Features
Multi-voltage and multi-function timer range
Front panel or socket mount
8 - 11 pin plug-in version available
Time scales from 0.05s to 100h
“1 delayed contact +1 instantaneous
contact” version available (type 88.12)
Front panel mounting fixing included
90 series sockets
Multi-function
11 pin
Plug-in for use with 90 series sockets
88.02 88.12
88 Series - Plug-in timers 5 - 8 A
AI: ON delay
DI: ON pulse
GI: Fixed pulse (0.5s) delayed
SW: Symmetrical recycling: ON start
Al a: ON Delay (2 timed contacts)
Al b: ON Delay (1 timed + 1 instantaneous contact)
Dl a: ON Pulse (2 timed contacts)
Dl b: ON Pulse (1 timed + 1 instantaneous contact)
GI: Fixed pulse (0.5s) delayed
SW: Symmetrical recycling.
2 CO (DPDT) 2 CO (DPDT)
8/15 5/10
250/250 250/400
2,000 1,250
400 250
0.3 0.125
8/0.3/0.12 5/0.3/0.12
300 (5/5) 500 (5/5)
AgNi AgCdO
24…230 24…230
24...230 24...230
2.5 (230 V)/1 (24 V) 2.5 (230 V)/1.5 (24 V)
20.4…264.5 20.4…264.5
20.4…264.5 20.4…264.5
(0.05 s…5 h) - (0.05 s…10 h) - (0.05 s…50 h) - (0.05 s…100 h)
±1 ±1
300 200
50
±3 ±3
100·103100·103
–10…+55 –10…+55
IP 40 IP 40
Multi-function
8 pin, 2 timed contacts or
1 timed + 1 instantaneous contact
Plug-in for use with 90 series sockets
BE: Signal OFF delay
CE: Signal ON and OFF delay
DE: Signal ON pulse
without signal START
with signal START
without signal START
Contact specification
Contact configuration
Rated current/Maximum peak current A
Rated voltage/Maximum switching voltage V AC
Rated load AC1 VA
Rated load AC15 (230 V AC) VA
Single phase motor rating (230 V AC) kW
Breaking capacity DC1: 30/110/220 V A
Minimum switching load mW (V/mA)
Standard contact material
Supply specification
Nominal voltage (UN) V AC (50/60 Hz)
V DC
Rated power AC/DC VA (50 Hz)/W
Operating range AC
DC
Technical data
Specified time range
Repeatability %
Recovery time ms
Minimum control impulse ms
Setting accuracy-full range %
Electrical life at rated load AC1 cycles
Ambient temperature range °C
Protection category
Approvals (according to type)
48
48
37
9
16
79.5
94
44.5
10 2 115678 9413
L/+
N/–
A2 A1 22 21 24 32 31 34 12 11 14
U
PR
1274 3586
C1C2
L/+
N/–
A1 A2 12 11 14 22 21 24
U
10 2 115678 9413
L/+
N/–
A2 A1 22 21 24 32 31 34 12 11 14
U
SPR
1
P = Pause
S = Start
R = Reset
AYellow LED: power ON (U)
BRed LED: timing in progress (C)
CUnit of time selected
FFunction selected
GTime selected
s min h x10h
0.5 0.5 second 0.5 minute 0.5 hour 5 hour
11 second 1 minute 1 hour 10 hour
55 second 5 minute 5 hour 50 hour
10 10 second 10 minute 10 hour 100 hour
Time scales
Full scale value
EMC specifications
Type of test Reference standard
Electrostatic discharge contact discharge EN 61000-4-2 4 kV
air discharge EN 61000-4-2 8 kV
Radio-frequency electromagnetic field (80 ÷ 1000 MHz) EN 61000-4-3 10 V/m
Fast transients (burst) (5-50 ns, 5 kHz) on Supply terminals EN 61000-4-4 2 kV
Surges (1.2/50 µs) on Supply terminals common mode EN 61000-4-5 2 kV
differential mode EN 61000-4-5 1 kV
Radio-frequency common mode (0.15 ÷ 80 MHz) EN 61000-4-6 3 V
on Supply terminals
Technical data
Example: 88 series multi-function timer, 2 CO (DPDT) contact 8 A, (24…230)V AC (50/60 Hz) and (24…230)V DC supply.
