and stored in a Page Buffer.
The Page has a size of 4 words and is addressed b y address inputs A0 and A1. The first
read operation within the Page has a longer access time (tAVQV, Random access time),
subsequent reads within the same Page have much shorter access times (tAVQV1, Page
access time). If the Page changes then the normal, longer timings apply again.
The device features an Automatic Standby mode. During Asynchronous Read operations,
after a bus inactivity of 150ns, the device automatically switches to the Automatic Standby
mode. In this condition the power consumption is reduced to the standby value and the
outputs are still driven.
In Asynchronou s Read mode, the WAIT signal is always de-asserted.
See Table 22: Asynchronous Read ac characteristics , Figure 9: Asynchronous random
access Read ac waveforms, and Figure 10: Asynchronous Page Read ac waveforms for
details.
M58LT128HST, M58LT128HSB Read mo des
45/110
7.2 Synchronous Burst Read mode
In Synchronous Burst Read mode the da ta is output in b ursts synch ronized with the cloc k. It
is possibl e to perform burst reads across bank boundaries.
Synchronous Burst Read mode can only be used to read the memory array. For other read
operat ions , such as Read Status Re gister, Read CFI and Rea d Electron ic Signature , Single
Synchronous Read or Asynchronous Random Access Read must be used.
In Synchronous Burst Read mode the flow of the data output depends on para meters that
are configured in the Configuration Register.
A burst sequence starts at the first clock edge (rising or falling depending on Valid Clock
Edge bit CR6 in the Configuration Register) after the falling edge of Latch Enable or Chip
Enable, whichever occurs last. Addresses are internally incremented and data is ou tput on
each data cycle after a delay which depends on the X latency bits CR13-CR11 of the
Configuration Regist er.
The number of words to be out put during a Synchronous Bur st Read operation can be
configured as 4 wo rds, 8 words, 16 wor ds or Continuous (Burst Length bits CR2-CR0). The
data can be configured to remain valid for one or two clock cycles (Data Output
Configuration bit CR9).
The order of the dat a output can be modified th rough the Wrap Bur st bit in the Configura tion
Register. The burst sequence is sequential and can be confined inside the 4, 8 or 16 word
boundary (Wrap) or overcome the boundary (No Wrap).
The WAIT signal may be asserted to indicate to the system that an output delay will occur.
This delay will depend on the starting address of the burst sequence and on the burst
configuration.
WAIT is asserted during the X latency, the WAIT state and at the end of a 4, 8 and 16 word
burst. It is only de-asserted when output data are valid or when G is at VIH. In Continuous
Burst Read mode a WAIT state will occur when crossing the first 16 word boundary. If the
starting address is a ligne d to t he Bu rst L engt h (4, 8 or 1 6 w o rd s) th e wrapped configuration
has no impact on the output sequence.
The WAIT signal can be configured to be active Low or active High by setting CR10 in the
Configuration Regist er.
See Table 23: Synchronous Read ac characteristics, and Figure 11: Synchronous Burst
Read ac waveforms, for details.
Read modes M58LT128HST, M58LT128HSB
46/110
7.2.1 Synchronous Burst Read Suspend
A Synchronous Burst Read operation can be suspended, freeing the data bus for other
higher priority de vices. It can be suspended during the initial access latency time (before
data is output) or after the device has output data. When the Synchronous Burst Read
operation is suspend ed, internal arra y sensing continu es and any pre viously latched internal
data is retained. A burst sequence can be suspended and re sumed as often as required as
long as the operating conditions of the device are met.
A Synchronous Burst Read operation is suspended when Chip Enable, E, is Low and the
current address has been latched (on a Latch Enable rising edge or on a valid clock edge).
The Clock signal is then halted at VIH or at VIL, and Output Enable, G, goes High.
When Output Enable, G, becomes Low again and the Clock signal restarts, the
Synchronous Burst Read operation is resumed exactly where it stopped.
WAIT will revert to high-impedance whenever Chip Enable, E, or Output Enable, G, goes
High.
See Table 23: Synchronous Read ac characteristics, and Figure 13: Synchronous Burst
Read Suspend ac waveforms, for details.
7.3 Single Synchronous Read mode
Single Synchronous Read operations are similar to Synchronous Burst Read op erations
except that the memory outputs the same data to the end of the operation.
Synchronous Single Reads are used to read th e Electronic Sign at ure, Status Register, CFI,
Block Protection Status, Configuration Register Status or Protection Register. When the
addressed bank is in Read CF I, Read Status Regist er or Read Electronic Signature mod e,
the W AIT sign al is asserted during the X-latency, the W AIT state and a t the end of a 4, 8 and
16 word burst. It is only de-asserted when output data are valid.
See Table 23: Synchronous Read ac characteristics, and Figure 12: Single Synchronous
Read ac waveforms, for details.
M58LT128HST, M58LT128HSB Dual operations and Multiple Bank architecture
47/110
8 Dual operations and Multiple Bank architecture
The Multiple Bank Architecture of the M58LT128HST/B gives greater flexibility for software
de velopers to split the code and data spaces with in the m emory arra y. The Dual Operations
feature simplifies the software management of the device by allowing code to be executed
from one bank while another bank is being programmed or erased.
The Dual Opera tions feature means that while programming or erasing in one bank, read
operations a re possible in anot her bank with zero la tency (only one bank at a time is a llowed
to be in prog ram or erase mode).
If a read operation is required in a bank, which is programming or erasing, the program or
erase operation can be suspended.
Also if the suspended operation was erase then a program command can be issued to
another b loc k, so the de vice can ha v e on e blo c k in Erase Suspend mode , one prog rammin g
and other banks in read mode.
Bus Read operations are allowed in another bank between setup and confirm cycles of
program or erase operations.
By using a combination of these f eatures , read oper ations are possib le at an y moment in the
M58LT128HST/B device.
Dual operations between the Parameter Bank and either of the CFI, the OTP or the
Electronic Signature memory space are not allow ed. Table 15 shows which dual operations
are allowed or not between the CFI, the OTP, the Electronic Signature locations and the
memory array.
Tables 13 and 14 show the dual operations possible in other banks and in the same bank.
Table 13. Dual operations allowed in other banks
Status of bank
Commands allowed in another bank
Read
Array
Read
Status
Register
Read
CFI
Query
Read
Electronic
Signature
Program,
Buffer
Program
Block
Erase
Program
/Erase
Suspend
Program
/Erase
Resume
Idle Yes Yes Yes Yes Yes Yes Yes Yes
Programming Yes Yes Yes Yes Yes
Erasing Yes Yes Yes Yes Yes
Program
Suspended Yes Yes Yes Yes Yes
Erase
Suspended Yes Yes Yes Yes Yes Yes
Dual operations and Multiple Bank architecture M58LT128HST, M58LT128HSB
48/110
Table 14. Dual operations allowed in same bank
Status of bank
Commands allowed in same bank
Read
Array
Read
Status
Register
Read
CFI
Query
Read
Electronic
Signature
Program,
Buffer
Program
Block
Erase
Program
/Erase
Suspend
Program
/Erase
Resume
Idle Yes Yes Yes Yes Yes Yes Yes Yes
Programming (1)
1. The Read Array command is accepted but the data output is not guaranteed until the Program or Erase
has completed.
Yes Yes Yes Yes
Erasing (1) Yes Yes Yes Yes
Program
Suspended Yes(2)
2. The Read Array command is accepted but the data output is not guaranteed in the Block that is being
erased, or in the word that is being programmed.
Yes Yes Yes Yes
Erase
Suspended Yes(2) Yes Yes Yes Yes(3)
3. Not allowed in the Block that is being erased or in the word that is being programmed.
––Yes
Table 15. Dual operation limitations
Current Status
Commands allowed
Read CFI / O TP /
Electronic
Signature
Read
Parameter
Blocks
Read Main Blocks
Located in
Parameter
Bank
Not Located
in Parameter
Bank
Programming / Erasing
Parameter Blocks No No No Yes
Programming /
Erasing Main
Blocks
Located in
Parameter
Bank Yes No No Yes
Not Located
in P ar ameter
Bank Yes Yes Yes In Different
Bank Only
Programming OTP No No No No
M58LT128HST , M58LT128HSB Block protection
49/110
9 Block protection
The M58LT128HST/B f eatures an instant, indi vidual bloc k protection scheme t hat allows an y
bl ock to be protected or unprotected with no latency. This protection scheme has two levels
of protection.
Protect/Unprotect - this first level allows software only control of block protection.
VPP VPPLK - the second level offers a complete hardware protection against program
and erase on all blocks.
The protection st atus of each blo ck can be set to Protected and Unprotected. Appendix C,
Figure 25, shows a flowchart for the protection operations.
9.1 Reading a block’s protection status
The protection status of every block can be read in the Read Electronic Signature mode of
the device. To enter this mode issue the Read Electronic Signature command. Subsequent
reads at the addre ss sp ecif ied in Table 7, will output the protection status of that block.
The protection status is represented by DQ0. DQ0 indicates the Block Protect/Unprotect
status and is set by the Protect comm a nd and cleared by the Unprotect command.
The following sections explain the operation of the protection system.
9.2 Protected state
The default status of all blocks on pow er-up or after a ha rdware re set is Protected (state =
1). Protected blocks are fully protected from program or erase operations. Any program or
erase operations attempted on a protected block will return an error in the Status Register.
The Status of a Protected block can be changed to Unprotected using the appropriate
software commands. An Unprotected block can be Protected by issuing the Protect
command.
9.3 Unprotected state
Unprotected b loc ks (state = 0 ), can be prog rammed or erased . All unprote cted b loc ks return
to the Protecte d state after a hardware reset or when the device is powered-down. The
status of an unprotected block can be changed to Protected using the appropriate software
commands . A protected block can be unprotected by issuing the Unprotect command.
Block protection M58LT128HST, M58LT128HSB
50/110
9.4 Protection operations during Erase Suspend
Changes to b lo c k pr otection st atus can be p erformed during an er ase suspend by using the
standard protection command sequences to unprotect or protect a b lock. This is useful in
the case when another block needs to be updated while an erase operation is in progress.
To change block prote ction during an erase operation, first write the Erase Suspend
command, then check the Status Register un til it indicates that the erase operation has
been suspended . Next write the desired Protect command sequence to a bl ock and the
protection status will be changed. After completing any desired protect, read, or program
operations, resume the erase operation with the Erase Resume command.
If a block is protected during an erase suspend of the same block, the erase operation will
complete when the erase is resumed. Protection operations cannot be performed during a
program suspend.
M58LT128HST, M58LT128HSB Program and erase times and endurance cycles
51/110
10 Program and erase times and endurance cycles
The Program and Erase times and the number of Program/ Erase cycles per block are
shown in Table 16. Exact erase times may change depending on the memory array
condition. The best case is when all the bits in the block ar e at ‘0’ (pre-programmed). The
worst case is when all the bits in the block are at ‘1’ (not preprogrammed). Usually, the
system overhead is negligible with respect to the er ase time. In the M58LT128HST/B the
maximum number of Program/Erase cycles depends on the VPP volt age supply used.
Table 16. Program/Erase times and endurance cycles(1) (2)
Parameter Condition Min Typ Typical after
100kW/E
Cycles Max Unit
VPP = VDD
Erase
Parameter Block (16 Kword) 0.4 1 2.5 s
Main Block (64
Kword) Preprogrammed 1.2 3 4 s
Not Preprogrammed 1.5 4 s
Program(3)
Single word Word Program 12 180 µs
Buffer Program 12 180 µs
Buffer (32 words) (Buffer Program) 384 µs
Main Block (64 Kword) 768 ms
Suspend Latency Program 5 10 µs
Erase 5 20 µs
Program/Erase Cycles
(per Bloc k) Main Blocks 100,000 cycles
Parameter Bloc ks 100,000 cycles
Program and erase times and endurance cycles M58LT128HST, M58LT128HSB
52/110
VPP = VPPH
Erase Parameter Block (16 Kword) 0.4 2.5 s
Main Block (64 Kword) 1 4 s
Program(3)
Single word Word Program 10 170 µs
Buffer Enhanced
Factory Program(4) 2.5 µs
Buffer (32 words) Buffer Program 80 µs
Buffer Enhanced
Factory Program 80 µs
Main Block (64
Kwords)
Buffer Program 160 ms
Buffer Enhanced
Factory Program 160 ms
Bank (8 Mbits) Buffer Program 1.28 s
Buffer Enhanced
Factory Program 1.28 s
Program/Erase Cycles
(per Bloc k) Main Blocks 1000 cycles
Parameter Blocks 2500 cycles
Blank Check Main Blocks 16 ms
Parameter Blocks 4 ms
1. TA = –40 to 85°C; VDD = 1.7V to 2V; VDDQ = 2.7V to 3.6V.
2. Values are liable to change with the external system-level overhead (command seque nce and Status Register polling
execution).
