Pushbutton Switches/Indicators A22R/M22R series Robust and Graceful design Pushbutton Switches Push Button This document provides information mainly for selecting suitable models. Please read the document Instruction Sheet carefully for information that the user must understand and accept before purchase, including information on warranty, limitations of liability, and precautions. OMRON Corporation Industrial Automation Company Sensing Devices Division H.Q. Industrial Sensors Division Shiokoji Horikawa, Shimogyo-ku, Kyoto, 600-8530 Japan Tel: (81)75-344-7022/Fax: (81)75-344-7107 Regional Headquarters OMRON EUROPE B.V. Wegalaan 67-69-2132 JD Hoofddorp The Netherlands Tel: (31)2356-81-300/Fax: (31)2356-81-388 OMRON ELECTRONICS LLC One Commerce Drive Schaumburg, IL 60173-5302 U.S.A. Tel: (1) 847-843-7900/Fax: (1) 847-843-7787 Authorized Distributor: OMRON ASIA PACIFIC PTE. LTD. No. 438A Alexandra Road # 05-05/08 (Lobby 2), Alexandra Technopark, Singapore 119967 Tel: (65) 6835-3011/Fax: (65) 6835-2711 OMRON (CHINA) CO., LTD. Room 2211, Bank of China Tower, 200 Yin Cheng Zhong Road, PuDong New Area, Shanghai, 200120, China Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200 OMRON Industrial Automation Global: www.ia.omron.com (c) OMRON Corporation 2009 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. Printed in Japan Cat. No. A190-E1-01 1009 Secure and Human-centered 2 A22R/M22R Series Push Button Responds with high grade illumination to 1 A22R/M22R Series Push Button various needs 2 Round design Soft to the touch Gentle design for human. Shining Metal Ring 4 Switch units Provides shining and robust metal ring. 2 Switch units 4 3 Additional unit type Switch unit can be added. Compact size The body length under a panel decreased by 15% compare with our former products. 15% decrease compare with the current product 46.8 mm 3 2 A22R/M22R Series Push Button Responds with high grade illumination to 1 A22R/M22R Series Push Button various needs 2 Round design Soft to the touch Gentle design for human. Shining Metal Ring 4 Switch units Provides shining and robust metal ring. 2 Switch units 4 3 Additional unit type Switch unit can be added. Compact size The body length under a panel decreased by 15% compare with our former products. 15% decrease compare with the current product 46.8 mm 3 Lighted Type 4 A22R/M22R Series Push Button A22R/M22R Series Push Button Assembled Models Non-l i gh t ed Non-ligh e d Type Type Operation Units Lighted L ig h te d T Type yp e N Non-lighted on-light ed Type Flat type A22R-F @ - @ Flat type Projection type Projection type A22R-F @ - @ @ A22R-T @ - @ @ A22RL-T @ - @ - @ @ Light Lighted ed Type Projection type A22R-T @ - @ Select or N on-light ed Type Selector Non-lighted Selec torr N o n - l i g h t e d Type Selecto T y pe Select or Light ed Ty pe Selector Lighted Type Selector Se le cto r Lighted L ig h te d Type T yp e 2 notches A22RS-2 @ 2 notches 3 notches 2 notches 3 notches A22RS-2 @ - @ A22RS-3 @ - @ A22RW-2 @ @ - @ - @ A22RW-3 @ @ - @ - @ Key Sel e ct c t o r Type Type Projection type A22RL-T @ - @ In d ica to r Indicator 3 notches A22RS-3 @ Key Select or Selector 2 notches A22RW-2 @ @ Sw it ch U nit Switch Unit 3 notches A22RW-3 @ @ Soc k et Socket Emergency Stop Switch 2 notches A22RK-2 @ 2 notches 3 notches Indicator *Emergency A22RK-2 @ - @ A22RK-3 @ - @ M22R-E @ - @ A22E- @ - @ - @ - @ 3 notches A22RK-3 @ Switch with Lamp socket A22RL- @ M - @ Switch Block Lamp Socket Mounting Plate Switch block A22R- @ Lamp socket A22R- @ Mounting plate A22R-3200 Socket A22R- @ M LED * Refer to the Safety Components Series Catalog (Cat. No. Y106) for detail. LED A22R - @ @ 5 Lighted Type 4 A22R/M22R Series Push Button A22R/M22R Series Push Button Assembled Models Non-l i gh t ed Non-ligh e d Type Type Operation Units Lighted L ig h te d T Type yp e N Non-lighted on-light ed Type Flat type A22R-F @ - @ Flat type Projection type Projection type A22R-F @ - @ @ A22R-T @ - @ @ A22RL-T @ - @ - @ @ Light Lighted ed Type Projection type A22R-T @ - @ Select or N on-light ed Type Selector Non-lighted Selec torr N o n - l i g h t e d Type Selecto T y pe Select or Light ed Ty pe Selector Lighted Type Selector Se le cto r Lighted L ig h te d Type T yp e 2 notches A22RS-2 @ 2 notches 3 notches 2 notches 3 notches A22RS-2 @ - @ A22RS-3 @ - @ A22RW-2 @ @ - @ - @ A22RW-3 @ @ - @ - @ Key Sel e ct c t o r Type Type Projection type A22RL-T @ - @ In d ica to r Indicator 3 notches A22RS-3 @ Key Select or Selector 2 notches A22RW-2 @ @ Sw it ch U nit Switch Unit 3 notches A22RW-3 @ @ Soc k et Socket Emergency Stop Switch 2 notches A22RK-2 @ 2 notches 3 notches Indicator *Emergency A22RK-2 @ - @ A22RK-3 @ - @ M22R-E @ - @ A22E- @ - @ - @ - @ 3 notches A22RK-3 @ Switch with Lamp socket A22RL- @ M - @ Switch Block Lamp Socket Mounting Plate Switch block A22R- @ Lamp socket A22R- @ Mounting plate A22R-3200 Socket A22R- @ M LED * Refer to the Safety Components Series Catalog (Cat. No. Y106) for detail. LED A22R - @ @ 5 A22R/M22R Series Push Button Assembled Models Assembled Models Pushbutt Pus hbutt o on n Switc che hes Selector Select or Switches Sw it ches Non-lighted/Lighted 1b A22R-FB-01@ 1b A22R-FR-01@ 1a A22R-TW-10@ 1a A22R-TB-10@ A22R-TY-10@ 1a A22R-TA-10@ 1b A22R-TB-01@ 1b A22R-TR-01@ A22RW-2@@-@-@ 2 notches AC, DC 24V Projection 46.8 A22RW-3@@-@-@ 3 notches AC, DC 24V Insert one of the following letters into the box @. M: Momentary A: Alternate A22RL-TG-24A-10@ 1a A22RL-TR-24A-10@ 1a A22RL-TY-24A-10@ 1a A22RL-TA-24A-10@ 1a A22RL-TW-T2-10@ 1a A22RL-TG-T2-10@ 1a A22RL-TR-T2-10@ 1a A22RL-TY-T2-10@ 1a A22RL-TA-T2-10@ 29.8 23.7 Projection AC 220V Insert one of the following letters into the box @. M: Momentary A: Alternate 46.8 0.5 1a 16.7 A22RL-TW-24A-10@ 6 Projection AC, DC 24V 1a 10 A22RL-T@-@-@@ A22RS-3M-20 2a A22RS-3A-20 29.8 1a A22RW-2MG-24A-10 1a1b A22RW-2MR-24A-11 1a A22RW-2AY-24A-10 1a1b A22RW-2AA-24A-11 2a A22RW-3MG-24A-20 2a A22RW-3MR-24A-20 2a A22RW-3AY-24A-20 2a A22RW-3AA-24A-20 29.8 6 1a 2a 3 notches 0.5 A22R-TR-01@ A22RS-2A-11 * These Non-lighted types provide black knobs. 29.8 16.7 10 1a 1a1b 6 A22R-TG-10@ A22RS-2A-10 29.8 29.8 23.7 1a 1a 24.2 A22R-FA-10@ A22RS-3@-@ A22RS-2M-11 10 1a 29.8 1a1b 28 R2 7 0.5 A22R-FY-10@ A22RS-2M-10 6 1a Dimensions 46.8 A22R-FR-10@ Part No. 24.2 1a Contact form 0.5 A22R-FG-10@ 36 2 notches 1a Knob Knob position color 1a A22RS-2@-@ R2 7 A22R-FB-10@ Insert one of the following letters into the box @. M: Momentary A: Alternate A22R-T@-@@ Number of notch 10 Round/Flat Appearance 28 A22R-FW-10@ 10 1a Dimensions 0.5 1a A22R-F@-@@ Part No. 10.8 Contact form 6 Pushbutton color 46.8 Pushbutton shape 36 Non-lighted/Lighted Appearance 7 A22R/M22R Series Push Button 46.8 6 A22R/M22R Series Push Button Assembled Models Assembled Models Pushbutt Pus hbutt o on n Switc che hes Selector Select or Switches Sw it ches Non-lighted/Lighted 1b A22R-FB-01@ 1b A22R-FR-01@ 1a A22R-TW-10@ 1a A22R-TB-10@ A22R-TY-10@ 1a A22R-TA-10@ 1b A22R-TB-01@ 1b A22R-TR-01@ A22RW-2@@-@-@ 2 notches AC, DC 24V Projection 46.8 A22RW-3@@-@-@ 3 notches AC, DC 24V Insert one of the following letters into the box @. M: Momentary A: Alternate A22RL-TG-24A-10@ 1a A22RL-TR-24A-10@ 1a A22RL-TY-24A-10@ 1a A22RL-TA-24A-10@ 1a A22RL-TW-T2-10@ 1a A22RL-TG-T2-10@ 1a A22RL-TR-T2-10@ 1a A22RL-TY-T2-10@ 1a A22RL-TA-T2-10@ 29.8 23.7 Projection AC 220V Insert one of the following letters into the box @. M: Momentary A: Alternate 46.8 0.5 1a 16.7 A22RL-TW-24A-10@ 6 Projection AC, DC 24V 1a 10 A22RL-T@-@-@@ A22RS-3M-20 2a A22RS-3A-20 29.8 1a A22RW-2MG-24A-10 1a1b A22RW-2MR-24A-11 1a A22RW-2AY-24A-10 1a1b A22RW-2AA-24A-11 2a A22RW-3MG-24A-20 2a A22RW-3MR-24A-20 2a A22RW-3AY-24A-20 2a A22RW-3AA-24A-20 29.8 6 1a 2a 3 notches 0.5 A22R-TR-01@ A22RS-2A-11 * These Non-lighted types provide black knobs. 29.8 16.7 10 1a 1a1b 6 A22R-TG-10@ A22RS-2A-10 29.8 29.8 23.7 1a 1a 24.2 A22R-FA-10@ A22RS-3@-@ A22RS-2M-11 10 1a 29.8 1a1b 28 R2 7 0.5 A22R-FY-10@ A22RS-2M-10 6 1a Dimensions 46.8 A22R-FR-10@ Part No. 24.2 1a Contact form 0.5 A22R-FG-10@ 36 2 notches 1a Knob Knob position color 1a A22RS-2@-@ R2 7 A22R-FB-10@ Insert one of the following letters into the box @. M: Momentary A: Alternate A22R-T@-@@ Number of notch 10 Round/Flat Appearance 28 A22R-FW-10@ 10 1a Dimensions 0.5 1a A22R-F@-@@ Part No. 10.8 Contact form 6 Pushbutton color 46.8 Pushbutton shape 36 Non-lighted/Lighted Appearance 7 A22R/M22R Series Push Button 46.8 6 8 A22R/M22R Series Key/Signal Indicator/Construction A22R/M22R Series Key/Signal Indicator/Construction Assembled Models Structure Selector tor S w i t ch ches Selec A22R ser ies Key Selector Number of notch Key position Contact form 1a A22RK-2@-@ 2 notches Part No. Dimensions A22RK-2ML-10 1a1b A22RK-2ML-11 1a A22RK-2M-10 1a1b A22RK-2M-11 1a A22RK-2AL-10 1a1b A22RK-2AL-11 Pushbutton unit 28 R2 7 36 Appearance 29.8 27 : key release position 2a A22RK-3M-20 2a A22RK-3MC-20 2a A22RK-3AC-20 LED Lighting source * LED 0.5 A22RK-3ML-20 19 2a 10 A22RK-3@-@ 6 3 notches 46.8 Body unit : key release position Contact form * 1a,1b Lighting method * Non-lighted * Without voltage-reduction unit * With voltage reduction unit I ndi c ator Indicator All-in-one type LED rating Indicator color Part No. Dimensions M22R-EG-24A AC, DC 24V Indicator M22R-ER-24A Lighting source * LED 0.5 M22R-EA-24A 14.4 M22R-EY-24A M22R-EW-T2 M22R-ER-T2 M22R-EY-T2 M22R-EA-T2 6 M22R-EG-T2 AC 220V M22R ser ies 29.8 M22R-EW-24A M22R-E@-@ 40.5 Appearance 9 8 A22R/M22R Series Key/Signal Indicator/Construction A22R/M22R Series Key/Signal Indicator/Construction Assembled Models Structure Selector tor S w i t ch ches Selec A22R ser ies Key Selector Number of notch Key position Contact form 1a A22RK-2@-@ 2 notches Part No. Dimensions A22RK-2ML-10 1a1b A22RK-2ML-11 1a A22RK-2M-10 1a1b A22RK-2M-11 1a A22RK-2AL-10 1a1b A22RK-2AL-11 Pushbutton unit 28 R2 7 36 Appearance 29.8 27 : key release position 2a A22RK-3M-20 2a A22RK-3MC-20 2a A22RK-3AC-20 LED Lighting source * LED 0.5 A22RK-3ML-20 19 2a 10 A22RK-3@-@ 6 3 notches 46.8 Body unit : key release position Contact form * 1a,1b Lighting method * Non-lighted * Without voltage-reduction unit * With voltage reduction unit I ndi c ator Indicator All-in-one type LED rating Indicator color Part No. Dimensions M22R-EG-24A AC, DC 24V Indicator M22R-ER-24A Lighting source * LED 0.5 M22R-EA-24A 14.4 M22R-EY-24A M22R-EW-T2 M22R-ER-T2 M22R-EY-T2 M22R-EA-T2 6 M22R-EG-T2 AC 220V M22R ser ies 29.8 M22R-EW-24A M22R-E@-@ 40.5 Appearance 9 10 A22R/M22R Series Push Button A22R/M22R Series Push Button Individual Unit Individual Unit Selector Select or unit Pushbutt P us hbutt o n u n i t Non-lighted/Lighted Appearance Non-lighted/Lighted Pushbutton shape Pushbutton color Part No. Dimensions A22R-FW-@ A22R-F@-@ 29.8 Appearance Number of notch A22RS-2@ Knob Knob position color Part No. Dimensions 29.8 A22RS-2M A22R-FB-@ A22RS-2A A22R-FG-@ 2 notches A22R-FR-@ Round/Flat 0.5 * These Non-lighted types provide black knobs. 