RAC
AC/DC Converter
www.recom-power.com REV.: 2/2018 PA-1
E196683
Description
The RAC45-xxG/OF series are low cost, 4”x2” AC/DC power supplies with universal inputs
(90-264VAC) and fully protected and isolated DC outputs in the range of 12V up to 48V. The converters
are offered in open frame (/OF) version. The outputs are trimmable to compensate for cable losses and
are short circuit and overload protected. The converters work over a wide temperature range of -25°C
to +60°C (with derating), are UL60950, EN60950 and CE certified and comply with Class B EMC limits.
The RAC45-G series come with a three year warranty.
45 Watt
4“ x 2“
Open Frame
Features
Regulated
Converter
Universal input 90-264VAC
Efficiency up to 86%
Short circuit and over voltage/current protected
UL/EN60950 certified, CE marked
Conformal coated product RAC45-G/OF
UL60950 certified
CAN/CSA C22.2 N.60950-1-07 certified
EN60950-1 certified
EN55032 compliant
EN55024 compliant
Notes:
Note1: Efficiency is tested at nominal input and full load at +25°C ambient
Model Numbering
Selection Guide
Part Input Output max. Output Efficiency
Number Voltage Range Voltage Current typ. (1)
[VAC] [VDC] [mA] [%]
RAC45-12SG/OF 90-264 12 3700 84
RAC45-24SG/OF 90-264 24 1900 85
RAC45-48SG/OF 90-264 48 1000 86
Ordering Examples:
RAC45-24SG/OF 24Vout Single open frame version
RAC45-12SG/OF 12Vout Single open frame version
Case Style
nom. Output Voltage
Single
RAC45-__ SG/OF
www.recom-power.com REV.: 2/2018 PA-2
AC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin and full load unless otherwise stated)
RAC45-G/OF
Series
BASIC CHARACTERISTICS
Parameter Condition Min. Typ. Max.
Output Power 48W
Input Voltage Range 90VAC 230VAC 264VAC
Input Current 115VAC
230VAC
1A
0.6A
Inrush Current cold start at 25°C 115VAC
230VAC
20A
40A
No load Power Consumption 230VAC 0.5W
Input Frequency Range 47Hz 63Hz
Output Voltage Trimming
12Vout
24Vout
48Vout
11.4VDC
22.8VDC
45.6VDC
13.2VDC
26.4VDC
52.8VDC
Minimum Load 0%
Power Factor 115VAC
230VAC
0.6
0.5
Start-up Time 115VAC
230VAC
2s
0.8s
Rise Time 115VAC
230VAC
10ms
8ms
Hold-up Time 115VAC
230VAC
16ms
80ms
Internal Operating Frequency 65kHz 100kHz
Output Ripple and Noise (2) 20MHz BW 50mVp-p 120mVp-p
Notes:
Note2: Measurements are made with a 1.0µF & 10µF parallel capacitor
Efficiency vs. Load
RAC45-12SG/OF RAC45-24SG/OF
0 10 20 30 40 50 60 70 80 90
100
100
80
60
40
90
70
50
30
20
10
0
Efficiency [%]
Output Load [%]
90VAC
115VAC
230VAC
264VAC
0 10 20 30 40 50 60 70 80 90
100
100
80
60
40
90
70
50
30
20
10
0
Efficiency [%]
Output Load [%]
90VAC
115VAC
230VAC
264VAC
REGULATIONS
Parameter Condition Value
Output Accuracy
±1.0% typ. / ±3.0% max.
Line Regulation ±0.2% typ. / ±1.0% max.
Load Regulation 10%-100% load 0.5% typ. / 3.0% max.
www.recom-power.com REV.: 2/2018 PA-3
AC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin and full load unless otherwise stated)
RAC45-G/OF
Series
PROTECTIONS
Parameter Type Value
Input fuse internal T3.15A / 250V slow blow
Short Circuit Protection (SCP) continuous, auto recovery
Over Voltage Protection (OVP) 115-135% of Vout nominal Latch OFF
Over Voltage Category OVCII
Over Current Protection (OCP)
12VDC
24VDC
48VDC
3.9 - 6.2A
2.0 - 3.2A
1.1 - 1.56A
Hiccup Mode,
auto recovery
Class of Equipment Class I
Isolation Voltage tested for 1 minute
I/P to O/P
I/P to PE
O/P to PE
3kVAC
1.5kVAC
0.5kVDC
Isolation Resistance I/P to O/P 100M min.
Isolation Capacitance 2200pF max.
Insulation Grade reinforced
Leakage Current I/P to O/P
O/P to FG
0.25mA max.
3.5mA max.
Notes:
Note3: Refer to local safety regulations if input over-current protection is also required
ENVIRONMENTAL
Parameter Condition
Value
Operating Temperature Range @ natural convection 0.1m/s full load -25°C to +50°C
refer to derating graph -25°C to +60°C
Temperature Coefficient ±0.05%/K typ.
Operating Altitude (4) 5000m
Operating Humidity non-condensing 20% - 90% RH max.