3. Excludes the time needed to execute the command sequence.
4. This is an average value on the entire device.
Table 16. Program/Erase times and endurance cycles(1) (2) (continued)
Parameter Condition Min Typ Typical after
100kW/E
Cycles Max Unit
M58LT128HST, M58LT128HSB Maximum rating
53/110
11 Maximum rating
Stressing the device above the rating listed in the Absolute Maximum Ratings table may
cause permanent damage to the device. These are stress ratings only and operation of the
device at these or any other conditions above those indicated in the Operating sections of
this specification is not implied. Exposure to Absolute Maximum Rating conditions for
extended periods may affect device reliability. Refer also to the STMicroelectronics SURE
Program and other relevant quality documents.
Table 17. Absolute maximum rat ings
Symbol Parameter Value Unit
Min Max
TAAmbient operating temperature –40 85 °C
TBIAS Temperature under bias –40 85 °C
TSTG Storage temperature –65 125 °C
VIO Input or output vo ltage –0.5 3.8 V
VDD Supply voltage –0.2 2.5 V
VDDQ Input/output supply voltage –0.2 4.2 V
VPP Program voltage –0.2 10 V
IOOutput short circuit current 100 mA
tVPPH Time for VPP at VPPH 100 hours
DC and AC parameters M58LT128HST, M58LT128HSB
54/110
12 DC and AC parameters
This section summarizes the operating measurement conditions, and the DC and AC
characteristics of the device. The parameters in the DC and AC characteristics Tables that
follow, are derived from tests performed under the Measurement Co nditions summarized in
Table 18: Operating and ac measur ement conditions. Designers should check that the
operat ing conditions in their circuit match the operating conditions when relying on the
quoted parameters.
Figure 7. AC measurement I/O waveform
Table 18. Operating and ac measurement conditions
Parameter
M58LT128HST/B
Units85
Min Max
VDD supply voltage 1.7 2.0 V
VDDQ supply voltage 2.7 3.6 V
VPP supply voltage (factory environment) 8.5 9.5 V
VPP supply voltage (application environment) –0.4 VDDQ+0.4 V
Ambient operating temperature –40 85 °C
Load capacitance (CL)30pF
Input rise and fall times 5 ns
Input pulse voltages 0 to VDDQ V
Input and output timing ref. voltages VDDQ/2 V
AI06161
VDDQ
0V
VDDQ/2
M58LT128HST , M58LT128HSB DC and AC parameters
55/110
Figure 8. AC measurement load circuit
Table 19. Capacitance(1)
1. Sampled only, not 100% tested.
Symbol Parameter Test Condition Min Max Unit
CIN Input Capacitance VIN = 0V 6 8 pF
COUT Output Capacitance VOUT = 0V 8 12 pF
AI12842
VDDQ
CL
CL includes JIG capacitance
22k
DEVICE
UNDER
TEST
0.1µF
VDD
0.1µF
VDDQ
22k
DC and AC parameters M58LT128HST, M58LT128HSB
56/110
Table 20. DC characteristics - currents
Symbol Parameter Test Condition Typ Max Unit
ILI Input leakage current 0V VIN VDDQ ±1 µA
ILO Output leakage current 0V VOUT VDDQ ±1 µA
IDD1
Supply current
Asynchronous Read (f=5 MHz) E = VIL, G = VIH 14 16 mA
Supply current
Synchronous Read (f = 40 MHz)
4 word 13 17 mA
8 word 15 19 mA
16 word 17 21 mA
Continuous 21 26 mA
Supply current
Synchronous Read (f = 52 MHz)
4 word 16 19 mA
8 word 19 23 mA
16 word 22 26 mA
Continuous 23 28 mA
IDD2 Supply current (Reset) RP = VSS ± 0.2V 25 75 µA
IDD3 Supply current (Standby) E = VDDQ ± 0.2V
K=VSS 25 75 µA
IDD4 Supply current (Automatic
Standby) E = VIL, G = VIH 25 75 µA
IDD5(1)
1. Sampled only, not 100% tested.
Supply current (Program) VPP = VPPH 820mA
VPP = VDD 10 25 mA
Supply current (Erase) VPP = VPPH 820mA
VPP = VDD 10 25 mA
IDD6(1),(2)
2. VDD Dual Operation current is the sum of read and program or erase currents.
Supply current
(Dual operations)
Program/Erase in one Bank,
Asynchronous Read in another
Bank 24 41 mA
Program/Erase in one Bank,
Synchronous Read (Continuous
f=52 MHz) in another Bank 33 53 mA
IDD7(1) Supply current Program/ Erase
Suspended (Standby) E = VDDQ ± 0.2V
K=VSS 25 75 µA
IPP1(1)
VPP supply current (Program) VPP = VPPH 25mA
VPP = VDD 0.2 5 µA
VPP supply current (Erase) VPP = VPPH 25mA
VPP = VDD 0.2 5 µA
IPP2 VPP supply current (Read) VPP VDD 0.2 5 µA
IPP3(1) VPP supply current (Standby) VPP VDD 0.2 5 µA
M58LT128HST , M58LT128HSB DC and AC parameters
57/110
Table 21. DC characteristics - voltages
Symbol Parameter Test Condition Min Typ Max Unit
VIL Input Low Voltage 0 0.4 V
VIH Input High Vo ltage VDDQ –0.4 VDDQ + 0.4 V
VOL Output Low Voltage IOL = 100µA 0.1 V
VOH Output High Voltage IOH = –100µA VDDQ –0.1 V
VPP1 VPP Program Voltage-Logic Program, Erase 1.3 3 3.6 V
VPPH VPP Program Voltage Factory Prog ram, Erase 8.5 9.0 9.5 V
VPPLK Program or Erase Lockout 0.4 V
VLKO VDD Lock Voltage 1 V
DC and AC parameters M58LT128HST, M58LT128HSB
58/110
Figure 9. Asynchronous random access Read ac waveforms
AI09817
tAVAV
tELQX
tEHQX
tGLQV
tGLQX
tGHQX
DQ0-DQ15
E
G
tELQV
tEHQZ
tGHQZ
VALID
A0-A22 VALID VALID
L(2)
tELLH
tLLQV
tLLLH
tAVLH tLHAX tAXQX
WAIT(1)
tELTV
tEHTZ
Hi-Z
Hi-Z
tAVQV
tGLTV
tGHTZ
Notes: 1. Write Enable, W, is High, WAIT is active Low.
2. Latch Enable, L, can be kept Low (also at board level) when the Latch Enable function is not required or supported.
M58LT128HST , M58LT128HSB DC and AC parameters
59/110
Figure 10. Asynchronous Page Read ac waveforms
1. WAIT is active Low.
AI13570b
A2-A22
E
G
A0-A1 VALID ADD.
L
DQ0-DQ15
VALID ADD.VALID ADD.VALID ADDRESS
VALID ADDRESS
VALID
DATA
tLHAX
tAVLH
tLLQV
tAVQV1tGLQX
tLLLH
tELLH
WAIT
tAVAV
tELQV
tELQX
tELTV
tGLQV
(1)
Valid Address Latch Outputs
Enabled Valid Data Standby
Hi-Z
tGLTV
VALID
DATA VALID
DATA VALID
DATA
DC and AC parameters M58LT128HST, M58LT128HSB
60/110
Table 22. Asynchronous Read ac characteristics
Symbol Alt Parameter M58LT128HST/B Unit
85
Read Timings
tAVAV tRC Address Valid to Next Address Val id Min 85 ns
tAVQV tACC Address Valid to Output Valid (Random) Max 85 ns
tAVQV1 tPAGE Address Valid to Output Valid (Page) Max 25 ns
tAXQX(1)
1. Sampled only, not 100% tested.
tOH Address Transition to Output Transition Min 0 ns
tELTV Chip Enable Low to Wait Valid Max 17 ns
tELQV(2)
2. G may be delayed by up to tELQV - tGLQV after the falling edge of E without increasing tELQV.
tCE Chip Enable Low to Output Valid Max 85 ns
tELQX(1) tLZ Chip Enable Low to Output Transition Min 0 ns
tEHTZ Chip Enable High to Wait Hi-Z Max 17 ns
tEHQX(1) tOH Chip Enable High to Output Transition Min 0 ns
tEHQZ(1) tHZ Chip Enab le High to Output Hi-Z Max 17 ns
tGLQV(2) tOE Output Enable Low to Output Valid Max 25 ns
tGLQX(1) tOLZ Output Enable Low to Output Transition Min 0 ns
tGLTV Output Enable Low to Wait Valid Max 17 ns
tGHQX(1) tOH Output Enable High to Output Transition Min 0 ns
tGHQZ(1) tDF Output Enable High to Output Hi-Z Max 17 ns
tGHTZ Output Enable High to Wait Hi-Z Max 17 ns
Latch Timings
tAVLH tAVADVH Address Valid to Latch Enable High Min 10 ns
tELLH tELADVH Chip Enable Low to Latch Enable High Min 10 ns
tLHAX tADVHAX Latch Enable High to Address Transition Min 9 ns
tLLLH tADVLADVH Latch Enable Pulse Width Min 10 ns
tLLQV tADVLQV Latch Enable Low to Output Valid
(Random) Max 85 ns
M58LT128HST , M58LT128HSB DC and AC parameters
61/110
Figure 11. Synchronous Burst Read ac waveforms
AI09819b
DQ0-DQ15
E
G
A0-A22
L
WAIT
K
(4)
VALID VALID
VALID ADDRESS
tLLLH
tAVLH
tGLQX
tAVKH
tLLKH
tELKH tKHAX
tKHQXtKHQV
NOT VALID VALID
Note 1
Note 2 Note 2
tKHTX
tEHQX
tEHQZ
tGHQX
tGHQZ
Hi-Z
VALID
Note 2
tELTV tKHTV tEHTZ
Address
Latch X Latency Valid Data Flow Boundary
Crossing Valid
Data Standby
Note 1. The number of clock cycles to be inserted depends on the X latency set in the Burst Configuration Register.
2. The WAIT signal can be configured to be active during wait state or one cycle before. WAIT signal is active Low.
3. Address latched and data output on the rising clock edge.
4. Either the rising or the falling edge of the clock signal, K, can be configured as the active edge. Here, the active edge of K is the rising one.
tEHEL
Hi-Z
tGLTV
DC and AC parameters M58LT128HST, M58LT128HSB
62/110
Figure 12. Single Synchronous Read ac waveforms
1. The WAIT signal is configured to be active during wait state. WAIT signal is active Low.
2. Address latched and data output on the rising clock edge. Either the rising or the falling edge of the clock
signal, K, can be configured as the active edge. Here, the active edge is the rising one.
Ai12359
E
G
A0-A22
L
WAIT
(1,2)
K
(2)
VALID ADDRESS
tGLQV
tAVKH
tLLKH
tELKH
Hi-Z
tELQX
tKHQV
tGLQX
tKHTV
DQ0-DQ15 VALID
Hi-Z
tELQV
tGLTV
tGHTZ
M58LT128HST , M58LT128HSB DC and AC parameters
63/110
Figure 13. Synchronous Burst Read Suspend ac waveforms
AI12366b
DQ0-DQ15
E
G
A0-A22
L
WAIT(2)
K(4)
VALID VALID
VALID ADDRESS
tLLLH
tAVLH
tAVKH
tLLKH
tELKH tKHAX
VALID
VALID
Note 1
tEHQX
tEHQZ
tGHQX
Hi-Z tELTV
tKHQV
tEHTZ
Notes 1. The number of clock cycles to be inserted depends on the X latency set in the Configuration Register.
2. The WAIT signal is configured to be active during wait state. WAIT signal is active Low.
3. The CLOCK signal can be held high or low
4. Address latched and data output on the rising clock edge. Either the rising or the falling edge of the clock signal, K, can be configured as the active edge.