22 6 3 notches 24.2 A22RS-3A 10 0.5 10.8 6 Insert one of the following letters into the box @. M: Momentary A: Alternate A22RS-3M A22RS-3@ 22 A22R-FA-@ 10 A22R-FY-@ A22R-TW-@ A22R-T@-@ 0.5 A22RW-2MY Insert one of the following letters into the box @. M: Momentary A: Alternate A22RW-2MA A22RW-2AG 10 A22RW-2AR A22RL-TW-@ A22RL-T@-@ A22RW-2AY 0.5 A22RW-3MG A22RW-3@ 6 A22RL-TY-@ A22RL-TA-@ Insert one of the following letters into the box @. M: Momentary A: Alternate A22RW-3MR 3 notches Lighted Type A22RW-3MY A22RW-3AA A22RW-3AG A22RW-3AR 22 A22RW-2AA 22 Projection Lighted type 16.7 10 A22RL-TR-@ 6 A22RL-TG-@ 0.5 2 notches Lighted Type A22R-TA-@ 24.2 A22R-TY-@ A22RW-2MR 6 A22R-TR-@ A22RW-2MG A22RW-2@ 22 A22R-TG-@ 16.7 10 A22R-TB-@ Projection 11 10 A22R/M22R Series Push Button A22R/M22R Series Push Button Individual Unit Individual Unit Selector Select or unit Pushbutt P us hbutt o n u n i t Non-lighted/Lighted Appearance Non-lighted/Lighted Pushbutton shape Pushbutton color Part No. Dimensions A22R-FW-@ A22R-F@-@ 29.8 Appearance Number of notch A22RS-2@ Knob Knob position color Part No. Dimensions 29.8 A22RS-2M A22R-FB-@ A22RS-2A A22R-FG-@ 2 notches A22R-FR-@ Round/Flat 0.5 * These Non-lighted types provide black knobs. 22 6 3 notches 24.2 A22RS-3A 10 0.5 10.8 6 Insert one of the following letters into the box @. M: Momentary A: Alternate A22RS-3M A22RS-3@ 22 A22R-FA-@ 10 A22R-FY-@ A22R-TW-@ A22R-T@-@ 0.5 A22RW-2MY Insert one of the following letters into the box @. M: Momentary A: Alternate A22RW-2MA A22RW-2AG 10 A22RW-2AR A22RL-TW-@ A22RL-T@-@ A22RW-2AY 0.5 A22RW-3MG A22RW-3@ 6 A22RL-TY-@ A22RL-TA-@ Insert one of the following letters into the box @. M: Momentary A: Alternate A22RW-3MR 3 notches Lighted Type A22RW-3MY A22RW-3AA A22RW-3AG A22RW-3AR 22 A22RW-2AA 22 Projection Lighted type 16.7 10 A22RL-TR-@ 6 A22RL-TG-@ 0.5 2 notches Lighted Type A22R-TA-@ 24.2 A22R-TY-@ A22RW-2MR 6 A22R-TR-@ A22RW-2MG A22RW-2@ 22 A22R-TG-@ 16.7 10 A22R-TB-@ Projection 11 A22R/M22R Series Key/Switch Section/Mounting Console Individual Unit Individual Unit Switch Sw it ch / Lamp units unit s Selector Selec tor u n i t Switch unit Number of notch Key position Part No. Appearance Dimensions Unit A22R-@ A22RK-2@ 29.8 A22RK-2ML Contact block A22RK-2M Contact form Part No. 1a A22R-10 1b A22R-01 Dimensions 9.8 5.6 4 * Additional one block can be mountet to make 2a, 2b, or 1a1b. 26.5 Key Selector Appearance 13 A22R/M22R Series Key/Switch Section/Mounting Console 23.5 12 2 notches A22RK-2AL 36 : key release position Lamp socket 27 A22RK-3@ A22RK-3ML Appearance Unit Rating Part No. Dimensions A22RK-3M 22 6 With voltage reduction unit AC220V A22R-T2 Lamp socket : key release position 26.5 A22RK-3AC A22R-TN 23.5 A22RK-3MC 10.3 Without voltage reduction unit AC/DC6V, AC/DC12V, AC/DC24V 16.3 A22R-@ 19 10 0.5 3 notches 9.8 36 Switch Switc h un unii t For Lighted type Standard AC 220V Part No. 1a A22RL-10M 1b A22RL-01M 2a A22RL-20M 2b 1a1b A22RL-02M A22RL-11M 1a A22RL-10M-T2 1b A22RL-01M-T2 2a A22RL-20M-T2 2b 1a1b A22RL-02M-T2 A22RL-11M-T2 Mounting Mount ing plate plat e Dimensions 29.8 Appearance 10.3 Socket 28 Mounting plate A22R-3200 29.8 Contact form Part No. Dimensions 1a A22R-10M 29.8 1b A22R-01M 2a A22R-20M 1a1b A22R-11M 2b A22R-02M 10.5 A22R-@M Dimensions R2 7 33.5 Type Part No. A22R-3200 For Non-lighted type Appearance Unit 36 A22RL-@M-@ Contact form 6.3 Type 39.8 Appearance A22R/M22R Series Key/Switch Section/Mounting Console Individual Unit Individual Unit Switch Sw it ch / Lamp units unit s Selector Selec tor u n i t Switch unit Number of notch Key position Part No. Appearance Dimensions Unit A22R-@ A22RK-2@ 29.8 A22RK-2ML Contact block A22RK-2M Contact form Part No. 1a A22R-10 1b A22R-01 Dimensions 9.8 5.6 4 * Additional one block can be mountet to make 2a, 2b, or 1a1b. 26.5 Key Selector Appearance 13 A22R/M22R Series Key/Switch Section/Mounting Console 23.5 12 2 notches A22RK-2AL 36 : key release position Lamp socket 27 A22RK-3@ A22RK-3ML Appearance Unit Rating Part No. Dimensions A22RK-3M 22 6 With voltage reduction unit AC220V A22R-T2 Lamp socket : key release position 26.5 A22RK-3AC A22R-TN 23.5 A22RK-3MC 10.3 Without voltage reduction unit AC/DC6V, AC/DC12V, AC/DC24V 16.3 A22R-@ 19 10 0.5 3 notches 9.8 36 Switch Switc h un unii t For Lighted type Standard AC 220V Part No. 1a A22RL-10M 1b A22RL-01M 2a A22RL-20M 2b 1a1b A22RL-02M A22RL-11M 1a A22RL-10M-T2 1b A22RL-01M-T2 2a A22RL-20M-T2 2b 1a1b A22RL-02M-T2 A22RL-11M-T2 Mounting Mount ing plate plat e Dimensions 29.8 Appearance 10.3 Socket 28 Mounting plate A22R-3200 29.8 Contact form Part No. Dimensions 1a A22R-10M 29.8 1b A22R-01M 2a A22R-20M 1a1b A22R-11M 2b A22R-02M 10.5 A22R-@M Dimensions R2 7 33.5 Type Part No. A22R-3200 For Non-lighted type Appearance Unit 36 A22RL-@M-@ Contact form 6.3 Type 39.8 Appearance 14 A22R/M22R Series LED/Button/Knob/Key/Signal Indicator A22R/M22R Series LED/Button/Knob/Key/Signal Indicator Individual Unit Nomenclature Lamp unit uni t Nomenclature N omenclat ure LED Completely Assembled A22R@-@@-@-@@ Pushbutton switches LED operating voltage Lighting color Part No. Dimensions Lighting A22R-6AW A22R-@@ LED AC/DC6V A22R@--@@--@--@@ Pushbutton Shape Lighting Color Light Source A22R-6AG Code Lighting Code Shape Code Color F A22R-6AR NonBlank lighted Flat * R Red G Y W Yellow White L A22R-6AY Lighted T Projection * For Non-lighted type only A22R-6AA A A22R-12AW 9.6 A22R-12AG LED AC/DC12V A22R-12AR B Green Blank No light source AC/DC6V 6A 12A AC/DC12V 24A Blue Black * Code Operating Voltage T2 AC220V 9.3 A22R-24AG A22R-24AR A22R-24AY A22R-24AA Code Contact Form 10 1a 01 11 20 1b 1a1b 2a 02 2b Code Switch Operation M Momentary action A Alternate action Use AC/DC24V LED A22R-12AA LED AC/DC24V AC/DC24V Light Source A22R-12AY A22R-24AW Contact Form Switch Operation Operating Voltage Code * For Non-lighted type only BA9S/13 20 Appearance 15 Completely Assembled A22R@-@@-@-@ Selector switches A22R@--@@--@--@ Lighting Code Lighting S Nonlighted W Lighted Number of Notches/Reset Method Lighting Color Code 2M 2A 3M 3A 3MA 3AM Specification Code Color Blank Black* 2 notches/Manual 2 notches/Automatic 3 notches/Manual 3 notches/Automatic 3 notches/Manual - left side, Automatic - right side 3 notches/Automatic - left side, Manual - right side R Red G Green Y A Yellow 2ML 2M 2AL 3ML 3M Number of notches, Reset method, Key release position 2 notches, Manual, Left 2 notches, Manual, Left and Right 2 notches, Automatic, Left 3 notches, Manual, Left 3 notches, Manual, Left and Right 3MC 3 notches, Manual, Center 3AC 3 notches, Automatic, Center 3 notches, Manual - left, 3MAL Automatic - right, Left 3 notches, Automatic - 3AMR left, Manual - right, Right Operating Voltage Blank No-lighted type 10 1a** 6A 12A 24A AC/DC6V AC/DC12V AC/DC24V 01 11 20 1a1b 2a 02 2b Code Contact Form Light Source Code Operating Voltage 1b** ** For models with 2 notches AC220V T2 Use AC/DC24V LED Completely Assembled M22R-@@-@ Indicator M22R--@@--@ A22RK--@--@ Code Contact Form Code Blue * Non-lighted type only Completely Assembled A22RK-@-@ Key selector switches Number of Notches/Reset method Light Source Contact Form Code Contact Form 10 01 11 20 02 1a** 1b** 1a1b 2a 2b ** For models with 2 notches Structure Code Type All-inE one type Lighting Color Lighting Code Color Light Source R Red Operating Voltage 12A AC/DC12V G Y W Green 24A AC/DC24V Yellow White A Blue Code Voltage Reduction Unit Operating Code Voltage T2 AC220V 14 A22R/M22R Series LED/Button/Knob/Key/Signal Indicator A22R/M22R Series LED/Button/Knob/Key/Signal Indicator Individual Unit Nomenclature Lamp unit uni t Nomenclature N omenclat ure LED Completely Assembled A22R@-@@-@-@@ Pushbutton switches LED operating voltage Lighting color Part No. Dimensions Lighting A22R-6AW A22R-@@ LED AC/DC6V A22R@--@@--@--@@ Pushbutton Shape Lighting Color Light Source A22R-6AG Code Lighting Code Shape Code Color F A22R-6AR NonBlank lighted Flat * R Red G Y W Yellow White L A22R-6AY Lighted T Projection * For Non-lighted type only A22R-6AA A A22R-12AW 9.6 A22R-12AG LED AC/DC12V A22R-12AR B Green Blank No light source AC/DC6V 6A 12A AC/DC12V 24A Blue Black * Code Operating Voltage T2 AC220V 9.3 A22R-24AG A22R-24AR A22R-24AY A22R-24AA Code Contact Form 10 1a 01 11 20 1b 1a1b 2a 02 2b Code Switch Operation M Momentary action A Alternate action Use AC/DC24V LED A22R-12AA LED AC/DC24V AC/DC24V Light Source A22R-12AY A22R-24AW Contact Form Switch Operation Operating Voltage Code * For Non-lighted type only BA9S/13 20 Appearance 15 Completely Assembled A22R@-@@-@-@ Selector switches A22R@--@@--@--@ Lighting Code Lighting S Nonlighted W Lighted Number of Notches/Reset Method Lighting Color Code 2M 2A 3M 3A 3MA 3AM Specification Code Color Blank Black* 2 notches/Manual 2 notches/Automatic 3 notches/Manual 3 notches/Automatic 3 notches/Manual - left side, Automatic - right side 3 notches/Automatic - left side, Manual - right side R Red G Green Y A Yellow 2ML 2M 2AL 3ML 3M Number of notches, Reset method, Key release position 2 notches, Manual, Left 2 notches, Manual, Left and Right 2 notches, Automatic, Left 3 notches, Manual, Left 3 notches, Manual, Left and Right 3MC 