Coaxial cable connection of Antennas, Sensors, and Communication Trunk Lines
GT11 Series
— Connectors for coaxial cables —
Features
Cost efficient termination
Highly efficient and reliable single motion crimp termination allows high volume production with semi-
automatic equipment.
Lock-release latching system
Shock / vibration resistant electrical connections
Verification of the full contact insertion
77
For Double-Conductor coaxial shielded cable
GT11-2S-5.2C
GT11-2S-6.0C
761-0002-3
761-0028-7
Part Number CL No. Applicable Cable
4.5 to 5.2mm
5.8 to 6.2mm
Item
Outer terminal
Insulator
Material
Brass
PT
Finish
Tin plating
Color: Dark gray
* The suitable terminals might differ depending on the internal structure of the cable.
GT11-1822SCF
GT11-2428SCF 761-0004-9
761-0020-5
Part Number CL No.
Conductor Size (AWG)
Material Finish Packaging
#18 to 22
#24 to 28 Brass Tin plating 8,000 pcs.
per reel
GT11-2P-5.2C
GT11-2P-6.0C
761-0001-0
761-0027-4
Part Number CL No. Applicable Cable
4.5 to 5.2mm
5.8 to 6.2mm
Item
Outer terminal
Insulator
Material
Brass
PT
Finish
Tin plating
Color: Dark gray
* The suitable terminals might differ depending on the internal structure of the cable.
GT11-1822PCF
GT11-2428PCF
761-0003-6
761-0019-6
Part Number CL No.
Conductor Size (AWG)
Material Finish Packaging
#18 to 22
#24 to 28 Brass Tin plating 8,000 pcs.
per reel
F Connectors
Outer terminals
Inner Terminals
M Connectors
Outer terminals
Inner Terminals
78
For Double-Conductor coaxial cable
B
Shown with inserted retainer
Part Number
GT11-2S-HU
CL No. Material Color
761-0005-1 PBT Light gray
Part Number
GT11-2P-HU
CL No. Material Color
761-0006-4 PBT Light gray
B
Fully mated connector assemblies
Part Number
GT11N-2PP-HU
CL No. Material Color
761-0008-0 PBT Light gray
F Connectors
Housing
M Connectors
Housing B
Shown with inserted retainer
B
Shown with inserted retainer
79
Part Number
GT11-2S-HU
CL No. Material Finish Color
PBT
Brass
PBT
Phosphor bronze
----
Tin plating
----
Tin plating
Light gray
----
Dark gray
----
761-0005-1
For outer conductor
For inner conductor
パネル
BRecommended Board Mounting Pattern
B
Recommended
Panel Cut-out
For outer conductor
For inner conductor
パネル
基板
Part Number
GT11X-2/2P-DS
CL No. Material Finish Color
PBT
Brass
PBT
Phosphor bronze
----
Tin plating
----
Tin plating
Light gray
----
Dark gray
----
761-0022-0
Part Number
GT11-2P-DSA
CL No.
761-0038-0
M Connectors
Housing
Housing (2-position Type) B
Fully mated connector
assemblies
BRecommended Board
Mounting Pattern
Housing (Straight Type) B
Recommended Board Mounting Pattern
B
Fully mated connector assemblies
80
Waterproof type For Double-Conductor coaxial cable
Part Number
GT11W-2P-HU
CL No. Material
761-0023-3 PBT
Part Number
GT11W-2S-HU
CL No. Material
761-0024-6 PBT
Part Number
GT11W-6.0R
CL No. Applicable Cable
761-0025-9 PBT
Silicon rubber compound
F Connectors
Housing
B
Fully mated connector assemblies
M Connectors
Housing
Retainer (used with GT11W-2S-HU and GT11W-2P-HU)
81
Waterproof type For Double-Conductor coaxial cable
Part Number
GT11K-2/2S-HU
CL No. Material Color
761-0039-3 PBT Light gray
* Mates only with GT11KN-2/2PP-HU.
Part Number
GT11KN-2/2PP-HU
CL No. Material Color
761-0040-2 PBT Light gray
F Connectors
Housing
B
Shown with inserted retainer
B
Shown with inserted retainer
M Connectors
Housing
82
1Strip the cable.
2Cut the shield and expose the wire.
3Cut back the shield above the sheath and wrap with
conductive tape.
4Strip the wire and form it.
Jig used: Cable-forming strip jig
(Refer to Page 85 for detail.)
5Crimp the wire to the internal terminal.
Jig used: Automatic crimping machine.
(Refer to Page 85 for detail.)
6Insert the internal terminals into the Outer terminals.
7Crimp the Outer terminal.
Jig used: Outside tube caulking jig.
(Refer to Page 91 for detail.)
8Insert the terminal into the housing.
(Please insert until the terminal is stopped by the lance.)
9Mount the retainer to complete the task.
Refer to Page 84 for information
about the retainer mounting
method.
BTermination sequence
Cable
Shield
Wire
Conductor
1mm max.
The shield must be visible.
The joined side of the crimp portion faces upward
(for both male and female).
83
a. Insert so that the terminal
locking tab is inserted
between the top surface
of the terminal and the
housing.
b. Push in while changing
the angle of the retainer
until the front surface
comes to a stop.
c. Press the rear portion of
the retainer and snap it
into the locked position.
d. If locking is not complete,
press the rear portion of
the retainer again while
pulling it backward.
* Check that all locations are locked.
* Check that the bands are housed in all of the receiving areas.
BRetainer Mounting Method
84
BTermination Tools
Item
Capacity
Stroke
Number of strokes
Weight
Motor
Crimping speed
Specification
1.5tons
30mm
200spm (50Hz)
75kg
0.2kW
2000 to 4000 pcs. per day
Remarks
200spm (60Hz)
AC100V
Specifications
User's manuals are available. Please ask your Hirose Electric account representative.
