The NFS110 series is a 110 W universal input ac-dc power supply
on a 7 x 4.25 inch card. The NFS110 series has four single and
three quad output models and has proven itself to be highly
reliable and versatile product for a wide range of communication
and industrial applications, with a very high peak current
capability on each output for drive and motor applications. The
NFS110 provides 80 W of output power with free air convection
cooling which can be boosted to 110 W with 20 CFM of air.
Standard features include overvoltage and short circuit
protection. The series, with full international safety approval and
the CE mark, meets conducted emissions EN55022 level B. The
NFS110 series is designed for use in low power data networking,
computer, telecom and industrial applications such as servers,
thermal printers, storage devices, vending machines and POS
equipment.
Embedded Power for
Business-Critical Continuity
NFS110 Series
Single and
quad output
Special Features
• 7.0 x 4.25 x 1.8 inch package
• Overvoltage and
short circuit protection
• 110 W with 20 CFM
• Adjustable outputs
• EN55022, EN55011
conducted emissions level B
• UL, VDE and CSA
safety approvals
• CE mark
• Available RoHS compliant
• 2 year warranty
Total Power: 80 - 110W
Input Voltage: 85 - 264VAC
120 - 370VDC
# of Outputs: Single, quad
Safety
VDE0805/EN60950/
IEC950/IEC1010
File No. 10401-3336-0213
Licence No. 40014677
UL1950 File No. E136005
CSA C22.2 No. 950
File No. LR41062C
Rev.02.16.07
NFS110 Series
1 of 4
Rev.02.16.07
NFS110 Series
2 of 4
Embedded Power for
Business-Critical Continuity
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
Specifications
GENERAL SPECIFICATIONS
Hold-up time 110 Vac @ 80 W 35 ms
110 Vac @ 110 W 17 ms
230 Vac @ 80 W 140 ms
230 Vac @ 110 W 100 ms
Efficiency Multiple outputs 70% typical
+5.1 V single 70% typical
12 V and 15 V singles 72% typical
24 V single 75% typical
Isolation voltage Input/output 3000 Vac
Input/chassis 1500 Vac
Switching frequency At 100 Watts output 20-70 kHz
At zero load 100-250 kHz
Approvals and VDE0805, EN60950, IEC950
standards IEC1010, UL1950
(See Note 12) CSA C22.2 No. 950
Weight Singles 550 g (19.4 oz)
Multiple outputs 600 g (21.2 oz)
MTBF (See Note 9) MIL-HDBK-217E 125,000 hours
ENVIRONMENTAL SPECIFICATIONS
Thermal performance Operating, see curve 0 °C to +70 °C
(See Notes 9, 10) Non-operating –40 °C to +85 °C
0 °C to +50 °C, 80 W
amb. convection cooled
+50 °C to +70 °C, Derate 2 W/°C
amb. convection cooled
0 °C to +50 °C, 110 W
20 CFM forced air
+50 °C to +70 °C, Derate
20 CFM forced air 2.75 W/°C
Peak, 0 °C to +50 °C, 110 W
max. 60 seconds
Relative humidity Non-condensing 5% to 95% RH
Altitude Operating 10,000 feet max.
Non-operating 40,000 feet max.
Vibration (See Note 11) 5-500 Hz 2.4 G approx.
OUTPUT SPECIFICATIONS
Voltage adjustability +5.1 V o/p on multi’s ±3.0%
5.1 V single output ±3.0%
12 V single output 12-14 V
15 V single output 15-18 V
24 V single output 24-30 V
Line regulation LL to HL, FL ±0.1% max.
All outputs on all units
Overshoot/undershoot At turn-on 0%
Temperature coefficient All outputs ±0.02%/°C
Overvoltage protection
Multi o/p 5.1 V only 6.25 V ±0.75 V
5.1 V single 6.25 V ±0.75 V
12 V single 15.75 V ±1.0 V
15 V single 22 V ±1.5 V
24 V single 33 V ±2.5 V
Output power limit Primary power Pin max. 160 W
limited Pout min. 110 W
Minimum output current (See Note 13) 0 A
Short circuit protection Burst mode operation
INPUT SPECIFICATIONS
Input voltage range 85-264 Vac
120-370 Vdc
Input frequency range 47-440 Hz
Input surge current 230 Vac 35 A
Safety ground 110 Vac, 50 Hz 0.2 mA, max.
leakage current 230 Vac, 50 Hz 0.4 mA, max.
EMC CHARACTERISTICS
Conducted emissions EN55022, FCC part 15 Level B
Radiated emissions EN55022, FCC part 15 Level A
ESD air EN61000-4-2, level 3 Perf. criteria 1
ESD contact EN61000-4-2, level 4 Perf. criteria 1
Surge EN61000-4-5, level 3 Perf. criteria 1
Fast transients EN61000-4-4, level 3 Perf. criteria 1
Radiated immunity EN61000-4-3, level 3 Perf. criteria 2
Conducted immunity EN61000-4-6, level 3 Perf. criteria 1
Rev.02.16.07
NFS110 Series
3 of 4
Embedded Power for
Business-Critical Continuity
Specifications Contd.
Notes
1Convection cooled, 80 W maximum.
2Peak outputs lasting less than 60 seconds with duty cycle less than 10%. Total
peak power must not exceed 110 W.
3Forced air, 20 CFM at 1 atmosphere, 110 W maximum.
4Figure is peak-to-peak. Output ripple is measured across a 50 MHz bandwidth
using a 12 inch twisted pair terminated with a 47 μF capacitor.
5Total regulation is defined as the static output regulation at 25 °C, including
initial tolerance, line voltage within stated limits and output voltages adjusted
to their factory settings.