3 notches, Manual, Center 3AC 3 notches, Automatic, Center 3 notches, Manual - left, 3MAL Automatic - right, Left 3 notches, Automatic - 3AMR left, Manual - right, Right Operating Voltage Blank No-lighted type 10 1a** 6A 12A 24A AC/DC6V AC/DC12V AC/DC24V 01 11 20 1a1b 2a 02 2b Code Contact Form Light Source Code Operating Voltage 1b** ** For models with 2 notches AC220V T2 Use AC/DC24V LED Completely Assembled M22R-@@-@ Indicator M22R--@@--@ A22RK--@--@ Code Contact Form Code Blue * Non-lighted type only Completely Assembled A22RK-@-@ Key selector switches Number of Notches/Reset method Light Source Contact Form Code Contact Form 10 01 11 20 02 1a** 1b** 1a1b 2a 2b ** For models with 2 notches Structure Code Type All-inE one type Lighting Color Lighting Code Color Light Source R Red Operating Voltage 12A AC/DC12V G Y W Green 24A AC/DC24V Yellow White A Blue Code Voltage Reduction Unit Operating Code Voltage T2 AC220V 16 A22R/M22R Series Switch Section/ Indicator Section/LED A22R/M22R Series Switch Section/ Indicator Section/LED Individual Unit Nomenclature Nomenc Nomencll a att u r e N omenclat ure Nomenclature Individual unit (Switch unit) A22R@-@M-@ Individual unit (Pushbutton unit) A22R@-@@-@ Pushbutton switches A22R@--@M--@ A22R@--@@--@ Lighting Code Lighting Blank Non-lighted L Lighted Pushbutton Shape Pushbutton Color Code Pushbutton Shape F Flat* T Projection *For Non-lighted type only Switch Operation Code Pushbutton Color Code Switch Operation Lighting Code Lighting Blank Non-lighted Contact Form Switch Operation Code Contact Form Code Switch Operation 10 1a Yellow White 01 11 20 1a1b 2a Blue 02 2b R Red M Momentary action G Y W Green A Alternate action A L Lighted M Voltage Reduction Unit Momentary action Code Operation Voltage Blank Non-lighted type AC220V* T2 1b *Use with an A22R-24@LED B Black* *For Non-lighted type only Individual unit (Switch block) A22R-@ Individual unit (Selector unit) A22R@-@@ Selector switches A22R@--@@ Lighting Code Lighting S Non-lighted W Lighted Number of notches, Reset Method Number of notches, Reset Method 2M 2 notches, Manual 2A 2 notches, Automatic 3M 3 notches, Manual 3A 3 notches, Automatic 3MA 3 notches, Manual - left, Automatic - right 3AM 3 notches, Automatic - left, Manual - right Individual unit (Key selector unit) A22RK-@ Key selector switches A22RK--@ Number of notches, Reset Method, Key Release Position Code Number of notches, Reset Method, Key Release Position 2ML 2 notches, Manual, Left 2M 2 notches, Manual, Left and Right 2AL 2 notches, Automatic, Left 3ML 3 notches, Manual, Left 3M 3 notches, Manual, Left and Right 3MC 3 notches, Manual, Center 3AC 3 notches, Automatic, Center 3MAL 3 notches, Manual - left, Automatic - right, Left 3AMR 3 notches, Automatic - left, Manual - right, Right Knob Color Code Color Blank Black* Red R G Y Green Yellow A Blue Individual unit (Voltage-reduction unit) A22R-@ A22R--@ A22R--@ Code 17 Contact Form Body unit Code Contact Form 10 1a 01 1b Code Operating Voltage TN AC/DC6V, AC/DC12V, AC/DC24V T2 AC220V* *Use with an A22R-24@LED *Non-lighted type Individual unit (LED) A22R-@ @ LED A22R--@@ Operating Voltage Code Operating Voltage 6A AC/DC6V 12A AC/DC12V 24A AC/DC24V Lighting color Code Lighting color R Red G Y W Green Yellow White A Blue 16 A22R/M22R Series Switch Section/ Indicator Section/LED A22R/M22R Series Switch Section/ Indicator Section/LED Individual Unit Nomenclature Nomenc Nomencll a att u r e N omenclat ure Nomenclature Individual unit (Switch unit) A22R@-@M-@ Individual unit (Pushbutton unit) A22R@-@@-@ Pushbutton switches A22R@--@M--@ A22R@--@@--@ Lighting Code Lighting Blank Non-lighted L Lighted Pushbutton Shape Pushbutton Color Code Pushbutton Shape F Flat* T Projection *For Non-lighted type only Switch Operation Code Pushbutton Color Code Switch Operation Lighting Code Lighting Blank Non-lighted Contact Form Switch Operation Code Contact Form Code Switch Operation 10 1a Yellow White 01 11 20 1a1b 2a Blue 02 2b R Red M Momentary action G Y W Green A Alternate action A L Lighted M Voltage Reduction Unit Momentary action Code Operation Voltage Blank Non-lighted type AC220V* T2 1b *Use with an A22R-24@LED B Black* *For Non-lighted type only Individual unit (Switch block) A22R-@ Individual unit (Selector unit) A22R@-@@ Selector switches A22R@--@@ Lighting Code Lighting S Non-lighted W Lighted Number of notches, Reset Method Number of notches, Reset Method 2M 2 notches, Manual 2A 2 notches, Automatic 3M 3 notches, Manual 3A 3 notches, Automatic 3MA 3 notches, Manual - left, Automatic - right 3AM 3 notches, Automatic - left, Manual - right Individual unit (Key selector unit) A22RK-@ Key selector switches A22RK--@ Number of notches, Reset Method, Key Release Position Code Number of notches, Reset Method, Key Release Position 2ML 2 notches, Manual, Left 2M 2 notches, Manual, Left and Right 2AL 2 notches, Automatic, Left 3ML 3 notches, Manual, Left 3M 3 notches, Manual, Left and Right 3MC 3 notches, Manual, Center 3AC 3 notches, Automatic, Center 3MAL 3 notches, Manual - left, Automatic - right, Left 3AMR 3 notches, Automatic - left, Manual - right, Right Knob Color Code Color Blank Black* Red R G Y Green Yellow A Blue Individual unit (Voltage-reduction unit) A22R-@ A22R--@ A22R--@ Code 17 Contact Form Body unit Code Contact Form 10 1a 01 1b Code Operating Voltage TN AC/DC6V, AC/DC12V, AC/DC24V T2 AC220V* *Use with an A22R-24@LED *Non-lighted type Individual unit (LED) A22R-@ @ LED A22R--@@ Operating Voltage Code Operating Voltage 6A AC/DC6V 12A AC/DC12V 24A AC/DC24V Lighting color Code Lighting color R Red G Y W Green Yellow White A Blue 18 A22R/M22R Series A22R/M22R Series Accessories / Tools Accessories / Tools Items IItems t ems Accessories Accessories Item Standard size Appearance Classification Part No. White A22Z-3321 Red A22Z-3322 With Snap-in Legend Plate (without text) Without Snap-in Legend Plate Large size Red A22Z-3332 Round A22Z-3360 A22Z-3600F Sealing Caps For projection models Connectors A22Z-3600T A22Z-3530 One hole A22Z-B101 Two holes A22Z-B102 Three holes Applicable diameter (mm) Part No. A22Z-3443B Red A22Z-3443R White A22Z-3443W Transparent A22Z-3443C White text on red background A22Z-3443R-2 STOP A22Z-3443R-4 A22Z-3443B-1 START A22Z-3443B-3 ON A22Z-3443B-5 OFF A22Z-3443B-6 UP A22Z-3443B-7 DOWN A22Z-3443B-8 POWER ON A22Z-3443B-9 OFF-ON A22Z-3443B-10 Standard size The Lock Ring is used when more secure lock feature is required. Legend Plates A22Z-3500-1 o9~11 A22Z-3500-2 Attached to the Standard Plate Frame. Material: Acrylic. With text White text on black background Used to prevent dust or water from entering the Operation Unit (Pushbutton, etc.). Color: opaque Material: silicon Can be plugged into pre-cut panel holes for future expansion. The color is black. Large size Black A22Z-3453B Red A22Z-3453R White A22Z-3453W Transparent A22Z-3453C Without text Attached to the Large-size Legend Plate Frame. Material: Acrylic. Material: Polycarbonate resin. No print (Round) A22Z-B103 o7~9 Remarks Black Without text A22Z-3333 A22Z-3330 For flat models Control Boxes Classification Snap-in Legend plate is acrylic. Without Snap-in Legend Plate Round Appearance A22Z-3320 A22Z-3331 Black Hole plug Item A22Z-3323 White With Snap-in Legend Plate (without text) Lock Ring Remarks Snap-in Legend Plate is acrylic. Black Legend Plate Frames 19 Plastic connector used to extend a cable from the Switch Box. (See page 30) Character Films Character Print (Round) A22Z-3460 A22Z-3460-1 A22Z-3460-2 START A22Z-3460-3 STOP A22Z-3460-4 After printing on a film, affix to the indicator Plate of the Lighted Pushbotton Switch. (The back is coated with adhesive.) Tools Item Appearance Part No. Remarks Lamp Extractor A22Z-3901 Rubber tool used to easily replace Lamps. Tightening wrench A22Z-3905 Tool used to tighten nuts from the back of the panel. 18 A22R/M22R Series A22R/M22R Series Accessories / Tools Accessories / Tools Items IItems t ems Accessories Accessories Item Standard size Appearance Classification Part No. White A22Z-3321 Red A22Z-3322 With Snap-in Legend Plate (without text) Without Snap-in Legend Plate Large size Red A22Z-3332 Round A22Z-3360 A22Z-3600F Sealing Caps For projection models Connectors A22Z-3600T A22Z-3530 One hole A22Z-B101 Two holes A22Z-B102 Three holes Applicable diameter (mm) Part No. A22Z-3443B Red A22Z-3443R White A22Z-3443W Transparent A22Z-3443C White text on red background A22Z-3443R-2 STOP A22Z-3443R-4 A22Z-3443B-1 START A22Z-3443B-3 ON A22Z-3443B-5 OFF A22Z-3443B-6 UP A22Z-3443B-7 DOWN A22Z-3443B-8 POWER ON A22Z-3443B-9 OFF-ON A22Z-3443B-10 Standard size The Lock Ring is used when more secure lock feature is required. Legend Plates A22Z-3500-1 o9~11 A22Z-3500-2 Attached to the Standard Plate Frame. Material: Acrylic. With text White text on black background Used to prevent dust or water from entering the Operation Unit (Pushbutton, etc.). Color: opaque Material: silicon Can be plugged into pre-cut panel holes for future expansion. The color is black. Large size Black A22Z-3453B Red A22Z-3453R White A22Z-3453W Transparent A22Z-3453C Without text Attached to the Large-size Legend Plate Frame. Material: Acrylic. Material: Polycarbonate resin. No print (Round) A22Z-B103 o7~9 Remarks Black Without text A22Z-3333 A22Z-3330 For flat models Control Boxes Classification Snap-in Legend plate is acrylic. Without Snap-in Legend Plate Round Appearance A22Z-3320 A22Z-3331 Black Hole plug Item A22Z-3323 White With Snap-in Legend Plate (without text) Lock Ring Remarks Snap-in Legend Plate is acrylic. Black Legend Plate Frames 19 Plastic connector used to extend a cable from the Switch Box. (See page 30) Character Films Character Print (Round) A22Z-3460 A22Z-3460-1 A22Z-3460-2 START A22Z-3460-3 STOP A22Z-3460-4 After printing on a film, affix to the indicator Plate of the Lighted Pushbotton Switch. (The back is coated with adhesive.) Tools Item Appearance Part No. Remarks Lamp Extractor A22Z-3901 Rubber tool used to easily replace Lamps. Tightening wrench A22Z-3905 Tool used to tighten nuts from the back of the panel. 