TPS2061 , TPS2062 , TPS2063TPS2065 , TPS2066 , TPS2067
SLVS490H – DECEMBER 2003 – REVISED DECEMBER 2008 ........................................................................................................................................
www.ti.com
ELECTRICAL CHARACTERISTICS (continued)over recommended operating junction temperature range, V
I(IN)
= 5.5 V, I
O
= 1 A, V
I( ENx)
= 0 V, or V
I(ENx)
= 5.5 V (unlessotherwise noted)
PARAMETER TEST CONDITIONS
(1)
MIN TYP MAX UNIT
ENABLE INPUT EN OR EN
V
IH
High-level input voltage 2.7 V ≤V
I(IN)
≤5.5 V 2
VV
IL
Low-level input voltage 2.7 V ≤V
I(IN)
≤5.5 V 0.8
I
I
Input current V
I( ENx)
= 0 V or 5.5 V, V
I(ENx)
= 0 V or 5.5 V -0.5 0.5 µA
t
on
Turnon time C
L
= 100 µF, R
L
= 5 Ω3
mst
off
Turnoff time C
L
= 100 µF, R
L
= 5 Ω10
CURRENT LIMIT
T
J
= 25 ° C 1.1 1.5 1.9V
I(IN)
= 5 V, OUT connected to GND,I
OS
Short-circuit output current Adevice enabled into short-circuit
-40 ° C ≤T
J
≤125 ° C 1.1 1.5 2.1
TPS2061, TPS2062,
1.6 2.3 2.7TPS2065, TPS2066I
OC_TRIP
Overcurrent trip threshold V
I(IN)
= 5 V, current ramp ( ≤100 A/s) on OUT ATPS2063, TPS2067 1.6 2.4 3.0
SUPPLY CURRENT (TPS2061, TPS2065)
T
J
= 25 ° C 0.5 1No load on OUT, V
I( ENx)
= 5.5 V,Supply current, low-level output µAor V
I(ENx)
= 0 V
-40 ° C ≤T
J
≤125 ° C 0.5 5
T
J
= 25 ° C 43 60No load on OUT, V
I( ENx)
= 0 V,Supply current, high-level output µAor V
I(ENx)
= 5.5 V
-40 ° C ≤T
J
≤125 ° C 43 70
OUT connected to ground, V
I( EN)
= 5.5 V,Leakage current -40 ° C ≤T
J
≤125 ° C 1 µAor V
I(EN)
= 0 V
Reverse leakage current V
I(OUTx)
= 5.5 V, IN = ground T
J
= 25 ° C 0 µA
SUPPLY CURRENT (TPS2062, TPS2066)
T
J
= 25 ° C 0.5 1No load on OUT, V
I( ENx)
= 5.5 V,Supply current, low-level output µAor V
I(ENx)
= 0 V
-40 ° C ≤T
J
≤125 ° C 0.5 5
T
J
= 25 ° C 50 70No load on OUT, V
I( ENx)
= 0 V,Supply current, high-level output µAor V
I(ENx)
= 5.5 V
-40 ° C ≤T
J
≤125 ° C 50 90
OUT connected to ground, V
I(/ENx)
= 5.5 V,Leakage current -40 ° C ≤T
J
≤125 ° C 1 µAor V
I(ENx)
= 0 V
Reverse leakage current V
I(OUTx)
= 5.5 V, IN = ground T
J
= 25 ° C 0.2 µA
SUPPLY CURRENT (TPS2063, TPS2067)
T
J
= 25 ° C 0.5 2Supply current, low-level output No load on OUT, V
I( ENx)
= 0 V µA-40 ° C ≤T
J
≤125 ° C 0.5 10
T
J
= 25 ° C 65 90Supply current, high-level output No load on OUT, V
I( ENx)
= 5.5 V µA-40 ° C ≤T
J
≤125 ° C 65 110
OUT connected to ground, V
I( ENx)
= 5.5 V,Leakage current -40 ° C ≤T
J
≤125 ° C 1 µAor V
I(ENx)
= 0 V
Reverse leakage current V
I(OUTx)
= 5.5 V, INx = ground T
J
= 25 ° C 0.2 µA
UNDERVOLTAGE LOCKOUT
Low-level input voltage, IN 2 2.5 V
Hysteresis, IN T
J
= 25 ° C 75 mV
OVERCURRENT OC1 and OC2
Output low voltage, V
OL(OCx)
I
O( OCx)
= 5 mA 0.4 V
Off-state current V
O( OCx)
= 5 V or 3.3 V 1 µA
OC deglitch OCx assertion or deassertion 4 8 15 ms
THERMAL SHUTDOWN
(3)
Thermal shutdown threshold 135 ° C
Recovery from thermal shutdown 125 ° C
Hysteresis 10 ° C
(3) The thermal shutdown only reacts under overcurrent conditions.
4Submit Documentation Feedback Copyright © 2003 – 2008, Texas Instruments Incorporated
Product Folder Link(s): TPS2061 TPS2062 TPS2063 TPS2065 TPS2066 TPS2067