DOMESTIC AND INDUSTRIAL CYLINDRICAL
FUSE-LINKS
Ferraz Shawmut gF, gI-gG and aM fuse-links cover a
wide range of physical sizes and ampere ratings for
250, 400, 500, and 690 volts AC. gF fuse-links are for
domestic use. gI-gG and aM fuse-links are for industri-
al applications. Most ratings are available with an
optional indicator. All industrial fuse-links have the
option of a built-in striker. All cylindrical fuse-links
have ceramic bodies and silver-plated ferrules.
EURO/IEC Fuses & Accessories
gF, gI-gG, aM CYLINDRICAL FUSE-LINKS
gF
FULL RANGE
PROTECTION
7 physical sizes
from 6.3 x 23mm
to 10.3 x 38 mm
250 and 400 Volt
ratings -
0.5A through 32A
Most ratings available
with indicator
Meet IEC, NFC, UNE
and British standards
gI-gG
FULL RANGE
PROTECTION
4 physical sizes
from 8 x 31mm
to 22 x 58 mm
400, 500 and 690
Volt ratings - 0.5A
through 125A
Most ratings available
with indicator
Meet IEC, NFC and
UNE standards
Approved by
Lloyds Register of
Shipping and
Bureau Veritas
gI-gG
FULL RANGE
PROTECTION
Fuse-links with
Striker
2 sizes-
14 x 51mm
and 22 x 58mm
400, 500 and
690 Volt ratings -
4A through 125A
All ratings include
striker
Meet IEC, NFC and
UNE standards
Approved by Lloyds
Register of Shipping
and Bureau Veritas
aM
SHORT CIRCUIT
PROTECTION
Fuse-links with
Striker
2 sizes -
14 x 51mm
and 22 x 58mm
400, 500 and
690 Volt ratings -
2A through 125A
All ratings include
striker
Meet IEC, NFC and
UNE standards
Approved by Lloyds
Register of Shipping
and Bureau Veritas
aM
SHORT CIRCUIT
PROTECTION
4 physical sizes
from 8 x 31mm
to 22 x 58mm
400, 500 and 690
Volt ratings - .16A
through 125A
Most ratings available
with indicator
Meet IEC, NFC and
UNE standards
Approved by Lloyds
Register of Shipping
and Bureau Veritas
F 2
EURO/IEC Fuses & Accessories
gF CYLINDRICAL FUSE-LINKS
F 3
SIZE RATED In RATED CATALOG NUMBER INTERRUPTING STANDARD
(mm x mm) CURRENT (A) VOLTAGE w/o Indicator w/Indicator RATING (A) PACK/CTN.
2 250V 10013-G - 6,000 10/100
6.3 x 23 4 10019-G -
6 10023-G -
10 10031-G -
2 250V 10213-G 12213-G 6,000 10/100
4 10219-G 12219-G
8.5 X 23 6 10223-G 12223-G
10 10231-G 12231-G
16 10235-G 12235-G
6 250V 10423-G 12423-G 6,000 10/100
10.3 X 25.8 10 10431-G 12431-G
16 10435-G 12435-G
0.5 400V 10609-G 12609-G 20,000 10/100
1 10611-G 12611-G
2 10613-G 12613-G
4 10619-G 12619-G
6 10623-G 12623-G
8.5 x 31.5 8 10627-G 12627-G
10 10631-G 12631-G
12 10633-G 12633-G
16 10635-G 12635-G
20 10637-G 12637-G
25 10639-G 12639-G
16 400V 10835-G 12835-G 20,000 10/100
10.3 x 31.5 20 10837-G 12837-G
