Data sheet PROeco PRO ECO 960W 24V 40A Weidmuller Interface GmbH & Co. KG Klingenbergstrae 26 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com You are looking for a reliable power supply with basic functions. With PROeco we can offer you low-cost switch-mode power supply units with high efficiency and system capability. Let's connect. In the series production of machines, in particular, switchmode power supply units with above-average performance values can deliver genuine competitive advantages. The low-cost PROeco series offers all the basic functions and delivers impressively high performance and flexibility. Our PROeco switch-mode power supply units feature a compact design, high efficiency and are extremely easy to maintain. Thanks to temperature protection, short-circuit and overload resistance they can be universally used in all applications. Wide-ranging safety functions and compatibility with our diode and capacitance modules, together with UPS components for setting up a redundant power supply, characterise solutions with PROeco. General ordering data Type Order No. Version GTIN (EAN) Qty. PRO ECO 960W 24V 40A 1469520000 Power supply, switch-mode power supply unit, 24 V 4050118275704 1 pc(s). Creation date November 8, 2020 4:00:10 AM CET Catalogue status 23.10.2020 / We reserve the right to make technical changes. 1 Data sheet PROeco PRO ECO 960W 24V 40A Weidmuller Interface GmbH & Co. KG Klingenbergstrae 26 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com Technical data Dimensions and weights Width Height Depth Net weight 160 mm 125 mm 120 mm 3,190 g Width (inches) Height (inches) Depth (inches) 6.299 inch 4.921 inch 4.724 inch 70 C 85 C -25 C...70 C Operating temperature, min. Storage temperature, min. Storage temperature -25 C -40 C -40 C...85 C Lead 7439-92-1 3000 m Temperatures Operating temperature, max. Storage temperature, max. Operating temperature Environmental Product Compliance REACH SVHC Rated data UL Operating altitude Input AC current consumption Connection system DC input voltage range Input frequency Inrush current Recommended back-up fuse 4,6 A @ 230 V AC / 9,9 A @ 110 V AC Screw connection 80...370 V DC (Derating @ 120 V DC) 47...63 Hz max. 5 A 16 A / DI, safety fuse 20 A, Char. B, circuit breaker 16 A, Char. C, circuit breaker AC input voltage range DC current consumption Frequency range AC Input fuse (internal) Rated input voltage Surge protection 85...264 V AC (derating at 100 V AC) 2,9 A @ 370 V DC / 9 A @ 120 V DC 47...63 Hz Yes 100...240 V AC (widerange input) Varistor Output Capacitive load Continous output current @ UNominal Output power Output voltage Parallel connection option Ramp-up time Residual ripple, breaking spikes unrestricted 40 A @ 50 C, 24 A @ 70 C 960 W 22...28 V (adjustable via potentiometer) yes, max. 3 100 ms < 50 mVPP @ 24 V DC, IN Connection system Nominal output current for Unom Output voltage Overload protection Protection against inverse voltage Rated output voltage Screw connection 40 A @ 50 C 24 V Yes Yes 24 V DC 1 % Creation date November 8, 2020 4:00:10 AM CET Catalogue status 23.10.2020 / We reserve the right to make technical changes. 