Technical Support: (888) 41-ASTEC or (407) 241-2752
Americas: (760) 930-4600 Europe (UK) 44 (1384) 842-211 Asia (HK) 852-2437-9662
110
Special Features
Electrical Specs
rev 08.24.04
145 Watts
LPQ142 Series
Total Power: 110-145 Watts
Input Voltage: 85-264 VAC
120-300 VDC
# of Outputs: Quad
Active power factor correction
IEC EN61000-3-2 compliance
Adjustable outputs on 1, 3 & 4
Remote sense on main output
Single wire current sharing
Power fail and remote inhibit
Built-in EMI filter
Low output ripple
Overvoltage protection
Overload protection
Thermal overload protection
Adjustable floating 4th output
Optional cover (-C suffix)
Optional fan cover (-CF suffix)
Operating temperature: 0° to 50°C ambient
derate each output at 2.5% per degree from
50° to 70°C
Electromagnetic susceptibility: designed to meet
EN61000-4, -2, -3, -4, -5, -6, -8, -11, Level 3
Humidity: Operating; non-condensing
5% to 95%
Vibration: Three orthogonal axes, sweep at
1 oct/min, 5 min. dwell at four major resonances
0.75 G peak 5 Hz to 500 Hz, operational
Storage temperature: -40° to 85°C
Temperature coefficient: ± .04% per °C
MTBF demonstrated: >550,000 hours at full load
and 25°C ambient conditions
Input
Input range 85-264 VAC, 120-300 VDC
Frequency 47-63 Hz
Inrush current 38 A max, cold start @ 25°C
Efficiency 75% typical at full load
EMI filter Meets FCC Class B conducted
CISPR 22 Class B conducted
EN55022 Class B conducted
VDE 0878 PT3 Class B conducted
Power factor 0.99 typical
Safety ground leakage
current 1.0 mA @ 50/60 Hz, 264 VAC input
Output
Maximum power 80 W convection (60 W with cover-C)
145 W with 30 CFM forced air
(100 W with cover-C)
Adjustment range 3.3 - 5.5V on main; -12 - 15V on 3rd
output 3.3 - 25 V on 4th output
Hold-up time 20 ms @145 W load at nominal line
Overload protection Short circuit protection on all outputs.
Case overload protected @ 110-145%
above peak rating
Overvoltage protection Tracks outputs 1, 3 & 4; 10 to 35%
Logic Control
AC Power failure TTL logic signal goes high 100 - 500
msec after V1 output; It goes low at least
4 msec before loss of regulation
Remote inhibit TTL High disables output. Contact
closure causes outputs to "bounce"
Remote sense Compensates for 0.5 V lead drop min.
Will operate without remote sense
connected. Reverse connection
protected.
DC-OK TTL logic signal goes high after main
output is in regulation. It goes low when
there is a loss of regulation
VDE 60950
UL 60950
CB Certificate and report
CSA 60950
CE Mark (LVD)
NEMKO EN 60950/EMKO-TUE
Environmental
Safety
EUROPE
Astec House, Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX, UK
Telephone: 44 (1384) 842-211
Facsimile: 44 (1384) 843-355
AMERICAS
5810 Van Allen Way
Carlsbad, CA 92008
Telephone: 760-930-4600
Facsimile: 760-930-0698
111
www.astecpower.com
Ordering Information
ASIA
Units 2111-2116, Level 21
Tower1, Metroplaza
223, Hing Fong Road
Fwai Fong, New Territories
Hong Kong
Telephone: 852-2437-9662
Facsimile: 852-2402-4426
Model Output Minimum Maximum Load with Maximum Load with Peak Regulation2Ripple
Number Voltage Load Convection Cooling 30 CFM Forced Air Load P/P(PARD)3
LPQ142 5 V (3.3 - 5.5 V) 0 A 12 A 25 A 27 A ±2% 50 mV
12 V 0 A 5 A 6 A 9 A ±3% 120 mV
-12 V (-12 -15 V) 0 A 1 A 1.5 A 2 A ±3% <1%
±3.3-25 V 0.5 A 1.5 A 4.5 A 5 A ±3% <50mV or 1%
1. Peak current lasting <30 seconds with a maximum 10% duty cycle.
2. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3. Peak-to-peak with 20 MHz bandwidth and 10 µF in parallel with a 0.1 µF capacitor at rated line voltage and load ranges.
4. 4th output adjustable 3.3-25 V factory set at 5 V.
5. *Minimum loads are required when output set below 5 Volts
6. Remote inhibit resets OVP latch
Note: -C suffix added to the model number indicates cover option.
-CF suffix added to the model number indicates fan cover option.
(4X) 63.5
1.5
(38.1)
(3X) 19.1
29.1
161.5
171.5
7.0
(177.8)
(2X) 6.4
(2X) 119.6
(2X) 139.7
SK1
N
L
GND
SK6
SK2
MAIN
OUTPUT
4.00
(101.6)
M3
#6-32
#6-32
M3
#6-32 (8 places)
M3 (8 places)
610
15
1 6
+12V OUT
COMM
-12V OUT
COMM
V4+
V4-
-CF option
Connector LPQ142
SK1 PIN 1 GROUND
PIN 3 NEUTRAL
PIN 5 LINE
SK2 PIN 1 +12 V
PIN 2 COMMON
PIN 3 -12 V
PIN 4 COMMON
PIN 5 +5 V to +25 V (Float)
PIN 6 COMMON (Float)
SK4 TB-1 COMMON
TB-2 +5 V
SK6 PIN 1 N/C
PIN 2 DC OK
PIN 3 N/C
PIN 4 V1 SWP
PIN 5 Common
PIN 6 +V1 sense
PIN 7 Sense common
PIN 8 + inhibit
PIN 9 - inhibit
PIN 10 Power fail
Mating Connectors
(SK1) AC Input: Molex 09-50-8051 (USA)
Molex 09-91-0500 (UK)
PINS: 08-58-0111
(SK2) Aux DC Output:
Molex 09-50-8061 (USA)
Molex 09-91-0600 (UK)
PINS: 08-58-0111
(SK6) Control Signals:
Molex 90142-0010 (USA)
PINS: 90119-2110 or
Amp: 87977-3
PINS: 87309-8
(SK4) Main output:
Molex BB-124-08
Astec connector kit #70-841-017, includes al of the above.
Notes:
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ±0.02”.
3. Specifications are for convection rating at factory settings unless
otherwise stated.
4. Mounting screw maximum insertion depth is 0.12”.
5. Warranty: 1 year
6. Weight: 1.63 lb / 0.74 kg
Pin Assignments
LPQ142 Series