LM
LM www.meas-spec.com August 2014
1/4
316L SS Pressure Sensor with PVC Threads
Small Profile
4.5V (typ) High Level Output
Gage, Absolute, Sealed Gage
ASIC Calibrated
Variety of Cable Lengths
DESCRIPTION
The LM incorporates stainless steel and plastic isolation suitable for level sensing in water and other liquids. The
LM uses a patented low cost stainless steel sensor in a PVC plastic fitting. The modular design is adaptable to
an infinite number of plastic port variations. With high performance in a small form factor, the LM Series enables
the miniaturization of high accuracy pressure systems. The standard output is 4.5V with a 5V supply.
FEATURES APPLICATIONS
Threaded Process Fitting
Irrigation
-20ºC to +70ºC Operating Temperature
RV and Marine Holding Tank Level
±1% Accuracy
Water Storage & Recycling Systems
±3.0% Total Error Band
Small Tank Fluid Level
Solid State Reliability
Chillers & Evaporative Coolers
Variety of Cable Lengths
STANDARD RANGES
Range (psi)
Range (Bar)
Gage
Absolute
0 to 1
0 to .07
0 to 2
0 to .20
0 to 5
0 to .35
0 to 15
0 to 1
0 to 30
0 to 2
0 to 50
0 to 5
0 to 100
0 to 7
0 to 150
0 to 10
Note: Intermediate pressure ranges available.
LM
LM www.meas-spec.com August 2014
2/4
PERFORMANCE SPECIFICATIONS
Supply Voltage: 5.0Vdc
Ambient Temperature: 25°C (unless otherwise specified)
PARAMETERS
MIN
TYP
MAX
UNITS
NOTES
Full Scale Output
4.5
V
1
Zero Pressure Output
0.5
V
1, 2
Accuracy (combined linearity, hysteresis, & repeatability)
-1
+1
%Span
3
Total Error Band (includes calibration errors
above & temperature effects over the
compensated range)
-3
+3
%Span
Supply Voltage
4.75
5.00
5.25
V
Insulation Resistance (50Vdc)
50
MΩ
4
Pressure Overload
3X
Rated
5
Pressure Burst
4X
Rated
6
Compensated Temperature
0
40
ºC
Operating Temperature
-20
+70
ºC
Tightening Torque (recommended)
1~2 Turns from Finger Tight
7
Zero Offset Effect @ 1psiG from 90° Changes due to
Installation Orientation
0.6
%Span
8
Media, Pressure Port
Liquids and Gases compatible with PVC, 316/316L ST STL, Buna-N O-Ring
Notes
1. Ratiometric to supply voltage.
2. Measured at vacuum for Absolute (A), ambient for Gage (G) and Sealed Gage (S).
3. Best fit straight line.
4. Minimum from any wire to metal diaphragm.
5. The maximum pressure that can be applied without changing the transducer’s performance or accuracy
6. The maximum pressure that can be applied to a transducer without rupture of either the sensing element or transducer.
7. Over-torquing will damage the PVC fitting and will cause sensor calibration and/or zero offset to shift during installation. Always check
for a zero offset shift after installing.
8. Zero offset effect is inversely ratiometric to pressure range, for 2psiG: 0.3% Span (typ); for 5psiG: 0.12% Span (typ).
Additional Notes
9. Standard gage units are not recommended for vacuum applications.
10. Direct mechanical contact with diaphragm is prohibited. Diaphragm surface must remain free of defects (scratches, punctures, dents,
fingerprints, etc.) for device to operate properly. Caution is advised when handling parts with exposed diaphragms. Use protective cap
whenever devices are not in use.
LM
LM www.meas-spec.com August 2014
3/4
DIMENSIONS
LM
LM www.meas-spec.com August 2014
4/4
ORDERING INFORMATION
LM
3
1
-
00000
F
-
100P
G
Model
Output
Signal
Connection Type
-
00000
Pressure Port
-
Pressure
Range
Pressure
Type
LM
3* = 0.5 4.5V
Ratiometric
X = Special
Dim ‘L’ Cable
Inches [mm]
1 = 12 ± 0.25 [305 ± 6.4]
2 = 24 ± 0.5 [610 ± 12.7]
3 = 48 ± 1.0 [1219 ± 25.4]
4 = 84 ± 1.5 [2134 ± 38.1]
5 = 120 ± 1.5 [3048 ± 38.1]
6 = 180 ± 2.0 [4572 ± 50.8]
7 = 360 ± 2.0 [ 9144 ± 50.8]
-
00000
F = 1/2-14 NPT
X = Special
-
001P**
002P**
005P
015P
030P
050P
100P
150P
.07B**
.20B**
.35B
001B
002B
005B
007B
010B
G = Gage
A = Absolute
S = Sealed Gage
*Note: Ratiometric output span changes with input voltage. (See supply voltage specification)
**Note: 1psi (.07Bar) and 2psi (.20Bar) only available in Gage (G). (See standard rages)
NORTH AMERICA
EUROPE
ASIA
Measurement Specialties
45738 Northport Loop West
Fremont, CA 94538
Tel: 1-800-767-1888
Fax: 1-510-498-1578
Sales: pfg.cs.amer@meas-spec.com
Measurement Specialties
(Europe), Ltd.
26 Rue des Dames
78340 Les Clayes-sous-Bois, France
Tel: +33 (0) 130 79 33 00
Fax: +33 (0) 134 81 03 59
Sales: pfg.cs.emea@meas-spec.com
Measurement Specialties
(China), Ltd.
No. 26 Langshan Road
Shenzhen High-Tech Park (North)
Nanshan District, Shenzhen 518057
China
Tel: +86 755 3330 5088
Fax: +86 755 3330 5099
Sales: pfg.cs.asia@meas-spec.com
The information in this sheet has been carefully reviewed and is believed to be accurate; however, no responsibility is assumed for
inaccuracies. Furthermore, this information does not convey to the purchaser of such devices any license under the patent rights to the
manufacturer. Measurement Specialties, Inc. reserves the right to make changes without further notice to any product herein. Measurement
Specialties, Inc. makes no warranty, representation or guarantee regarding the suitability of its product for any particular purpose, nor does
Measurement Specialties, Inc. assume any liability arising out of the application or use of any product or circuit and specifically disclaims
any and all liability, including without limitation consequential or incidental damages. Typical parameters can and do vary in different
applications. All operating parameters must be validated for each customer application by customer’s technical experts. Measurement
Specialties, Inc. does not convey any license under its patent rights nor the rights of others.
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
TE Connectivity:
LM31-00000F-015PG LM31-00000F-002PG