20 A22R/M22R Series A22R/M22R Series Characteristics Specifications C haract erist ics Characteristics Approve Approv e d sstt a n d a r d s Environment Switch unit UL 508/CSA C22.2 No.14 File No. E76675 6A 240VAC/10A 120VAC EN60947-5-1 (low voltage directive) 3A 240VAC (AC-15) UL, cUL EN GB/14048.5-2001 3A 240VAC/1.5A 24VDC CCC Lamp unit UL 508/CSA C22.2 No.14 File No. E76675 24VAC/DC MAX UL, cUL Voltage-reduction unit UL 508/CSA C22.2 No.14 File No. E76675 220VAC GB/14048.5-2001 220VAC UL, cUL CCC Ambient temperature*1 Non-lighted type: -20 to +60C Lighted type: -20 to +50C Ambient humidity -35 to 85%RH Storage temperature*1 -40 to +70C Protective code*2 IP65 Vibration resistance 10 to 55Hz, Double amplitude 1.5mm Shock resistance Non-lighted type: 1,000m/s2 Lighted type: 600m/s2 *1: With no icing or condensation *2: Protection against dust or water from the front of a mounting panel side Operation Operation Indicator UL, cUL UL 508/CSA C22.2 No.14 File No. E76675 12A: 12VAC/DC 24A: 24VAC/DC T2 : 220VAC CCC GB/14048.5-2001 T2 : 220VAC Operating frequency Slow action Mechanical Momentary operation: 60 operations/minute max. Electrical Knob-type and Key-type selector: 30 operations/minute max. Mechanical durability Ratings Momentary switch :3,000,000 operations Alternate, Key/Knob Selector switches: 300,000 operations Electrical Characteristics (Switch block) Contacts Insulation resistance 100M Minimum (At 500VDC) Dielectric strength Between terminals of same polarity: AC2,500V 50/60Hz for 1 minute Between terminals of different polarity: AC2,500V 50/60Hz for 1 minute Rated current values are determined according to the testing conditions. The above ratings were obtained by conducting tests under the following conditions: Ambient temperature: 20+/- 2C Ambient humidity: 65+/-5%RH Operating frequency: 30 operations/minute Rating AC-15, A600, Ue=240V, Ie=3A Rated insulation voltage Ui=600V, Pollution degree: 3 LED (For pushbutton unit) Conditional short-circuit current 10A, IEC60209-1 Electrical durability 500,000 operations Minimum (at AC 240V, 3A, coso=0.4) Rated current (A) 10 21 Rated voltage (V) 240 Inductive load Power facfor 0.4 Rated current (A) 3 Operating voltage Current consumption AC/DC 6V5% AC/DC 12V5% AC/DC 24V5% 20mA 20mA 20mA Operating voltage Current consumption AC/DC 12V5% 20mA AC/DC 24V5% 20mA LED (For indicator unit) Voltage reduction unit (For pushbutton and indicator units) Operating voltage Current consumption AC 200V(190 to 230V) 20mA 20 A22R/M22R Series A22R/M22R Series Characteristics Specifications C haract erist ics Characteristics Approve Approv e d sstt a n d a r d s Environment Switch unit UL 508/CSA C22.2 No.14 File No. E76675 6A 240VAC/10A 120VAC EN60947-5-1 (low voltage directive) 3A 240VAC (AC-15) UL, cUL EN GB/14048.5-2001 3A 240VAC/1.5A 24VDC CCC Lamp unit UL 508/CSA C22.2 No.14 File No. E76675 24VAC/DC MAX UL, cUL Voltage-reduction unit UL 508/CSA C22.2 No.14 File No. E76675 220VAC GB/14048.5-2001 220VAC UL, cUL CCC Ambient temperature*1 Non-lighted type: -20 to +60C Lighted type: -20 to +50C Ambient humidity -35 to 85%RH Storage temperature*1 -40 to +70C Protective code*2 IP65 Vibration resistance 10 to 55Hz, Double amplitude 1.5mm Shock resistance Non-lighted type: 1,000m/s2 Lighted type: 600m/s2 *1: With no icing or condensation *2: Protection against dust or water from the front of a mounting panel side Operation Operation Indicator UL, cUL UL 508/CSA C22.2 No.14 File No. E76675 12A: 12VAC/DC 24A: 24VAC/DC T2 : 220VAC CCC GB/14048.5-2001 T2 : 220VAC Operating frequency Slow action Mechanical Momentary operation: 60 operations/minute max. Electrical Knob-type and Key-type selector: 30 operations/minute max. Mechanical durability Ratings Momentary switch :3,000,000 operations Alternate, Key/Knob Selector switches: 300,000 operations Electrical Characteristics (Switch block) Contacts Insulation resistance 100M Minimum (At 500VDC) Dielectric strength Between terminals of same polarity: AC2,500V 50/60Hz for 1 minute Between terminals of different polarity: AC2,500V 50/60Hz for 1 minute Rated current values are determined according to the testing conditions. The above ratings were obtained by conducting tests under the following conditions: Ambient temperature: 20+/- 2C Ambient humidity: 65+/-5%RH Operating frequency: 30 operations/minute Rating AC-15, A600, Ue=240V, Ie=3A Rated insulation voltage Ui=600V, Pollution degree: 3 LED (For pushbutton unit) Conditional short-circuit current 10A, IEC60209-1 Electrical durability 500,000 operations Minimum (at AC 240V, 3A, coso=0.4) Rated current (A) 10 21 Rated voltage (V) 240 Inductive load Power facfor 0.4 Rated current (A) 3 Operating voltage Current consumption AC/DC 6V5% AC/DC 12V5% AC/DC 24V5% 20mA 20mA 20mA Operating voltage Current consumption AC/DC 12V5% 20mA AC/DC 24V5% 20mA LED (For indicator unit) Voltage reduction unit (For pushbutton and indicator units) Operating voltage Current consumption AC 200V(190 to 230V) 20mA 22 A22R/M22R Series A22R/M22R Series Characteristics Operating Operati n g cha c h a r a ct c t e r i st s t i cs cs Terminal Terminal Arrangement Bottom view (unit: mm) Pushbutton switch (1a1b) Total Travel Force (TTF) 29.4N Maximum Total Travel (TT) 5.5mm Maximum No-lighted (1a1b) 19.8 Lighted Indicator 9.9 10.1 Switch Block Total Travel (TT) 2-notch: approx. 90 degree (3-notch: approx.45 degree) M3.5Screw Releasing Force (RF) Switch Blocks 26.2 Manual reset: 0.34N*m Maximum * Auto-reset 2-notch: 0.25N*m * 3-notch: 0.34N*m * 20.2 Knob-type selector switch (1a1b) Total Travel Force (TTF) Lamp Socket Manual reset: 0.34N*m Maximum * * Rotation torque for knob type/key type selector switches. Key-type selector switch (1a1b) Total Travel Force (TTF) Manual reset: 0.34N*m Maximum * Auto-reset 2-notch: 0.25N*m * 3-notch: 0.34N*m * Total Travel (TT) 2-notch: approx. 90 degree (3-notch: approx.45 degree) Releasing Force (RF) Manual reset: 0.34N*m Maximum * 23 Terminal connection connect ion Type Terminal connection BOTTOM VIEW Non-lighted (1a1b) 1 3 2 4 * Rotation torque for knob type/key type selector switches. BOTTOM VIEW 1 3 X1 Lighted without voltage reduction unit (1a1b) x 2 4 X2 * LED: For AC/DC BOTTOM VIEW 1 3 X1 Lighted with voltage reduction unit (1a1b) x 2 X2 4 22 A22R/M22R Series A22R/M22R Series Characteristics Operating Operati n g cha c h a r a ct c t e r i st s t i cs cs Terminal Terminal Arrangement Bottom view (unit: mm) Pushbutton switch (1a1b) Total Travel Force (TTF) 29.4N Maximum Total Travel (TT) 5.5mm Maximum No-lighted (1a1b) 19.8 Lighted Indicator 9.9 10.1 Switch Block Total Travel (TT) 2-notch: approx. 90 degree (3-notch: approx.45 degree) M3.5Screw Releasing Force (RF) Switch Blocks 26.2 Manual reset: 0.34N*m Maximum * Auto-reset 2-notch: 0.25N*m * 3-notch: 0.34N*m * 20.2 Knob-type selector switch (1a1b) Total Travel Force (TTF) Lamp Socket Manual reset: 0.34N*m Maximum * * Rotation torque for knob type/key type selector switches. Key-type selector switch (1a1b) Total Travel Force (TTF) Manual reset: 0.34N*m Maximum * Auto-reset 2-notch: 0.25N*m * 3-notch: 0.34N*m * Total Travel (TT) 2-notch: approx. 90 degree (3-notch: approx.45 degree) Releasing Force (RF) Manual reset: 0.34N*m Maximum * 23 Terminal connection connect ion Type Terminal connection BOTTOM VIEW Non-lighted (1a1b) 1 3 2 4 * Rotation torque for knob type/key type selector switches. BOTTOM VIEW 1 3 X1 Lighted without voltage reduction unit (1a1b) x 2 4 X2 * LED: For AC/DC BOTTOM VIEW 1 3 X1 Lighted with voltage reduction unit (1a1b) x 2 X2 4 24 A22R/M22R Series A22R/M22R Series Precautions 25 Precautions Precauti Prec aution ons Precaut ions Precautions Warning Do not wire and/or touch the switch terminal while power is supplied to the switch to avoid electric shock. Correct Use Mounting * Always make sure that the power is turned OFF before mounting, removing, or wiring the Switch, or performing maintenance. * Do not tighten the mounting ring more than necessary using tools such as pointed-nose pliers. Doing so will damage the mounting ring. The tightening torque is 0.98 to 1.96N*m. * Recommended panel thickness: 1 to 5 mm. Wiring * Terminal screws must be Phillips with a square washer. * The tightening torque is 1.08 to 1.27N*m. * Single wires, stranded wires and crimp terminals except round type can be connected to the Switch. * Applicable Wire Size Strand wire: 2mm2 Maximum Solid wire: 1.6mm diameter Maximum Bare Crimp Terminals Operational Environment * The IP65 model is designed with a degree of protection so that it will not sustain damage if it is subject to water from any direction to front of the panel. * This Switch is indoor use only. Outdoor use of the Switch will cause operation failure of the Switch. * Do not use the Switch in the water, oil, or in locations where water, oils, detergent, chemicals, or solvent is applied to the Switch always. Otherwise, switching failure will be happened. * Do not use the Switch under the environmental condition where corrosive gas (ammonia, chlorine, dioxide sulfur...etc.) is generated. Otherwise, the Switch will corrode. * Do not use the Switch in locations where dust, metal or plastic dust exists. Dust will accumulate o the Switch, and then the Switch wouldn't operate normally. * Do not use the Switch under the environmental condition where excessive vibration or shock exists. Otherwise, incorrect switching would occur. Electrical Conditions * The switching load capacity of the Switch greatly varies between AC and DC. Always be sure to apply the rated load. The control capacity will drastically drop if it is a DC load. This is because a DC load has no current zero-cross point, unlike an AC load. Therefore, if an arc is generated, it may continue for a comparatively long time. Furthermore, the current direction is always the same, which results in a contact relocation phenomena whereby the contacts easily stick to each other and do not separate when the surfaces of the contacts are uneven. * Some types of load have a great difference between normal current