Date Revision
SPECIFICATION CONTROL DRAWING
This specification sheet forms a part of the latest issue of Raychem Specifiction 55PC.
H
TITLE
CONDUCTOR - TIN-COATED COPPER INSULATION - RADIATION-CROSSLINKED,
MODIFIED ETFE
UPPER SPEC
LIMIT
WEIGHT
( lbs/1000 ft. )
DIAMETER
( in.)
MAXIMUM
RESISTANCE
AT 20°C
(ohms/1000 ft.) TARGET
VALUE
UPPER SPEC
LIMIT
CONDUCTOR DIAMETER
( in.)
LOWER
SPEC
LIMIT
TARGET
VALUE
CONDUCTOR
STRANDING
(number x AWG)
WIRE
SIZE
(AWG)
CONSTRUCTION DETAILS
UPPER
SPEC
LIMIT
1.38
1.98
2.90
4.38
6.59
8.37
12.88
19.73
31.12
56.8
89.7
145.
227.
278.
343.
450.
TARGET
VALUE
26
24
22
20
18
16
14
12
10
8
6
4
2
1
0
00
19 x 38
19 x 36
19 x 34
19 x 32
19 x 30
19 x 29
19 x 27
37 x 28
37 x 26
133 x 29
133 x 27
133 x 25
665 x 30
817 x 30
1045 x 30
1330 x 30
.0362
.0412
.0472
.0557
.0654
.0730
.0882
.1074
.1328
.203
.251
.322
.397
.438
.483
.545
.0345
.0395
.0455
.0540
.0635
.0710
.0860
.1047
.1290
.196
.242
.311
.383
.424
.466
.525
.0328
.0378
.0438
.0523
.0616
.0690
.0838
.1020
.1252
.188
.233
.300
.370
.410
.449
.505
55PC0211
WIRE, RADIATION-CROSSLINKED, MODIFIED, ETFE-INSULATED,
GENERAL PURPOSE, LIGHT AIRFRAME
41.3
26.2
16.2
9.88
6.23
4.81
3.06
2.02
1.26
.701
.445
.280
.183
.152
.116
.091
1.52
2.13
3.06
4.57
6.90
8.70
13.33
20.30
32.13
59.9
94.7
154.
240.
291.
366.
481.
PART NUMBER
1/
PART NUMBER:
The "*" in the part numbers above shall be replaced by
color code designators.
1/ Example: AWG 22, white: 55PC0211-22-9
AWG 22, white with black stripe: 55PC0211-22-90
LOWER SPEC
LIMIT
FINISHED WIRE
TEMPERATURE RATING: 150°C
Maximum continuous conductor temperature
VOLTAGE RATING: 600 volts (rms) at sea level
COLOR: White preferred
CROSSLINK VERIFICATION: 300 ± 3°C for 1 hour
IDENTIFICATION AND COLOR STRIPING DURABILITY:
125 cycles (250 strokes) (minimum), 500 g weight
INSULATION ELONGATION AND TENSILE STRENGTH:
Total Insulation,
Elongation, 50% (minimum)
Tensile Strength, 5000 lbf/in² (minimum)
INSULATION FLAWS:
Spark Test, 3.0 kV (rms)
Impulse Dielectric Test, 8.0 kV (peak)
INSULATION THICKNESS: .008 in. (nominal) total insulation
SHRINKAGE: 230 ± 3°C for 1 hour, 0.125 in.(maximum) in 12 in.
VOLTAGE WITHSTAND TEST (Post Environmental):
2500 volts (rms)
55PC0211-26-*
55PC0211-24-*
55PC0211-22-*
55PC0211-20-*
55PC0211-18-*
55PC0211-16-*
55PC0211-14-*
55PC0211-12-*
55PC0211-10-*
55PC0211- 8-*
55PC0211- 6-*
55PC0211- 4-*
55PC0211- 2-*
55PC0211- 1-*
55PC0211- 0-*
55PC0211-00-*
WIRE RATINGS AND ADDITIONAL REQUIREMENTS
07-08-04
.0183
.0233
.0293
.0375
.0464
.0527
.0659
.0845
.1070
.163
.205
.260
.330
.370
.415
.462
.0175
.0225
.0285
.0365
.0452
.0514
.0644
.0825
.1050
.158
.198
.250
.320
.360
.395
.440
.0191
.0241
.0301
.0385
.0476
.0538
.0674
.0865
.1090
.169
.212
.268
.340
.380
.425
.475
RR
RR
R
Wire & Cable
501 Oakside Avenue
Redwood City, CA 94063-3800
Phone: 1-800-227-8816
Fax: 1-650-361-6297
1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. OTHER CODES AND SUFFIXES MAY BE
ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER.
DIMENSIONS ARE IN INCHES AND, UNLESS OTHERWISE DESIGNATED, ARE NOMINAL
Page 1 of 1
THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN.
REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID.
Tyco Electronics also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer.
Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice.