Series AM50HB-UZ 50 Watt | Half Brick DC-DC Converter FEATURES: * RoHS compliant * Wide 2:1 Input range * Very low ripple and noise * On/Off Control and Trim Function * * * * Regulated output High efficiency Operating temperature range: -40 to +85C 1500VDC I/O Isolation Models Single output Model AM50HB-2403S-UZ AM50HB-2405S-UZ AM50HB-2412S-UZ AM50HB-2415S-UZ AM50HB-2424S-UZ AM50HB-2428S-UZ AM50HB-2448S-UZ AM50HB-4803S-UZ AM50HB-4805S-UZ AM50HB-4812S-UZ AM50HB-4815S-UZ AM50HB-4824S-UZ AM50HB-4828S-UZ AM50HB-4848S-UZ AM50HB-11005S-UZ AM50HB-11012S-UZ AM50HB-11015S-UZ AM50HB-11024S-UZ AM50HB-11048S-UZ Input Voltage (V) Output Voltage (V) Output Current max (A) Input Filter 18-36 18-36 18-36 18-36 18-36 18-36 18-36 36-72 36-72 36-72 36-72 36-72 36-72 36-72 66-160 66-160 66-160 66-160 66-160 3.3 5 12 15 24 28 48 3.3 5 12 15 24 28 48 5 12 15 24 48 10 10 4.2 3.2 2.1 1.8 1.1 10 10 4.2 3.2 2.1 1.8 1.1 10 4.2 3.2 2.1 1.1 type type L type L type L type L type L type type type L type L type L type L type L type type L type L type L type L type NOTE: All specifications are measured at an ambient temperature of 25C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Voltage range Remote Control Nominal Typical 24 48 110 CNTRL open CNTRL connect to -Vin 18-36 36-72 66-160 On Off 10 150 Turn on time Start-up Delay Time Maximum Units VDC -0.7 ~ 0.4 V ms ms Isolation Specifications Parameters Tested I/O voltage Tested Input / Case voltage Tested Output / Case voltage Conditions Typical 1 Min 1 Min 1 Min 1500 500 500 Conditions Typical Maximum Units VDC VDC VDC Output Specifications Parameters Set point accuracy Trim range Dynamic Response Short Circuit protection www.aimtec.com F 054e R3.A 200s setting time 1 10 50-75% & 50-25% load Continuous Tel: +1 514 620 2722 1 of 5 Maximum Units 3% of Vout % % Pk deviation Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM50HB-UZ 50 Watt | Half Brick DC-DC Converter Output Specifications (continued) Parameters Short Circuit restart Over Temperature Protection Total remote sense compensation Line voltage regulation Load voltage regulation Temperature coefficient Ripple & Noise Conditions Typical Auto recovery 110 0.5 0.2 0.5 0.02 1 >105 20MHz Bandwidth Maximum Units o 115 C V % of Vin % %/oC % of Vout Maximum Units General Specifications Parameters Switching frequency Efficiency Pin Solder Temperature Hand Soldering time Operating temperature Storage temperature Max Case temperature Cooling Humidity Weight Dimensions (L x W x H) MTBF Conditions Typical 100% load At full load Wave solder <10s Iron Temperature: 425 oC 330 87-90 250 5 -40 to +85 -55 to +125 Without Heatsink KHz % o C sec o C o C o C 100 See derating graph 10 to 90 % 75 g 2.28 x 2.40 x 0.50 inches 57.9 x 61.0 x 12.7 mm >1,500,000 hrs (Bellcore TR332, t=+25oC) Safety Specifications Standards Safety Pin Out Specifications Pin Single 1 2 3 4 5 6 7 8 9 10 -V Input Case On/Off Control +V Input +V Output +Sense Trim -Sense -V Output Omitted www.aimtec.com F 054e R3.A Meets EN60950 Dimensions Tel: +1 514 620 2722 2 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM50HB-UZ 50 Watt | Half Brick DC-DC Converter Derating: Typical Application: Aimtec's half brick models can operate independently. However, to enhance their performance and to ensure precision of the output signal parameters the following connections are recommended: Output Ripple and Noise Measurement test setup: www.aimtec.com F 054e R3.A Tel: +1 514 620 2722 3 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM50HB-UZ 50 Watt | Half Brick DC-DC Converter Please refer to our Application note: Ripple and Noise Measurement of Brick & POL DC-DC Converters. ON/OFF Control: The converter output can be disabled by moving SW to position "a" - connected to -Vin with voltage level between -0.7 and 0.4V. When SW is open in position "b", the converter is ON and operates normally. The SW can be replaced by a NPN transistor with connection as follows: Output Voltage Trim connection: The output voltage can be adjusted by connecting trim resistors as shown. www.aimtec.com F 054e R3.A Tel: +1 514 620 2722 4 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM50HB-UZ 50 Watt | Half Brick DC-DC Converter The values can be determined according to the following formulas where % is the desirable voltage adjustment in percentage and Vo is the Nominal value of the Output Voltage: Rup = Rdown Vo(100+%) - (100+2%) 1.225% % = 100 - 2 % K K The calculated Resistor values are in K. NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 5. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. www.aimtec.com F 054e R3.A Tel: +1 514 620 2722 5 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only