Specifications are subject to change without notice (08.02.06) 1
Photoelectrics
Retro-reflective, Polarized
Type EP 5520
The EP 5520 is a family of
inexpensive general purpose
polarized retro-reflective sen-
sors in a flat-pack housing.
The size (W x H x D) is 35 x
55 x 15 cm, made in grey
PC/ABS, is ideal for use
where the space is limited.
Easy mounting with only two
M4 screws. The output is a
4-wire complementary (NO
and NC) output in NPN (cur-
rent sinking) or PNP (current
sourcing).
Type
Housing
Range
Output type
Housing material
Connection type
Product Description Ordering Key
Type Selection
Housing Rated Ordering no. Ordering no. Ordering no. Ordering no.
diameter operating NPN/cable NPN/plug PNP/cable PNP/plug
W x H x D dist. (Sn) Make & break swit. Make & break swit. Make & break swit. Make & break swit.
35 x 55 x 15 2.0 m EP 5520 NPAP EP 5520 NPAP-1 EP 5520 PPAP EP 5520 PPAP-1
Note: Plugs and reflectors to be ordered separately.
Specifications
Rated operating dist. (Sn) Up to 2.0 m.
Reference reflector
type ER4 Ø 84 mm
Sensitivity Adjust. 270° turn poten.meter
Temperature drift 0.5%/°C
Hysteresis (Diff. travel) (H) 3 - 20%
Rated operational volt. (UB)
10 to 30 VDC (ripple included)
Ripple (Urpp)10%
Output current
Continuous (Ie)200 mA
Short-time (I) 200 mA (max. load 100 nF)
No load supply current (IO)40 mA,
Min. operational current (Im) 0.5 mA
OFF-state current (Ir)100 μA
Voltage drop (Ud)2.5 V
Protection
Reverse polarity, short-circuit,
transients
Transient voltage 1 kV/0,5 J
Light source GaAlAs LED, 660 nm
Light type Red, modulated, synchronized
Sensing angle ±2°
Ambient light Max. 10,000 lux
Operating frequency (f) 250 Hz, light/dark ratio 1:2
Response time
OFF-ON (tON)1 ms
ON-OFF (tOFF)3ms
Range: 2.0 m
Adjustable sensitivity
Modulated, red light, polarized
Supply voltage: 10 to 30 VDC
Output: DC 200 mA, NPN or PNP
Make and break switching functions, LED indication
Photoelectric, inductive and capacitive flat pack
series in PC/ABS housing, IP67
Improved immunity to reflective surfaces
Cable and M12 plug versions
Power ON delay (tV) Typ. 100 ms
Indication
Function
Dark and light
(complementary) switch.
Output ON LED, yellow
Environment
Overvoltage category
III (IEC 60664/60664A; 60947-1)
Pollution degree 3 (IEC 60664/60664A; 60947-1)
Degree of protection IP 67 (IEC 60529; 60947-1)
Temperature
Operating
-20° to +60°C (-4° to +140°F)
Storage
-30° to +70°C (-22° to +158°F)
Vibration 10 to 150 Hz, 0.5 mm/7.5 g
(IEC 60068-2-6)
Shock 2 x 1 m & 100 x 0.5 m
(IEC 60068-2-32)
Dielectric voltage 600 V (IEC 60364-4-41)
Housing material
Grey polycarbonate/ABS blend
Red front PMMA
Connection
Cable Grey, 2 m, 4 x 0.34 mm2,
oilproof PVC
Plug M12 x 1
Cable for plug CON.1A-.. serie
Weight 125 g cable version
40 g plug version
CE-marking Yes
EP 55 20 NPA P-1
2Specifications are subject to change without notice (08.02.06)
9.5
Ø3
35
55
4.5 7
24.5
4.5 3.5 37
57.5
15
Ø7.5
18
Ø6.8
Ø5.2
Ø16.2
LED
Potentiometer
4.6
M12x1 plug
57.5
15
12
Ø16.2
9.5
Ø3
35
55
4.5 7
4.5 3.5 37
24.5
LED
Potentiometer
4.6
EP 5520
Dimensions
EP 5520 .PAP EP 5520 .PAP-1
Operation Diagram
Object present, light beam interrupted
Output ON: Break switching (NC) WH(2)
Make switching (NO) BK(4)
Power supply
Tv
Tv
Wiring Diagrams
NPN
PNP
3 BU
2 WH
4 BK
1 BN
1 BN
2 WH
4 BK
3 BU
Y
X
Sensor
ER4
Reflector
-20.0
-10.0
0.0
10.0
20.0
0.0 0.5 1.0 1.5 2.0 2.5 3.0
Distance (m)
(mm)
(feet)
(inch)
1.6 3.3 4.9 6.6 10
-0.8
-0.4
0
0.4
0.8
8.2
Detection Diagram
Specifications are subject to change without notice (08.02.06) 3
Accessories Delivery Contents
Photoelectric switch: EP5520
Screw driver
Packaging: Corrugated cardboard
Reflectors: ER series
Connector type CON.1A-.. serie
For further information refer to “Accessories”.
EP 5520
Installation Hints
Relief of cable strain Protection of the sensing face Switch mounted on mobile carrierTo avoid interference from inductive voltage/
current peaks, separate the prox. switch pow-
er cables from any other power cables, e.g.
motor, contactor or solenoid cables Incorrect
Correct
The cable should not be pulled A proximity switch should not serve as
mechanical stop
Any repetitive flexing of the
cable should be avoided