Here, the active edge is the rising one.
tGLQX
tEHEL
tGHQZ
tGLQV
Note 3
Hi-Z
tGLTV tGHTZ
DC and AC parameters M58LT128HST, M58LT128HSB
64/110
Figure 14. Clock input ac waveform
Table 23. Synchronous Read ac characteristics(1) (2)
1. Sampled only, not 100% tested.
2. For other timings please refer to Table 22: Asynchronous Read ac characteristics.
Symbol Alt Parameter M58LT128HST/B Unit
85
Synchronous Read Timings
tAVKH tAVCLKH Address Valid to Clock High Min 9 ns
tELKH tELCLKH Chip Enable Low to Clock High Min 9 ns
tELTV Chip Enable Low to Wait Valid Max 17 ns
tEHEL Chip Enable Pulse Width
(subsequent synchronous reads) Min 20 ns
tEHTZ Chip Enable High to Wait Hi-Z Max 17 ns
tKHAX tCLKHAX Clock High to Address Transition Min 10 ns
tKHQV
tKHTV tCLKHQV Clock High to Output Valid
Clock High to WAIT Valid Max 17 ns
tKHQX
tKHTX tCLKHQX Clock High to Output Transition
Clock High to WAIT Transition Min 3 ns
tLLKH tADVLCLKH Latch Enab le Low to Clock High Min 9 ns
Clock Specifications
tKHKH tCLK Clock Period (f=52 MHz) Min 19 ns
tKHKL
tKLKH
Clock High to Clock Low
Clock Low to Clock High Min 6 ns
tf
trClock Fall or Rise Time Max 2 ns
AI06981
tKHKH
tf tr
tKHKL
tKLKH
M58LT128HST , M58LT128HSB DC and AC parameters
65/110
Figure 15. Write ac waveforms, Write Enable controlled
E
G
W
DQ0-DQ15 COMMAND CMD or DATA STATUS REGISTER
VPP
VALID ADDRESSA0-A22
tAVAV
tQVVPL
tAVWH tWHAX
PROGRAM OR ERASE
tELWL tWHEH
tWHDX
tDVWH
tWLWH
tWHWL
tVPHWH
SET-UP COMMAND CONFIRM COMMAND
OR DATA INPUT
STATUS REGISTER
READ
1st POLLING
tELQV
Ai12889
tWHGL
tWHEL
BANK ADDRESS VALID ADDRESS
L
tAVLH
tLLLH
tELLH
tLHAX
tGHWL
tWHVPL
tELKV
K
tWHLL
tWHAV
DC and AC parameters M58LT128HST, M58LT128HSB
66/110
Table 24. Write ac characteristics, Write Enable cont rolled(1)
1. Sampled only, not 100% tested.
Symbol Alt Parameter M58LT128HST/B Unit
85
Write Enable Controlled Timings
tAVAV tWC Address Valid to Next Address Valid Min 85 ns
tAVLH Address Valid to Latch Enable High Min 10 ns
tAVWH(2) Ad dress Valid to Write Enable High Min 50 ns
tDVWH tDS Data Valid to Write Enable High Min 50 ns
tELLH Chip Enable Low to Latch Enable High Min 10 ns
tELWL tCS Chip Enable Low to Write Enable Low Min 0 ns
tELQV Chip Enable Low to Output Valid Min 85 ns
tELKV Chip Enable Low to Clock Valid Min 9 ns
tGHWL Output Enable High to Write Enable Low Min 17 ns
tLHAX Latch Enable High to Address Transition Min 9 ns
tLLLH Latch Enable Pulse Width Min 10 ns
tWHAV(2)
2. Meaningful only if L is always kept low.
Write Enable High to Address Valid Mi n 0 ns
tWHAX(2) tAH Write Enable High to Address Transition Min 0 ns
tWHDX tDH Write Enable High to Input Transition Min 0 ns
tWHEH tCH Write Enable High to Chip Enable High Min 0 ns
tWHEL(3)
3. tWHEL and tWHLL have this value when reading in the targeted bank or when reading following a Set
Configuration Register command. System designers should take this into account and may insert a
software No-Op instruction to delay the first read in the same bank after issuing any command and to delay
the first read to any address after issuing a Set Configuration Register command. If the first read after the
command is a Read Array operation in a different bank and no changes to the Configuration Register have
been issued, tWHEL and tWHLL are 0ns.
Write Enable High to Chip Enable Low Min 25 ns
tWHGL Write Enable High to Output Enable Low Min 0 ns
tWHLL(3) Write Enable High to Latch Enable Low Min 25 ns
tWHWL tWPH Write Enable High to Write Enable Low Mi n 25 ns
tWLWH tWP Write Enable Low to Write Enable High Min 50 ns
Protection Timings
tQVVPL Output (Status Register) Valid to VPP Low Min 0 ns
tVPHWH tVPS VPP High to Write Enable High Min 200 ns
tWHVPL Write Enable High to VPP Low Min 200 ns
M58LT128HST , M58LT128HSB DC and AC parameters
67/110
Figure 16. Write ac waveforms, Chip Enable controlled
W
G
E
DQ0-DQ15 COMMAND CMD or DATA STATUS REGISTER
VPP
VALID ADDRESSA0-A22
tAVAV
tQVVPL
tAVEH tEHAX
PROGRAM OR ERASE
tWLEL
tEHWH
tEHDX
tDVEH
tELEH
tEHEL
tVPHEH
SET-UP COMMAND CONFIRM COMMAND
OR DATA INPUT STATUS REGISTER
READ
1st POLLING
tELQV
Ai12890
tEHGL
tWHEL
BANK ADDRESS VALID ADDRESS
L
tAVLH
tLLLH
tLHAX
tGHEL
tEHVPL
tELKV
K
tELLH
DC and AC parameters M58LT128HST, M58LT128HSB
68/110
Table 25. Write ac Characteristics, Chip Enable Controlled(1)
1. Sampled only, not 100% tested.
Symbol Alt Parameter M58LT128HST/B Unit
85
Chip Enable Controlled Timings
tAVAV tWC Address Valid to Next Address Valid Min 85 ns
tAVEH Address Valid to Chip Enable High Min 50 ns
tAVLH Address Valid to Latch Enable High Min 10 ns
tDVEH tDS Data Valid to Chip Enable High Min 50 ns
tEHAX tAH Chip Enable High to Address Transition Min 0 ns
tEHDX tDH Chip Enable High to Input Transition Min 0 ns
tEHEL tCPH Chip Enable High to Chip Enable Low Min 25 ns
tEHGL Chip Enable High to Output Enable Low Min 0 ns
tEHWH tCH Chip Enable High to Write Enable High Min 0 ns
tELKV Chip Enable Low to Clock Valid Min 9 ns
tELEH tCP Chip Enable Low to Chip Enable High Min 50 ns
tELLH Chip Enable Low to Latch Enable High Min 10 ns
tELQV Chip Enable Low to Output Valid Min 85 ns
tGHEL Output Enable High to Chip Enable Low Min 17 ns
tLHAX Latch Enable High to Address Transition Min 9 ns
tLLLH Latch Enable Pulse Width Min 10 ns
tWHEL(2)
2. tWHEL has this value when reading in the targeted bank or when reading following a Set Configuration
Register command. System designers should take this into account and may insert a software No-Op
instruction to delay the first read in the same bank after issuing any command and to delay the first read to
any address after issuing a Set Configuration Register command. If the first read after the command is a
Read Array operation in a different bank and no changes to the Configuration Register have been issued,
tWHEL is 0ns.
Write Enable High to Chip Enable Low Min 25 ns
tWLEL tCS Write Enable Low to Chip Enable Low Min 0 ns
Protection Timings
tEHVPL Chip Enable High to VPP Low Min 20 0 ns
tQVVPL Output (Status Register) Valid to VPP Low Min 0 ns
tVPHEH tVPS VPP High to Chip Enable High Min 200 ns
M58LT128HST , M58LT128HSB DC and AC parameters
69/110
Figure 17. Reset and Power-up ac waveforms
AI06976
W,
RP
E, G,
VDD, VDDQ
tVDHPH tPLPH
Power-Up Reset
tPLWL
tPLEL
tPLGL
tPLLL
LtPHWL
tPHEL
tPHGL
tPHLL
Table 26. Reset and Power -up ac charact eristics
Symbol Parameter Test condition 85 Unit
tPLWL
tPLEL
tPLGL
tPLLL
Reset Low to
Write Enable Low,
Chip Enable Low,
Output Enable Low,
Latch Enable Low
During Program Min 25 µs
During Erase Min 25 µs
Read Min 80 ns
Other conditions Min 20 µs
tPHWL
tPHEL
tPHGL
tPHLL
Reset High to
Write Enable Low
Chip Enable Low
Output Enable Low
Latch Enable Low
Min 30 ns
tPLPH(1),(2) RP Pulse Width Min 50 ns
tVDHPH(3) Supply Voltages High to Reset
High Min 150 µs
1. The device Reset is possible but not guaran teed if tPLPH < 50ns.
2. Sampled only, not 100% tested.
3. It is important to assert RP in order to allow proper CPU initialization during Power-Up or Reset.
Package mechanical M58LT128HST, M58LT128HSB
70/110
13 Package mechanical
In order to meet environmental requirements, ST offers these devices in ECOPACK®
packages. These packages have a Lead-free second-level interconnect. The category of
Second-Level Interconnect is marked on the package and on the inner box label, in
compliance with JEDEC Standard JESD97.
The maximum r atings related to soldering conditions ar e also marked on the inner bo x label.
ECOPACK is an ST trademark. ECOPACK specifications are available at: www.st.com.
Figure 18. TBGA64 10 × 13 mm - 8 × 8 active ball array, 1 mm pitch, bottom view
package outline
1. Drawing is not to scale.
E1E
D1
D
eb
SD
SE
A2
A1
A
BGA-Z23
ddd
FD
FE
BALL "A1"
M58LT128HST , M58LT128HSB Package mechanical
71/110
Table 27. TBGA64 10 × 13 mm - 8 × 8 active ball array, 1 mm pitch, package
mechanical data
Symbol millimeters inches
Typ Min Max Typ Min Max
A 1.200 0.0472
A1 0.300 0.200 0.350 0.0118 0.0079 0.0138
A2 0.800 0.0315
b 0.350 0.500 0.0138 0.0197
D 10.000 9.900 10.100 0.3937 0.3898 0.3976
D1 7.000 0.2756
ddd 0.100 0.0039
e 1.000 0.0394
E 13.000 12.900 13.100 0.5118 0.5079 0.5157
E1 7.000 0.2756
FD 1.500 0.0591
FE 3.000 0.1181
SD 0.500 0.0197
SE 0.500 0.0197
Part numbering M58LT128HST, M58LT128HSB
72/110
14 Part numbering
Devices are shipped from the factory with the memory content bits erased to ’1’.
F or a list of a vailable option s (Speed, Package , etc.) or for further inf ormation on an y aspect
of this device, please contact the ST Sales Office nearest to you.
