2www.irf.com
HFB16HY20CC
A/µs
nC
A
Dynamic Recovery Characteristics ( Per Leg ) @ TJ = 25°C (unless otherwise specified)
A/µs
nC
A
Parameter Min. Typ. Max. Units Test Conditions
trr Reverse Recovery Time — — 30 ns IF = 1.0A,VR = 30V, dif/dt = 200A/µs
trr1 Reverse Recovery Time — 30 — ns TJ = 25°C See Fig.
trr2 — 55— T
J = 125°C 5 IF = 16A
IRRM1 Peak Recovery Current — 4.0 — TJ = 25°C See Fig.
IRRM2 — 7.7 — TJ = 125°C 6 VR = 160V
Qrr1 Reverse Recovery Charge — 66 — TJ = 25°C See Fig.
Qrr2 — 224 — TJ = 125°C 7 dif/dt = 200A/µs
di(rec)M/dt1 Peak Rate of Fall of Recovery Current — 620 — TJ = 25°C See Fig.
di(rec)M/dt2 During tb— 1560 — TJ = 125°C 8
Thermal - Mechanical Characteristics
Parameter Typ. Max. Units
RthJC Junction-to-Case, Single Leg Conducting — 1.49
Wt Weight 4.3 — g
°C/W
See Fig. 2
Parameter Min. Typ. Max. Units Test Conditions
VBR Cathode Anode Breakdown Voltage 200 — — V IR = 100µA
Electrical Characteristics ( Per Leg ) @ TJ = 25°C (unless otherwise specified)
LSSeries Inductance — 6.9 — nH Measured from anode lead to cathode
lead, 6mm ( 0.025 in. ) from package
CTJunction Capacitance, See Fig. 3 — — 72 pF VR = 200V
IRReverse Leakage Current — — 1.0 µA VR = V R Rated
See Fig. 2 — — 100 µA VR = VR Rated, TJ = 125°C
VFForward Voltage — — 1.09 IF = 8.0A, TJ = -55°C
See Fig. 1 — — 0.98 IF = 8.0A, TJ = 25°C
— — 1.15 IF = 16A, TJ = 25°C
— — 1.06 IF = 16A, TJ = 125°C
V