Main Unit Accessory (Electrical Box)
Part Number CM-105
Part Number CT11-CT/AD
* Crimp height setting tables are available for each cable type. Please contact your nearest Hirose Electric account representative.
Different cables will require different crimp height settings.
Part Number CT11-ST/AD
Mounting Dimensions
Weight
Power supply
Air pressure
Task time
Capacity
Approximately 400 W x 500 D x 300 H
Approximately 40 kg
AC100V (50/60Hz)
5-6Kgf/cm
Approximately 14 seconds
Remarks
Approximately 300 W x 250 D x 200 H
Approximately 5 kg
Specifications
Main Unit Accessory (Electrical Box)
Mounting Dimensions
Weight
Power supply
Air pressure
Specification
Approximately 300 W x 400 D x 300 H
Approximately 25 kg
AC100V (50/60Hz)
5-6Kgf/cm
Remarks
Approximately 300 W x 250 D x 200 H
Approximately 5 kg
Specifications
Cable-Forming Strip Jig (for 2-conductor cable)
Automatic Crimping Machine (for 2-conductor and 8-conductor cable)
Cable-Forming Strip Jig (for 2-conductor cable)
85
For 8-Conductor coaxial shielded cable
Part Number CL No.
Conductor Size (AWG)
Material Finish
GT11-1822SCF 761-0004-9 #24 to 28 Phosphor bronze Tin plating
GT11-2428SCF 761-0020-5 #24 to 28 Phosphor bronze Tin plating
Part Number CL No. Material
GT11-8DS-2.8C 761-0014-2 PBT
Part Number CL No. Material Finish
GT11-8DS-5C 761-0015-5 Brass Phosphor bronze
F Connectors
Inner Terminal
Insulator
Outer terminals
86
Part Number CL No. Material Finish
GT11-8DS-SB 761-0016-8 Brass Tin plating
Part Number CL No. Material
GT11-8DS-HU 761-0017-0 PBT
Part Number CL No. Material
GT11-8DS-6R 761-0018-3 PBT
Shield Plate
Housing
Retainer (used with GT11-8DS-HU)
87
Part Number CL No.
Conductor Size (AWG)
Material Finish
GT11-1822PCF 761-0003-6 #18 to 22 Phosphor bronze Tin plating
GT11-2428PCF 761-0019-6 #24 to 28 Phosphor bronze Tin plating
Part Number CL No. Material
GT11-8DP-2.8C 761-0009-2 PBT
Part Number CL No. Material Finish
GT11-8DP-5C 761-0010-1 Brass Phosphor bronze
M Connectors
Inner Terminals
Insulator
Outer terminals
88
Part Number CL No. Material Finish
GT11-8DP-SB 761-0011-4 Brass Phosphor bronze
Part Number CL No. Material
GT11-8DP-HU 761-0012-7 PBT
Part Number CL No. Material
GT11-8DP-6R 761-0013-0 PBT
* Reserved for product expansion
Shield Plate
Housing
Retainer (Used with GT11-8DS-HU)
89
Part Number CL No. Item Material Finish
Housing PBT
Outer Terminal Phosphor bronze Tin plating
GT11-8DP-2.8DS 761-0021-8 Insulator PBT
Terminal Brass Tin plating
Printed Circuit Board Type
Board
B
Recommended Board Mounting Pattern
BFully mated connector assemblies
90
BTermination sequence
1Strip the Cable.
2Cut the shield and expose
the wire.
3Cut back the shield above
the sheath and wrap with
conductive tape.
4Strip the wire.
5Crimp the internal terminals.
6Insert the inner terminals into the insulated case.
7Insert what was made in Step 6into the Outer
terminals.
8Insert the caulking shield cover onto the Outer
terminals.
9Insert what was made in Step 8into the housing.
!0Insert the retainer.
Cable Shield
Wire
Conductive tape
Internal terminals
Inner terminal
Outer terminals
Shield cover
Housing
Retainer Completion
91
Hand Press
Part Number GT11-8S/P-HP
BTermination Tools
User's manuals are available. Please ask your Hirose Electric account representative.
Item Specification Remarks
Capacity 1.5Ton
Stroke 30mm
Number of strokes 200spm (50Hz) 240spm (60Hz)
Weight 75kg
Motor 0.2kW AC100V
Crimping speed 2000 to 4000 pcs. per day
Main Unit Accessory (Electrical Box)
Part Number CM-105
Specifications
Part Number CT11-ST/AD
Part Number CT11-CT/AD
Specifications
Specifications
* Crimp height setting tables are available for each cable type. Please contact your
nearest Hirose Electric account representative.
Different cables will require different crimp height settings.
Main Unit Accessory (Electrical Box)
Cable-Forming Strip Jig (for 2-conductor cable)
Mounting Dimensions
Weight
Power supply
Air pressure
Task time
Capacity
Approximately 400 W x 500 D x 300 H
Approximately 40 kg
AC100V (50/60Hz)
5-6Kgf/cm
Approximately 14 seconds
Remarks
Approximately 300 W x 250 D x 200 H
Approximately 5 kg
Automatic Crimping Machine (for 2-conductor and 8-conductor cable)
Cable-Forming Strip Jig (for 2-conductor cable)
Mounting Dimensions
Weight
Power supply
Air pressure
Specification
Approximately 300 W x 400 D x 300 H
Approximately 25 kg
AC100V (50/60Hz)
5-6Kgf/cm
Remarks
Approximately 300 W x 250 D x 200 H
Approximately 5 kg
Outer terminal Caulking Jig (for 8-conductor cable)
92