Installation Guide S18 Sensors - ac-Voltage Series Self-contained, ac-operated sensors Additional information on this product is immediately available online at www.bannerengineering.com/116160 View or download additional information, including excess gain curves, beam patterns and accessories. For further assistance, contact a Banner Engineering Applications Engineer at (763) 544-3164 or (888) 373-6767. Sensing Mode Opposed Retroreflective Polarized Retroreflective P Range LED Output - 20 m (66') Infrared 950 nm 2m (79") Visible Red 680 nm R LISTED Cabled Emitters Diffuse bn 20-250V ac bu 100 mm (4") 300 mm (12") 25 mm (1") cutoff QD Emitters (4-pin Micro-Style) Fixed Field rd/bk rd/wh No Connection All Other Cabled Models Cabled Models Load S18AW3R DO S18RW3R LO S18AW3L DO S18RW3L LO S18AW3LP DO S18RW3LP LO S18AW3D DO S18RW3D LO S18AW3DL DO S18RW3DL LO S18AW3FF25 DO S18RW3FF25 LO S18AW3FF50 DO S18RW3FF50 LO S18AW3FF100 DO S18RW3FF100 Dimensions 20-250V ac bk LO * Standard 2 m (6.5') cable models are listed. * 9 m (30') cable: add suffix "W/30" (e.g., S183E W/30). * 4-pin Micro-style QD models: add suffix "Q1" (e.g., S183EQ1). A model with a QD connector requires a mating cable. Use polarized models when shiny objects will be sensed. bn bu 50 mm (2") cutoff 100 mm (4") cutoff 20-250V ac rd gn Infrared 880 nm Model* S183E Yellow LED Output Indicator QD Models Yellow LED Output Indicator Green LED Power Indicator All Other QD Models (4-pin Micro-Style) Green LED Power Indicator rd/bk rd/wh rd gn 20-250V ac Load No Connection 85.3 mm* (3.36") 63.2 mm (2.49") *Polarized retro and fixed-field models = 86.3 mm (3.40") ! WARNING . . . 104.1 mm* (4.10") 63.2 mm (2.49") *Polarized retro and fixed-field models = 105.1 mm (4.14") Not To Be Used for Personnel Protection Never use these products as sensing devices for personnel protection. Doing so could lead to serious injury or death. These sensors do NOT include the self-checking redundant circuitry necessary to allow their use in personnel safety applications. A sensor failure or malfunction can cause either an energized or de-energized sensor output condition. Consult your current Banner Safety Products catalog for safety products which meet OSHA, ANSI and IEC standards for personnel protection. Printed in USA 10/04 Jan 2013 P/N 116160 p/n 116160 Rev. A S18 Sensors - ac-Voltage Series Specifications Supply Voltage and Current 20 to 250V ac (50/60 Hz). Average current: 20 mA Peak current: 200 mA at 20V ac, 500 mA at 120V ac, 750 mA at 250V ac Supply Protection Circuitry Protected against transient voltages Output Configuration SPST solid-state ac switch; Three-wire hookup; Choose light operate or dark operate models Light Operate: Output conducts when sensor sees its own (or the emitter's) modulated light Dark Operate: Output conducts when the sensor sees dark Output Rating 300 mA maximum (continuous); Fixed-Field Models: derate 5 mA/C above +50C (+122F) Inrush Capability 1 amp for 20 milliseconds, non-repetitive OFF-state leakage current: < 100 microamps ON-state saturation voltage: 3V at 300 mA ac; 2V at 15 mA ac Output Protection Circuitry Protected against false pulse on power-up Output Response Time Opposed Mode: 16 milliseconds ON, 8 milliseconds OFF Other Models: 16 milliseconds ON and OFF NOTE: 100 millisecond delay on power-up Repeatability Opposed Mode: 2 milliseconds Other Models: 4 milliseconds Repeatability and response are independent of signal strength. Indicators Two LEDs (Green and Yellow) Green ON steady: power to sensor is ON Yellow ON steady: sensor sees light Yellow flashing: excess gain marginal (1 to 1.5x) in light condition Construction PBT polyester housing; polycarbonate (opposed mode) or acrylic lens Environmental Rating Leakproof design rated NEMA 6P, DIN 40050 (IP69K) Connections 2 m (6.5') attached cable, or 4-pin Micro-style quick-disconnect fitting Operating Conditions Temperature: -40 to +70C (-40 to +158F); Maximum relative humidity: 90% at 50C (non-condensing) Vibration and Mechanical Shock All models meet Mil. Std. 202F requirements. Method 201A (Vibration; frequency 10 to 60 Hz, max., double amplitude 0.06" acceleration 10G). Method 213B conditions H&I (Shock: 75G with unit operating; 100G for non-operation) Certifications R LISTED Quick-Disconnect (QD) Cables Style 4-pin Micro-style Straight Model MQAC-406 MQAC-415 MQAC-430 Length 2 m (6.5') 5 m (15') 9 m (30') Dimensions Pin-Out 38 mm max. (1.5") 4-pin Micro-style Right-angle MQAC-406RA MQAC-415RA MQAC-430RA 2 m (6.5') 5 m (15') 9 m (30') Green Wire Red Wire Red/White Wire Red/Black Wire 38 mm max. (1.5") 1/2-20UNF-2B o 15 mm (0.6") Additional information on this product is immediately available online at www.bannerengineering.com/116160 View or download additional information, including excess gain curves, beam patterns and accessories. For further assistance, contact a Banner Engineering Applications Engineer at (763) 544-3164 or (888) 373-6767. Banner Engineering Corp Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS Corp. OR IMPLIED (INCLUDING, WITHOUT ANY defects WARRANTY WARRANTY: Banner Engineering warrants its products toLIMITATION, be free from forOF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), WHETHER UNDER COURSE OF PERFORMANCE, COURSE USAGE. oneAND year. BannerARISING Engineering Corp. will repair or replace, freeOF of DEALING charge,OR anyTRADE product of its This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR manufacture found to be defective at the time it is returned to the factory during the warranty ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING period. not ARISING cover damage or liability for the improper application of FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USEThis THE warranty PRODUCT, does WHETHER IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, Banner products. This warranty is in lieu of any other warranty either expressed or implied. NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. P/N 116160 Banner Engineering Corp., 9714 Tenth Ave. No., Minneapolis, MN USA 55441 * Phone: 763.544.3164 * www.bannerengineering.com * Email: sensors@bannerengineering.com