MODEL YAW512 YAW515
MAX OUTPUT WATTAGE[W] 5.28 5.10
DC OUTPUT
*1
t12V 0.22A or +24V 0.22A t15V 0.17A or +30V 0.17A
SPECIFICATIONS
MODEL YAW512 YAW515
INPUT
VOLTAGE[V] AC85 - 264 1for DC110 - 370
CURRENT[A]
ACIN 200V
0.07typ (Io=100%)
FREQUENCY[Hz] 47 - 440 or DC
EFFICIENCY[%]
ACIN 100V
67typ (Io=100%)
INRUSH CURRENT[A]
ACIN 100V
20typ (Io=100%)
ACIN 200V
40typ (Io=100%)
OUTPUT
VOLTAGE[V] t12 (+24)t15 (+30)
CURRENT[A] 0.22 0.17
LINE REGULATION[mV] 60max 75max
LOAD REGULATION[mV] 600max 750max
RIPPLE[mVp-p]
*2
120max 120max
RIPPLE NOISE[mVp-p]
*2
150max 150max
TEMPERATURE REGULATION[mV]
0to+55
C
150max 180max
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
Fixed
OUTPUT VOLTAGE SETTING[%]
t5max (Rated input/output,Ta=25C)
HOLD-UP TIME[ms] 10typ (ACIN 85V,Io=100%)
PROTECTION
CIRCUIT
OVERCURRENT PROTECTION
Works over 105% of rating and recovers automatically
ISOLATION
INPUT-OUTPUT AC3,000V 1minute,Cutoff current = 15mA,DC500V 50MWmin (At Room Temperature)
INPUT-FG AC2,000V 1minute,Cutoff current = 10mA,DC500V 50MWmin (At Room Temperature)
OUTPUT-FG AC500V 1minute,Cutoff current=100mA,DC500V 50MWmin (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
-10 to +70C,20 - 95%RH (Non condensing)(
Refer to DERATING CURVE), 3,000m (10,000feet)max
STORAGE TEMP.,HUMID.AND ALTITUDE
-20 to +75C,20 - 95%RH (Non condensing), 9,000m (30,000feet)max
VIBRATION 10 - 55Hz,98.0m/s2(10G), 3minutes period,60minutes each along X,Y and Z axis
IMPACT 490.3m/s2(50G), 11ms,once each X,Y and Z axis
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS UL60950-1,EN60950-1,EN50178,CSA C22.2 No.60950-1 Complies with IEC60950-1
CONDUCTED NOISE
Complies with FCC-B,VCCI-B,Additional capacitors required for meeting CISPR22-B,EN55022-B (External Fuse is required)
*1Output pins can be connected in series to make a 24V/30V output.
*2Measured by 20MHz oscilloscope.
*The output specification is at t12V and t15V.
*Parallel operation with other model is not possible.
YAW5
AC-DC Power Supplies PCB Mount type
YA W 5 12 E
Ordering information
1Series name
2Dual output
3Output wattage
4Output voltage
5UL recognized,TuV
approved CSA certified:E
R
12345
YA
YA-6
¡DERATING CURVE
¡RISE TIME (YAW512: +12V )
¡OVERCURRENT CHARACTERISTICS (YAW512 )
¡STATIC CHARACTERISTICS (YAW512 )
100 ms/DIV
YA
YA-7
YAW5
External view
Performance data
MODEL YAW1012 YAW1015
MAX OUTPUT WATTAGE[W] 10.8 10.5
DC OUTPUT
*1
t12V 0.45A or +24V 0.45A t15V 0.35A or +30V 0.35A
SPECIFICATIONS
MODEL YAW1012 YAW1015
INPUT
VOLTAGE[V] AC85 - 264 1for DC110 - 370
CURRENT[A]
ACIN 200V
0.14typ (Io=100%)
FREQUENCY[Hz] 47 - 440 or DC
EFFICIENCY[%]
ACIN 100V
72typ (Io=100%)
INRUSH CURRENT[A]
ACIN 100V
20typ (Io=100%)
ACIN 200V
40typ (Io=100%)
OUTPUT
VOLTAGE[V] t12 (+24)t15 (+30)
CURRENT[A] 0.45 0.35
LINE REGULATION[mV] 60max 75max
LOAD REGULATION[mV] 600max 750max
RIPPLE[mVp-p]
*2
120max 120max
RIPPLE NOISE[mVp-p]
*2
150max 150max
TEMPERATURE REGULATION[mV]
0to+55
C
150max 180max
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
Fixed
OUTPUT VOLTAGE SETTING[%]
t5max (Rated input/output,Ta=25 C)
HOLD-UP TIME[ms] 10typ (ACIN 85V,Io=100%)
PROTECTION
CIRCUIT
OVERCURRENT PROTECTION
Works over 105% of rating and recovers automatically
ISOLATION
INPUT-OUTPUT AC3,000V 1minute,Cutoff current = 15mA,DC500V 50MWmin (At Room Temperature)
INPUT-FG AC2,000V 1minute,Cutoff current = 10mA,DC500V 50MWmin (At Room Temperature)
OUTPUT-FG AC500V 1minute,Cutoff current=100mA,DC500V 50MWmin (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
-10 to +70C,20 - 95%RH (Non condensing)(
Refer to DERATING CURVE), 3,000m (10,000feet)max
STORAGE TEMP.,HUMID.AND ALTITUDE
-20 to +75C,20 - 95%RH (Non condensing), 9,000m (30,000feet)max
VIBRATION 10 - 55Hz,98.0m/s2(10G), 3minutes period,60minutes each along X,Y and Z axis
IMPACT 490.3m/s2(50G), 11ms,once each X,Y and Z axis
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS UL60950-1,EN60950-1,EN50178,CSA C22.2 No.60950-1 Complies with IEC60950-1
CONDUCTED NOISE
Complies with FCC-B,VCCI-B,Additional capacitors required for meeting CISPR22-B,EN55022-B (External Fuse is required)
*1Output pins can be connected in series to make a 24V/30V output.
*2Measured by 20MHz oscilloscope.
*The output specification is at t12V and t15V.
*Parallel operation with other model is not possible.
YAW10
AC-DC Power Supplies PCB Mount type
YA W 10 1 2 E
Ordering information
1Series name
2Dual output
3Output wattage
4Output voltage
5UL recognized,TuV
approved CSA certified:E
R
12345
YA
YA-8
¡DERATING CURVE
¡RISE TIME (YAW1012: +12V )
¡OVERCURRENT CHARACTERISTICS (YAW1012 )
¡STATIC CHARACTERISTICS (YAW1012 )
100 ms/DIV
YA
YA-9
YAW10
External view
Performance data