and inrush current. Make sure that the inrush current is within the permissible value. The greater the inrush current in the closed circuit is, the greater the contact abrasion or shift will be. Consequently, contact weld, contact separation failures, or insulation failures may result. Furthermore, the Switch may be broken or damaged. * If the load is inductive, counter-electromotive voltage will be generated. The higher the voltage is, the higher the generated energy will be, which increase the abrasion of the contacts and contact relocation phenomena. Be sure to use the Switch within the rated conditions. I (A) 8mm max. Solenoid (Approximately 10 to 20 times higher) Incandescent lamp (Approximately 10 to 15 times higher) 16.0mm max. i Crimp Terminal with Insulating Sheath 8mm max. Relay (Approximately 4 to 5 times higher) 20.2mm max. o (Steady current) (Time) t * Before using the Switch, be sure to test the Switch under actual conditions. * This product is a standard load type Switch. Using the Switch for opening and closing a microload circuit may cause contact failure. Use the Switch within the operating range as shown in below chart. Voltage (V) * Secure appropriate insulation distance after wiring of the Switch. * Perform wiring so that the lead wires will not be caught on other objects as this will cause stress on the Switch terminals. Wire the Switch so that there is slack in the lead wires and fix lead wires at intermediate points. If the panel to which the Switch is mounted needs to be opened and closed for maintenance purpose, perform wiring so that the opening and closing of the panel will not interfere with the wiring. 0.16mA 1.6mA 100mA 30 24 Microload area Standard load area 12 Invalid area 5 0 0.1 1mA 10mA 1 10 Mechanical Conditions * Do not use the Switch for loads that exceed the rated switching capacity or other contact ratings. Doing so may result in contact weld, separation failure, or insulation failures. Furthermore, the Switch may be broken or damaged. * Do not touch the charged switch terminals while power is supplied, otherwise an electric shock may be received. * The life of the Switch varies greatly with switching conditions. Before using the Switch, be sure to test the Switch under actual conditions. Make sure that the number of switching operations is within the permissible range. If a deteriorated Switch is used continuously, insulation failures, contact weld, contact failures, switch damage, or switch burnout may result. * Do not apply excessive or incorrect voltages to the Switch or incorrectly wire the terminals. Otherwise, the Switch may not function properly and have an adverse effect on external circuitry. Furthermore, the Switch itself may become damaged or burnt. * Do not use the Switch in locations where flammable or explosive gasses are present. Otherwise switching arcs or heat radiation may cause a fire or explosion. * Do not drop or disassemble the Switch, otherwise it may not be capable of full performance. Furthermore, it may be broken or burnt. * Operating the Switch using a hard object (e.g., metal), or with a large or sudden force, may deform or damage the Switch, resulting in faulty or rough operation, or shortening of the Switch life. 100 1,000 Current (mA) * When use the Switch for opening and closing a microload or large-load, use the Switch with an appropriate relay. Hammer Do not apply excessive or sudden force. * The pushbutton surface is composed of resin. Therefore, do not attempt to operate the pushbutton using a sharp object, such as a screwdriver or a pair of tweezers. Also, do not drop, throw, or knock the Switch. Doing so may damage or deform the pushbutton surface and result in faulty operation. Do not use sharp objects. LED * The LED current-limiting resistor is built-in, so internal resistance is not required. * If commercially available LEDs are used, select the ones that meet the following conditions: Base: BA9S/13@ Overall length: 26mm Maximum Power consumption: 2.6 W Maximum Storage Motor (Approximately 5 to 10 times higher) (Current) Switching * When the Switch is left unused or stored for long periods, the ambient conditions can have a great effect on the condition of the Switch. In certain environments, leaving the Switch exposed may result I deterioration (i.e., oxidation, or the creation of an oxide film) of the contacts and terminals, causing the contact resistance to increase, and making it difficult to solder the lead wires. Therefore, store in a well-ventilated room, inside, for example, a non-hygroscopic case, in a location where no corrosive gasses are present. * If the Switch is stored in a location where it will be exposed to direct light, colored resin in the colored plate may fade. Therefore, do not store the Switch I locations where it will be exposed to direct light. Screwdriver Tweezers * Periodic maintenance is required to use the Switch stably. 24 A22R/M22R Series A22R/M22R Series Precautions 25 Precautions Precauti Prec aution ons Precaut ions Precautions Warning Do not wire and/or touch the switch terminal while power is supplied to the switch to avoid electric shock. Correct Use Mounting * Always make sure that the power is turned OFF before mounting, removing, or wiring the Switch, or performing maintenance. * Do not tighten the mounting ring more than necessary using tools such as pointed-nose pliers. Doing so will damage the mounting ring. The tightening torque is 0.98 to 1.96N*m. * Recommended panel thickness: 1 to 5 mm. Wiring * Terminal screws must be Phillips with a square washer. * The tightening torque is 1.08 to 1.27N*m. * Single wires, stranded wires and crimp terminals except round type can be connected to the Switch. * Applicable Wire Size Strand wire: 2mm2 Maximum Solid wire: 1.6mm diameter Maximum Bare Crimp Terminals Operational Environment * The IP65 model is designed with a degree of protection so that it will not sustain damage if it is subject to water from any direction to front of the panel. * This Switch is indoor use only. Outdoor use of the Switch will cause operation failure of the Switch. * Do not use the Switch in the water, oil, or in locations where water, oils, detergent, chemicals, or solvent is applied to the Switch always. Otherwise, switching failure will be happened. * Do not use the Switch under the environmental condition where corrosive gas (ammonia, chlorine, dioxide sulfur...etc.) is generated. Otherwise, the Switch will corrode. * Do not use the Switch in locations where dust, metal or plastic dust exists. Dust will accumulate o the Switch, and then the Switch wouldn't operate normally. * Do not use the Switch under the environmental condition where excessive vibration or shock exists. Otherwise, incorrect switching would occur. Electrical Conditions * The switching load capacity of the Switch greatly varies between AC and DC. Always be sure to apply the rated load. The control capacity will drastically drop if it is a DC load. This is because a DC load has no current zero-cross point, unlike an AC load. Therefore, if an arc is generated, it may continue for a comparatively long time. Furthermore, the current direction is always the same, which results in a contact relocation phenomena whereby the contacts easily stick to each other and do not separate when the surfaces of the contacts are uneven. * Some types of load have a great difference between normal current and inrush current. Make sure that the inrush current is within the permissible value. The greater the inrush current in the closed circuit is, the greater the contact abrasion or shift will be. Consequently, contact weld, contact separation failures, or insulation failures may result. Furthermore, the Switch may be broken or damaged. * If the load is inductive, counter-electromotive voltage will be generated. The higher the voltage is, the higher the generated energy will be, which increase the abrasion of the contacts and contact relocation phenomena. Be sure to use the Switch within the rated conditions. I (A) 8mm max. Solenoid (Approximately 10 to 20 times higher) Incandescent lamp (Approximately 10 to 15 times higher) 16.0mm max. i Crimp Terminal with Insulating Sheath 8mm max. Relay (Approximately 4 to 5 times higher) 20.2mm max. o (Steady current) (Time) t * Before using the Switch, be sure to test the Switch under actual conditions. * This product is a standard load type Switch. Using the Switch for opening and closing a microload circuit may cause contact failure. Use the Switch within the operating range as shown in below chart. Voltage (V) * Secure appropriate insulation distance after wiring of the Switch. * Perform wiring so that the lead wires will not be caught on other objects as this will cause stress on the Switch terminals. Wire the Switch so that there is slack in the lead wires and fix lead wires at intermediate points. If the panel to which the Switch is mounted needs to be opened and closed for maintenance purpose, perform wiring so that the opening and closing of the panel will not interfere with the wiring. 