Current Transducer HAL 50..600-S For the electronic measurement of currents: DC, AC, pulsed..., with galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). IPN = 50 .. 600 A Electrical data Primary nominal current rms IPN (A) 50 100 200 300 400 500 600 IP VOUT RL VC IC Vb Vd Ris Primary current measuring range 4) IPM (A) 150 300 600 900 1000 1000 1000 Type RoHS since date code HAL 50-S HAL 100-S HAL 200-S HAL 300-S HAL 400-S HAL 500-S HAL 600-S 46180 46065 46090 46142 46114 46306 46059 Overload Capability (Ampere Turns) Output voltage (Analog) @ IPN Load resistance @ TA = 0 .. + 70C @ TA = - 25 .. + 85C Supply voltage ( 5 %) Current consumption Rated isolation voltage rms1) Rms voltage for AC isolation test, 50 Hz, 1 min Isolation resistance @ 500 VDC 30,000 4 >1 >3 15 < 25 500 3 > 500 Features * Hall effect measuring principle * Galvanic isolation between primary A V k k V mA V kV M Accuracy - Dynamic performance data Accuracy @ IPN , TA = 25C, 15 V X e Linearity error2) Eletrical offset voltage @ TA = 25C HAL 50-S HAL 100..600-S VOM Magnetic offset voltage @ IP = 0, after an overload of 3 x IPN HAL 50-S HAL 100..200-S HAL 300..600-S TCVOE Temperature coefficient of VOE HAL 50-S HAL 100..600-S TCVOUT Temperature coefficient of VOUT ( % of reading ) tr Response time to 90% of IPN step BW Frequency bandwidth (- 3 dB)3) L VOE Ambient operating temperature Ambient storage temperature Mass app. Standard4) Safety EMC Deviation in output when tested to EN 61000-4-6 Deviation in output when tested to EN 61000-4-3 Advantages * Easy installation * Small size and space saving * Only one design for wide current ratings range * High immunity to external interference < 1 % < 0.5 < 20 < 10 % of IPN mV mV < 30 < 20 < 10 < 2.0 < 1.0 0.05 3 DC .. 50 mV mV mV mV/K mV/K %/K s kHz General data TA TS m * * * * and secondary circuit Isolation voltage 3000V Low power consumption Extended measuring range(3 x IPN) Isolated plastic case recognized according to UL 94-V0 - 25 .. + 85 C - 25 .. + 85 C 75 g EN 50178 : 1994 EN50082-2: 1992 EN50081-1: 1992 < 20 % of IPN < 20 % of IPN Applications * * * * AC variable speed drives DC motor drives Battery supplied applications Uninterruptable Power Supplies (UPS) * Switched Mode Power Supplies (SMPS) * Power supplies for welding applications. Application domain * Industrial Notes : 1) Overvoltage Category III, Pollution Degree 2 2) Excludes the electrical offset 3) Derating is needed to avoid excessive core heating at high frequency. 4) Please consult characterisation report for more technical details and application advice. 110209/5 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. Page 1/2 www.lem.com Dimensions HAL 50..600-S (in mm. 1 mm = 0.0394 inch) Secondary terminals Terminal 1 Terminal 2 Terminal 3 Terminal 4 Mechanical characteristics General tolerance Primary through-hole Connection of secondary : supply voltage +15V : supply voltage -15V : output : 0V Safety 0.5 mm 20 mm x 15 mm Molex 5045-04-A Remarks VOUT is positive when IP flows in the direction of the arrow. Temperature of the primary conductor should not exceed 90C. This is a standard model. For different versions please contact us. This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the manufacturer's operating instructions. Caution, risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a built-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected. Page 2/2 110209/5 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. www.lem.com