6To achieve stated regulation on the 24 V output on the NFS110-7602PJ, the
following load condition must be true: IA/ IB≤ 5, where:
IA= +5.1 V output current, and
IB= +24 V output current
The +24 V output will maintain ±5.0% regulation under the following additional
condition: IA≤ 5 A.
7Single output models have floating outputs which may be referenced as either
positive or negative. Higher voltage supplies may be adjusted over a wide
output voltage range, as long as the total output power does not exceed 80
Watts (natural convection) or 110 Watts (forced air).
8Power fail detect not available on single output models.
9Derating curve is application specific for ambient temperatures >50 °C, for
optimum reliability no part of the heatsink should exceed 90 ºC and no
semiconductor case temperature should exceed 100 ºC.
10 Caution: Allow a minimum of 1 second after disconnecting the power when
making thermal measurements.
11 Three orthogonal axes, random vibration, 10 minute test for each axis.
12 This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
13 Artesyn Technologies recommends a minimum load of 11 W to achieve the
design MTBF. See the derating curve on page 3.
14 The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant. TSE
RoHS 5/6 (non Pb-free) compliant versions may be available on special request,
please contact your local sales representative for details.
15 NOTICE: Some models do not support all options. Please contact your local
Artesyn representative or use the on-line model number search tool at
http://www.artesyn.com/powergroup/products.htm to find a suitable
alternative.
OUTPUT OUTPUT CURRENTS RIPPLE (4) TOTAL MODEL NUMBERS (13,14,F)
VOLTAGE MAX (1) PEAK (2) FAN (3) REGULATION (5)
+5.1 V 8 A 20 A 10 A 50 mV ±2.0% NFS110-7601PJ
+12 V 4.5 A 9 A 5 A 120 mV ±3.0%
–12 V 0.5 A 1.5 A 1 A 120 mV ±3.0%
–5 V 0.5 A 1.5 A 1 A 50 mV ±3.0%
+5.1 V (IA) 8 A 20 A 10 A 50 mV ±2.0% NFS110-7602PJ (6)
+24 V (IB)(6) 3.5 A 4.5 A 4.5 A 240 mV +10/–5.0%
+12 V 4.5 A 9 A 5 A 120 mV ±3.0%
–12 V 0.5 A 1.5 A 1 A 120 mV ±3.0%
+5.1 V 8 A 20 A 10 A 50 mV ±2.0% NFS110-7604PJ
+15 V 4 A 7.5 A 5 A 150 mV ±3.0%
–15 V 0.5 A 1.5 A 1 A 150 mV ±3.0%
–5 V 0.5 A 1.5 A 1 A 50 mV ±3.0%
5.1 V 16 A 22 A 20 A 50 mV ±2.0% NFS110-7605J (7,8)
12 V 7 A 9 A 9 A 120 mV ±2.0% NFS110-7612J (7,8)
15 V 5 A 7.3 A 7.3 A 150 mV ±2.0% NFS110-7615J (7,8)
24 V 3.5 A 4.5 A 4.5 A 240 mV ±2.0% NFS110-7624J (7,8)
TRANSIENT RESPONSE
NFS110-7601PJ +5.1 V (7.5 A to 10 A) 150 mV peak,
1 ms recovery
+12 V (2.5 A to 5 A) 100 mV peak,
0.5 ms recovery
-12 V (0.5 A to 1 A) 100 mV peak,
0.5 ms recovery
-5 V (0.5 A to 1 A) 100 mV peak,
0.5 ms recovery
NFS110-7602PJ +5.1V (7.5 A to 10 A) 150 mV peak,
1 ms recovery
+24 V (1.5 A to 3 A) 300 mV peak,
1 ms recovery
+12 V (2.5 A to 5 A) 100 mV peak,
0.5 ms recovery
-12 V (0.5 A to 1 A) 100 mV peak,
0.5 ms recovery
NFS110-7604PJ +5.1 V (7.5 A to 10 A) 150 mV peak,
1 ms recovery
+15 V (2.5 A to 5 A) 100 mV peak,
0.5 ms recovery
-15 V (0.5 A to 1 A) 100 mV peak,
0.5 ms recovery
-5 V (0.5 A to 1 A) 100 mV peak,
0.5 ms recovery
NFS110-7605J +5.1 V (10 A to 20 A) 250 mV peak,
1 ms recovery
NFS110-7612J +12 V (4.5 A to 9 A) 360 mV peak,
1 ms recovery
NFS110-7615J +15 V (3.65 A to 7.3 A) 450 mV peak,
1 ms recovery
NFS110-7624J +24V (2.25 A to 4.5 A) 720 mV peak,
1 ms recovery
Embedded Power for
Business-Critical Continuity
Rev.02.16.07
NFS110 Series
4 of 4
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co.
©2007 Emerson Electric Co.
Emerson Network Power.
The global leader in enabling
business-critical continuity.
EmersonNetworkPower. com
AC Power
Connectivity
DC Power
Embedded Power
Inbound Power
Integrated Cabinet Solutions
Outside Plant
Precision Cooling
Site Monitoring and Services
Americas
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone: +1 760 930 4600
Facsimile: +1 760 930 0698
Europe (UK)
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
Asia (HK)
16th - 17th Floors, Lu Plaza
2 Wing Yip Street, Kwun Tong
Kowloon, Hong Kong
Telephone: +852 2176 3333
Facsimile: +852 2176 3888
For global contact, visit:
www.powerconversion.com
technicalsupport@powerconversion.com
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Artesyn Embedded Technologies:
NFS110-7601J NFS110-7604J NFS110-7602J NFS110-7915J NFS110-7624J NFS110-7612J NFS110-7924J