0.16mA 1.6mA 100mA 30 24 Microload area Standard load area 12 Invalid area 5 0 0.1 1mA 10mA 1 10 Mechanical Conditions * Do not use the Switch for loads that exceed the rated switching capacity or other contact ratings. Doing so may result in contact weld, separation failure, or insulation failures. Furthermore, the Switch may be broken or damaged. * Do not touch the charged switch terminals while power is supplied, otherwise an electric shock may be received. * The life of the Switch varies greatly with switching conditions. Before using the Switch, be sure to test the Switch under actual conditions. Make sure that the number of switching operations is within the permissible range. If a deteriorated Switch is used continuously, insulation failures, contact weld, contact failures, switch damage, or switch burnout may result. * Do not apply excessive or incorrect voltages to the Switch or incorrectly wire the terminals. Otherwise, the Switch may not function properly and have an adverse effect on external circuitry. Furthermore, the Switch itself may become damaged or burnt. * Do not use the Switch in locations where flammable or explosive gasses are present. Otherwise switching arcs or heat radiation may cause a fire or explosion. * Do not drop or disassemble the Switch, otherwise it may not be capable of full performance. Furthermore, it may be broken or burnt. * Operating the Switch using a hard object (e.g., metal), or with a large or sudden force, may deform or damage the Switch, resulting in faulty or rough operation, or shortening of the Switch life. 100 1,000 Current (mA) * When use the Switch for opening and closing a microload or large-load, use the Switch with an appropriate relay. Hammer Do not apply excessive or sudden force. * The pushbutton surface is composed of resin. Therefore, do not attempt to operate the pushbutton using a sharp object, such as a screwdriver or a pair of tweezers. Also, do not drop, throw, or knock the Switch. Doing so may damage or deform the pushbutton surface and result in faulty operation. Do not use sharp objects. LED * The LED current-limiting resistor is built-in, so internal resistance is not required. * If commercially available LEDs are used, select the ones that meet the following conditions: Base: BA9S/13@ Overall length: 26mm Maximum Power consumption: 2.6 W Maximum Storage Motor (Approximately 5 to 10 times higher) (Current) Switching * When the Switch is left unused or stored for long periods, the ambient conditions can have a great effect on the condition of the Switch. In certain environments, leaving the Switch exposed may result I deterioration (i.e., oxidation, or the creation of an oxide film) of the contacts and terminals, causing the contact resistance to increase, and making it difficult to solder the lead wires. Therefore, store in a well-ventilated room, inside, for example, a non-hygroscopic case, in a location where no corrosive gasses are present. * If the Switch is stored in a location where it will be exposed to direct light, colored resin in the colored plate may fade. Therefore, do not store the Switch I locations where it will be exposed to direct light. Screwdriver Tweezers * Periodic maintenance is required to use the Switch stably. A22R/M22R Series A22R/M22R Series Installation Installation Mounting Mounti ng t o t h e P an anel Panel Hole Dimensions * The cutout dimensions are as shown in below: When Lock Ring is not used. When Lock Ring is used. * Recommended panel thickness is 1 to 5mm. * In outer surface treatment such as coating is performed for the panel, the panel dimensions after outer surface treatment must meet the specified panel dimensions. Matrix Installation (1) The following panel hole (2) dimensions apply when Switch Unit and the Standard-size Legend Plate Frame and Lock Ring are mounted, and lead wires are connected directly to the Switch Block. The following panel hole dimensions apply when the Large-size Legend Plate Frame is mounted, and when crimp terminals are connected to the Switch Block terminals. How H ow to t o confirm conf irm the t he Lever Position, Posit ion, OPEN or LOC K Mounting the Operation Unit on the Panel * Insert the Operation Unit (Pushbutton, etc.) from the front surface of the panel, insert the Lock Ring and the mounting nut from the terminal side, then tighten the nut. Before tightening, check that the rubber washer is present between the Pushbutton Unit and the panel. * When using a Legend Plate Frame, put one rubber washer each between the Legend Plate Frame and the panel and between the Operation Unit and the Legend Plate Frame. (One rubber washer will be provided when one Legend Plate Frame is ordered.) * Align the Lock Ring with the groove in the casing, then insert the Lock Ring so that its edge is located on the panel side. * Tighten the mounting nut at a torque of 0.98 to 1.96N*m. * When using a Lock Ring, replace with the supplied Lock Ring, insert the projecting part into the lock slot, and then tighten the mounting nut. Hold here Rubber washer Mounting nut The Lever Position, OPEN (Operation unit is not fixed)/LOCK (Operation unit is fixed), can be confirmed from the Switch terminal side. Left side Right side In case that no switch block is mounted on the mounting plate No.1. Two holes One hole Panel (OPEN condition) Panel Projection part (LOCK condition) Lock Ring Panel Mounting the Switch on the Pushbutton Unit * Insert the Pushbutton Unit into the Switch Unit, aligning the arrow mark inscribed on the Case with the lever on the Switch Blocks, then move the lever in the direction indicated by the arrow in the following figure. In case that a switch block is mounted on the mounting plate No.1. Left side Right side Two holes Hole is not shown Operation Unit 45 min. Arrow mark (OPEN condition) Lever Type of crimp terminal Dimension A Bare crimp terminals 51 mm Minimum Crimp terminals with insulating sheath 60 mm Minimum Note: The above dimensions are the minimum dimensions for when the wires described under "Applicable Wire Size". If a different wires are used, the wiring dimensions may be different so determine an appropriate pitch before setup. Removing the Switch * Move the lever in the direction indicated by the arrow in the following figure, then pull the Pushbutton Unit or the Switch Blocks. * Since the lever has a hole with an inside diameter of 6.5mm, the lever can be moved in the specified direction by inserting a screwdriver into the hole and then moving the screwdriver. Screwdriver In case that a switch block is mounted on the mounting plate No.1 and an indicator unit is mounted on the mounting plate No.2. Left side (LOCK condition) Right side One hole Hole is not shown (OPEN condition) (LOCK condition) A22R/M22R Series A22R/M22R Series Installation Installation Mounting Mounti ng t o t h e P an anel Panel Hole Dimensions * The cutout dimensions are as shown in below: When Lock Ring is not used. When Lock Ring is used. * Recommended panel thickness is 1 to 5mm. * In outer surface treatment such as coating is performed for the panel, the panel dimensions after outer surface treatment must meet the specified panel dimensions. Matrix Installation (1) The following panel hole (2) dimensions apply when Switch Unit and the Standard-size Legend Plate Frame and Lock Ring are mounted, and lead wires are connected directly to the Switch Block. The following panel hole dimensions apply when the Large-size Legend Plate Frame is mounted, and when crimp terminals are connected to the Switch Block terminals. How H ow to t o confirm conf irm the t he Lever Position, Posit ion, OPEN or LOC K Mounting the Operation Unit on the Panel * Insert the Operation Unit (Pushbutton, etc.) from the front surface of the panel, insert the Lock Ring and the mounting nut from the terminal side, then tighten the nut. Before tightening, check that the rubber washer is present between the Pushbutton Unit and the panel. * When using a Legend Plate Frame, put one rubber washer each between the Legend Plate Frame and the panel and between the Operation Unit and the Legend Plate Frame. (One rubber washer will be provided when one Legend Plate Frame is ordered.) * Align the Lock Ring with the groove in the casing, then insert the Lock Ring so that its edge is located on the panel side. * Tighten the mounting nut at a torque of 0.98 to 1.96N*m. * When using a Lock Ring, replace with the supplied Lock Ring, insert the projecting part into the lock slot, and then tighten the mounting nut. Hold here Rubber washer Mounting nut The Lever Position, OPEN (Operation unit is not fixed)/LOCK (Operation unit is fixed), can be confirmed from the Switch terminal side. Left side Right side In case that no switch block is mounted on the mounting plate No.1. Two holes One hole Panel (OPEN condition) Panel Projection part (LOCK condition) Lock Ring Panel Mounting the Switch on the Pushbutton Unit * Insert the Pushbutton Unit into the Switch Unit, aligning the arrow mark inscribed on the Case with the lever on the Switch Blocks, then move the lever in the direction indicated by the arrow in the following figure. In case that a switch block is mounted on the mounting plate No.1. Left side Right side Two holes Hole is not shown Operation Unit 45 min. Arrow mark (OPEN condition) Lever Type of crimp terminal Dimension A Bare crimp terminals 51 mm Minimum Crimp terminals with insulating sheath 60 mm Minimum Note: The above dimensions are the minimum dimensions for when the wires described under "Applicable Wire Size". If a different wires are used, the wiring dimensions may be different so determine an appropriate pitch before setup. Removing the Switch * Move the lever in the direction indicated by the arrow in the following figure, then pull the Pushbutton Unit or the Switch Blocks. * Since the lever has a hole with an inside diameter of 6.5mm, the lever can be moved in the specified direction by inserting a screwdriver into the hole and then moving the screwdriver. Screwdriver In case that a switch block is mounted on the mounting plate No.1 and an indicator unit is mounted on the mounting plate No.2. Left side (LOCK condition) Right side One hole Hole is not shown (OPEN condition) (LOCK condition) 28 29 A22R/M22R Series A22R/M22R Series Installation Installation Mounting e p l aci a c i ng n g t h e Co Color Cap Mounti ng / R ep lo r Ca p Mounting/Replacing Mount ing/ R eplacing the t he Switch Sw it ch Unit U nit and Indicator I ndicat or Unit Installing the Switch Blocks Projection type Removing the Switch Base * Mount the Unit according to the indicate numbers on the Mounting Plate. * Grip and rotate the Color Cap with your fingers. No. on the Mounting Plate * Insert a screwdriver between the Mounting Latch and the Switch Block, then push down the screwdriver in the direction indicated by the arrow in the following figure. Flat-head screwdriver Switch Unit (A22R-10/A22R-01) Assembl As s embl i n g t h e C a ap p Projection type Lighted Pushbutton Switch * Mount the Color Cap so that the protrusions inside the cap fit into the grooves in the Pushbutton Unit. Indicator Unit (A22R-TN/A22R-T2) Indicator * Mount the Color Cap so that the protrusions inside the Pushbutton Unit fit into the grooves in the cap. Protrusion part Protrusion parts on the Cap * Hook the small protrusion on the Switch Block into the groove on the Mounting Latch on the other side of the lever, then push up the Switch Block in the direction indicated by the arrow in the figure below: * One more Switch Block can be mounted. Grooves Reflector Mounting Latch Lever Color Cap Color Cap Switch Block Installin e p l aci a c i ng ng the L LED Ins tallin g / R ep ED Installing/Replacing from the Panel Surface * Insert the Lamp Extractor(A22Z-3901) into the lamp, then rotate the Extractor while pressing it. Protrusion Protrusion Installing/Replacing on the Switch * Grip the lamp with your fingers, then rotate the lamp while pressing it against the Switch. Switch Block Note: In case that two Switch Block are mounted, a Control Box cannot be used. 3mm Maximum Use the following screwdrivers. 