25 10839-G 12839-G
2 400V 11013-G 13013-G 20,000 10/100
4 11019-G 13019-G
6 11023-G 13023-G
8.5 x 36 10 11031-G 13031-G
16 11035-G 13035-G
20 11037-G 13037-G
25 11039-G 13039-G
32 11043-G 13043-G
10.3 x 38 25 400V 11239-G 13239-G 20,000 10/100
32 11243-G 13243-G
FUSE SIZE
(mm x mm) A B C
6.3 X 23 6.3 23 5
8.5 X 23 8.5 23 5
10.3 x 25.8 10.3 25.8 6.3
8.5 x 31.5 8.5 31.5 6.3
10.3 x 31.5 10.3 31.5 10
8.5 x 36 8.5 36 6.3
10.3 x 38 10.3 38 10
Dimensions
Blown-Fuse Indicator
Catalog Numbers, Ratings – gF (Optional Blown-Fuse Indicator)
BEFORE AFTER
10031-G
10235-G
10637-G
10839-G
11035-G
11243-G
1Ceramic body
2Sand
3Indicator contact
4Lower contact
5Contact ring
6Melting element
7Indicator
F
EURO/IEC Fuses & Accessories
gF CYLINDRICAL FUSE-LINKS
F 4
Melting Time - Current Data – 2-16 Amperes, 250V
Current in Amperes
Time in Seconds
Melting Time - Current Data – 2-32 Amperes, 400V
Current in Amperes
Time in Seconds
EURO/IEC Fuses & Accessories
gI-gG CYLINDRICAL FUSE-LINKS
F 5
SIZE RATED In RATED CATALOG NUMBER INTERRUPTING STANDARD
(mm x mm) CURRENT (A) VOLTAGE w/o Indicator w/Indicator RATING (A) PACK/CTN.
0.5 400V 15009-G - 20,000
1 15011-G 15211-G
2 15013-G 15213-G
4 15019-G 15219-G
6 15023-G 15223-G
8 x 31 8 15027-G 15227-G 10/100
10 15031-G 15231-G
12 15033-G 15233-G
16 15035-G 15235-G
20 15037-G 15237-G
0.5 500V 16009-G - 120,000
1 16011-G -
2 16013-G 16213-G
4 16019-G 16219-G
6 16023-G 16223-G
10 X 38 8 16027-G 16227-G 10/100
10 16031-G 16231-G
12 16033-G 16233-G
16 16035-G 16235-G
20 16037-G 16237-G
25 16039-G 16239-G
32 400V 16043-G 16243-G
1 690V 17011-G - 80,000
2 17013-G 17213-G
4 17019-G 17219-G
6 17023-G 17223-G
8 17027-G 17227-G
10 17031-G 17231-G
14 X 51 12 17033-G 17233-G 10/50
16 17035-G 17235-G
20 17037-G 17237-G
25 17039-G 17239-G
32 500V 17043-G 17243-G 120,000
40 17047-G 17247-G
50 400V 17051-G 17251-G
2 690V 18013-G - 80,000
4 18019-G 18219-G
6 18023-G 18223-G
8 18027-G 18227-G
10 18031-G 18231-G
12 18033-G 18233-G
16 18035-G 18235-G
20 18037-G 18237-G
22 x 58 25 18039-G 18239-G 10/50
32 18043-G 18243-G
40 18047-G 18247-G
50 18051-G 18251-G
63 18055-G 18255-G
80 18059-G 18259-G
100 500V 18063-G 18263-G 120,000
125 400V 18065-G 18265-G
FUSE SIZE A B C
8 x 31 8.5 31.5 6.3
10 x 38 10.3 38 10.5
14 x 51 14.3 51 13.8
22 x 58 22.2 58 16.2
Dimensions
15037-G
16037-G
17039-G
18059-G
Catalog Numbers, Ratings – gI-gG (Optional Blown-Fuse Indicator)
Blown-Fuse Indicator
BEFORE AFTER
F
SIZE RATED RATED CATALOG INTERRUPTING STANDARD
(mm x mm) CURRENT In VOLTAGE NUMBER RATING (A) PACK/CTN.
