88 Series - Plug-in timers 5 - 8 A Features 88.02 88.12 Multi-voltage and multi-function timer range Front panel or socket mount 8 - 11 pin plug-in version available Time scales from 0.05s to 100h * "1 delayed contact +1 instantaneous contact" version available (type 88.12) * Front panel mounting fixing included * 90 series sockets * * Multi-function 8 pin, 2 timed contacts or 1 timed + 1 instantaneous contact * Plug-in for use with 90 series sockets * Multi-function * 11 pin * Plug-in for use with 90 series sockets * 48 48 AI: DI: GI: SW: Al a: ON Delay (2 timed contacts) Al b: ON Delay (1 timed + 1 instantaneous contact) Dl a: ON Pulse (2 timed contacts) Dl b: ON Pulse (1 timed + 1 instantaneous contact) GI: Fixed pulse (0.5s) delayed SW: Symmetrical recycling. 10 2 5 6 7 8 11 9 4 1 3 9 16 ON delay ON pulse Fixed pulse (0.5s) delayed Symmetrical recycling: ON start without signal START A2 A1 22 21 24 32 31 34 12 11 14 37 P L/+ U 79.5 94 * R without signal START N/- A1 A2 12 11 14 22 21 24 BE: Signal OFF delay CE: Signal ON and OFF delay DE: Signal ON pulse 2 7 4 N/- with signal START U 1 3 5 8 6 L/+ C1 C2 A2 A1 22 21 24 32 31 34 12 11 14 10 2 5 6 7 8 11 9 4 1 3 44.5 L/+ U P N/- P = Pause S = Start R = Reset S R Contact specification Contact configuration Rated current/Maximum peak current A Rated voltage/Maximum switching voltage V AC Rated load AC1 Rated load AC15 (230 V AC) Single phase motor rating (230 V AC) Breaking capacity DC1: 30/110/220 V Minimum switching load 2 CO (DPDT) 2 CO (DPDT) 8/15 5/10 250/250 250/400 VA 2,000 1,250 VA 400 250 kW 0.3 0.125 8/0.3/0.12 5/0.3/0.12 300 (5/5) 500 (5/5) AgNi AgCdO 24...230 24...230 A mW (V/mA) Standard contact material Supply specification Nominal voltage (UN) V AC (50/60 Hz) Rated power AC/DC VA (50 Hz)/W 24...230 24...230 2.5 (230 V)/1 (24 V) 2.5 (230 V)/1.5 (24 V) AC 20.4...264.5 20.4...264.5 DC 20.4...264.5 20.4...264.5 V DC Operating range Technical data (0.05 s...5 h) - (0.05 s...10 h) - (0.05 s...50 h) - (0.05 s...100 h) Specified time range Repeatability % 1 1 Recovery time ms 300 200 Minimum control impulse ms 50 -- Setting accuracy-full range Electrical life at rated load AC1 Ambient temperature range Protection category % cycles C 3 3 100*103 100*103 -10...+55 -10...+55 IP 40 IP 40 Approvals (according to type) 1 88 Series - Plug-in timers 5 - 8 A Ordering information Example: 88 series multi-function timer, 2 CO (DPDT) contact 8 A, (24...230)V AC (50/60 Hz) and (24...230)V DC supply. 8 8 . 0 2 . 0 . 2 3 0 . 0 0 0 2 Special versions 2 = Standard Series Type 0 = Functions AI, DI, GI, SW, BE, CE, DE, 11 pin 1 = Functions Al a, Al b, Dl a, Dl b, GI, SW, 8 pin Supply voltage 230 = (24...230)V AC/DC No. of poles 2 = 2 pole Supply version 0 = AC (50/60 Hz)/DC Technical data EMC specifications Type of test Reference standard Electrostatic discharge contact discharge EN 61000-4-2 4 kV air discharge EN 61000-4-2 8 kV Radio-frequency electromagnetic field (80 / 1000 MHz) EN 61000-4-3 10 V/m Fast transients (burst) (5-50 ns, 5 kHz) on Supply terminals EN 61000-4-4 2 kV Surges (1.2/50 s) on Supply terminals common mode EN 61000-4-5 2 kV differential mode EN 61000-4-5 1 kV EN 61000-4-6 3V Radio-frequency common mode (0.15 / 80 MHz) on Supply terminals Selection of: function, time scale and units 88.02 88.12 E Function selector AI, DI, GI, SW, BE, CE, DE Al a, Al b, Dl a, Dl b, GI, SW D Time scale selector 0.5, 1, 5, 10 H Unit of time selector s (second), min (minute), h (hour), 10h (10 hour) Time scales Full scale value H s min h x10h 0.5 0.5 second 0.5 minute 0.5 hour 5 hour 1 1 second 1 minute 1 hour 10 hour 5 5 second 5 minute 5 hour 50 hour 10 10 second 10 minute 10 hour 100 hour D NOTE: time scales and functions must be set before energising the timer. LED/visual indication A 2 Yellow LED: power ON (U) B Red LED: timing in progress (C) C Unit of time selected F Function selected G Time selected A B C D E F G H 88 Series - Plug-in timers 5 - 8 A Functions U =Supply Voltage LED (yellow) LED (red) Supply voltage NO output contact Open Closed Contact S =Signal switch OFF Open x1 - x4 x1 - x2 P =Pause ON Open x1 - x4 x1 - x2 x1 - x2 x1 - x4 R = Reset ON Open (timing in progress) x1 - x4 x1 - x2 ON Closed x1 - x2 x1 - x4 = Output Contact Wiring diagram without signal START Type 88.02 U A2 A1 22 21 24 32 31 34 12 11 14 P L/+ U R t