28 29 A22R/M22R Series A22R/M22R Series Installation Installation Mounting e p l aci a c i ng n g t h e Co Color Cap Mounti ng / R ep lo r Ca p Mounting/Replacing Mount ing/ R eplacing the t he Switch Sw it ch Unit U nit and Indicator I ndicat or Unit Installing the Switch Blocks Projection type Removing the Switch Base * Mount the Unit according to the indicate numbers on the Mounting Plate. * Grip and rotate the Color Cap with your fingers. No. on the Mounting Plate * Insert a screwdriver between the Mounting Latch and the Switch Block, then push down the screwdriver in the direction indicated by the arrow in the following figure. Flat-head screwdriver Switch Unit (A22R-10/A22R-01) Assembl As s embl i n g t h e C a ap p Projection type Lighted Pushbutton Switch * Mount the Color Cap so that the protrusions inside the cap fit into the grooves in the Pushbutton Unit. Indicator Unit (A22R-TN/A22R-T2) Indicator * Mount the Color Cap so that the protrusions inside the Pushbutton Unit fit into the grooves in the cap. Protrusion part Protrusion parts on the Cap * Hook the small protrusion on the Switch Block into the groove on the Mounting Latch on the other side of the lever, then push up the Switch Block in the direction indicated by the arrow in the figure below: * One more Switch Block can be mounted. Grooves Reflector Mounting Latch Lever Color Cap Color Cap Switch Block Installin e p l aci a c i ng ng the L LED Ins tallin g / R ep ED Installing/Replacing from the Panel Surface * Insert the Lamp Extractor(A22Z-3901) into the lamp, then rotate the Extractor while pressing it. Protrusion Protrusion Installing/Replacing on the Switch * Grip the lamp with your fingers, then rotate the lamp while pressing it against the Switch. Switch Block Note: In case that two Switch Block are mounted, a Control Box cannot be used. 3mm Maximum Use the following screwdrivers. 30 31 A22R/M22R Series A22R/M22R Series Installation Installation Control B ox ox Engraving Mounting the Switch Creating a Cable Port Hole The Standard-size Legend Plate Frame can be mounted. Mount the Switch in the same way as for an ordinary panel. Snap-in Legend Plate Place the tip of a screwdriver on the surface where the cable port hole is to be created with the cover attached and strike the screwdriver to punch a hole. Attempts to punch a hole on the other side of the case will damage the Box. Mounting and Dismounting Snap-in Legend * Engrave the characters on the surface on the Cap. Make sure that the characters are aligned parallel to the imaginary lie connecting the two protruding portions to the left and right of the Cap. * The characters must not be engraved deeper than 0.5mm. Apply an alcohol-based paint coating, such as melamine, alkyd, or acrylic resin paint coating, to the engraved characters. * Press and secure the Snap-in Legend Plate onto the Legend Plate Frame. * The direction of the characters will vary with the mounting direction of the control panel if the Switch is a knob or key selector model. Legend Plate Frame Protruding portions of the Cap Screwdriver Side Snap-in Legend Plate Cover Switch box Concave surface Cable port hole Strike the screwdriver to punch a hole by place 4 parts diagonally. Groove Material: Acrylic Securing the Connector Cable Insert the connector into the cable port in the Box and secure with the fixing nut inside the box. Open a hole in the thin rubber section of the rubber ring. Pass the tightening cap through the cable, insert the cable into the connector, and tighten the hexagonal nut to secure the cable. Fixing nut Rubber washer Connector Cable diameter (mm) Connector 7 to 9 mm dia. A22Z-3500-1 Tightening cap Cable 9 to 11 mm dia. A22Z-3500-2 * Engrave the characters directly on the matted side of the Snap-in Legend Plate. * The characters must be engraved no deeper than 0.5mm. * Apply alcohol-based paint coating to the engraved characters. * If the Snap-in Legend Plate is transparent, engrave the mirror-written characters on the back of the Snap-in Legend Plate and apply paint coating of a different color to the remaining part of the Snap-in Legend Plate. * To easily remove the Snap-in Legend Plate from the Legend Plate Frame mounted to the panel. Insert a Tool with a thin tip into the space between the Snap-in Legend Plate and the Legend Plate Frame. Affixing Character Film * Hold the Cap, remove the cardboard o the Film, and attach the Film to the Cap. Make sure that the protruding portions of the Cap engage the cutout portions of the Film and that the characters are aligned parallel to the imaginary line connecting the two protruding portions to the left and right of the Cap. * The Snap-in Legend Plate is easily removed by pressing the Snap-I Legend Plate from the back of the Legend Plate Frame. * The Legend Plate Frame is made of acrylic resin, which is easily damaged by shock. Be sure to handle the Legend Plate Frame with care. Remove the cardboard. Inside Outside Box Protruding portions on Cap Precautions ions w when Precaut hen use tthe he IIndicators ndicat ors * Lock Ring (A22Z-3360) cannot be used. * When use the Legend Plate Frames (A22Z-332@, A22Z-333@) cut the projection portions shown in the below fig. * When use the Control Box (A22Z-B10@), cut the projection portions shown in the below fig. Cut the projection portions Cut the projection portions 30 31 A22R/M22R Series A22R/M22R Series Installation Installation Control B ox ox Engraving Mounting the Switch Creating a Cable Port Hole The Standard-size Legend Plate Frame can be mounted. Mount the Switch in the same way as for an ordinary panel. Snap-in Legend Plate Place the tip of a screwdriver on the surface where the cable port hole is to be created with the cover attached and strike the screwdriver to punch a hole. Attempts to punch a hole on the other side of the case will damage the Box. Mounting and Dismounting Snap-in Legend * Engrave the characters on the surface on the Cap. Make sure that the characters are aligned parallel to the imaginary lie connecting the two protruding portions to the left and right of the Cap. * The characters must not be engraved deeper than 0.5mm. Apply an alcohol-based paint coating, such as melamine, alkyd, or acrylic resin paint coating, to the engraved characters. * Press and secure the Snap-in Legend Plate onto the Legend Plate Frame. * The direction of the characters will vary with the mounting direction of the control panel if the Switch is a knob or key selector model. Legend Plate Frame Protruding portions of the Cap Screwdriver Side Snap-in Legend Plate Cover Switch box Concave surface Cable port hole Strike the screwdriver to punch a hole by place 4 parts diagonally. Groove Material: Acrylic Securing the Connector Cable Insert the connector into the cable port in the Box and secure with the fixing nut inside the box. Open a hole in the thin rubber section of the rubber ring. Pass the tightening cap through the cable, insert the cable into the connector, and tighten the hexagonal nut to secure the cable. Fixing nut Rubber washer Connector Cable diameter (mm) Connector 7 to 9 mm dia. A22Z-3500-1 Tightening cap Cable 9 to 11 mm dia. A22Z-3500-2 * Engrave the characters directly on the matted side of the Snap-in Legend Plate. * The characters must be engraved no deeper than 0.5mm. * Apply alcohol-based paint coating to the engraved characters. * If the Snap-in Legend Plate is transparent, engrave the mirror-written characters on the back of the Snap-in Legend Plate and apply paint coating of a different color to the remaining part of the Snap-in Legend Plate. * To easily remove the Snap-in Legend Plate from the Legend Plate Frame mounted to the panel. Insert a Tool with a thin tip into the space between the Snap-in Legend Plate and the Legend Plate Frame. Affixing Character Film * Hold the Cap, remove the cardboard o the Film, and attach the Film to the Cap. Make sure that the protruding portions of the Cap engage the cutout portions of the Film and that the characters are aligned parallel to the imaginary line connecting the two protruding portions to the left and right of the Cap. * The Snap-in Legend Plate is easily removed by pressing the Snap-I Legend Plate from the back of the Legend Plate Frame. * The Legend Plate Frame is made of acrylic resin, which is easily damaged by shock. Be sure to handle the Legend Plate Frame with care. Remove the cardboard. Inside Outside Box Protruding portions on Cap Precautions ions w when Precaut hen use tthe he IIndicators ndicat ors * Lock Ring (A22Z-3360) cannot be used. * When use the Legend Plate Frames (A22Z-332@, A22Z-333@) cut the projection portions shown in the below fig. * When use the Control Box (A22Z-B10@), cut the projection portions shown in the below fig. Cut the projection portions Cut the projection portions Terms and Conditions of Sale 1. Offer; Acceptance. These terms and conditions (these "Terms") are deemed part of all quotes, agreements, purchase orders, acknowledgments, price lists, catalogs, manuals, brochures and other documents, whether electronic or in writing, relating to the sale of products or services (collectively, the "Products") by Omron Electronics LLC and its subsidiary companies ("Omron"). Omron objects to any terms or conditions proposed in Buyer's purchase order or other documents which are inconsistent with, or in addition to, these Terms. 