(A)
2 500V 17413-G 120,000
4 17419-G
6 17423-G
8 17427-G
10 17431-G
12 17433-G
14 X 51 16 17435-G 10/50
20 17437-G
25 17439-G
32 17443-G
40 17447-G
50 400V 17451-G
4 690V 18419-G 80,000
6 18423-G
8 18427-G
10 18431-G
12 18433-G
16 18435-G
22 X 58 20 18437-G 10/50
25 18439-G
32 18443-G
40 18447-G
50 18451-G
63 18455-G
80 500V 18459-G 120,000
100 18463-G
125 400V 18465-G
EURO/IEC Fuses & Accessories
gI-gG CYLINDRICAL FUSE-LINKS
F 6
Catalog Numbers, Ratings – gI-gG with Striker
1Ceramic body
2Sand
3Indicator contact
4Lower contact
5Contact ring
6Melting element
7Indicator
Striker
BEFORE AFTER
18447-G
FUSE SIZE A B C D E
14 x 51 14.3 51 13.8 7.5 3.8
22 x 58 22.2 58 16.2 7.5 3.8
Dimensions
Melting Time - Current Data – 2-125 Amperes
Current in Amperes
Time in Seconds
Peak Let-Thru Current Data – 2-125 Amperes
Available Current in RMS Symmetrical Amperes
Maximum Instantaneous Peak Let-Thru Amperes
17447-G
EURO/IEC Fuses & Accessories
gI-gG CYLINDRICAL FUSE-LINKS
RATED SIZE
CURRENT
(A) 10 x 38 14 x 51 22 x 58
1 0.27 W
2 0.4 W 0.5 W
4 0.60 W 0.7 W 0.9 W
6 0.85 W 1.0 W 1.3 W
8 1.0 W 1.3 W 1.45 W
10 1.2 W 1.5 W 1.85 W
12 1.4 W 1.7 W 2.2 W
16 1.6 W 2.0 W 2.3 W
20 1.9 W 2.3 W 2.65 W
25 2.3 W 2.7 W 3.1 W
32 2.9 W 3.3 W 3.85 W
40 4 W 4.8 W
50 4.5 W 5.3 W
63 6.5 W
80 8 W
100 9 W
125 12.5 W
Power Loss (Watts) at Rated Current In
IEC 269-2 10 x 38 14 x 51 22 x 58
NFC 63210 25A 40A 100A
UBE 21103 3 W 5W 9.5 W
These values are much lower than those allowed by the standards.
Temperature
Temperature rise reached by gI-gG fuse-links at In, measured on their upper contact.
I2t Characteristics – Discrimination
I2t (Ampere2Seconds)
_____ 690V
_____ 500V Operating I2t
_____ 400V
____ _ Pre-arcing I2t
Fuse-link In (A)
F
F 7
EURO/IEC Fuses & Accessories
aM CYLINDRICAL FUSE-LINKS
F 8
SIZE RATED In RATED CATALOG NUMBER INTERRUPTING STANDARD
(mm x mm) CURRENT (A) VOLTAGE w/o Indicator w/Indicator RATING (A) PACK/CTN.
