3May 09, 2001
SAW Components B3552
418,00 MHzLow-loss Filter
Data Sheet
Characteristics
Reference temperature:
T
A= 25 ˚C
Terminating source impedance:
Z
S= 50 Ωand matching network
Terminating load impedance:
Z
L= 50 Ωand matching network
1)Temperature dependence of
f
C
:
f
C
(
T
A) =
f
C
(
T
0
) (1 +
TC
f(
T
A –
T
0
)2)
2) Impedance for passband matching bases on an ideal, perfect matching of the SAW filter to
source- and to load impedance (here 50 Ohm). After the SAW filter is removed and input imped-
ance into the input matching / output matching network is calculated.
The conjugate complex value of these characteristic impedances are the input and output imped-
ances for flat passband. For more details, we refer to EPCOS application note #4.
min. typ. max.
Center frequency
f
C
— 418,04 — MHz
(center frequency between 3 dB points)
Minimum insertion attenuation αmin
417,88 ... 418,20 MHz — 2,0 3,5 dB
Pass band (relative to αmin)
417,85 ... 418,23 MHz — 1,0 2,0 dB
417,83 ... 418,25 MHz — 1,0 3,0 dB
417,78 ... 418,30 MHz — 1,5 6,0 dB
Relative attenuation (relative to αmin)αrel
10,00 ... 400,00 MHz 45 50 — dB
400,00 ... 413,00 MHz 35 40 — dB
413,00 ... 417,00 MHz 15 20 — dB
419,00 ... 426,00 MHz 10 15 — dB
426,00 ... 435,00 MHz 35 40 — dB
435,00 ...1000,00 MHz 45 50 — dB
Impedance for pass band matching 2)
Input:
Z
IN =
R
IN ||
C
IN — 260 | |3,20 — Ω || pF
Output:
Z
OUT =
R
OUT ||
C
OUT —260 | |3,20 —Ω || pF
Temperature coefficient of frequency 1)
TC
f— –0,03 — ppm/K2
Frequency inversion point
T
0
5—35°C