2. Prices; Payment Terms. All prices stated are current, subject to change without notice by Omron. Omron reserves the right to increase or decrease prices on any unshipped portions of outstanding orders. Payments for Products are due net 30 days unless otherwise stated in the invoice. 3. Discounts. Cash discounts, if any, will apply only on the net amount of invoices sent to Buyer after deducting transportation charges, taxes and duties, and will be allowed only if (i) the invoice is paid according to Omron's payment terms and (ii) Buyer has no past due amounts. 4. Interest. Omron, at its option, may charge Buyer 1-1/2% interest per month or the maximum legal rate, whichever is less, on any balance not paid within the stated terms. 5. Orders. Omron will accept no order less than $200 net billing. 6. Governmental Approvals. Buyer shall be responsible for, and shall bear all costs involved in, obtaining any government approvals required for the importation or sale of the Products. 7. Taxes. All taxes, duties and other governmental charges (other than general real property and income taxes), including any interest or penalties thereon, imposed directly or indirectly on Omron or required to be collected directly or indirectly by Omron for the manufacture, production, sale, delivery, importation, consumption or use of the Products sold hereunder (including customs duties and sales, excise, use, turnover and license taxes) shall be charged to and remitted by Buyer to Omron. 8. Financial. If the financial position of Buyer at any time becomes unsatisfactory to Omron, Omron reserves the right to stop shipments or require satisfactory security or payment in advance. If Buyer fails to make payment or otherwise comply with these Terms or any related agreement, Omron may (without liability and in addition to other remedies) cancel any unshipped portion of Products sold hereunder and stop any Products in transit until Buyer pays all amounts, including amounts payable hereunder, whether or not then due, which are owing to it by Buyer. Buyer shall in any event remain liable for all unpaid accounts. 9. Cancellation; Etc. Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Omron against all related costs or expenses. 10. Force Majeure. Omron shall not be liable for any delay or failure in delivery resulting from causes beyond its control, including earthquakes, fires, floods, strikes or other labor disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots, delay in or lack of transportation or the requirements of any government authority. 11. Shipping; Delivery. Unless otherwise expressly agreed in writing by Omron: a. Shipments shall be by a carrier selected by Omron; Omron will not drop ship except in "break down" situations. b. Such carrier shall act as the agent of Buyer and delivery to such carrier shall constitute delivery to Buyer; c. All sales and shipments of Products shall be FOB shipping point (unless otherwise stated in writing by Omron), at which point title and risk of loss shall pass from Omron to Buyer; provided that Omron shall retain a security interest in the Products until the full purchase price is paid; d. Delivery and shipping dates are estimates only; and e. Omron will package Products as it deems proper for protection against normal handling and extra charges apply to special conditions. 12. Claims. Any claim by Buyer against Omron for shortage or damage to the Products occurring before delivery to the carrier must be presented in writing to Omron within 30 days of receipt of shipment and include the original transportation bill signed by the carrier noting that the carrier received the Products from Omron in the condition claimed. 13. Warranties. (a) Exclusive Warranty. Omron's exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABIL- 14. 15. 16. 17. 18. ITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron's sole obligation hereunder shall be, at Omron's election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron's analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron247.com or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Indemnities. Buyer shall indemnify and hold harmless Omron Companies and their employees from and against all liabilities, losses, claims, costs and expenses (including attorney's fees and expenses) related to any claim, investigation, litigation or proceeding (whether or not Omron is a party) which arises or is alleged to arise from Buyer's acts or omissions under these Terms or in any way with respect to the Products. Without limiting the foregoing, Buyer (at its own expense) shall indemnify and hold harmless Omron and defend or settle any action brought against such Companies to the extent based on a claim that any Product made to Buyer specifications infringed intellectual property rights of another party. Property; Confidentiality. Any intellectual property in the Products is the exclusive property of Omron Companies and Buyer shall not attempt to duplicate it in any way without the written permission of Omron. Notwithstanding any charges to Buyer for engineering or tooling, all engineering and tooling shall remain the exclusive property of Omron. All information and materials supplied by Omron to Buyer relating to the Products are confidential and proprietary, and Buyer shall limit distribution thereof to its trusted employees and strictly prevent disclosure to any third party. Export Controls. Buyer shall comply with all applicable laws, regulations and licenses regarding (i) export of products or information; (iii) sale of products to "forbidden" or other proscribed persons; and (ii) disclosure to non-citizens of regulated technology or information. Miscellaneous. (a) Waiver. No failure or delay by Omron in exercising any right and no course of dealing between Buyer and Omron shall operate as a waiver of rights by Omron. (b) Assignment. Buyer may not assign its rights hereunder without Omron's written consent. (c) Law. These Terms are governed by the law of the jurisdiction of the home office of the Omron company from which Buyer is purchasing the Products (without regard to conflict of law principles). (d) Amendment. These Terms constitute the entire agreement between Buyer and Omron relating to the Products, and no provision may be changed or waived unless in writing signed by the parties. (e) Severability. If any provision hereof is rendered ineffective or invalid, such provision shall not invalidate any other provision. (f) Setoff. Buyer shall have no right to set off any amounts against the amount owing in respect of this invoice. (g) Definitions. As used herein, "including" means "including without limitation"; and "Omron Companies" (or similar words) mean Omron Corporation and any direct or indirect subsidiary or affiliate thereof. Certain Precautions on Specifications and Use 1. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer's application or use of the Product. At Buyer's request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer's application, product or system. Buyer shall take application responsibility in all cases but the following is a non-exhaustive list of applications for which particular attention must be given: (i) Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document. (ii) Use in consumer products or any use in significant quantities. (iii) Energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. (iv) Systems, machines and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to this Product. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO 2. 3. 4. 5. ADDRESS THE RISKS, AND THAT THE OMRON'S PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user's programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron's test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron's Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron's representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. OMRON INDUSTRIAL AUTOMATION * THE AMERICAS HEADQUARTERS * Schaumburg, IL USA * 847.843.7900 * 800.556.6766 * www.omron247.com OMRON CANADA, INC. * HEAD OFFICE Toronto, ON, Canada * 416.286.6465 * 866.986.6766 * www.omron247.com OMRON ARGENTINA * SALES OFFICE Cono Sur * 54.11.4783.5300 OMRON ELECTRONICS DE MEXICO * HEAD OFFICE Mexico DF * 52.55.59.01.43.00 * 001.800.556.6766 * mela@omron.com OMRON CHILE * SALES OFFICE Santiago * 56.9.9917.3920 OMRON ELECTRONICS DE MEXICO * SALES OFFICE Apodaca, N.L. * 52.81.11.56.99.20 * 001.800.556.6766 * mela@omron.com OTHER OMRON LATIN AMERICA SALES 54.11.4783.5300 OMRON ELETRONICA DO BRASIL LTDA * HEAD OFFICE Sao Paulo, SP, Brasil * 55.11.2101.6300 * www.omron.com.br OMRON EUROpE B.V. * Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands. * Tel: +31 (0) 23 568 13 00 * Fax: +31 (0) 23 568 13 88 * www.industrial.omron.eu Automation Systems * Programmable logic controllers (PLC) * Human machine interfaces (HMI) * Remote I/O * Industrial PC's * Software Authorized Distributor: Motion & Drives * Motion controllers * Servo systems * AC drives Control Components * Temperature controllers * Power supplies * Timers * Counters * Programmable relays * Digital panel indicators * Electromechanical relays * Monitoring products * Solid-state relays * Limit switches * Pushbutton switches * Low voltage switch gear Sensing & Safety * Photoelectric sensors * Inductive sensors * Capacitive & pressure sensors * Cable connectors * Displacement & width-measuring sensors * Vision systems * Safety networks * Safety sensors * Safety units/relay units * Safety door/guard lock switches Cat. No. A190-E1-01 10/09 Note: Specifications are subject to change. Printed on recycled paper. (c) 2011 Omron Electronics LLC Printed in U.S.A.