LM158-N
,
LM258-N
,
LM2904-N
,
LM358-N
www.ti.com
SNOSBT3I –JANUARY 2000–REVISED DECEMBER 2014
6.6 Electrical Characteristics: LM358, LM2904
V+= +5.0 V, See(1), unless otherwise stated LM358 LM2904
PARAMETER TEST CONDITIONS UNIT
MIN TYP MAX MIN TYP MAX
Input Offset Voltage See(2) , TA= 25°C 2 7 2 7 mV
Input Bias Current IIN(+) or IIN(−), TA= 25°C, 45 250 45 250 nA
VCM = 0 V, See(3)
Input Offset Current IIN(+) −IIN(−), VCM = 0 V, TA= 25°C 5 50 5 50 nA
Input Common-Mode V+= 30 V, See(4) V+−1.
0 0 V+−1.5 V
Voltage Range (LM2904, V+= 26 V), TA= 25°C 5
Supply Current Over Full Temperature Range
RL=∞on All Op Amps
V+= 30 V (LM2904 V+= 26 V) 1 2 1 2 mA
V+= 5 V 0.5 1.2 0.5 1.2 mA
Large Signal Voltage V+= 15V, TA= 25°C,
Gain RL≥2 kΩ, (For VO= 1 V to 11 V) 25 100 25 100 V/mV
Common-Mode TA= 25°C, 65 85 50 70 dB
Rejection Ratio VCM = 0 V to V+−1.5 V
Power Supply V+= 5 V to 30 V 65 100 50 100 dB
Rejection Ratio (LM2904, V+= 5 V to 26 V), TA= 25°C
Amplifier-to-Amplifier Coupling f = 1 kHz to 20 kHz, TA= 25°C −120 −120 dB
(Input Referred), See(5)
Output Current Source VIN+= 1 V,
VIN−= 0 V, 20 40 20 40 mA
V+= 15 V,
VO= 2 V, TA= 25°C
Sink VIN−= 1 V, VIN+= 0 V
V+= 15V, TA= 25°C, 10 20 10 20 mA
VO= 2 V
VIN−= 1 V,
VIN+= 0 V 12 50 12 50 μA
TA= 25°C, VO= 200 mV,
V+= 15 V
Short Circuit to Ground TA= 25°C, See(6), V+= 15 V 40 60 40 60 mA
Input Offset Voltage See(2) 9 10 mV
Input Offset Voltage Drift RS= 0 Ω7 7 μV/°C
Input Offset Current IIN(+) −IIN(−)150 45 200 nA
Input Offset Current Drift RS= 0 Ω10 10 pA/°C
Input Bias Current IIN(+) or IIN(−)40 500 40 500 nA
(1) These specifications are limited to –55°C ≤TA≤+125°C for the LM158/LM158A. With the LM258/LM258A, all temperature specifications
are limited to −25°C ≤TA≤85°C, the LM358/LM358A temperature specifications are limited to 0°C ≤TA≤70°C, and the LM2904
specifications are limited to –40°C ≤TA≤85°C.
(2) VO≃1.4 V, RS= 0 Ωwith V+from 5 V to 30 V; and over the full input common-mode range (0 V to V+−1.5 V) at 25°C. For LM2904, V+
from 5 V to 26 V.
(3) The direction of the input current is out of the IC due to the PNP input stage. This current is essentially constant, independent of the
state of the output so no loading change exists on the input lines.
(4) The input common-mode voltage of either input signal voltage should not be allowed to go negative by more than 0.3 V (at 25°C). The
upper end of the common-mode voltage range is V+−1.5 V (at 25°C), but either or both inputs can go to 32 V without damage (26 V for
LM2904), independent of the magnitude of V+.
(5) Due to proximity of external components, insure that coupling is not originating via stray capacitance between these external parts. This
typically can be detected as this type of capacitance increases at higher frequencies.
(6) Short circuits from the output to V+can cause excessive heating and eventual destruction. When considering short circuits to ground,
the maximum output current is approximately 40 mA independent of the magnitude of V+. At values of supply voltage in excess of +15
V, continuous short-circuits can exceed the power dissipation ratings and cause eventual destruction. Destructive dissipation can result
from simultaneous shorts on all amplifiers.
Copyright © 2000–2014, Texas Instruments Incorporated Submit Documentation Feedback 7
Product Folder Links: LM158-N LM258-N LM2904-N LM358-N