Protistor DCProtistor fuses DC fuses DC Ferrule Fuses 36x250 gR 2000V DC gRB from 0.8 to 40 A Dimensions 255 43 20 o12 CC 209P ... o 36 Weight 667 g Trip force: 15 N at 20 mm 250 CC 2000 ... o 36 Weight 610 g Main Characteristics Size Current rating IN( A ) 0.8 1 1.5 2 3.15 4 5 6 8 10 12 36x250 16 20 25 32 40 10 12 20 25 32 40 Breaking Capacity @ 2000 V DC 30 kA L/R = 20 ms Watts loss 0.8 IN IN (W) (W) 1 1.1 1.8 2 2.8 4 5 5.3 6 7 7.6 10.5 10 12 15.2 19.6 7.0 7.6 10 12 15.2 19.6 1.8 2 3 3.3 5 7 8.8 9 10 12 13 18 17.5 21 26 33.6 12 13 17.5 21 26 33.6 Designation Reference Number Catalog Number CC 2000 CP gRB 36x250/0.8 CC 2000 CP gRB 36x250/1 CC 2000 CP gRB 36x250/1.5 CC 2000 CP gRB 36x250/2 CC 2000 CP gRB 36x250/3.15 CC 2000 CP gRB 36x250/4 CC 2000 CP gRB 36x250/5 CC 2000 CP gRB 36x250/6 CC 2000 CP gRB 36x250/8 CC 2000 CP gRB 36x250/10 CC 2000 CP gRB 36x250/12 CC 2000 CP gRB 36x250/16 CC 2000 CP gRB 36x250/20 CC 2000 CP gRB 36x250/25 CC 2000 CP gRB 36x250/32 CC 2000 CP gRB 36x250/40 CC 209P CP gRB 36x250/10 CC 209P CP gRB 36x250/12 CC 209P CP gRB 36x250/20 CC 209P CP gRB 36x250/25 CC 209P CP gRB 36x250/32 CC 209P CP gRB 36x250/40 P 221135 R 093096 S 093097 T 093098 V 093099 N 084951 Q 221136 S 084955 V 090339 H 093157 W 093100 X 093101 H 086257 Y 081441 X 081440 W 081439 L 084949 M 098497 M 084950 R 087461 L 081131 W 087373 FD36GB200V0,8 FD36GB200V1 FD36GB200V1,5 FD36GB200V2 FD36GB200V3,15 FD36GB200V4 FD36GB200V5 FD36GB200V6 FD36GB200V8 FD36GB200V10 FD36GB200V12 FD36GB200V16 FD36GB200V20 FD36GB200V25 FD36GB200V32 FD36GB200V40 FD36GB200V10K FD36GB200V12K FD36GB200V20K FD36GB200V25K FD36GB200V32K FD36GB200V40K Minimum trip indicator operating voltage: 90 V See Fuse Blocks, Fuse Holders and Fuse clips Pack: 1 piece SCDC16 12/04 Protistor DC fuses Protistor DC fuses DC Ferrule Fuses 36x250 gR 2000V DC gRB from 0.8 to 40 A Electrical characteristics DC applications data Peak arc voltage vs. working voltage L/R (ms) Um(V) 1 4000 2 3000 U (V) 2000 1000 1500 1600 U (V) 500 2400 2300 2200 2100 2000 1900 1800 1700 1600 1500 2000 1400 90 80 70 60 50 40 30 20 10 0 1 : L/R = 45 ms 2 : L/R = 15 ms Above: Curve indicates the maximum permissible value of time constant L/R as a function of DC working voltage Above: Curves indicate for various time constants L/R the peak arc voltage which may appear across fuse terminals, vs. DC working voltage Max. AC voltage (50/60 Hz): 3000 V with breaking capacity of 50 kA 10 2 40 25 a= 130 A2=0.6 B1= 1.25 B2= 0.6 Cf3= 0.8 10 3 32 20 10 16 12 8 5 6 3.15 10 4 1.5 0.8 1 2 t (s) 4 Time vs. current characteristics a= 130 A2=0.6 B1= 1.25 B2= 0.6 Cf3= 0.8 a= 130 A2=0.6 B1= 1.25 B2= 0.6 Cf3= 0.8 10 1 10 -1 10 -2 10 -3 10 -4 1 10 10 2 10 3 1 10 2 10 Above: These curves indicate, for each rated current, pre-arcing time vs. R.M.S. pre-arcing current. 12/04 SCDC17 10 3 1 10 10% tolerance for mean pre-arcing current 10 2 10 3 I (A)