ATEX 3D (tD)
Note This instruction is only valid for products according to EN 61241-0:2006 and EN 61241-1:2004
Note the ex-marking on the sensor or on the enclosed adhesive label
Instruction Manual electrical apparatus for hazardous areas
Device category 3D for use in hazardous areas with combustible dust
Directive conformity 94/9/EG
Standard conformity EN 61241-0:2006, EN 61241-1:2004
Protection via housing "tD"
Use is restricted to the following stated conditions
CE symbol
Ex-identification ¬ II 3D Ex tD A22 IP67 T80°C X
The Ex-significant identification is on the enclosed adhesive label
General The apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual.
The maximum surface temperature has been determined in accordance with method A without a dust layer on the equip-
ment.
The data stated in the data sheet are restricted by this operating instruction!
The special conditions must be adhered to!
Installation, Comissioning Laws and/or regulations and standards governing the use or intended usage goal must be observed.
The adhesive label provided must be affixed in the immediate vicinity of the sensor! The surface to which the label is applied
must be clean, flat and free from grease!
The affixed adhesive label must be readable and durable, taking account of the possibility of chemical corrosion!
Maintenance No changes can be made to apparatus, which are operated in hazardous areas.
Repairs to these apparatus are not possible.
Special conditions
Maximum operating current IL The maximum permissible load current must be restricted to the values given in the following list.
High load currents and load short-circuits are not permitted.
Maximum operating voltage UBmax The maximum permissible operating voltage UBmax must be restricted to the values given in the following list. Tolerances
are not permitted.
Maximum permissible ambient tempera-
ture TUmax
dependant of the load current IL and the max. operating voltage UBmax.
Information can be taken from the following list.
at UBmax=30 V, IL=200 mA 45 °C (113 °F)
at UBmax=30 V, IL=100 mA 50 °C (122 °F)
at UBmax=30 V, IL=50 mA 50 °C (122 °F)
Plug connector The plug connector must not be withdrawn under voltage. The proximity switch is identified as follows: "WARNING - DO NOT
SEPARATE WHEN ENERGIZED". With the plug connector disconnected, soiling of the internal area must be prevented.(i.e.
the area that is inaccessible when the connector is inserted)
The plug connection can only be separated using a tool. This is achieved by using the locking protection V1-Clip (Mounting
accessory from Pepperl + Fuchs).
Protection from mechanical danger The sensor must not be exposed to ANY FORM of mechanical danger.
Protection from UV light The sensor and the connection cable must be protected from damaging UV-radiation. This can be achieved when the sensor
is used in internal areas.
Electrostatic charging Electrostatic charges must be avoided on the mechanical housing components. Dangerous electrostatic charges on the
mechanical housing components can be avoided by incorporating these in the equipotential bonding.