Pluggable type 2 arrester (surge arrester) for 3-phase current supply
networks with N and PE in a common conductor (4-conductor system:
L1, L2, L3, PEN), with remote indication contact. Overall width: 36 mm.
Commercial data
GTIN (EAN)
4 017918 960827
sales group J020
Pack 1 pcs.
Customs tariff 85363030
Catalog page information Page 32 (TT-2011)
Product notes
WEEE/RoHS-compliant since:
05/05/2006
http://
www.download.phoenixcontact.com
Please note that the data given
here has been taken from the
online catalog. For comprehensive
information and data, please refer
to the user documentation. The
General Terms and Conditions of
Use apply to Internet downloads.
Technical data
Standards
Housing material PBT
Inflammability class acc. to UL 94 V0
Color gray
VAL-CP-3C-350 Order No.: 2859547
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2859547
PHOENIX CONTACT Inc., USA Page 2 / 6
http://www.phoenixcon.com Jul 26, 2011
Standards for air and creepage distances DIN VDE 0110-1
IEC 60664-1: 1992-10
IEC 61643-1
Surge voltage category III
Pollution degree 2
Degree of protection IP20
Mounting type DIN rail: 35 mm
Design DIN rail module, two-section, divisible
Number of positions 3
Ambient temperature (operation) -40 °C ... 80 °C
Message: Surge protection fault Optical, remote indicator contact
Direction of action 3L-N/PE
Width 37.25 mm
Height 70.00 mm
Length 98.50 mm
Protective circuit
IEC category II
T2
EN type T2
Nominal voltage UN240 V AC (230/400 V AC ... 240/415 V AC)
415 V AC (L-L)
Arrester rated voltage UC (L-PEN) 350 V AC
UT (TOV-proof) 415 V AC (5 s)
Nominal frequency fN50 Hz
60 Hz
Nominal load current IL40 A (40 A ... 63 A)
63 A (10 mm2)
Ground conductor current IPE ≤ 250 µA (ground conductor current IPE)
Standby power consumption PC≤ 3.5 mW
Power consumption without load Pc ≤ 3.5 mW
Max. discharge surge current Imax (8/20) µs
maximum (L-PEN)
120 kA (all channels)
Nominal discharge surge current In (8/20) µs (L-
PEN)
20 kA (per channel)
60 kA (all channels)
VAL-CP-3C-350 Order No.: 2859547
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2859547
PHOENIX CONTACT Inc., USA Page 3 / 6
http://www.phoenixcon.com Jul 26, 2011
Protection level UP (L-PEN) ≤ 1.4 kV
Residual voltage (L-PEN) ≤ 1.4 kV (at In)
≤ 1.2 kV (at 10 kA)
≤ 1.1 kV (at 5 kA)
≤ 1 kV (at 3 kA)
Clamping voltage SVR (L-PEN) ≤ 0.9 kV
Clamping voltage ringwave (L-PEN) ≤ 1.2 kV (category C3 20 kV/10 kA)
≤ 1.1 kV (category C2 10 kV/5 kA)
≤ 1 kV (category B3/C1 6 kV/3 kA)
Response time (L-N) ≤ 25 ns
Max. required backup fuse with branch wiring 125 A (gL/gG)
Max. required backup fuse with V-type through
wiring
40 A (gL/gG)
Short-circuit resistance IP with max. backup fuse
(effective)
25 kA
Connection, protective circuit
Connection method Screw connection
Connection type IN Biconnect screw terminal block
Connection type OUT Biconnect screw terminal block
Connection method Biconnect terminal block
Screw thread M5
Tightening torque 4.5 Nm
Stripping length 16 mm
Conductor cross section stranded min. 2.5 mm²
Conductor cross section stranded max. 16 mm²
Conductor cross section solid min. 2.5 mm²
Conductor cross section solid max. 25 mm²
Conductor cross section AWG/kcmil min. 12
Conductor cross section AWG/kcmil max 4
Remote indicator contact
Connection name Remote fault indicator contact
Switching function PDT contact
Connection method Pluggable screw connection
Screw thread M2
Tightening torque 0.25 Nm
VAL-CP-3C-350 Order No.: 2859547
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2859547
PHOENIX CONTACT Inc., USA Page 4 / 6
http://www.phoenixcon.com Jul 26, 2011
Stripping length 7 mm
Conductor cross section stranded min. 0.14 mm²
Conductor cross section stranded max. 1.5 mm²
Conductor cross section solid min. 0.14 mm²
Conductor cross section solid max. 1.5 mm²
Conductor cross section AWG/kcmil min. 28
Conductor cross section AWG/kcmil max 16
Maximum operating voltage Umax. AC 250 V AC
Maximum operating voltage Umax DC 125 V DC
Max. operating current Imax 1 A AC (inductive)
1 A AC (ohmic)
30 mA DC (inductive)
200 mA DC (ohmic)
Min. permissible switching capacity 0.12 VA (12 V, 10 mA)
Standards
Standards/regulations IEC 61643-1 1998
DIN EN 61643-11 2002
UL 1449
IEEE C62.1 / C62.34 / C62.45
Certificates / Approvals
Certification CB, CUL, GL, GOST, KEMA, UL
Accessories
Item Designation Description
Bridges
2880684 MPB SET VAL-CP-3S Wiring bridge set, consisting of three flexible bridges 15 cm black,
1 bridge 27 cm blue.
VAL-CP-3C-350 Order No.: 2859547
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2859547
PHOENIX CONTACT Inc., USA Page 5 / 6
http://www.phoenixcon.com Jul 26, 2011
Marking
0811228 X-PEN 0,35 Marker pen without ink cartridge, for manual labeling of markers,
labeling extremely wipe-proof, line thickness 0.35 mm
0809735 ZBF 12:UNBEDRUCKT Zack strip, flat, unprinted, 5-section, divisible, for labeling by the
customer
0803595 ZBFM 5/WH:UNBEDRUCKT Zack marker sheet, flat, unprinted: 120-section, 10 strips à 12
markers, sufficient for 120 terminal blocks, for all terminal blocks,
pitch 5.2 mm, labeling with M-PEN or CMS system, color: white
Diagrams/Drawings
Dimensioned drawing
Circuit diagram
VAL-CP-3C-350 Order No.: 2859547
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2859547
PHOENIX CONTACT Inc., USA Page 6 / 6
http://www.phoenixcon.com Jul 26, 2011
Address
PHOENIX CONTACT Inc., USA
586 Fulling Mill Road
Middletown, PA 17057,USA
Phone (800) 888-7388
Fax (717) 944-1625
http://www.phoenixcon.com
© 2011 Phoenix Contact
Technical modifications reserved;