rev 08.25.04
Technical Support: (888) 41-ASTEC or (407) 241-2752
Americas: (760) 930-4600 Europe (UK) 44 (1384) 842-211 Asia (HK) 852-2437-9662
152
Special Features
Electrical Specs
1000-6000 Watts
HPS10/12/15 Series
• Integrated OR-ing diode
• Remote Sense on Bulk output
• Overload protection on all outputs
• Active Inrush limiting
• PFC to 0.99 typical EN61000-3-2
• CISPR22, EN55022 Curve B
conducted/radiated EMI
• EN61000 immunity standards
• Optional 48 W fan voltage (12 V or 24 V)
• Standard 5 V at 5 A standby voltage (3.3V option)
• No minimum load
• Overvoltage protection
• Input OK signal and indicator LED
• Inhibit/Enable
• Remote Margin/Voltage Programming
• Optional current monitor
• Optional AC Line discrimination
• Output Good signal and indicator LED
• Temp good signal and indicator LED
• Optional single wire digital temp monitor
• Optional module I2C interface
• Optional Rack µController
•Hot Plug
• N+1 Redundant Standard
• Optional fan fail signal
• Module present signal
• Optional short circut latch
Input
Input voltage 85-264 VAC*
Frequency 47-440 Hz
Inrush current 40 A peak max.
Efficiency 85% typ @ full case load 230 VAC
Power factor 0.99 typical meets EN61000-3-2
Turn-on time AC on 1.5 sec. typical, Inhibit /
Enable 100 ms typical
EMI filter standard CISPR 22 EN55022 Level “B”
Leakage current standard 2 mA max @ 264 VAC @ 60Hz
(per module)
Radiated EMI CISPR 22 EN55022 Level “B”
Holdup time 20 ms minimum
(independent of input VAC)
AC OK >5 ms early warning min. before
outputs lose regulation; Full cycle
ride thru (50 Hz)
Harmonic distortion Meets EN61000-3-2
Isolation Meets EN60950
* see modules table on the next page
Output
Margining ±5% of nominal
Overall reg 1%
Ripple 1% of Vout Pk-Pk limited to 20 MHz
Dynamic response 2% with 25% load step
Recovery time To within 1% in <300 µsec
Overcurrent protection 105-120% of rated output current
Short circuit protection Protected for continuous short
circuit. Recovery is automatic upon
removal of short
Overvoltage protection 105-120% . Recycle AC input voltage
to reset OVP circuit
Reverse voltage
protection 100% of rated output current
Thermal protection Main and Aux disabled when internal
temp exceeds safe operating range.
Remote sense Up to 0.5 V total drop
Single wire parallel Current share to within 10% of total
rated current
DC OK ±5% of nominal
Minimum load Not required
Standby voltage 5 VDC @5A max. present whenever
AC input is applied (3.3 V @ 5A
optional)
Global Inhibit/Enable Logic “0” standard logic “1” optional
Operating temperature: -10°C to +50°C ambient,
derate output @ 2.5% per degree from 50°C to 70°C
Shock/Vibration: Mil-Hdbk 810E
Humidity: 95% non-condensing
Storage temperature: -40°C to +85°C
Temperature coefficient: 0.02% per °C
Cooling: Internal DC fan
MTBF (Calculated): 200 KHrs; 25°C, 200 VAC input,
nominal O/P voltage, full load
Safety:
UL / CSA UL60950 3rd Ed and CSA C22.2 60950
TUV EN60950
CB Certificate and report
CE Mark
Environmental & Safety