Table 28. Ordering information scheme
Example: M58LT128HST 8 ZA 6 E
Device type
M58
Architecture
L = Multilevel, Multiple Bank, Burst Mode
Operatin g voltage
T = VDD = 1.7 V to 2.0 V, VDDQ = 2.7 V to 3.6 V
Density
128 = 128 Mbit (x16)
Technology
H = 90nm technology
Security
S = Secure
Parameter location
T = Top Boot
B = Bottom Boot
Speed
8 = 85 ns
Package
ZA = TBGA64, 10 × 13 mm, 1 mm pitch
Temperature range
6 = –40 to 85°C
Pack in g op tion
E = ECOPACK® Package, Standard Packing
F = ECOPACK® Package, Tape & Reel Packing
M58LT128HST, M58LT128HSB Block address t ables
73/110
Appendix A Block address tables
Table 29. Top boot block addresses, M58LT128HST
Bank(1) # Size (Kword) Address Range
Parameter Bank
0 16 7FC000-7FFFFF
1 16 7F8000-7FBFFF
2 16 7F4000-7F7FFF
3 16 7F0000-7F3FFF
4 64 7E0000-7EFFFF
5 64 7D0000-7DFFFF
6 64 7C0000-7CFFFF
7 64 7B0000-7BFFFF
8 64 7A0000-7AFFFF
9 64 790000-79FFFF
10 64 780000-78FFFF
Bank 1
11 64 770000-77FFFF
12 64 760000-76FFFF
13 64 750000-75FFFF
14 64 740000-74FFFF
15 64 730000-73FFFF
16 64 720000-72FFFF
17 64 710000-71FFFF
18 64 700000-70FFFF
Bank 2
19 64 6F0000-6FFFFF
20 64 6E0000-6EFFFF
21 64 6D0000-6DFFFF
22 64 6C0000-6CFFFF
23 64 6B0000-6BFFFF
24 64 6A0000-6AFFFF
25 64 690000-69FFFF
26 64 680000-68FFFF
Bank 3
27 64 670000-67FFFF
28 64 660000-66FFFF
29 64 650000-65FFFF
30 64 640000-64FFFF
31 64 630000-63FFFF
32 64 620000-62FFFF
33 64 610000-61FFFF
34 64 600000-60FFFF
Block address tables M58LT128HST, M58LT128HSB
74/110
Bank 4
35 64 5F0000-5FFFFF
36 64 5E0000-5EFFFF
37 64 5D0000-5DFFFF
38 64 5C0000-5CFFFF
39 64 5B0000-5BFFFF
40 64 5A0000-5AFFFF
41 64 590000-59FFFF
42 64 580000-58FFFF
Bank 5
43 64 570000-57FFFF
44 64 560000-56FFFF
45 64 550000-55FFFF
46 64 540000-54FFFF
47 64 530000-53FFFF
48 64 520000-52FFFF
49 64 510000-51FFFF
50 64 500000-50FFFF
Bank 6
51 64 4F0000-4FFFFF
52 64 4E0000-4EFFFF
53 64 4D0000-4DFFFF
54 64 4C0000-4CFFFF
55 64 4B0000-4BFFFF
56 64 4A0000-4AFFFF
57 64 490000-49FFFF
58 64 480000-48FFFF
Bank 7
59 64 470000-47FFFF
60 64 460000-46FFFF
61 64 450000-45FFFF
62 64 440000-44FFFF
63 64 430000-43FFFF
64 64 420000-42FFFF
65 64 410000-41FFFF
66 64 400000-40FFFF
Table 29. Top boot block addresses, M58LT128HST (continued)
Bank(1) # Size (Kword) Address Range
M58LT128HST, M58LT128HSB Block address t ables
75/110
Bank 8
67 64 3F0000-3FFFFF
68 64 3E0000-3EFFFF
69 64 3D0000-3DFFFF
70 64 3C0000-3CFFFF
71 64 3B0000-3BFFFF
72 64 3A0000-3AFFFF
73 64 390000-39FFFF
74 64 380000-38FFFF
Bank 9
75 64 370000-37FFFF
76 64 360000-36FFFF
77 64 350000-35FFFF
78 64 340000-34FFFF
79 64 330000-33FFFF
80 64 320000-32FFFF
81 64 310000-31FFFF
82 64 300000-30FFFF
Bank 10
83 64 2F0000-2FFFFF
84 64 2E0000-2EFFFF
85 64 2D0000-2DFFFF
86 64 2C0000-2CFFFF
87 64 2B0000-2BFFFF
88 64 2A0000-2AFFFF
89 64 290000-29FFFF
90 64 280000-28FFFF
Bank 11
91 64 270000-27FFFF
92 64 260000-26FFFF
93 64 250000-25FFFF
94 64 240000-24FFFF
95 64 230000-23FFFF
96 64 220000-22FFFF
97 64 210000-21FFFF
98 64 200000-20FFFF
Table 29. Top boot block addresses, M58LT128HST (continued)
Bank(1) # Size (Kword) Address Range
Block address tables M58LT128HST, M58LT128HSB
76/110
Bank 12
99 64 1F0000-1FFFFF
100 64 1E0000-1EFFFF
101 64 1D0000-1DFFFF
102 64 1C0000-1CFFFF
103 64 1B0000-1BFFFF
104 64 1A0000-1AFFFF
105 64 190000-19FFFF
106 64 180000-18FFFF
Bank 13
107 64 170000-17FFFF
108 64 160000-16FFFF
109 64 150000-15FFFF
110 64 140000-14FFFF
111 64 130000-13FFFF
112 64 120000-12FFFF
113 64 110000-11FFFF
114 64 100000-10FFFF
Bank 14
115 64 0F0000-0FFFFF
116 64 0E0000-0EFFFF
117 64 0D0000-0DFFFF
118 64 0C0000-0CFFFF
119 64 0B0000-0BFFFF
120 64 0A0000-0AFFFF
121 64 090000-09FFFF
122 64 080000-08FFFF
Bank 15
123 64 070000-07FFFF
124 64 060000-06FFFF
125 64 050000-05FFFF
126 64 040000-04FFFF
127 64 030000-03FFFF
128 64 020000-02FFFF
129 64 010000-01FFFF
130 64 000000-00FFFF
1. There are two Bank Regions: Bank Region 1 contains all the banks that are made up of main blocks only;
Bank Region 2 contains the banks that are made up of the parameter and main blocks (Parameter Bank).
Table 29. Top boot block addresses, M58LT128HST (continued)
Bank(1) # Size (Kword) Address Range
M58LT128HST, M58LT128HSB Block address t ables
77/110
Table 30. Bottom boot block addresses, M58LT128HSB
Bank(1) # Size (Kword) Address Range
Bank 15
130 64 7F0000-7FFFFF
129 64 7E0000-7EFFFF
128 64 7D0000-7DFFFF
127 64 7C0000-7CFFFF
126 64 7B0000-7BFFFF
125 64 7A0000-7AFFFF
124 64 790000-79FFFF
123 64 780000-78FFFF
Bank 14
122 64 770000-77FFFF
121 64 760000-76FFFF
120 64 750000-75FFFF
119 64 740000-74FFFF
118 64 730000-73FFFF
117 64 720000-72FFFF
116 64 710000-71FFFF
115 64 700000-70FFFF
Bank 13
114 64 6F0000-6FFFFF
113 64 6E0000-6EFFFF
112 64 6D0000-6DFFFF
111 64 6C0000-6CFFFF
110 64 6B0000-6BFFFF
109 64 6A0000-6AFFFF
108 64 690000-69FFFF
107 64 680000-68FFFF
Bank 12
106 64 670000-67FFFF
105 64 660000-66FFFF
104 64 650000-65FFFF
103 64 640000-64FFFF
102 64 630000-63FFFF
101 64 620000-62FFFF
100 64 610000-61FFFF
99 64 600000-60FFFF
Block address tables M58LT128HST, M58LT128HSB
78/110
Bank 11
98 64 5F0000-5FFFFF
97 64 5E0000-5EFFFF
96 64 5D0000-5DFFFF
95 64 5C0000-5CFFFF
94 64 5B0000-5BFFFF
93 64 5A0000-5AFFFF
92 64 590000-59FFFF
91 64 580000-58FFFF
Bank 10
90 64 570000-57FFFF
89 64 560000-56FFFF
88 64 550000-55FFFF
87 64 540000-54FFFF
86 64 530000-53FFFF
85 64 520000-52FFFF
84 64 510000-51FFFF
83 64 500000-50FFFF
Bank 9
82 64 4F0000-4FFFFF
81 64 4E0000-4EFFFF
80 64 4D0000-4DFFFF
79 64 4C0000-4CFFFF
78 64 4B0000-4BFFFF
77 64 4A0000-4AFFFF
76 64 490000-49FFFF
75 64 480000-48FFFF
Bank 8
74 64 470000-47FFFF
73 64 460000-46FFFF
72 64 450000-45FFFF
71 64 440000-44FFFF
70 64 430000-43FFFF
69 64 420000-42FFFF
68 64 410000-41FFFF
67 64 400000-40FFFF
Table 30. Bottom boot block addresses, M58LT128HSB (continued)
Bank(1) # Size (Kword) Address Range
M58LT128HST, M58LT128HSB Block address t ables
79/110
Bank 7
66 64 3F0000-3FFFFF
65 64 3E0000-3EFFFF
64 64 3D0000-3DFFFF
63 64 3C0000-3CFFFF
62 64 3B0000-3BFFFF
61 64 3A0000-3AFFFF
60 64 390000-39FFFF
59 64 380000-38FFFF
Bank 6
58 64 370000-37FFFF
57 64 360000-36FFFF
56 64 350000-35FFFF
55 64 340000-34FFFF
54 64 330000-33FFFF
53 64 320000-32FFFF
52 64 310000-31FFFF
51 64 300000-30FFFF
Bank 5
50 64 2F0000-2FFFFF
49 64 2E0000-2EFFFF
48 64 2D0000-2DFFFF
47 64 2C0000-2CFFFF
46 64 2B0000-2BFFFF
45 64 2A0000-2AFFFF
44 64 290000-29FFFF
43 64 280000-28FFFF
Bank 4
42 64 270000-27FFFF
41 64 260000-26FFFF
40 64 250000-25FFFF
39 64 240000-24FFFF
38 64 230000-23FFFF
37 64 220000-22FFFF
36 64 210000-21FFFF
35 64 200000-20FFFF
Table 30. Bottom boot block addresses, M58LT128HSB (continued)
Bank(1) # Size (Kword) Address Range
Block address tables M58LT128HST, M58LT128HSB
80/110
Bank 3
34 64 1F0000-1FFFFF
33 64 1E0000-1EFFFF
32 64 1D0000-1DFFFF
31 64 1C0000-1CFFFF
30 64 1B0000-1BFFFF
29 64 1A0000-1AFFFF
28 64 190000-19FFFF
27 64 180000-18FFFF
Bank 2
26 64 170000-17FFFF
25 64 160000-16FFFF
24 64 150000-15FFFF
23 64 140000-14FFFF
22 64 130000-13FFFF
21 64 120000-12FFFF
20 64 110000-11FFFF
19 64 1F0000-1FFFFF
Bank 1
18 64 0F0000-0FFFFF
17 64 0E0000-0EFFFF
16 64 0D0000-0DFFFF
15 64 0C0000-0CFFFF
14 64 0B0000-0BFFFF
13 64 0A0000-0AFFFF
12 64 090000-09FFFF
11 64 080000-08FFFF
Parameter Bank
10 64 070000-07FFFF
9 64 060000-06FFFF
8 64 050000-05FFFF
7 64 040000-04FFFF
6 64 030000-03FFFF
5 64 020000-02FFFF
4 64 010000-01FFFF
3 16 00C000-00FFFF
2 16 008000-00BFFF
1 16 004000-007FFF
0 16 000000-003FFF
1. There are two Bank Regions: Bank Region 2 contains all the banks that are made up of main blocks only;
Bank Region 1 contains the banks that are made up of the parameter and main blocks (Parameter Bank).
Table 30. Bottom boot block addresses, M58LT128HSB (continued)
Bank(1) # Size (Kword) Address Range
M58LT128HST, M58LT128HSB Common Flash Interface
81/110
Appendix B Common Flash Interface
The Common F lash Interf ace is a JEDEC appro ve d, standardiz ed data structure tha t can be
read from the Flash memory device. It allows a system software to query the device to
determine various electrical and timing parameters, density information and functions
supported by the memory. The system can interface easily with the device, enabling the
software to upgrade itself when necessary.
When the Read CFI Qu ery Command is issued the device enters CFI Query mode and the
data structure is read from the memory. Tables 31, 32, 33, 34, 35, 36, 37, 38, 39 and 40
show the addresses use d to retrieve the data . Th e Qu e ry data is always presented on the
lowest order data outputs (DQ0-DQ7), the other outputs ( DQ8-DQ15) are set to 0.
The CFI data structure also cont ains a security area wher e a 64 bit uniq ue security numbe r
is written (see Figure 4: Protection Register memory map). This area can be accessed on ly
in Read mode by the final user. It is impossible to change the security number after it has
been written by ST. Issue a Read Array command to return to Read mode.
1. The Flash memory display the CFI data structure when CF I Query command is issued. In this table are
listed the main sub-sections detailed in Tables 32, 33, 34 and 35. Query data is always presented on the
lowest order data outputs.
Table 31. Query structure overview
Offset Sub-section Name Description
000h Reserved Reserv ed for algorithm-specific inf ormation
010h CFI Query Identification String Command set ID and algorithm data offset
01Bh System Interface Information Device timing & voltage information
027h Device Geometry Definition Flash device layout
PPrimary Algorithm-specific Extended
Query tab le Additional information specific to the Primary
Algorithm (optional)
AAlter nate Algorithm-specific Extended
Query tab le Additional information specific to the Alternate
Algorithm (optional)
080h Secur ity Code Area Lock Protection Register
Unique device Number and
User Programmable OT P
Common Flash Interface M58LT128HST, M58 LT128HSB
82/110
Table 32. CFI query identification string
Offset Sub-section Name Description Value
000h 0020h Manufacturer Code ST
001h 88D6h
88D7h Device Code M58LT128HST
M58LT128HSB Top
Bottom
002h-00Fh Reserved Reserved
010h 0051h
Query Unique ASCII String "QRY"
"Q"
011h 0052h "R"
012h 0059h "Y"
013h 0001h Primary Algo rithm Command Set and Control
Interface ID code 16 bit ID code defining a specific
algorithm
014h 0000h
015h offset = P = 000Ah Address for Primary Algorithm extended Query table
(see Table 35)p = 10Ah
016h 0001h
017h 0000h Alternate Vendor Command Set and Control
Interface ID Code second vendor - specified
algorithm supported NA
018h 0000h
019h valu e = A = 0000h Address for Alternate Algorithm extended Query
table NA
01Ah 0000h
M58LT128HST, M58LT128HSB Common Flash Interface
83/110
Table 33. CFI query system interface information
Offset Data Description Value
01Bh 0017h VDD Logic Supply Minimum Program/Erase or Write voltage
bit 7 to 4 BCD value in volts
bit 3 to 0 BCD value in 100 millivolts 1.7V
01Ch 0020h VDD Logic Supply Maximum Program/Erase or Write voltage
bit 7 to 4 BCD value in volts
bit 3 to 0 BCD value in 100 millivolts 2V
01Dh 0085h VPP [Programming] Supply Minimum Program/Erase voltage
bit 7 to 4 HEX value in volts
bit 3 to 0 BCD value in 100 millivolts 8.5V
01Eh 0095h VPP [Programming] Suppl y Maximum Program/Erase voltage
bit 7 to 4 HEX value in volts
bit 3 to 0 BCD value in 100 millivolts 9.5V
01Fh 0004h Typical time-out per single byte/word program = 2n µs 16µs
020h 0009h Typical time-out for Buffer Program = 2n µs 512µs
021h 000Ah Typical time-out per individual block erase = 2n ms 1s
022h 0000h Typical time-out for full chip erase = 2n ms NA
023h 0004h Maximum time-out for word program = 2n times typical 256µs
024h 0004h Maximum time-out for Buffer Program = 2n times typical 8192µs
025h 0002h Maximum time-out per individual block erase = 2n times typical 4s
026h 0000h Maximum time-out for chip erase = 2n times typical NA
Common Flash Interface M58LT128HST, M58 LT128HSB
84/110
Table 34. Devi ce geometry definition
Offset Data Description Value
027h 0018h Device Size = 2n in number of b ytes 16 Mbytes
028h
029h 0001h
0000h Flash Device Interface Code description x16
Async.
