TECHNICAL DATA TECHNICAL NOTES
1Limit values
2Average life of 100.000 h with TA= +25 °C
3With L/D input not connected the proximity
models function in the light mode and the
retroreflex and through beam models in the
dark mode; the light mode can be selected
connecting the L/D input to +Vdc, the dark
mode connecting it to 0Vdc
4PVC, 4 x 0.14 mm2
5A - reverse polarity protection
B - overload and short-circuit protection
C00 - long diffuse proximity A00 - retroreflex
F00/G001 - through beam
C10 - short diffuse proximity
B00 - polarised retroreflex
R2
R2
White 90%
Grey 18% White 90%
Grey 18%
S15-PA-2-A00
S15-PA-2-B00
S15-PA-2-C00
S15-PA-2-C10
S15-PA-2-F00
S15-PA-2-G00
DETECTION DIAGRAMS
Long diffuse proximity operating distance: 1 ... 35 cm
Short diffuse proximity operating distance: 1 ... 10 cm
Retroreflex operating distance: 0,1…4 m on R2
Polarised retroreflx operating distance: 0,1…3 m on R2
Through beam operating distance: 0…20 m
Power supply: 12 ... 30 Vdc
Ripple: ≤ 2 Vpp
Consumption: ≤ 30 mA
Light emission : infrared LED 880 nm
red LED 660 nm
Indicators: yellow OUTPUT LED
green POWER LED
Output type: PNP(-PP suffix)
NPN (-NN suffix)
Output current: ≤ 100 mA
Saturation voltage: ≤ 2 V
Response time: 1 ms
4 ms
Switching frequency: ≤ 500 Hz
≤ 120 Hz
Operating mode: selectable dark/light
Auxiliary functions: Test + and Test -
Connections: 2 m Ø 4 mm cable
Electrical protection: class 2
Mechanical protection: IP69K
Protection devices: A, B
Housing material: PBT
Lens material: plastic PMMA
Weight: 75 g max.
Operating temperature: -25 ... +55°C
Storage temperature: -25 ... +70°C
Reference standard: EN 60947-5-2, UL 508
1
5
4
3
2
R5
R5