TM221CE40R Product datasheet Characteristics controller M221 40 IO relay Ethernet Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications Price* : 329.00 GBP Main Range of product Modicon M221 Product or component type Logic controller [Us] rated supply voltage 100...240 V AC Discrete input number 24 discrete input conforming to IEC 61131-2 Type 1 Analogue input number 2 at input range: 0...10 V Discrete output type Relay normally open Discrete output number 16 relay Discrete output voltage 5...125 V DC 5...250 V AC Discrete output current 2A Complementary Discrete I/O number 40 Number of I/O expansion module <= 7 for relay output Supply voltage limits 85...264 V Network frequency 50/60 Hz Inrush current <= 40 A Power consumption in VA <= 70 VA at 100...240 V with max number of I/O expansion module <= 41 VA at 100...240 V without I/O expansion module Power supply output current 0.52 A at 5 V for expansion bus 0.24 A at 24 V for expansion bus Discrete input logic Sink or source (positive/negative) Discrete input voltage 24 V Discrete input voltage type DC Analogue input resolution 10 bits LSB value 10 mV Conversion time 1 ms per channel + 1 controller cycle time for analog input Permitted overload on inputs +/- 30 V DC for analog input with 5 min maximum +/- 13 V DC for analog input permanent Mar 15, 2019 1 Voltage state 1 guaranteed >= 15 V for input Voltage state 0 guaranteed <= 5 V for input Discrete input current 7 mA for discrete input 5 mA for fast input Input impedance 4.9 kOhm for fast input 3.4 kOhm for discrete input 100 kOhm for analog input Response time 10 ms turn-on operation for output 35 s turn-off operation for input; I2...I5 terminal 10 ms turn-off operation for output 5 s turn-on operation for fast input; I0, I1, I6, I7 terminal 35 s turn-on operation for input; other terminals terminal 5 s turn-off operation for fast input; I0, I1, I6, I7 terminal 100 s turn-off operation for input; other terminals terminal Configurable filtering time 0 ms for input 12 ms for input 3 ms for input Output voltage limits 125 V DC 277 V AC Current per output common 7A Absolute accuracy error +/- 1 % of full scale for analog input Electrical durability Inductive AC-15, (cos phi = 0.35) 240 V / 120 VA : 100000 cycles Resistive DC-12, 24 V / 48 W : 100000 cycles Resistive AC-12, 120 V / 240 VA : 100000 cycles Inductive AC-15, (cos phi = 0.35) 240 V / 36 VA : 300000 cycles Resistive AC-12, 120 V / 80 VA : 300000 cycles Inductive (L/R = 7 ms) DC-13, 24 V / 24 W : 100000 cycles Resistive DC-12, 24 V / 16 W : 300000 cycles Inductive (L/R = 7 ms) DC-13, 24 V / 7.2 W : 300000 cycles Inductive AC-14, (cos phi = 0.7) 240 V / 240 VA : 100000 cycles Inductive AC-15, (cos phi = 0.35) 120 V / 60 VA : 100000 cycles Inductive AC-14, (cos phi = 0.7) 240 V / 72 VA : 300000 cycles Inductive AC-15, (cos phi = 0.35) 120 V / 18 VA : 300000 cycles Resistive AC-12, 240 V / 480 VA : 100000 cycles Inductive AC-14, (cos phi = 0.7) 120 V / 120 VA : 100000 cycles Resistive AC-12, 240 V / 160 VA : 300000 cycles Inductive AC-14, (cos phi = 0.7) 120 V / 36 VA : 300000 cycles Switching frequency 20 switching operations/minute with maximum load Mechanical durability >= 20000000 cycles for relay output Minimum load 1 mA at 5 V DC for relay output Protection type Without protection at 5 A Reset time 1s Memory capacity 256 kB for user application and data RAM with 10000 instructions 256 kB for internal variables RAM Data backed up 256 kB built-in flash memory for backup of application and data Data storage equipment 2 GB SD card optional Battery type BR2032 lithium non-rechargeable, battery life: 4 yr Backup time 1 year at 25 C by interruption of power supply Execution time for 1 KInstruction 0.3 ms for event and periodic task Execution time per instruction 0.2 s Boolean Exct time for event task 60 s response time Maximum size of object areas 512 %M memory bits 8000 %MW memory words 512 %KW constant words 255 %TM timers 255 %C counters Realtime clock With Clock drift <= 30 s/month at 25 C Regulation loop Adjustable PID regulator up to 14 simultaneous loops Counting input number 4 fast input (HSC mode) (counting frequency: 100 kHz), counting