02Ah
02Bh 0006h
0000h Maximum number of bytes in m ulti-byte program or page = 2n 64 bytes
02Ch 0002h Number of identical sized erase block regions within the
device
bit 7 to 0 = x = number of Erase Block Regions 2
TOP DEVICES
02Dh
02Eh 007Eh
0000h Erase Block Region 1 Information
Number of identical-size erase blocks = 00 7Eh+1 127
02Fh
030h 0000h
0002h Erase Block Region 1 Information
Block size in Region 1 = 0200h * 256 byte 128 Kbyte
031h
032h 0003h
0000h Erase Block Region 2 Information
Number of identical-size erase blocks = 00 03h+1 4
033h
034h 0080h
0000h Erase Block Region 2 Information
Block size in Region 2 = 0080h * 256 byte 32 Kbyte
035h
038h Reserved Reserved for future erase block region information NA
BOTTOM DEVICES
02Dh
02Eh 0003h
0000h Erase Block Region 1 Information
Number of identical-size erase block = 00 03h+1 4
02Fh
030h 0080h
0000h Erase Block Region 1 Information
Block size in Region 1 = 0080h * 256 bytes 32 Kbytes
031h
032h 007Eh
0000h Erase Block Region 2 Information
Number of identical-size erase block = 00 7Eh+1 127
033h
034h 0000h
0002h Erase Block Region 2 Information
Block size in Region 2 = 0200h * 256 bytes 128 Kbytes
035h
038h Reserved Reserved for future erase block region information NA
M58LT128HST, M58LT128HSB Common Flash Interface
85/110
Table 35. Primary algorithm-specific extended query table
Offset Data Description Value
(P)h = 10Ah 0050h Primary Algorithm extended Query table unique ASCII string
“PRI”
"P"
0052h "R"
0049h "I"
(P+3)h =10Dh 0031h Major version number, ASCII "1"
(P+4)h = 10Eh 0033h Minor version number, ASCII "3"
(P+5)h = 10Fh 00E6h Extended Query table contents for Primary Algorithm. Address
(P+5)h contains less significant byte.
bit 0 Chip Erase supported(1 = Yes, 0 = No)
bit 1 Erase Suspend supported(1 = Yes, 0 = No)
bit 2 Program Suspend supported(1 = Yes, 0 = No)
bit 3 Legacy Protect/Unprote c t supported(1 = Yes, 0 = No)
bit 4 Queued Erase supported(1 = Yes, 0 = No)
bit 5 Instant individual bloc k protection supported(1 = Yes, 0 =
No)
bit 6 Protection bits supported(1 = Yes, 0 = No)
bit 7 Page mode read supported(1 = Yes, 0 = No)
bit 8 Synchronous read supported(1 = Yes, 0 = No)
bit 9 Simultaneous operation supported(1 = Yes, 0 = No)
bit 10 to 31 Reserv ed; undefined bits are ‘0’. If bit 31 is ’1’ then
another 31 bit field of optional features f ollows at the end of the
bit-30 field.
No
Yes
Yes
No
No
Yes
Yes
Yes
Yes
Yes
0003h
(P+7)h = 111h 0000h
(P+8)h = 112h 0000h
(P+9)h = 113h 0001h
Supported Functions after Suspend
Read Array, Read Status Register and CFI Query
bit 0 Program supported after Erase Suspend (1 = Yes, 0 = No)
bit 7 to 1 Reserved; undefined bits are ‘0’ Yes
(P+A)h = 114h 0003h Block Protect Status
Defines which bits in the Block Status Register section of the
Query are implemented.
bit 0 Block protect Status Register Protect/Unprotect
bit active (1 = Yes, 0 = No)
bit 1 Block Protection Status Register Loc k-Down bit activ e (1
= Yes, 0 = No)
bit 15 to 2 Reser ved for future use; undefined bits are ‘0’
Yes
No
(P+B)h = 115h 0000h
(P+C)h = 116h 0018h
VDD Logic Supply Optimum Program/Erase voltage (highest
performance)
bit 7 to 4 HEX value in volts
bit 3 to 0 BCD value in 100 mV
1.8V
(P+D)h = 117h 0090h
VPP Supply Optimum Program/Erase voltage
bit 7 to 4 HEX value in volts
bit 3 to 0 BCD value in 100 mV
9V
Common Flash Interface M58LT128HST, M58 LT128HSB
86/110
Table 36. Protection Register information
Offset Data Description Value
(P+E)h = 118h 0002h Number of Protection Register fields in JEDEC ID space.
0000h indicates that 256 fields are a vailable. 2
(P+F)h = 119h 0080h Protection Field 1: Protection Description
Bits 0-7 Lower by te of Protection Register address
Bits 8-15 Upper byte of Protection Register address
Bits 16-23 2n bytes in factory pre-programmed region
Bits 24-31 2n bytes in user programmable region
80h
(P+10)h = 11Ah 0000h 00h
(P+ 11)h = 11Bh 0003h 8 bytes
(P+12)h = 11Ch 0003h 8 bytes
(P+13)h = 11Dh 0089h Protection Register 2: Protection Description
Bits 0-31 Protection Register address
Bits 32-39 n number of factory programmed regions (lower
byte)
Bits 40-47 n number of factory programmed regions (upper
byte)
Bits 48-55 2n bytes in factory programmable region
Bits 56-63 n number of user programmable regions (lower
byte)
Bits 64-71 n number of user programmable regions (upper
byte)
Bits 72-79 2n bytes in user programmable region
89h
(P+14)h = 11Eh 0000h 00h
(P+15)h = 11Fh 0000h 00h
(P+16)h = 120h 0 000h 00h
(P+17)h = 121h 0 000h 0
(P+18)h = 122h 0 000h 0
(P+19)h = 123h 0 000h 0
(P+1A)h = 124h 0010h 16
(P+1B)h = 125h 0000h 0
(P+1C)h = 126h 0004h 16
Table 37. Burst Read information
Offset Data Description Value
(P+1D)h = 127h 0003h
Page-mode read capability
bits 0-7 n’ such that 2n HEX value represents the number of
read-page bytes. See offset 0028h for de vice word width to
deter mine page-mode data output width.
8 bytes
(P+1E)h = 128h 0004h Number of synchronous mode read configuration fields that
f ollow. 4
(P+1F)h = 129h 0001h
Synchronous mode read capability configuration 1
bit 3-7 Reserved
bit 0-2 n’ such that 2n+1 HEX v alue represents the maximum
number of continuous synchronous reads when the device is
configured for its maximum word width. A value of 07h
indicates that the device is capable of continuous linear
bursts that will output data until the internal burst counter
reaches the end of the device’s burstable address space.
This field’s 3-bit value can be written dire ctl y t o the re ad
Configuration Register bit 0-2 if the device is configured for
its maximum word width. See offset 0028h for word width to
deter mine the burst data output width.
4
(P+20)h = 12Ah 0002h Synchronous mode read capability configuration 2 8
(P-21)h = 12Bh
(P+22)h = 12Ch 0003h
0007h Synchronous mode read capability configuration 3 16
Synchronous mode read capability co nfiguration 4 Cont.
M58LT128HST, M58LT128HSB Common Flash Interface
87/110
Table 38. Bank and Erase Block region information(1) (2)
1. The variable P is a pointer which is defined at CFI offset 015h.
2. Bank Regions. There are two Bank Regions, see Table 29 and Table 30.
Flash memory (top) Flash memory (bottom) Description
Offset Data Offset Data
(P+23)h = 12Dh 02h (P+23)h = 12Dh 02h Number of Bank Regions within the device
Table 39. Bank and Erase Block region 1 information
M58LT128HST (top) M58LT128HSB
(bottom) Description
Offset Data Offset Data
(P+24)h = 12Eh 0Fh (P+24)h = 12Eh 01h Number of identical banks within Bank Region 1
(P+25)h = 12Fh 00h (P+25)h = 12Fh 00h
(P+26)h = 130h 11h (P+26)h = 130h 11h
Number of program or erase operations allowed
in Bank Region 1:
Bits 0-3: Number of simultaneous program
operations
Bits 4-7: Number of simultaneous erase
operations
(P+27)h = 131h 00h (P+27)h = 131h 00h
Number of program or erase operations allowed
in other banks while a bank in same region is
programming
Bits 0-3: Number of simultaneous program
operations
Bits 4-7: Number of simultaneous erase
operations
(P+28)h = 132h 00h (P+28)h = 132h 00h
Number of program or erase operations allowed
in other banks while a bank in this region is
erasing
Bits 0-3: Number of simultaneous program
operations
Bits 4-7: Number of simultaneous erase
operations
(P+29)h = 133h 01h (P+29)h = 133h 02h
Types of erase block regions in Bank Region 1
n = number of erase block regions with
contiguous same-size erase blocks .
Symmetrically blocked banks have one blocking
region(2).
(P+2A)h = 134h 07h (P+2A)h = 134h 03h Bank Region 1 Erase Block Type 1 Information
Bits 0-15: n+1 = number of identical-sized erase
blocks
Bits 16-31: n×256 = number of bytes in erase
block region
(P+2B)h = 135h 00h (P+2B)h = 135h 00h
(P+2C)h = 136h 00h (P+2C)h = 136h 80h
(P+2D)h = 137h 02h (P+2D)h = 137h 00h
(P+2E)h = 138h 64h (P+2E)h = 138h 64h Ba nk Region 1 (Erase Block Type 1)
Minimum block erase cycles × 1000
(P+2F)h = 139h 00h (P+2F)h = 139h 00h
Common Flash Interface M58LT128HST, M58 LT128HSB
88/110
1. The variable P is a pointer which is defined at CFI offset 015h.
2. Bank Regions. There are two Bank Regions, see Table 29 to Table 30.
(P+30)h = 13Ah 01h (P+30)h = 13Ah 01h
Bank Region 1 (Erase Block Type 1): BIts per
cell, internal ECC
Bits 0-3: bits per cell in erase region
Bit 4: reserved for “internal ECC used”
BIts 5-7: reserved
(P+31)h = 13Bh 03h (P+31)h = 13Bh 03h
Bank Region 1 (Erase Block Type 1): Page
mode and Synchronous mode capabilities
Bit 0: P age-mode reads permitted
Bit 1: Synchronous reads permitted
Bit 2: Synchronous writes permitted
Bits 3-7: reserved
(P+32)h = 13Ch 06h Bank Region 1 Erase Block Type 2 Information
Bits 0-15: n+1 = number of identical-sized erase
blocks
Bits 16-31: n×256 = number of bytes in erase
block region
(P+33)h = 13Dh 00h
(P+34)h = 13Eh 00h
(P+35)h = 13Fh 02h
(P+36)h = 140h 64h Ba nk Region 1 (Erase Block Type 2)
Minimum block erase cycles × 1000
(P+37)h = 141h 00h
(P+38)h = 142h 01h
Bank Regions 1 (Erase Block Type 2): BIts per
cell, internal ECC
Bits 0-3: bits per cell in erase region
Bit 4: reserved for “internal ECC used”
BIts 5-7: reserved
(P+39)h = 143h 03h
Bank Region 1 (Erase Block Type 2): Page
mode and Synchronous mode capabilities
Bit 0: P age-mode reads permitted
Bit 1: Synchronous reads permitted
Bit 2: Synchronous writes permitted
Bits 3-7: reserved
Table 39. Bank and Erase Block region 1 information (continued)
M58LT128HST (top) M58LT128HSB
(bottom) Description
Offset Data Offset Data
M58LT128HST, M58LT128HSB Common Flash Interface
89/110
Table 40. Bank and Erase Block Region 2 Information
M58LT128HST (top) M58LT128HSB
(bottom) Description
Offset Data Offset Data
(P+32)h = 13Ch 01h (P+3A)h = 144h 0Fh Number of identical banks within Bank Region 2
(P+33)h = 13Dh 00h (P+3B)h = 145h 00h
(P+34)h = 13Eh 11h (P+3C)h = 146h 11h
Number of program or erase operations allowed
in Bank Region 2:
Bits 0-3: Number of simultaneous program
operations
Bits 4-7: Number of simultaneous erase
operations
(P+35)h = 13Fh 00h (P+3D)h = 147h 00h
Number of program or erase operations allowed
in other banks while a bank in this region is
programming
Bits 0-3: Number of simultaneous program
operations
Bits 4-7: Number of simultaneous erase
operations
(P+36)h = 140h 00h (P+3E)h = 148h 00h
Number of program or erase operations allowed
in other banks while a bank in this region is
erasing
Bits 0-3: Number of simultaneous program
operations
Bits 4-7: Number of simultaneous erase
operations
(P+37)h = 141h 02h (P+3F)h = 149h 01h
Types of erase bloc k regions in Bank Region 2
n = number of erase block regions with
contiguous same-size erase blocks.