Pollution Degree PD2
Conformal Coating provided
Shock 20G, 11ms, 3 times for X,Y and Z axis
MTBF according to MIL-HDBK-217F, G.B. +25°C 200 x 103 hours
continued on next page
Notes:
Note4: Recognized by UL for safe operation up to 5000m. High altitude operation may impact the performance and lifetime
Contact RECOM techsupport for advice
www.recom-power.com REV.: 2/2018 PA-4
AC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin and full load unless otherwise stated)
RAC45-G/OF
Series
SAFETY AND CERTIFICATIONS
Certificate Type (Safety) Report / File Number Standard
Information Technology Equipment, General Requirements for Safety E196683 UL60950-1, 2nd Edition, 2014
CSA C22.2 No. 60950-1-07, 2nd Ed. 2014
Information Technology Equipment, General Requirements for Safety (LVD) SA1406027L01001 EN60950-1, 2nd Edition, 2013
EAC Safety of Low Voltage Equipment RU-AT.49.09571 TP TC 004/2011
RoHS2+ RoHS 2011/65/EU + AM2015/863
EMC Compliance Conditions Standard / Criterion
Electromagnetic compatibility of multimedia equipment – Emission Requirements without external filter EN55032:2015, Class B
Information technology equipment - Immunity characteristics - Limits and methods of
measurement EN55024:2010 + A1:2015
ESD Electrostatic discharge immunity test ±8kV Air; ±4kV Contact EN61000-4-2, Criteria A
Radiated, radio-frequency, electromagnetic field immunity test 3V/m EN61000-4-3, Criteria A
Fast Transient and Burst Immunity AC Power Port: ±1.0kV EN61000-4-4, Criteria A
Surge Immunity AC Power
Port:
L-L ±1.0kV
L-PE ±2.0kV
N-PE ±2.0kV
EN61000-4-5, Criteria B
Immunity to conducted disturbances, induced by radio-frequency fields AC Power Port: 3V EN61000-4-6, Criteria A
Power Magnetic Field Immunity 50Hz, 1A/m EN61000-4-8, Criteria A
Voltage Dips and Interruptions Dips: >95% reduction
Interruption: >95%
EN61000-4-11, Criteria A
EN61000-4-11, Criteria C
Limits of Harmonic Current Emissions EN61000-3-2, Criteria A
Limits of Voltage Fluctuations & Flicker EN61000-3-3
-25 10 20 40 60 80
100
80
60
40
90
70
50
30
20
10
0
Output Load [%]
Ambient Temperature [°C]
0 705030
Derating Graph
(@ Chamber and natural convection 0.1m/s)
Operating Altitude [m]
0 1000 2000 3000 4000 5000
6000
100
80
60
40
90
70
50
30
20
10
0
Output Load [%]
+25°C Tamb
+50°C Tamb
Operating Altitude
(limitation E-Cap heitsink)
www.recom-power.com REV.: 2/2018 PA-5
AC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin and full load unless otherwise stated)
RAC45-G/OF
Series
DIMENSION AND PHYSICAL CHARACTERISTICS
Parameter Type Value
Material PCB
FR4 (UL94-V0)
Dimension (LxWxH) 101.6 x 51.0 x 28.0mm
Weight 126g typ.
continued on next page
Dimension Drawing Open Frame (mm)
51.0
21.0
FC 44.3
28.0
2.5
3.5
101.6
FC 95.3
1
1
M3
2
3
3
4
3.15
4.0
4.0
Customer Application
Customer Application
CN1 CN2
Trim
LED
T3.15
PCB thickness=1.6mm
Top View
Side View
Bottom View
Connections
AC Input (CN1)
Pin # Terminal
1 AC/L
3 AC/N
3 Pins (Pin2 removed) with
3.96mm pitch
DC Output (CN2)
Pin # Terminal
1,2 V+
3,4 V-
4 Pins with
3.96mm pitch
FC = fixing centers
Crimp Terminal AWG Range: 18-22AWG
Tolerance: xx.x= ±1.0mm
xx.xx= ±0.5mm
Compatible Connectors
Housing
Landwin 3960S Series
JST VHR
Molex 51144 Series
Crimp Terminal
Landwin 3963T011R
JST SVH-21T-P1.1
Molex 50539
www.recom-power.com REV.: 2/2018 PA-6
AC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin and full load unless otherwise stated)
RAC45-G/OF
Series
PACKAGING INFORMATION
Parameter
Type
Value
Packaging Dimension (LxWxH) cardboard box 174.0 x 125.0 x 266.0mm
Packaging Quantity 10pcs
Storage Temperature Range -40°C to +85°C
Storage Humidity non-condensing 10% - 95% RH max.
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer.
The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or
cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the
unauthorized
use of RECOM products in such safety-critical applications.
APPLICATION and INSTALLATION
upside-down
vertical
horizontal (standard)
DCAC
DC
AC
DC AC
upside-down
vertical
horizontal (standard)
DCAC
DC
AC
DC AC
upside-down
vertical
horizontal (standard)
DCAC
DC
AC
DC AC
Power Stage
LED
LT3.15A
N-V
Vadj.
+V
Output
Filter
Protection
Input
Filter
Outoput
Voltage
Regulation
OVP
Shut-
Down
OCP
Limit
PE
Mounting
Block diagram
If module is mounted vertical or upside-down with natural convection cooling, the power must be derated 10%.