MECHANICAL CHARACTERISTICS
item test condition evaluation standard
soldering heat resistance Stripped wires are immersed in rosin for 5 seconds and then im-
mersed in solder bath of 270 ±5°C for 3 ±0.5 seconds.
90% min. stripped wires should be wet
with solder (except edge of terminal).
PCB wire pull strength The force of 4.9 N is applied for 30 sec. to double lead wire. No damage or cutting off.
vibration test The microphone should be measured after a vibration amplitude
of 1.5 mm with 10 ~ 55 Hz band of vibration frequency to each of
the 3 perpendicular directions for 2 hours.
The sensitivity should be within
±3dB compared with the initial
measurement.
drop test The microphone without packaging is subjected to 3 drops on
each axis from the height of 100 cm onto a 20 mm thick wooden
board.
ENVIRONMENT TEST
item test condition evaluation standard
high temperature test After being placed in a chamber at +80°C for 1 hour.
The microphone will be measured
after being placed at +25°C for 6
hours. The value of the oscillation
frequency should be ±10% compared
to the initial measurements. The SPL
should be within ±3dB compared to
the initial measurements.
low temperature test After being placed in a chamber at -30°C for 1 hour.
humidity test After being placed in a chamber at +40°C and 90 ±5% RH for
240 hours.
temperature cycle test The part will be subjected to 10 cycles. One cycle will consist of:
к
+25к +25к
-30к
1hr 0.5hr 1hr 0.5hr 1hr 0.5hr 1hr
TEST CONDITIONS
standard test conditions a) Temperature: +5 ~ +35°C b) Humidity: 45 ~ 85% c) Pressure: 860 ~ 1060 mbar
judgement test conditions a) Temperature: +25 ±2°C b) Humidity: 60 ~ 70% c) Pressure: 860 ~ 1060 mbar