Symmetrically blocked banks have one blocking
region.(2)
(P+38)h = 142h 06h (P+40)h = 14Ah 07h Bank Region 2 Erase Block Type 1 Information
Bits 0-15: n+1 = number of identical-sized erase
blocks
Bits 16-31: n×256 = number of bytes in erase
block region
(P+39)h = 143h 00h (P+41)h = 14Bh 00h
(P+3A)h = 144h 00h (P+42)h = 14Ch 00h
(P+3B)h = 145h 02h (P+43)h = 14Dh 02h
(P+3C)h = 146h 64h (P+44)h = 14Eh 64h Bank Region 2 (Erase Block Type 1)
Minimum block erase cycles × 1000
(P+3D)h = 147h 00h (P+45)h = 14Fh 00h
(P+3E)h = 148h 01h (P+46)h = 150h 01h
Bank Region 2 (Erase Bloc k Type 1): BIts per
cell, internal ECC
Bits 0-3: bits per cell in erase region
Bit 4: reserved for “internal ECC used”
BIts 5-7: reser ved
Common Flash Interface M58LT128HST, M58 LT128HSB
90/110
1. The variable P is a pointer which is defined at CFI offset 015h.
2. Bank Regions. There are two Bank Regions, see Table 29 and Table 30.
(P+3F)h = 149h 03h (P+47)h = 151h 03h
Bank Region 2 (Erase Bloc k Type 1):Page mode
and Synchronous mode capabilities (defined in
Table 37)
Bit 0: Page-mode reads permitted
Bit 1: Synchronous reads permitted
Bit 2: Synchronous write s permitted
Bits 3-7: reserved
(P+40)h = 14Ah 03h Bank Region 2 Erase Block Type 2 Information
Bits 0-15: n+1 = number of identical-sized erase
blocks
Bits 16-31: n×256 = number of bytes in erase
block region
(P+41)h = 14Bh 00h
(P+42)h = 14Ch 80h
(P+43)h = 14Dh 00h
(P+44)h = 14Eh 64h Bank Region 2 (Erase Block Type 2)
Minimum block erase cycles × 1000
(P+45)h = 14Fh 00h
(P+46)h = 150h 01h
Bank Region 2 (Erase Bloc k Type 2): BIts per
cell, internal ECC
Bits 0-3: bits per cell in erase region
Bit 4: reserved for “internal ECC used”
BIts 5-7: reser ved
(P+47)h = 151h 03h
Bank Region 2 (Erase Block Type 2): Page mode
and Synchronous mode capabilities (defined in
Table 37)
Bit 0: Page-mode reads permitted
Bit 1: Synchronous reads permitted
Bit 2: Synchronous write s permitted
Bits 3-7: reserved
(P+48)h = 152h (P+48)h = 152h Feature Space definitions
(P+49)h = 153h (P+43)h = 153h Reserved
Table 40. Bank and Erase Block Region 2 Information (continued)
M58LT128HST (top) M58LT128HSB
(bottom) Description
Offset Data Offset Data
M58LT128HST, M58LT128HSB Flowcharts and pseudo codes
91/110
Appendix C Flowcharts and pseudo codes
Figure 19. Program flowchart and pseudo code
1. Status check of SR1 (Protected Block), SR3 (VPP Invalid) and SR4 (Program Error) can be made after each program
operation or after a sequence.
2. If an error is found, the Status Register must be cleared before further Program/Erase Controller operations.
3. Any address within the bank can equally be used.
Write 40h or 10h (3)
AI06170b
Start
Write Address
& Data
Read Status
Register (3)
YES
NO
SR7 = 1
YES
NO
SR3 = 0
NO
SR4 = 0
VPP Invalid
Error (1, 2)
Program
Error (1, 2)
program_command (addressToProgram, dataToProgram) {:
writeToFlash (addressToProgram, 0x40);
/*writeToFlash (addressToProgram, 0x10);*/
/*see note (3)*/
do {
status_register=readFlash (addressToProgram);
"see note (3)";
/* E or G must be toggled*/
} while (status_register.SR7== 0) ;
if (status_register.SR3==1) /*VPP invalid error */
error_handler ( ) ;
YES
End
YES
NO
SR1 = 0 Program to Protected
Block Error (1, 2)
writeToFlash (addressToProgram, dataToProgram) ;
/*Memory enters read status state after
the Program Command*/
if (status_register.SR4==1) /*program error */
error_handler ( ) ;
if (status_register.SR1==1) /*program to protect block error */
error_handler ( ) ;
}
Flowcharts and pseudo codes M58LT128HST, M58LT128HSB
92/110
Figure 20. Blank Check flowchart and pseudo code
1. Any address within the bank can equally be used.
2. If an error is found, the Status Register must be cleared before further Program/Erase operations.
Write Block
Address & BCh
Start
SR7 = 1
Write Block
Address & CBh
Read
Status Register (1)
SR4 = 1
SR5 = 1
SR5 = 0
NO
YES
Command Sequence
Error (2)
YES
Blank Check Error (2)
NO
End
blank_check_command (blockToCheck) {
writeToFlash (blockToCheck, 0xBC);
writeToFlash (blockToCheck, 0xCB);
/* Memory enters read status state after
the Blank Check Command */
do {
status_register = readFlash (blockToCheck);
/* see note (1) */
/* E or G must be toggled */
} while (status_register.SR7==0);
if (status_register.SR4==1) && (status_register.SR5==1)
/* command sequence error */
error_handler () ;
if (status_register.SR5==1)
/* Blank Check error */
error_handler () ;
}
ai10520c
M58LT128HST, M58LT128HSB Flowcharts and pseudo codes
93/110
Figure 21. Buffer Program flowchart and pseudo code
1. n + 1 is the number of data being programmed.
2. Next Program data is an element belonging to buffer_Program[].data; Next Program address is an element belonging to
buffer_Program[].address
3. Routine for Error Check by reading SR3, SR4 and SR1.
Buffer Program E8h
Command,
Start Address
AI08913b
Start
Write Buffer Data,
Start Address
YES
X = n
End
NO
Write n
(1)
,
Start Address
X = 0
Write Next Buffer Data,
Next Program Address
X = X + 1
Program
Buffer to Flash
Confirm D0h
Read Status
Register
NO
SR7 = 1
YES
Full Status
Register Check
(3)
(2)
Read Status
Register
NO
SR7 = 1
YES
Buffer_Program_command (Start_Address, n, buffer_Program[] )
/* buffer_Program [] is an array structure used to store the address and
data to be programmed to the Flash memory (the address must be within
the segment Start Address and Start Address+n) */
{do {writeToFlash (Start_Address, 0xE8) ;
status_register=readFlash (Start_Address);
} while (status_register.SR7==0);
writeToFlash (Start_Address, n);
writeToFlash (buffer_Program[0].address, buffer_Program[0].data);
/*buffer_Program[0].address is the start address*/
x = 0;
while (x<n)
{ writeToFlash (buffer_Program[x+1].address, buffer_Program[x+1].data);
x++;
}
writeToFlash (Start_Address, 0xD0);
do {status_register=readFlash (Start_Address);
} while (status_register.SR7==0);
full_status_register_check();
}
Flowcharts and pseudo codes M58LT128HST, M58LT128HSB
94/110
Figure 22. Program Suspend & Resume flowchart and pseudo code
1. The Read Status Register command (Write 70h) can be issued just before or just after the Program Resume command.
Write 70h
AI10117b
Read Status
Register
YES
NO
SR7 = 1
YES
NO
SR2 = 1
Write D0h
Read data from
another address
Start
Write B0h
Program Complete
Write FFh
program_suspend_command ( ) {
writeToFlash (any_address, 0xB0) ;
writeToFlash (bank_address, 0x70) ;
/* read status register to check if
program has already completed */
do {
status_register=readFlash (bank_address) ;
/* E or G must be toggled*/
} while (status_register.SR7== 0) ;
if (status_register.SR2==0) /*program completed */
{ writeToFlash (bank_address, 0xFF) ;
read_data ( ) ;
/*The device returns to Read Array
(as if program/erase suspend was not issued).*/
}
else
{ writeToFlash (bank_address, 0xFF) ;
read_data ( ); /*read data from another address*/
writeToFlash (any_address, 0xD0) ;
/*write 0xD0 to resume program*/
writeToFlash (bank_address, 0x70) ;
/*read status register to check if program has completed */
}
}
Write FFh
Program Continues with
Bank in Read Status
Register Mode
Read Data
Write 70h
(1)
M58LT128HST, M58LT128HSB Flowcharts and pseudo codes
95/110
Figure 23. Block Erase flo wchart and pseudo code
1. If an error is found, the Status Register must be cleared before further Program/Erase operations.
2. Any address within the bank can equally be used.
Write 20h (2)
AI10976
Start
Write Block
Address & D0h
Read Status
Register (2)
YES
NO
SR7 = 1
YES
NO
SR3 = 0
YES
SR4, SR5 = 1
VPP Invalid
Error (1)
Command
Sequence Error (1)
NO
NO
SR5 = 0 Erase Error (1)
End
YES
NO
SR1 = 0 Erase to Protected
Block Error (1)
YES
erase_command ( blockToErase ) {
writeToFlash (blockToErase, 0x20) ;
/*see note (2) */
writeToFlash (blockToErase, 0xD0) ;
/* Memory enters read status state after
the Erase Command */
} while (status_register.SR7== 0) ;
do {
status_register=readFlash (blockToErase) ;
/* see note (2) */
/* E or G must be toggled*/
if (status_register.SR3==1) /*VPP invalid error */
error_handler ( ) ;
if ( (status_register.SR4==1) && (status_register.SR5==1) )
/* command sequence error */
error_handler ( ) ;
if (status_register.SR1==1) /*program to protect block error */
error_handler ( ) ;
if ( (status_register.SR5==1) )
/* erase error */
error_handler ( ) ;
}
Flowcharts and pseudo codes M58LT128HST, M58LT128HSB
96/110
Figure 24. Erase Suspend & Resume flowchart and pseudo code
1. The Read Status Register command (Write 70h) can be issued just before or just after the Erase Resume command.
Write 70h
AI13893
Read Status
Register
YES
NO
SR7 = 1
YES
NO
SR6 = 1
Erase Continues
Write D0h
Read data from another block,
Program,
Set Configuration Register or
Block Protect/Unprotect/Lock
Start
Write B0h
Erase Complete
Write FFh
Read Data
Write FFh
erase_suspend_command ( ) {
writeToFlash (bank_address, 0xB0) ;
writeToFlash (bank_address, 0x70) ;
/* read status register to check if
erase has already completed */
do {
status_register=readFlash (bank_address) ;
/* E or G must be toggled*/
} while (status_register.SR7== 0) ;
if (status_register.SR6==0) /*erase completed */
{ writeToFlash (bank_address, 0xFF) ;
read_data ( ) ;
/*read data from another block*/
/*The device returns to Read Array
(as if program/erase suspend was not issued).*/
}
else
{ writeToFlash (bank_address, 0xFF) ;
read_program_data ( );
/*read or program data from another address*/
writeToFlash (bank_address, 0xD0) ;
/*write 0xD0 to resume erase*/
}
}
M58LT128HST, M58LT128HSB Flowcharts and pseudo codes
97/110
Figure 25. Protect/Unprotect operation flowchart and pseudo code
1. Any address within the bank can equally be used.
Write
01h, D0h
AI12895
Read Block
Protect State
YES
NO
Protection
change
confirmed?