1 400V 15511-G - 20,000
2 15513-G -
4 15519-G -
8 x 31 6 15523-G - 10/100
8 15527-G -
10 15531-G -
0.16 500V 16503-G - 120,000
0.25 16507-G -
0.5 16509-G -
1 16511-G 16711-G
2 16513-G 16713-G
4 16519-G 16719-G
6 16523-G 16723-G
10 X 38 8 16527-G 16727-G 10/100
10 16531-G 16731-G
12 16533-G 16733-G
16 16535-G 16735-G
20 16537-G 16737-G
25 400V 16539-G 16739-G
0.25 690V 17507-G - 80,000
0.5 17509-G -
1 17511-G 17711-G
2 17513-G 17713-G
4 17519-G 17719-G
6 17523-G 17723-G
8 17527-G 17727-G
10 17531-G 17731-G
14 X 51 12 17533-G 17733-G 10/50
16 17535-G 17735-G
20 17537-G 17737-G
25 17539-G 17739-G
32 500V 17543-G 17743-G 120,000
40 17547-G 17747-G
45 17549-G 17749-G
50 400V 17551-G 17751-G
4 690V 18519-G 18719-G 80,000
6 18523-G 18723-G
8 18527-G 18727-G
10 18531-G 18731-G
12 18533-G 18733-G
16 18535-G 18735-G
22 x 58 20 18537-G 18737-G 10/50
25 18539-G 18739-G
32 18543-G 18743-G
40 18547-G 18747-G
50 18551-G 18751-G
63 18555-G 18755-G
80 18559-G 18759-G
100 500V 18563-G 18763-G 120,000
125 400V 18565-G 18765-G
FUSE SIZE A B C
8 x 31 8.5 31.5 6.3
10 x 38 10.3 38 10.5
14 x 51 14.3 51 13.8
22 x 58 22.2 58 16.2
Dimensions
15519-G
16535-G
17535-G
18555-G
Catalog Numbers, Ratings – aM (Optional Blown-Fuse Indicator)
Blown-Fuse Indicator
BEFORE AFTER
EURO/IEC Fuses & Accessories
aM CYLINDRICAL FUSE-LINKS
SIZE RATED In RATED CATALOG INTERRUPTING STANDARD
(mm x mm) CURRENT (A) VOLTAGE NUMBER RATING (A) PACK/CTN.
1 500V 17911-G 120,000
2 17913-G
4 17919-G
6 17923-G
8 17927-G
10 17931-G
14 X 51 12 17933-G 10/50
16 17935-G
20 17937-G
25 17939-G
32 17943-G
40 17947-G
45 17949-G
50 400V 17951-G
4 690V 18919-G 80,000
6 18923-G
8 18927-G
10 18931-G
12 18933-G
16 18935-G
22 X 58 20 18937-G 10/50
25 18939-G
32 18943-G
40 18947-G
50 18951-G
63 18955-G
80 500V 18959-G 120,000
100 400V 18963-G
125 18965-G
FUSE SIZE A B C D E
14 x 51 14.3 51 13.8 7.5 3.8
22 x 58 22.2 58 16.2 7.5 3.8
Dimensions
17947-G
18951-G
Catalog Numbers, Ratings – aM with Striker
Striker
BEFORE AFTER
Melting Time - Current Data – 1-125 Amperes
Current in Amperes
Time in Seconds
Available Current in RMS Symmetrical Amperes
Maximum Instantaneous Peak Let-Thru Amperes
Peak Let-Thru Current Data – 1-125 Amperes
F
F 9
EURO/IEC Fuses & Accessories
aM CYLINDRICAL FUSE-LINKS
F 10
Power Loss (Watts) at Rated Current In
IEC 269-2 10 x 38 14 x 51 22 x 58
NFC 63210 16 A 50 A 100 A
UNE 21103 1.2 W 3 W 7 W
These values are much lower than those allowed by the standards.
Temperature
I2t Characteristics – Discrimination
I2t (Ampere2Seconds)
Fuse-link In (A)
_____690V
_____ 500V Operating I2t
_____ 400V
____ _ Pre-arcing I2t
RATED In SIZE
CURRENT
(A) 10 x 38 14 x 51 22 x 58
1 0.1 W
2 0.2 W 0.3 W
4 0.3 W 0.4 W 0.5 W
6 0.4 W 0.5 W 0.6 W
8 0.5 W 0.6 W 0.8 W
10 0.6 W 0.8 W 1.0 W
12 0.7 W 1.0 W 1.2 W
16 0.8 W 1.2 W 1.5 W
20 1.2 W 1.5 W 1.8 W
25 1.6 W 1.9 W 2.0 W
32 2.0 W 2.3 W 2.6 W
40 2.6 W 3.2 W
50 2.9 W 3.9 W
63 4.7 W
80 5.9 W
100 6.5 W
125 9.5 W
Temperature rise reached by aM fuse-links at In, measured on their upper contact.