3PCB Relay G5S
Characteristics Table -- continued from previous page
Life expectancy (See Note 5.) Mechanical 5,000,000 operations (18,000 operations per hour)
Electrical 200,000 operations: 1 A (NO)/1 A (NC) at 277-VAC resistive load
3 A (NO)/3 A (NC) at 125-VAC resistive load
100,000 operations: 0.8 A (NO)/0.8 A (NC) at 250 VAC, cosφ=0.9
5 A (NO)/3 A (NC) at 30-VDC resistive load
50,000 operations: 2 A (NO)/2 A (NC) at 277-VAC resistive load
5 A (NO)/3 A (NC) at 125-VAC resistive load
Switching
frequency 1,800 operations per hour
Ambient temperature Operating &
storage -- 4 0 °Cto70°C(--40°F to 158°F) with no icing or condensation
-- 4 0 °Cto85°C (class B) (--40°F to 185°F)
Ambient humidity Operating &
storage 35% to 85%
Weight Approx. 8.0 g
Note: 1. The data shown above are initial values.
2. The contact resistance is possible with 1 A applied at 5 VDC using a fall-of-potential method.
3. The operating time is possible with the rated voltage imposed with no contact bounce at an ambient temperature of 23°C.
4. The insulation resistance is possible between coil and contacts and between contacts of the same polarity at 500 VDC.
5. The electrical life data items shown are possible at 23°C.
JAPPROVED STANDARDS
UL508 (File No. E41515)
CSA C22.2 (No. 14) (File No. LR31928)
Model Coil ratings Contact ratings Number of test operations
G5S-1 (-CB)
G5S-1A (-CB) 5--48 VDC 0.5 A, 250 VAC (resistive)
2 A, 120 VAC (resistive)
2A,30VDC(resistive)
5 A, 125 VAC (resistive)
1/10 HP, 125 VAC
5 A, 277 VAC (resistive)
1/6 HP, 277 VAC
0.3 A, 110 VDC (resistive)
5A,30VDC(resistive)
6,000
TÜV (IEC 255, VDE0435 File No. R9650783)
Electrical life tests are performed at 70°C.
Model Coil ratings Contact ratings Number of test operations
G5S-1 (-CB)
G5S-1A (-CB) 5,6,9,12,18,20,24,48 1.5 A, 277 VAC (resistive)
1 A, 250 VAC (resistive)
2A,30VDC(resistive)
30,000
100,000
30,000
1 A, 250 VAC, cosφ=0.8
0.5 A, 250 VAC, cosφ=0.4
1 A, 250 VAC, cosφ=0.8 (NO only)
1 A, 250 VAC, cosφ=0.8 (NC only)
100,000
30,000
200,000
200,000
Note: Pollution Degree 2, Overvoltage Category II, Material Group III