Ordering information
Special versions
2 = Standard
Supply voltage
230 = (24…230)V AC/DC
Series
Type
0 = Functions AI, DI, GI, SW, BE, CE, DE, 11 pin
1 = Functions Al a, Al b, Dl a, Dl b, GI, SW, 8 pin
No. of poles
2 = 2 pole
Supply version
0 = AC (50/60 Hz)/DC
0 2 0 0 0 2
... .
23088 0
Selection of: function, time scale and units
A
B
C
D
F
E
G
H
2
NOTE: time scales and functions must be set before energising the timer.
88 Series - Plug-in timers 5 - 8 A
88.02 88.12
E Function selector AI, DI, GI, SW, BE, CE, DE Al a, Al b, Dl a, Dl b, GI, SW
D Time scale selector 0.5, 1, 5, 10
H Unit of time selector s (second), min (minute), h (hour), 10h (10 hour)
DH
LED/visual indication
3
88 Series - Plug-in timers 5 - 8 A
U=Supply
Voltage
S=Signal
switch
P=Pause
R= Reset
= Output
Contact
LED
(red)
LED
(yellow)
Supply
voltage
NO output
contact
OFF
ON
ON
ON
Open
Open
Open (timing
in progress)
Closed
Functions
Contact
(AI) ON delay.
Apply power to timer. Output contacts transfer after preset time
has elapsed. Reset occurs when power is removed.
(BE) Signal OFF delay.
Power is permenently applied to the timer.
The output contacts transfer immediately on closure of the
Signal Switch (S). Opening the Signal Switch initiates the
preset delay, after which time the output contacts reset.
(DE) Signal ON pulse.
Power is permenently applied to the timer.
On momentary or maintained closure of Signal Switch (S),
the output contacts transfer, and remain so for the duration
of the preset delay, after which they reset.
(SW) Symmetrical recycling: ON start.
Apply power to timer. Output contacts transfer immediately
and cycle between ON and OFF for as long as power is
applied. The ratio is 1:1 (time on = time off).
without signal START
with signal START
Wiring diagram Type 88.02
10 2 115678 9413
L/+
N/–
A2 A1 22 21 24 32 31 34 12 11 14
U
SPR
10 2 115678 9413
L/+
N/–
A2 A1 22 21 24 32 31 34 12 11 14
U
PR
TTTT
U
t<T
TT
TTt<T
U
S
U
S
TT t<T
x1 - x4
x1 - x4
x1 - x2
x1 - x4
x1 - x2
x1 - x2
x1 - x2
x1 - x4
x1 - x2
x1 - x4
Open Closed
(DI) ON pulse.
Apply power to timer. Output contacts transfer immediately.
After the preset time has elapsed, contacts reset.
(GI) Fixed pulse (0.5s) delayed.
Apply power to timer. Output contacts transfer after preset
time has elapsed. Reset occurs after a fixed time of 0.5s.
T
U
t<T
0.5sT
U
(CE) Signal ON and OFF delay.
Power is permenently applied to the timer.
Closing the Signal Switch (S) initiates the preset delay, after
which
time the output contacts transfer. Opening the Signal
switch initiates the same preset delay, after which time the
output contacts reset.
T
U
T TT
S
T T
PAUSE (P)
Closure of the pause switch (2-5) will immediately halt the timing process,
but the elapsed time will be retained, and the current state of the output
contacts will be maintained.
On opening of the pause switch, timing resumes from the retained value.
This is applicable for all functions.
RESET (R)
A momentary closure of the reset switch (2-7) will reset the timer. Longer
term closure of the reset switch will hold the timer in the reset state. This
is applicable for all functions.
(Al a) ON Delay (2 timed contacts).
Apply power to timer.
Contacts (C1and C2) transfer after preset time has elasped.
Reset occurs when power is removed.