capacity: 32 bits Counter function A/B Pulse/Direction Single phase 2 Integrated connection type USB port with connector mini B USB 2.0 Ethernet with connector RJ45 Non isolated serial link "serial 1" with connector RJ45 and interface RS232/RS485 Supply Serial serial link supply at 5 V 200 mA Transmission rate 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m - communication protocol: RS485 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m - communication protocol: RS232 480 Mbit/s - communication protocol: USB Communication port protocol USB port : USB protocol - SoMachine-Network Non isolated serial link : Modbus protocol master/slave - RTU/ASCII or SoMachine-Network : Ethernet protocol Port Ethernet 10BASE-T/100BASE-TX 1 port with 100 m copper cable Communication service DHCP client Ethernet/IP adapter Modbus TCP server Modbus TCP client Modbus TCP slave device Local signalling 1 LED green for SD card access (SD) 1 LED red for BAT 1 LED per channel green for I/O state 1 LED green for SL Ethernet network activity green for ACT Ethernet network link yellow for Link (Link Status) 1 LED red for module error (ERR) 1 LED green for PWR 1 LED green for RUN Electrical connection Mini B USB 2.0 connector for a programming terminal Terminal block, 3 terminal(s) for connecting the 24 V DC power supply Connector, 4 terminal(s) for analogue inputs Removable screw terminal block for inputs Removable screw terminal block for outputs Cable distance between devices Shielded cable: 10 m for fast input Unshielded cable: 30 m for output Unshielded cable: 30 m for digital input Unshielded cable: 1 m for analog input Insulation 2300 V AC between output and internal logic Non-insulated between analogue inputs 500 V AC between input and internal logic Non-insulated between analogue input and internal logic 1500 V AC between supply and ground 500 V AC between sensor power supply and ground 500 V AC between input and ground 1500 V AC between output and ground 2300 V AC between supply and internal logic 500 V AC between sensor power supply and internal logic 500 V AC between Ethernet terminal and internal logic 2300 V AC between supply and sensor power supply Marking CE Sensor power supply 24 V DC at 250 mA supplied by the controller Mounting support Top hat type TH35-15 rail conforming to IEC 60715 Top hat type TH35-7.5 rail conforming to IEC 60715 Plate or panel with fixing kit Height 90 mm Depth 70 mm Width 160 mm Product weight 0.456 kg Environment Standards EN/IEC 60664-1 EN/IEC 61131-2 EN/IEC 61010-2-201 Product certifications ABS CSA cULus LR IACS E10 RCM EAC 3 DNV-GL Environmental characteristic Ordinary and hazardous location Resistance to electrostatic discharge 4 kV on contact conforming to EN/IEC 61000-4-2 8 kV in air conforming to EN/IEC 61000-4-2 Resistance to electromagnetic fields 10 V/m ( 80 MHz...1 GHz) conforming to EN/IEC 61000-4-3 3 V/m ( 1.4 GHz...2 GHz) conforming to EN/IEC 61000-4-3 1 V/m ( 2...2.7 GHz) conforming to EN/IEC 61000-4-3 Resistance to magnetic fields 30 A/m 50/60 Hz conforming to EN/IEC 61000-4-8 Resistance to fast transients 2 kV for power lines conforming to EN/IEC 61000-4-4 2 kV for relay output conforming to EN/IEC 61000-4-4 1 kV for Ethernet line conforming to EN/IEC 61000-4-4 1 kV for serial link conforming to EN/IEC 61000-4-4 1 kV for I/O conforming to EN/IEC 61000-4-4 Surge withstand 2 kV for power lines (AC) in common mode conforming to EN/IEC 61000-4-5 2 kV for relay output in common mode conforming to EN/IEC 61000-4-5 1 kV for I/O in common mode conforming to EN/IEC 61000-4-5 1 kV for shielded cable in common mode conforming to EN/IEC 61000-4-5 0.5 kV for power lines (DC) in differential mode conforming to EN/IEC 61000-4-5 1 kV for power lines (AC) in differential mode conforming to EN/IEC 61000-4-5 1 kV for relay output in differential mode conforming to EN/IEC 61000-4-5 0.5 kV for power lines (DC) in common mode conforming to EN/IEC 61000-4-5 Resistance to conducted disturbances 10 Vrms (0.15...80 MHz) conforming to EN/IEC 61000-4-6 3 Vrms (0.1...80 MHz) conforming to Marine specification (LR, ABS, DNV, GL) 10 Vrms (spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz)) conforming