PRODUCTS UNLIMITED
Dimensions are shown for
reference purposes only.
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Catalog 1308242
Issued 3-03
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
Contact Ratings
Features
• Robust 1- and 2-pole contactors.
• Shunt available on 1-pole models.
• Convenient mounting plate.
Coil Data
1-Pole Models 2-Pole Models
Nominal Coil Voltage 24 120 208/240 277 24 120 208/240 277
Maximum Pickup Volts 18 88 177 221 18 88 177 221
Drop-Out Volts Range 6 - 15 20 - 70 40 - 140 50 - 165 6 - 15 20 - 70 40 - 140 50 - 165
Nominal Inrush VA @ 50 Hz 22.5 22.5 22.5 22.5 37 37 37 37
Nominal Inrush VA @ 60 Hz 20 20 20 20 35 35 35 35
Nominal Sealed VA @ 50 Hz 77778888
Nominal Sealed VA @ 60 Hz 5.25 5.25 5.25 5.25 7777
Nominal DC Resistance - Ohms 16.5 420 1850 2650 11 250 1000 1600
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that users also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Full Number Line Locked Resistive Maximum Horsepower
Load of Voltage Rotor Amps Voltage Single
Amps Poles Amps Rating Phase
240/277 120 30 120 2
20 2 480 100 30 240 3
600 80 30
240/277 150 30 120 1
25 1 480 50 30 240 2
600 40 30
240/277 150 35 120 2
25 2 480 125 35 240 3
600 100 35
240/277 150 40 120 1
30 1 480 75 40 240 2
600 50 40
240/277 150 40 120 2
30 2 480 125 40 240 3
600 100 40
240/277 240 50 120 2
40 1 480 200 50 240 3
600 160 50
240/277 240 50 120 2
40 2 480 200 50 240 3
600 160 50
Contact Data @ 25°C
Arrangements: 1 Form X (SPST-NO-DM) with or without shunt and
2 Form X (DPST-NO-DM).
Maximum Ratings: See Contact Ratings Table.
Material: Silver Cadmium Oxide.
Coil Data @ 25°C
Voltage: 24 - 277 VAC, 50/60 Hz. See Coil Data Table below.
Insulation Class: UL Class B (130°C).
Duty Cycle: Continuous.
Environmental Data
Temperature Range: Storage and Operating: -40°C – +65°C.
Flammability: UL 94-HB housing.
Mechanical Data
Contact Termination:
20, 25, 30 FLA Models
Type: #10-32 Screw with quad 0.250” (6.35 mm) quick connects.
Wire Size: 16-8 AWG (Stranding must be split for 8 AWG wire.)
Tightening Torque: 25 in.-lbs.
40 FLA Models
Type: Box Lug with dual 0.250” (6.35 mm) quick connects.
Wire Size: 14-4 Cu/Al AWG
Tightening Torque: 40 in.-lbs.
Coil Termination: Dual 0.250” (6.35 mm) quick connects.
Arc Cover: Optional on 20-30 FLA models, standard on 40 FLA models.
Weight: One Pole Types: 8 oz. (227 g) approximately.
Two Pole Types: 9.6 oz. (273 g) approximately
Model 96 - 3100 series
Definite Purpose Contactor
1- or 2-pole, 20-40 FLA
AC Coil
File E75492
File EN60947-4-1:1991
IEC 947-4-1