Copyright © Murata Manufacturing Co., Ltd. All Rights Reserved 2008
DR-TRC103-868-EV (R) 8/4/16 Page 1 of 6 www.murata.com
Electrical Characteristics
Characteristic Sym Notes Min Typ Max Units
Center Frequency FC2655 MHz
Maximum Insertion Loss, 2624 to 2690 MHz IL 2.3 3.6 dB
Amplitude Ripple, 2624 to 2690 MHz 0.8 2.0 dBP-P
VSWR, 2624 to 2690 MHz 1.9:1 2.5:1
Attenuation Referenced to 0 dB:
DC to 2100 MHz 25 31
dB
2100 to 2515 MHz 27 34
2770 to 4000 MHz 30 37
4000 to 5000 MHz 15 22
Source Impedance ZS50
Load Impedance ZL50
ESD Voltage (machine model) 50 V
Case Style SM3030-6 3.0 x 3.0 mm Nominal Footprint
Lid Symbolization (Y=year, WW=week, S=shift) dot=pin 1 indicator A05, YWWS
Standard Reel Quantity Reel Size 7 Inch 500 Pieces/Reel
Reel Size 13 Inch 3000 Pieces/Reel
SM3030-6
• Low-loss RF SAW Filter
• Surface-mount 3.0 x 3.0 x 1.3 mm Package
• Complies with Directive 2002/95/EC (RoHS)
Absolute Maximum Ratings
Rating Value Units
Input Power Level 10 dBm
DC Voltage on any Non-ground Terminal 3 V
Operating Temperature Range -40 to +85 °C
Storage Temperature Range in Tape and Reel -40 to +85 °C
Solder Reflow Temperature, 10 seconds, 5 cycles maximum 260 °C
2655 MHz
SAW Filter
DR-TRC103-868-EV
1. Unless noted otherwise, all specifications apply over the operating temperature range with filter soldered to the specified demonstration board with impedance
matching to 50 and measured with 50 network analyzer.
2. Unless noted otherwise, all frequency specifications are referenced to the nominal center frequency, fc.
3. Rejection is measured as attenuation below the minimum IL point in the passband. Rejection in final user application is dependent on PCB layout and external
impedance matching design. See Application Note No. 42 for details.
4. "LRIP" or "L" after the part number indicates "low rate initial production" and "ENG" or "E" indicates "engineering prototypes."
5. The design, manufacturing process, and specifications of this filter are subject to change.
6. Either Port 1 or Port 2 may be used for either input or output in the design. However, impedances and impedance matching may vary between Port 1 and Port
2, so that the filter must always be installed in one direction per the circuit design.
7. US and international patents may apply.
8. Murata, stylized Murata logo, and Murata N.A., Inc. are registered trademarks of Murata Manufacturing Co., Ltd.
Pb
CAUTION: Electrostatic Sensitive Device. Observe precautions for handling.
NOTES: