20 93 201 0501
20 93 201 0502
20 93 201 0503
20 93 201 0504
20 93 201 0505
20 93 201 0506
Identication Partnumber Drawing Dimensionsinmm
GeneraldescriptionAdvantages
Ha-VISRF-ANT-WR24
PanarRFIDantenna
Ha-VISRF-ANT-WR24
•Designedfortheharshestenvironments
•CircularUHFantenna
•Widerangeantenna
•Hightemperatureversionavailable
•Railwayversion(undertraininstallation)available
Thisantennafamilyisdesignedtofulllthetoughest
applicationrequirements.Hightemperature,harsh
industrialenvironmentorevenrailwayapplications
areinthefocusofthisantennafamiliy.
Itisveryrobustindesignandhasawideopening
angelupto70°.Readrangesfrom1to12meters
couldbefullledincombinationwithHARTINGUHF
RFIDreadersandpassiveUHFtransponders.
Ha-VISRF-ANT-WR24-i-EU
(forharshindustrialapplications)
Ha-VISRF-ANT-WR24-r-EU
(forunderthetrainapplications)
Ha-VISRF-ANT-WR24-t-EU
(forhightemperatureapplications
inindustrialorrailwayapplications)
Ha-VISRF-ANT-WR24-i-US
Ha-VISRF-ANT-WR24-r-US
Ha-VISRF-ANT-WR24-t-US
Ha-VISRF-ANT-WR24
Alldatagivenareinlinewiththeactualstateofartandthereforenotbinding.
HARTINGreservestherighttomodifydesignswithoutgivingtherelevantreasons.
HARTING IT Software Development GmbH & Co. KG
MarienwerderStraße2|D-32339Espelkamp
www.HARTING-RFID.com|Auto-ID@HARTING.com 2018-04-16
Technicalcharacteristics
Ha-VISRF-ANT-WR24
Electrical properties
Frequencyrange EU:865–868MHz
US:902–928MHz
Impedance 50Ohm
Polarization Circular(right)
Gain 8dBic(WR24-r,WR24-t)
(EU:868MHz,US:915MHz) 9dBic(WR24-i)
Openingangle 70°(WR24-r,WR24-t)
67°(WR24-i)
Max.power(FCC15.247) 4WEIRP
Connection WR24-i/WR24-t:Nsocket(female)
WR24-r:directcoaxcable(3m)withSMAconnector
Downtilt ≤10°
Mechanical properties
Dimension(WxHxD) 243x240x42mm
Weight 2.4kg(WR24-r)
1.1kg(WR24-t)
Degreeofprotection WR24-i:IP54
WR24-r:IP67/IK08
WR24-t:IP64
Installation Four6.4mmdrillholes(idealforM5/M6hexagonheadscrew)
Operatingtemperature WR24-i:-45°C…+65°C
WR24-r:-40°C…+85°C
WR24-t:-45°C…+150°C
Railway (rolling stock)
Fireprotection EN45545-2(WR24-r,WR24-t)
Shock EN613731B&2(WR24-r,WR24-t)
Vibration EN613731B&2(WR24-r,WR24-t)
Saltmist DINEN50467:2012-10(WR24-r,WR24-t)
DINEN60512-11-6:03test11f(WR24-r,WR24-t)
Ozone
DINEN50467:2012-10,DINISO1431-1:2011methodB(WR24-r,WR24-t)