Frequency Tuning (EFC)
RF Output
Supply Voltage (Vs)
http://www.vectron.com
Vectron International•267 LowellRoad, Hudson, New Hampshire 03051•Tel:+1-88-VECTRON-1
Vectron International GmbH & Co. KG • Landstraße, 74924 Neckarbischofsheim, Germany • Tel: +49 7268 801 100
Parameter Min Typ Max Units Operating temp range
vs. operating temperature range -75 +75 ppb 0 … +60°C
Options5
(Referenced to +25°C) -100 +100 ppb -20 … +70°C
-150 +150 ppb -40 … +85°C
Parameter Min Typ Max Units Condition
Initial tolerance For Fixed Freq.
Settability
vs. supply voltage change
vs. load
vs. aging / day
vs aging / 1 year
vs. aging /10 year
-1.5
-0.3
-25
-25
-3
-300
-3000
+1.5
+0.3
+25
+25
+3
+300
+3000
ppm
ppm
ppb
ppb
ppb
ppb
ppb
Fixed, no adjust option
VS ± 5%
Load ± 5%
after 7 days of operation
Warm-up Time 120 seconds to ± 1ppm of fi nal freq. @+25°C
180 seconds to ± 100ppb of fi nal freq. @+25°C
Parameter Min Typ Max Units Condition
Supply voltage [Standard] 4.75 5 5.25 VDC
Power consumption 2.2 Watts during warm-up
0.7 Watts steady state @ +25°C
1.2 Watts steady state @ -40°C
Parameter Min Typ Max Units Condition
Signal [Standard] HCMOS
Load 15 pF
Signal Level (Vol) 0.1 VDD
Signal Level (Voh) 0.9 VDD
Rise/Fall Time +7 ns (10-90%)
Duty cycle 40 60 % @ (Voh-Vol)/2
Signal [Option] Sinewave
Load 50 Ω
Output Power [Standard]
Output Power [Option]
Harmonics
Spurious
0.0
3.0
+2.0
+5.0
4.0
7.0
-25
-60
dBm
dBm
dBc
dBc
50 Ohm load
50 Ohm load
Parameter Min Typ Max Units Condition
Tuning Range Fixed, No Adjust
Options5
Tuning Range Suffi cient to compensate for 10 years aging EFC (0V to 4V)
Vref 4.0 4.1 4.2 Vdc Source Current 1mA maximum
Frequency stabilities1 [>20 to 40 MHz]