(Al b) ON Delay
(1 timed contact + 1 instantaneous contact).
Apply power to timer. Output contact (C1) transfers immediately.
Contact (C2) transfers after the preset time has elasped. Reset
occurs when power is removed.
(Dl a) ON pulse (2 timed contacts).
Apply power to timer.
Output contacts (C1and C2) transfer immediately.
After preset time has elasped, the contacts reset.
(Dl b) ON pulse (1 timed contact + 1 instantaneous contact).
Apply powert to timer. Output contacts (C1and C2) transfer
immediately. After preset time has elasped, the contact (C2)
resets. Contact (C1) resets when power is removed.
U
C1
T
C2
U
C1
T
C2
U
C1
T
C2
U
C1
T
C2
88 Series - Plug-in timers 5 - 8 A
Functions
without signal START
Wiring diagram Type 88.12
1274 3586
C1C2
L/+
N/–
A1 A2 12 11 14 22 21 24
U
(GI) Fixed pulse (0.5s) delayed.
Apply power to timer. Output contacts transfer after preset
time
has elapsed. Reset occurs after a fixed time of 0.5s.
(SW) Symmetrical recycling.
Apply power to timer. Output contacts transfer immediately
and cycle between ON and OFF for as long as power is applied.
The ratio is 1:1 (time on = time off).
U
C1
C2
T0.5s
TTTT
t<T
U
C1
C2
4
Ø 31
32.5
31 31
90.12.4 90.13.4
90 Series - Sockets and Accessories for 88 series Timers
Approvals
(according to type):
25.5
3518 14
67
3.2
30
38
27.5
22
COIL COILCOM COM
34
9
NO NC NCNO NO NC
32
8
24
7
22
5
14
3
12
4
A2
10
COM
31
11
21
6
11
1
A1
2
24
6
22
5
12
4
14
3
A2
7
21
8
11
1
A1
2
NO NC NONC
COIL COILCOM COM
Screw terminal (Box clamp) socket 90.20 90.20.0 90.21 90.21.0
panel or 35 mm rail (EN 50022) mount Blue Black Blue Black
For timer type 88.12 88.02
Technical data
Rated values 10 A - 250 V
Dielectric strength 2 kV AC
Protection category IP 20
Ambient temperature °C –40…+70
Screw torque Nm 0.5
Wire strip length mm 10
Max. wire size for 90.20 and 90.21 sockets solid wire stranded wire
mm21x6 / 2x2.5 1x6 / 2x2.5
AWG 1x10 / 2x14 1x10 / 2x14
67
3.2
30
38
27.5
90.20 90.21
Approvals
(according to type):
31
27.6
35
4.2
43
56
==
35
28
NO
COIL
COIL COM
NC NO
32
8
24
7
34
9
COM
A2
10
31
11
11
1
A1
2
14
3
NO
NC
12
4
NC
22
5
21
6
com
COILCOIL COM COM
A2
7
21
8
11
1
A1
2
NO NONC NC
24
6
22
5
14
3
12
4
Screw terminal (Plate clamp) socket 90.26
90.26.0
90.27
90.27.0
panel or 35 mm rail (EN 50022) mount Blue Black Blue Black
For timer type 88.12 88.02
Technical data
Rated values 10 A - 250 V
Dielectric strength 2 kV AC
Protection category IP 20
Ambient temperature °C –40…+70
Screw torque Nm 0.8
Wire strip length mm 10
Max. wire size for 90.26 and 90.27 sockets solid wire stranded wire
mm21x4 / 2x2.5 1x4 / 2x2.5
AWG 1x12 / 2x14 1x12 / 2x14
90.27
23
20
4.2
41
51
33
635
10
25.5
90.26
90.13.4
Approvals
(according to type):
Sockets 8-11 pin backwired with solder terminals 90.12.4 (black) 90.13.4 (black)
For timer type 88.12 88.02
Technical data
Rated values 10 A - 250 V
Dielectric strength 2 kV AC
Ambient temperature °C –40…+70
5
90.21
90.26