2 Data sheet PROeco PRO ECO 960W 24V 40A Weidmuller Interface GmbH & Co. KG Klingenbergstrae 26 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com Technical data General data AC failure bridging time @ Inom Earth leakage current, max. Indication Max. perm. air humidity (operational) Operating temperature Power loss, idling Protection against over-heating Protection degree > 20 ms @ 230 V AC / > 20 ms @ 115 V AC 3.5 mA Green LED (Uoutput > 21.6VDC), Yellow LED (loutput > 90% IRated typ. ), red LED (overload, overtemperature, short-circuit, Uoutput < 20.4VDC) 5 %...95 % RH -25 C...70 C 8W Yes IP20 Degree of efficiency Housing version MTBF 93% Metal, corrosion resistant > 500,000 h in accordance with IEC 61709 (SN29500) on terminal rail TS 35 > 0.98...230 V AC / > 0.98...115 V AC 85 W Mounting position, installation notice Power factor (approx.) Power loss, nominal load Protection against reverse voltages from the load 30...35 V DC Short-circuit protection Yes EMC / shock / vibration Limiting of mains voltage harmonic currents Vibration resistance IEC 60068-2-6 Shock resistance IEC 60068-2-27 According to EN 61000-3-2 Noise emission in accordance with EN55032 Interference immunity test acc. to 1 g according to EN 50178 15 g In all directions 2 kV 3 kV I, with PE connection Insulation voltage output / earth Pollution severity 0.5 kV 2 For use with electronic equipment Acc. to EN50178 / VDE0160 VDE0100-410 / acc. to DIN57100-410 Class B EN 61000-4-2 (ESD), EN 61000-4-3 (RS), EN 61000-4-4 (burst), EN 61000-4-5 (surge), EN 61000-4-6 (conducted), EN61000-4-8 (Fields), EN61000-4-11 (Dips) Insulation coordination Insulation voltage input / earth Insulation voltage, input/output Protection class Electrical safety (applied standards) Electrical machine equipment Protection against dangerous shock currents Safety extra-low voltage Acc. to EN60204 Acc. to VDE0106-101 SELV according to EN 60950, PELV according to EN 60204 Protective separation / protection against electrical shock Safety transformers for switch-mode power supplies According to EN 61558-2-16 Connection data (input) Conductor cross-section, AWG/kcmil , max. Conductor cross-section, flexible , min. Conductor cross-section, rigid , min. Number of terminals Tightening torque, min. 12 0.5 mm 0.5 mm 3 for L/N/PE 0.5 Nm Conductor cross-section, AWG/kcmil , min. Conductor cross-section, rigid , max. Connection system Tightening torque, max. Wire connection cross section, flexible (input), max. 26 6 mm Screw connection 0.6 Nm 2.5 mm Creation date November 8, 2020 4:00:10 AM CET Catalogue status 23.10.2020 / We reserve the right to make technical changes. 3 Data sheet PROeco PRO ECO 960W 24V 40A Weidmuller Interface GmbH & Co. KG Klingenbergstrae 26 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com Technical data Connection data (output) Conductor cross-section, AWG/kcmil , max. Conductor cross-section, flexible , max. Conductor cross-section, rigid , max. Connection system Tightening torque, max. 8 10 mm 16 mm Screw connection 0.6 Nm Conductor cross-section, AWG/kcmil , min. Conductor cross-section, flexible , min. Conductor cross-section, rigid , min. Number of terminals Tightening torque, min. 22 2.5 mm 0.5 mm 7 (++,---,13,14) 0.5 Nm Signalling Contact load (NO contact) Relay on/off max. 30 V DC / 1 A Output voltage >21.6VDC/ <20.4VDC, overload Floating contact Yes Approvals Institute (cULus) Certificate no. (cULus) E258476 Classifications ETIM 6.0 eClass 9.0 eClass 10.0 EC002540 27-04-07-01 27-04-07-01 ETIM 7.0 eClass 9.1 EC002540 27-04-07-01 Approvals Approvals ROHS Conform Downloads Approval/Certificate/Document of Conformity Engineering Data Engineering Data User Documentation Declaration of Conformity EPLAN, WSCAD STEP Operating instructions Creation date November 8, 2020 4:00:10 AM CET Catalogue status 23.10.2020 / We reserve the right to make technical changes. 4 Data sheet PROeco PRO ECO 960W 24V 40A Weidmuller Interface GmbH & Co. KG Klingenbergstrae 26 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com Drawings Electric symbol Derating curve Derating curve Derating curve Creation date November 8, 2020 4:00:10 AM CET Catalogue status 23.10.2020 / We reserve the right to make technical changes. 5