Start
Write 60h (1) protect_operation_command (address, protect_operation) {
writeToFlash (address, 0x60) ; /*configuration setup*/
/* see note (1) */
if (readFlash (address) ! = protection_state_expected)
error_handler () ;
/*Check the protection state (see Read Block Signature table )*/
writeToFlash (address, 0xFF) ; /*Reset to Read Array mode*/
/*see note (1) */
}
Write FFh (1)
Write 90h (1)
End
if (protect_operation==PROTECT) /*to protect the block*/
writeToFlash (address, 0x01) ;
else if (protect_operation==UNPROTECT) /*to unprotect the block*/
writeToFlash (address, 0xD0) ;
writeToFlash (address, 0x90) ;
/*see note (1) */
Flowcharts and pseudo codes M58LT128HST, M58LT128HSB
98/110
Figure 26. Protection Register Program flowc hart and pseudo code
1. Status check of SR1 (Protected Block), SR3 (VPP Invalid) and SR4 (Program Error) can be made after each program
operation or after a sequence.
2. If an error is found, the Status Register must be cleared before further Program/Erase Controller operations.
3. Any address within the bank can equally be used.
Write C0h (3)
AI06177b
Start
Write Address
& Data
Read Status
Register (3)
YES
NO
SR7 = 1
YES
NO
SR3 = 0
NO
SR4 = 0
VPP Invalid
Error (1, 2)
Program
Error (1, 2)
protection_register_program_command (addressToProgram, dataToProgram) {:
writeToFlash (addressToProgram, 0xC0) ;
/*see note (3) */
do {
status_register=readFlash (addressToProgram) ;
/* see note (3) */
/* E or G must be toggled*/
} while (status_register.SR7== 0) ;
if (status_register.SR3==1) /*VPP invalid error */
error_handler ( ) ;
YES
End
YES
NO
SR1 = 0 Program to Protected
Block Error (1, 2)
writeToFlash (addressToProgram, dataToProgram) ;
/*Memory enters read status state after
the Program Command*/
if (status_register.SR4==1) /*program error */
error_handler ( ) ;
if (status_register.SR1==1) /*program to protect block error */
error_handler ( ) ;
}
M58LT128HST, M58LT128HSB Flowcharts and pseudo codes
99/110
Figure 27. Buffer Enhanced Factory Program flowchart and pseudo code
Write 80h to
Address WA1
AI12898
Start
Write D0h to
Address WA1
Write FFFFh to
Address = NOT WA1
Read Status
Register
SR7 = 0
NO
NO
SR0 = 0
YES
Read Status Register
SR3 and SR1for errors
Exit
Write PDX
Address WA1
Increment Count
X = X + 1
Initialize count
X = 0
X = 32
YES
Read Status
Register
Last data?
YES
Read Status
Register
SR7 = 1
YES
Full Status Register
Check
End
YES
SR4 = 1
NO
NO
NO
NO
SETUP PHASE
PROGRAM AND
VERIFY PHASE
EXIT PHASE
Buffer_Enhanced_Factory_Program_Command
(start_address, DataFlow[]) {
writeToFlash (start_address, 0x80) ;
writeToFlash (start_address, 0xD0) ;
do {
do {
status_register = readFlash (start_address);
if (status_register.SR4==1) { /*error*/
if (status_register.SR3==1) error_handler ( ) ;/*VPP error */
if (status_register.SR1==1) error_handler ( ) ;/* Protected Block */
}
while (status_register.SR7==1)
x=0; /* initialize count */
do {
writeToFlash (start_address, DataFlow[x]);
x++;
}while (x<32)
do {
status_register = readFlash (start_address);
}while (status_register.SR0==1)
} while (not last data)
writeToFlash (another_block_address, FFFFh)
do {
status_register = readFlash (start_address)
}while (status_register.SR7==0)
full_status_register_check();
}
Command interface state tables M58LT128HST, M58LT128HSB
100/110
Appendix D Command interface state tables
Table 41. Command Interface states - modify table, next state(1)
Current CI State
Command Input
Read
Array(2)
(FFh)
Program
Setup(3)(4)
(10/40h)
Buffer
Program
(3)(4)
(E8h)
Block
Erase,
Setup(3)(4)
(20h)
BEFP
Setup
(80h)
Blank
Check
setup
(BCh)
Erase
Confirm
P/E Resume,
Block
Unprotect
confirm,
BEFP
Confirm(3)(4)
(D0h)
Blank
Check
confirm
(CBh)
Buffer
Program,
Program/
Erase
Suspend
(B0h)
Read
Status
Register
(70h)
Clear
Status
Register
(5)
(50h)
Read
Electronic
Signature
, Read
CFI Query
(90h, 98h)
Ready Ready Program
Setup BP
Setup Erase
Setup BEFP
Setup
Blank
Check
setup Ready
Protect/CR Setup Ready (Protect Error) Ready
(unprotect
block) Ready (Protect Error)
OTP
Setup OTP Busy
Busy OTP
Busy IS in OTP
Busy OTP
busy IS in OTP Busy OTP Busy
IS in
OTP
busy OT P Bu sy
Program
Setup Program Busy
Busy Program
Busy
IS in
Program
Busy
Program
Busy IS in Program
Busy Program Busy Program
Suspend Program Bu sy
IS in
Program
Busy Program Busy
Suspend PS IS in PS PS IS in Program
Suspend PS Program Busy Program Suspend
IS in PS Program Suspend
Buffer
Program
Setup Buffer Program Load 1 (give word count load (N-1));
Buffer
Load 1 if N=0 go to Buffer Program Confirm. Else (N 0) go to Buffer Program Load 2 (data load)
Buffer
Load 2 Buffer Program Confirm when count =0; Else Buffer Program Load 2
(note: Buffer Progr am wil l fail at this point if any block address is different from the first addre ss)
Confirm Ready (error) BP Busy Ready (error)
Busy BP Busy IS in BP
Busy BP Busy IS in BP Busy BP Busy BP
Suspend Buffer Program Busy
IS in BP
Busy Buffer Program Busy
Suspend BP
Suspend IS in BP
Suspend BP
Suspend IS in BP Suspe nd BP
Suspend BP busy Buff er Program Suspend
IS in BP
Suspend Buffer Program Suspend
M58LT128HST, M58LT128HSB Command interface state tables
101/110
Erase
Setup Ready (error) Erase Busy Ready (error)
Busy Erase
Busy IS in
Erase
Busy Erase
Busy IS in Erase Busy Erase Busy Erase
Suspend Erase Busy
IS in
Erase
Busy Erase Busy
Suspend Erase
Suspend Program
in
ES
BP in ES IS in Erase
Suspend ES Erase Busy Erase Suspend
IS in ES Erase Suspend
Program
in Erase
Suspend
Setup Program Busy in Erase Suspend
Busy Program
Busy in
ES
IS in
Program
Busy in
ES
Program
Busy in
ES
IS in Program
Busy in ES Pr o gram Bu sy in ES P S i n ES Program Busy in Erase
Suspend
IS in
Program
busy in
ES
Program busy in Erase Suspend
Suspend PS in ES IS in PS in
ES PS in ES IS in Program
Suspend in ES PS in ES Program Busy
in ES Program Suspend in Erase Suspend
IS in PS
in ES Program Suspend in Erase Suspend
Buffer
Program
in Erase
Suspend
Setup Buffer Program Load 1 in Erase Suspend (give wo rd count load (N-1)); if N=0 go to Buffer Program confirm. Else (N 0) go to
Buffer Program Load 2
Buffer
Load 1 Buffer Program Load 2 in Erase Suspend (dat a l oad)
Buffer
Load 2 Buffer Prog ram Conf irm in Erase Suspend when count =0; Else Buffer Program Load 2 in Erase Suspend (note: Buffer Program
will fail at this poin t if any block address is different from the first address)
Confirm Erase Suspend (sequence error) BP Busy in ES Erase Suspend (sequence error)
Busy BP Busy
in ES
IS in BP
Busy in
ES
BP busy
in ES IS in BP busy in
ES BP Busy in ES BP
Suspend
in ES Buffer Program Busy in ES
IS in BP
busy in
ES Buffer Program Busy in Erase Suspend
Suspend BP
Suspend
in ES
IS in BP
Suspend
in ES
BP
Suspend
in ES IS in BP Suspend
in Erase Suspend BP
Suspend
in ES
BP Busy in
Erase
Suspend Buffer Program Suspend in Erase Suspend
IS in BP
Suspend
in ES BP Suspend in Erase Suspend
Table 41. Command Interface states - modify table, next state(1) (continued)
Current CI State
Command Input
Read
Array(2)
(FFh)
Program
Setup(3)(4)
(10/40h)
Buffer
Program
(3)(4)
(E8h)
Block
Erase,
Setup(3)(4)
(20h)
BEFP
Setup
(80h)
Blank
Check
setup
(BCh)
Erase
Confirm
P/E Resume,
Block
Unprotect
confirm,
BEFP
Confirm(3)(4)
(D0h)
Blank
Check
confirm
(CBh)
Buffer
Program,
Program/
Erase
Suspend
(B0h)
Read
Status
Register
(70h)
Clear
Status
Register
(5)
(50h)
Read
Electronic
Signature
, Read
CFI Query
(90h, 98h)
Command interface state tables M58LT128HST, M58LT128HSB
102/110
Blank
Check
Setup Ready (error) Blank
Check
busy Ready (error)
Busy Blank
Check
busy
IS in Blank
Check
busy
Blank
Check
busy
IS in Blank Check
busy Blank Check busy
Protect/CR Setup
in Erase Suspend Erase Suspend (Protect Error) Erase
Suspend Erase Suspend (Protect Error)
Buffer
EFP
Setup Ready (error) BEFP Busy Ready (error)
Busy BEFP Busy(6)
1. CI = Command Interface, CR = Configuration register, BEFP = Buffer Enhanced Factory program, P/E C = Program/Erase
controller, IS = Illegal State, BP = Buffer Program, ES = Erase Suspend.
2. At power-up, all banks are in Read Array mode. Issuing a Read Array command to a busy bank, results in undetermined
data output.
3. The two cycle command should be issued to the same bank address.
4. If the P/E C is active, both cycles are ignored.
5. The Clear Status Register command clears the SR error bits except when the P/E C. is busy or suspended.
6. BEFP is allowed only when Status Register bit SR0 is reset to '0'. BEFP is busy if Block Address is first BEFP Address. Any
other commands are treated as data.
Table 41. Command Interface states - modify table, next state(1) (continued)
Current CI State
Command Input
Read
Array(2)
(FFh)
Program
Setup(3)(4)
(10/40h)
Buffer
Program
(3)(4)
(E8h)
Block
Erase,
Setup(3)(4)
(20h)
BEFP
Setup
(80h)
Blank
Check
setup
(BCh)
Erase
Confirm
P/E Resume,
Block
Unprotect
confirm,
BEFP
Confirm(3)(4)
(D0h)
Blank
Check
confirm
(CBh)
Buffer
Program,
Program/
Erase
Suspend
(B0h)
Read
Status
Register
(70h)
Clear
Status
Register
(5)
(50h)
Read
Electronic
Signature
, Read
CFI Query
(90h, 98h)
M58LT128HST, M58LT128HSB Command interface state tables
103/110
Table 42. Command Interface states - modify table, next output state(1) (2)
Current CI State
Command Input
Read
Array
(3)
(FFh)
Program
Setup(4)
(5)
(10/40h)
Buffer
Program
(E8h)
Block
Erase,
Setup(4)
(5)
(20h)
BEFP
Setup
(80h)
Blank
Check
setup
(BCh)
Erase Confirm
P/E Resume,
Block
Unprotect
confirm, BEFP
Confirm(4)(5)
(D0h)
Blank
Check
confirm
(CBh)
Program/
Erase
Suspend
(B0h)
Read
Status
Register
(70h)
Clear
Status
Register
(50h)
Read
Electronic
signature,
Read CFI
Query
(90h, 98h)
Program Setup
Status Register
Erase Setup
OT P Se tup
Program Setup in
Erase Suspend
BEFP Setup
BEFP Busy
Buffer Program
Setup
Buffer Program
Load 1
Buffer Program
Load 2
Buffer Program
Confirm
Buffer Program
Setup in Erase
Suspend
Buffer Program
Load 1 in Erase
Suspend
Buffer Program
Load 2 in Erase
Suspend
Buffer Program
Confirm in Erase
Suspend
Blank Check setup
Protect/CR Setup
Protect/CR Setup in
Erase Suspend
Command interface state tables M58LT128HST, M58LT128HSB
104/110
OTP Busy
Array Status Register Output Unchanged Status
Register
Output
Unchang
ed
Status
Register
Ready
Electronic
Signature/
CFI
Program Busy
Erase Busy
Buffer Program
Busy
Program/Erase
Suspend
Buffer Program
Suspend
Program Busy in
Erase Suspend
Buffer Program
Busy in Erase
Suspend
Program Suspend
in Erase Suspend
Buffer Program
Suspend in Erase
Suspend
Blank Check busy
Illegal Stat e Output Unchanged
1. The output state shows the type of data that appears at the outputs if the bank address is the same as the command
address. A bank can be placed in Read Array, Read Status Register, Read Electronic Signature or Read CFI mode,
depending on the command issued. Each bank remains in its last output state until a new command is issued to that bank.