to Marine specification (LR, ABS, DNV, GL) Electromagnetic emission Conducted emissions conforming to EN/IEC 55011 power lines (AC), 0.15...0.5 MHz : 79 dBV/m QP/66 dBV/m AV Conducted emissions conforming to EN/IEC 55011 power lines (AC), 0.5...300 MHz : 73 dBV/m QP/60 dBV/m AV Conducted emissions conforming to EN/IEC 55011 power lines, 10...150 kHz : 120...69 dBV/m QP Conducted emissions conforming to EN/IEC 55011 power lines, 1.5...30 MHz : 63 dBV/m QP Radiated emissions conforming to EN/IEC 55011 class A 10 m, 30...230 MHz : 40 dBV/m QP Conducted emissions conforming to EN/IEC 55011 power lines, 150...1500 kHz : 79...63 dBV/m QP Radiated emissions conforming to EN/IEC 55011 class A 10 m, 200...1000 MHz : 47 dBV/m QP Immunity to microbreaks 10 ms Ambient air temperature for operation -10...55 C for horizontal installation -10...35 C for vertical installation Ambient air temperature for storage -25...70 C Relative humidity 10...95 % without condensation in operation 10...95 % without condensation in storage IP degree of protection IP20 with protective cover in place Pollution degree <= 2 Operating altitude 0...2000 m Storage altitude 0...3000 m Vibration resistance 3.5 mm (vibration frequency: 5...8.4 Hz) on symmetrical rail 1 gn (vibration frequency: 8.4...150 Hz) on symmetrical rail 3.5 mm (vibration frequency: 5...8.4 Hz) on panel mounting 1 gn (vibration frequency: 8.4...150 Hz) on panel mounting Shock resistance 98 m/s (test wave duration:11 ms) Offer Sustainability Sustainable offer status Green Premium product RoHS (date code: YYWW) Compliant - since 1415 - Schneider Electric declaration of conformity Schneider Electric declaration of conformity REACh Reference not containing SVHC above the threshold Reference not containing SVHC above the threshold Product environmental profile Available Product end of life instructions Available Product Environmental Profile End of Life Information 4 Product datasheet Dimensions Drawings TM221CE40R Dimensions 5 Product datasheet Mounting and Clearance Mounting on a Rail 6 TM221CE40R Product datasheet Mounting and Clearance TM221CE40R Direct Mounting on a Panel Surface (1) Install a mounting strip Mounting Hole Layout 7 Product datasheet Mounting and Clearance Mounting Correct Mounting Position Acceptable Mounting Position Incorrect Mounting Position 8 TM221CE40R Product datasheet Mounting and Clearance TM221CE40R Clearance 9 Product datasheet Connections and Schema Digital Inputs Wiring Diagram (Positive Logic) (*) Type T fuse Wiring Diagram (Negative Logic) (*) Type T fuse Connection of the Fast Inputs I0, I1, I6, I7 10 TM221CE40R Product datasheet Connections and Schema TM221CE40R Relay Outputs Negative Logic (Sink) (*) (1) (2) B Type T fuse The COM0, COM1, COM2 and COM3 terminals are not connected internally. To improve the life time of the contacts, and to protect from potential inductive load damage, you must connect a free wheeling diode in parallel to ea Sink wiring (negative logic) Positive Logic (Source) (*) (1) (2) A Type T fuse The COM0, COM1, COM2 and COM3 terminals are not connected internally. To improve the life time of the contacts, and to protect from potential inductive load damage, you must connect a free wheeling diode in parallel to ea Source wiring (positive logic) 11 Product datasheet Connections and Schema TM221CE40R Analog Inputs The (-) poles are connected internally. Pin Wire Color 0V Black AN1 Red 0V Black AN0 Red 12 Product datasheet Connections and Schema TM221CE40R Ethernet Connection Pin N Signal 1 TD+ 2 TD- 3 RD+ 4 - 5 - 6 RD- 7 - 8 - 13 Product datasheet Connections and Schema USB Mini-B Connection 14 TM221CE40R TM221CE40R Product datasheet Connections and Schema SL1 Connection SL1 N RS 232 RS 485 1 RxD N.C. 2 TxD N.C. 3 RTS N.C. 4 N.C. D1 5 N.C. D0 6 CTS N.C. 7 N.C*. 5 Vdc 8 Common Common N.C.: not connected * : 5 Vdc delivered by the controller. Do not connect. 15 Product datasheet Performance Curves Derating Curves Embedded Digital Inputs (No Cartridge) X: Y: Ambient temperature Input simultaneous ON ratio Embedded Digital Inputs (with Cartridge) X: Y: 16 Ambient temperature Input simultaneous ON ratio TM221CE40R