AC Current Probe Model MN106 (pdf) 10/05 Rev. 03
Technical Assistance (800) 343-1391 www.aemc.com
1
of 4
AC Current Probe
Model MN106
Small, compact and very tough, the
Model MN106 is designed for meas-
urements from 2A to 150AAC. The
“clothes pin” shape makes it ideal for
use in tight areas, such as breaker
panels, controller panels or outlets. It is
an excellent companion to all DMMs.
Model MN106 works as a traditional
current transformer (with a ratio of
1000:1) and provides current outputs
(mA) for use with DMMs, recorders or
instruments with current ranges. The
Model MN106 permits True RMS
measurements when used with a True
RMS instrument.
Features
Small, compact and very tough
AC probes
“Clothes pin” shape makes them
ideal for use in tight areas, such
as breaker panels, controller
panels, or outlets
Measurements from 2A to 150AAC
Excellent companion to all DMMs.
Permits very low AC current
measurements
Applications
Electrical utility
HVAC
Industrial maintenance
Laboratory
Plant maintenance
AC Current Probe Model MN106 (pdf) 10/05 Rev. 03
Technical Assistance (800) 343-1391 www.aemc.com
2
of 4
Specifications
MODELS MN106
ELECTRICAL
Nominal Range 150A
Measurement Range 2 to 170A
Transformation Ratio 1000:1
Output Signal 1mAAC/AAC
(150mA @ 150A)
Accuracy (150A Range)
45 to 65Hz ±2.5% of Reading ± 0.15A
65 to 1000Hz ±4.5% of Reading ± 0.15A
Phase Shift (150A Range)
2 to 120A/ 10°
50 to 6Hz
Overload 170A continuous
Frequency Range
Load Impedance 5Ωmax noninductive
Working/Common
Mode Voltage 250V
Output Termination 5 ft Lead
MECHANICAL
Operating Temperature 14° to 122°F
(-10° to 50°C)
Storage Temperature -40° to 176°F (-40° to 80°C)
Operating Relative
Humidity 10 to 35°C 85% RH (without roll-off above 35°C)
Jaw Opening 0.78" (20mm)
Maximum Conductor Size 0.47"Ø max (12mm)
Dimensions 1.26 x 4.53 x 0.87" (32 x 115 x 22mm)
Weight 5.6 oz (160g)
Polycarbonate Material Handles 10% fiberglass charged polycarbonate UL94 VO
SAFETY
Electrical 250V working voltage, 250V max common mode between
output and ground, 3kV 50/60Hz dielectric for 1mm
Note: Reference conditions:
23°C ±3K, 20 to 70%RH, external magnetic field <40A/m, no DC component, no external current carrying conductor, test sample
centered, load impedance 1MΩ.
AC Current Probe Model MN106 (pdf) 10/05 Rev. 03
Technical Assistance (800) 343-1391 www.aemc.com
3
of 4
ORDERING INFORMATION CATALOG NO.
AC Current Probe Model MN106 (Lead – 1mA/A 150A max) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cat. #1031.17
Includes a user manual
Accessories (Optional)
Banana plug adaptor (to nonrecessed plug) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cat. #1017.45
0.87"
(22 mm)
1.26"
(32 mm)
4.53"
(115 mm)
Ø=0.47" max.
(12 mm)
Leads:
Double/reinforced
5 ft (1.5m) lead
with safety 4mm
banana plug
AC Current Probe Model MN106 (pdf) 10/05 Rev. 03
Technical Assistance (800) 343-1391 www.aemc.com
4
of 4
Contact Us
United States and Canada:
Chauvin Arnoux®, Inc.
d.b.a. AEMC®Instruments
200 Foxborough Blvd.
Foxborough, MA 02035 USA
(508) 698-2115 • Fax (508) 698-2118
www.aemc.com
Customer Support – for placing an order, obtaining price and delivery:
customerservice@aemc.com
Sales Department – for general sales information:
sales@aemc.com
Repair and Calibration Service – for information on repair and calibration, obtaining a user manual:
repair@aemc.com
Technical and Product Application Support – for technical and application support:
techinfo@aemc.com
Webmaster – for information regarding www.aemc.com:
webmaster@aemc.com
South America, Central America, Mexico, Caribbean, Australia and New Zealand:
Chauvin Arnoux®, Inc.
d.b.a. AEMC®Instruments
15 Faraday Drive
Dover, NH 03820 USA
(978) 526-7667 • Fax (978) 526-7605
export@aemc.com
www.aemc.com
All other countries:
Chauvin Arnoux SCA
190, rue Championnet
75876 Paris Cedex 18, France
33 1 44 85 45 28 • Fax 33 1 46 27 73 89
info@chauvin-arnoux.com