The next state does not depend on the bank output state.
2. CI = Command Interface, CR = Configuration Register, BEFP = Buffer Enhanced Factory Program, P/E. C. =
Program/Erase Controller.
3. At Power-Up, all banks are in Read Array mode. Issuing a Read Array command to a busy bank, results in undetermined
data output.
4. The two cycle command should be issued to the same bank address.
5. If the P/E.C. is active, both cycles are ignored.
Table 42. Command Interface states - modify table, next output state(1) (2) (continued)
Current CI State
Command Input
Read
Array
(3)
(FFh)
Program
Setup(4)
(5)
(10/40h)
Buffer
Program
(E8h)
Block
Erase,
Setup(4)
(5)
(20h)
BEFP
Setup
(80h)
Blank
Check
setup
(BCh)
Erase Confirm
P/E Resume,
Block
Unprotect
confirm, BEFP
Confirm(4)(5)
(D0h)
Blank
Check
confirm
(CBh)
Program/
Erase
Suspend
(B0h)
Read
Status
Register
(70h)
Clear
Status
Register
(50h)
Read
Electronic
signature,
Read CFI
Query
(90h, 98h)
M58LT128HST, M58LT128HSB Command interface state tables
105/110
Table 43. Command interface states - lock table, next state(1)
Current CI State
Command Input
Protect/CR
Setup(2)
(60h)
OTP
Setup(2)
(C0h)
Block
Protect
Confirm
(01h)
Set CR
Confirm
(03h)
Block
Address
(WA0)(3)
(XXXXh)
Illegal
Command(4) P/E C
operation
completed(5)
Ready Protect/CR Setup OTP Setup Ready N/A
Protect/CR Setup Ready (Protect error) Ready Ready (Protect error) N/A
OTP
Setup OTP Busy N/A
Busy IS in OTP Busy O TP Busy Ready
IS in OTP busy OTP Busy IS Ready
Program
Setup Program Busy N/A
Busy IS in Program Bu sy Program Bus y Ready
IS in Program busy Program busy IS Ready
Suspend IS in PS Program Suspend N/A
IS in PS Program Suspend
Buffer
Program
Setup Buffer Program Load 1 (give word count load (N-1)); N/A
Buffer Load 1 Buffer Program Load 2(6) Exit see no te (6) N/A
Buffer Load 2 Buf f er Pr ogr am Confirm when count =0; Else Buffer Program Load 2 (note: Buffer Program
will fail at this point if any block address is different from the first address) N/A
Confirm Ready (error) N/A
Busy IS in BP Busy Buffer Program Busy Ready
IS in Buffer Program
busy Buffer Program Busy IS Ready
Suspend IS in BP Suspend Buffer Program Suspend N/A
IS in BP Suspend Buffer Program Suspend
Erase
Setup Ready (error) N/A
Busy IS in Erase Busy Erase Busy Ready
IS in Erase busy Erase Busy IS ready
Suspend Protect/CR Setup
in ES IS in ES Erase Suspend N/A
IS in ES Erase Suspend
Command interface state tables M58LT128HST, M58LT128HSB
106/110
Program
in Erase
Suspend
Setup Program Busy in Erase Suspend N/A
Busy IS in Program busy in ES Program Busy in Erase Suspend ES
IS in Program busy in
ES Program Busy in Erase Suspend IS in ES
Suspend IS in PS in ES Program Suspend in Erase Suspend N/A
IS in PS in ES Program Suspend in Erase Suspend
Buffer
Program
in Erase
Suspend
Setup Buffer Program Load 1 in Erase Suspend (give word count load (N-1))
N/A
Buffer Load 1 Buffer Program Load 2 in Erase Suspend(7) Exit see note (7)
Buffer Load 2 Buffer Program Confirm in Erase Suspend when count =0; Else Buffer Program Load 2 in
Erase Suspend (note: Buffer Program will fail at this point if any block address is different
from the first address)
Confirm Erase Suspend (sequence error)
Busy IS in BP busy in ES Buffer Program Busy in Erase Suspe nd ES
IS in BP busy in ES BP busy in ES IS in ES
Suspend IS in BP suspend in ES Buffer Program Suspend in Erase Suspend N/A
IS in BP Suspend in ES Buffer Program Suspend in Erase Suspend
Blank
Check
Setup Ready (error) N/A
Blank Check busy IS in Blank Check busy Blank Check busy Ready
Protect/CR Setup in ES Erase Suspend (Protect erro r) Erase Suspend Erase Suspend (Protect
error) N/A
BEFP Setup Ready (error) N/A
Busy BEFP Busy(8) Exit BEFP Busy(8) N/A
1. CI = Command Interface, CR = Configuration register, BEFP = Buffer Enhanced Factory program, P/E C = Program/Erase
controller, IS = Illegal State, BP = Buffer program, ES = Erase suspend, WA0 = Address in a block different from first BEFP
address.
2. If the P/E C is active, both cycle are ignored.
3. BEFP Exit when Block Address is different from first Block Address and data are FFFFh.
4. Illegal commands are those not defined in the command set.
5. N/A: not available. In this case the state remains unchanged.
6. If N=0 go to Buffer Program Confirm. Else (not =0) go to Buffer Program Load 2 (data load)
7. If N=0 go to Buffer Program Confirm in Erase suspend. Else (not =0) go to Buffer Program Load 2 in Erase suspend.
8. BEFP is allowed only when Status Register bit SR0 is set to '0'. BEFP is busy if Block Address is first BEFP Address. Any
other commands are treated as data.
Table 43. Command interface states - lock table, next state(1) (continued)
Current CI State
Command Input
Protect/CR
Setup(2)
(60h)
OTP
Setup(2)
(C0h)
Block
Protect
Confirm
(01h)
Set CR
Confirm
(03h)
Block
Address
(WA0)(3)
(XXXXh)
Illegal
Command(4) P/E C
operation
completed(5)
M58LT128HST, M58LT128HSB Command interface state tables
107/110
Table 44. Command interface states - lock table, next output state (1) (2)
Current CI State
Command Input
Protect/CR
Setup(3)
(60h)
Blank
Check
setup (BCh)
OTP
Setup(3)
(C0h)
Blank Check
confirm
(CBh)
Block Pr otect
Confirm (01h)
Set CR
Confirm
(03h)
BEFP
Exit(4)
(FFFFh)
Illegal
Command(5) P. E./C.
Operation
Completed
Program Setup
Status Register
Output
Unchanged
Erase Setup
OTP Setup
Program Setup in Erase
Suspend
BEFP Setup
BEFP Busy
Buffer Program Setup
Buffer Program Load 1
Buffer Program Load 2
Buffer Program Confirm
Buffer Program Setup in
Erase Suspend
Buffer Program Load 1 in
Erase Suspend
Buffer Program Load 2 in
Erase Suspend
Buffer Program Confirm in
Erase Suspend
Blank Check setup
Protect/CR Setup
Status Register Array Status Register
Protect/CR Setup in Erase
Suspend
Command interface state tables M58LT128HST, M58LT128HSB
108/110
OT P Busy
Status Register Output Unchanged Array Output Unchanged
Ready
Program Busy
Erase Busy
Buffer Program Busy
Program/Erase Suspend
Buffer Program Suspend
Program Busy in Erase
Suspend
Buffer Program Busy in
Erase Suspend
Program Suspend in Erase
Suspend
Buffer Program Suspend in
Erase Suspend
Blank Check busy
Illegal Stat e Output Unchanged
1. The output state shows the type of data that appears at the outputs if the bank address is the same as the command
address. A bank can be placed in Read Array, Read Status Register, Read Electronic Signature or Read CFI mode,
depending on the command issued. Each bank remains in its last output state until a new command is issued to that bank.
The next state does not depend on the bank's output state.
2. CI = Command Interface, CR = Configuration Register, BEFP = Buffer Enhanced Factory Program, P/E. C. =
Program/Erase Controller.
3. If the P/E.C. is active, both cycles are ignored.
4. BEFP Exit when Block Address is different from first Block Address and data are FFFFh.
5. Illegal commands are those not defined in the command set.
Table 44. Command interface states - lock table, next output state (continued)(1) (2)
Current CI State
Command Input
Protect/CR
Setup(3)
(60h)
Blank
Check
setup (BCh)
OTP
Setup(3)
(C0h)
Blank Check
confirm
(CBh)
Block Pr otect
Confirm (01h)
Set CR
Confirm
(03h)
BEFP
Exit(4)
(FFFFh)
Illegal
Command(5) P. E./C.
Operation
Completed
M58LT128HST, M58LT128HSB Revision history
109/110
Revision history
Table 45. Document revision history
Date Revision Changes
02-Mar-2007 1 Initial release.
M58LT128HST, M58LT128HSB
110/110
Please Read Carefully:
Information in this document is provided solely in connection with ST products. STMicroelectronics NV and its subsidiaries (“ST”) reserve the
right to make changes, corrections, modifications or improvements, to this document, and the products and services described herein at any
time, without notice.
All ST products are sold pursuant to ST’s terms and conditions of sale.
Purchasers a re so lel y res ponsibl e fo r th e choic e, se lecti on an d use o f th e ST pr oduc ts and s ervi ces d escr ibed he rein , and ST as sumes no
liability whatsoever relating to the choice, selection or use of the ST products and services described herein.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted under this document. If any part of this
document ref er s to an y t hi rd pa rt y p roduc t s or serv ic es it sh al l n ot be dee med a li ce nse gr an t by ST for t he use of su ch t hi rd party products
or services, or any intel lectual pro perty conta ined therei n or considere d as a warranty covering the use in any mann er whatsoev er of such
third party products or services or any intellectual property contained therein.
UNLESS OTHERWISE SET FORTH IN ST’S TERMS AND CONDITIONS OF SALE ST DISCLAIMS ANY EXPRESS OR IMPLIED
WARRANTY WITH RESPECT TO THE USE AND/OR SALE OF ST PRODUCTS INCLUDING WITHOUT LIMITATION IMPLIED
WARRANTIES OF MERCHANTAB ILIT Y, FITNESS F OR A PARTI CULAR PURPOS E (AND THEIR EQUIVALE NTS UNDER THE LAWS
OF ANY JURISDICTION), OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT.
UNLESS EXPRESSLY APPROVED IN WRITING BY AN AUTHORIZED ST REPRESENTATIVE, ST PRODUCTS ARE NOT
RECOMMENDED, AUTHORIZED OR WARRANTED FOR USE IN MILITARY, AIR CRAFT, SPACE, LIFE SAVING, OR LIFE SUSTAINING
APPLICATIONS, NOR IN PRODUCTS OR SYSTEMS WHERE FAILURE OR MALFUNCTION MAY RESULT IN PERSONAL INJURY,
DEATH, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE. ST PRODUCTS WHICH ARE NOT SPECIFIED AS "AUTOMOTIVE
GRADE" MAY ONLY BE USED IN AUTOMOTIVE APPLICATIONS AT USER’S OWN RISK.
Resale of ST products with provisions different from the statements and/or technical features set forth in this document shall immediately void
any warrant y granted by ST for the S T product or se rvice descr ibed herein a nd shall no t create or e xtend in any manner whatsoe ver, any
liability of ST.
ST and the ST lo go are trademarks or registered trademarks of ST in various countries.
Information in this document supersedes and replaces all information previously supplied.
The ST logo is a registered trademark of STMicroelectronics. All other names are the property of their respective owners.
© 2007 STMicroelectronics - All rights reserved
STMicroele ctr on ic s gr ou p of companies
Australia - Belgium - Brazil - Canada - China - Czech Republic - Finland - France - Germany - Hong Kong - India - Israel - Italy - Japan -
Malaysia - Malta - Morocco - Singapore - Spain - Sweden - Switzerland - United Kingdom - United States of America
www.st.com