http://www.tracopower.com Page 1 of 4
Features
Ultra wide 4:1 input voltage range
Adjustable output voltage
Remote On/Off
Continuous short circuit protection
Over voltage protection
Over temperature protection
I/O isolation 1500 VDC
Input filter meets EN 55032, class A and
FCC, level A without external components
Fully RoHS compliant
3-year product warranty
DC/DC Converters
TEN 25WI Series, 25/30 Watt
The TEN 25WI series is a family of high performance dc-dc converter modules up to
30 Watt featuring ultra wide 4:1 input voltage ranges in a compact low profile case
with industry standard footprint. Standard features include remote On/Off, output
voltage trimming, over voltage protection, under voltage lockout, over temperature
and short circuit protection.
An other features is the internal EMI-filter to meet EN 55032, class A. Typical ap-
plications for these converter modules are industrial electronics, communication sys-
tems, battery operated equipment and distributed power systems.
Order code Input voltage range Output voltage Output current max. Efficiency typ.
TEN 25-2410WI 3.3 VDC 5’500 mA 82 %
TEN 25-2411WI 5 VDC 5‘000 mA 85 %
TEN 25-2412WI 10 – 40 VDC 12 VDC 2‘500 mA 89 %
TEN 25-2413WI (24 VDC nominal) 15 VDC 2‘000 mA 89 %
TEN 25-2422WI ±12 VDC ±1‘250 mA 89 %
TEN 25-2423WI ±15 VDC ±1‘000 mA 89 %
TEN 25-4810WI 3,3 VDC 5’500 mA 82 %
TEN 25-4811WI 5 VDC 5‘000 mA 85 %
TEN 25-4812WI 18 – 75 VDC 12 VDC 2‘500 mA 89 %
TEN 25-4813WI (48 VDC nominal) 15 VDC 2‘000 mA 89 %
TEN 25-4822WI ±12 VDC ±1‘250 mA 89 %
TEN 25-4823WI ±15 VDC ±1‘000 mA 89 %
Models
UL 60950 -1
http://www.tracopower.com Page 2 of 4
Input Specifications
Input current no load 24 V models: 20 mA max.
48 V models: 10 mA max.
Input current full load 24 V; 3.3 VDC models: 920 mA typ.
24 V; 5.0 VDC models: 1220 mA typ.
24 V; other output models: 1400 mA typ.
48 V; 3.3 VDC models: 460 mA typ.
48 V; 5.0 VDC models: 610 mA typ.
48 V; other output models: 700 mA typ.
Surge voltage (100 ms max.) 24 V models: 50 V max.
48 V models: 100 V max.
Reverse polarity 2 A max.
Reflected input ripple current 24 V models: 50 mA typ.
48 V models: 25 mA typ.
Conducted noise (input) EN 55032 level A, FCC part 15, level A
Start-up voltage / under voltage shut down 24 V models: 9.7 VDC / 9.3 VDC typ.
48 V models: 17.5 VDC / 16.5 VDC typ.
Output Specifications
Voltage set accuracy ±1 %
Output voltage adj. range ±10 % with external resistor (see page 4)
Regulation – Input variation Vin min. to Vin max. 0.5 % max.
– Load variation 10 – 100 % single output models: 1.0 % max.
dual output models balanced load: 2.0 % max.
Minimum load 10 % of rated max current (operation at lower
load condition is safe but a higher output ripple
will be experienced)
Temperature coefficient ±0.02 %/°C max.
Ripple and noise (20 MHz Bandwidth) 80 mVpk-pk max.
Transient response (25 % load step change) 150 µs typ.
Output current limitation >120 % of Iout max.
Short circuit protection indefinite, automatic recovery
Thermal shutdown at 115°C typ.
Capacitive load 3.3 & 5 VDC models: 10’000 µF
12 &15 VDC models: 1000 µF
dual output models: 330 µF
General Specifications
Temperature ranges Operating –40°C to +85°C (with derating)
– Casing +105°C max.
– Storage –50°C to +125°C
Load derating without heatsink 2 %/K above 5C
with heatsink 2.5 %/K above 65°C
Humidity (non condensing) 95 % rel H max.
Reliability, calculated MTBF (MIL-HDBK-217F, at +25°C, ground benign) >550’000 h
Isolation voltage (60 s) – Input/Output 1500 VDC
Isolation capacitance – Input/Output (100 kHz, 1 V) 1200 pF typ.
Isolation resistance – Input/Output (500 VDC) >1’000 MOhm
Switching frequency (fixed) 330 kHz typ. (puls width modulation)
DC/DC Converters
TEN 25WI Series, 25/30W
http://www.tracopower.com Page 3 of 4
DC/DC Converters
TEN 25WI Series, 25/30W
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
General Specifications
Remote On/Off: – On: 2.5 to 100 VDC or open circuit.
– Off: 1.0 to +1.0 VDC or short circuit pin 3 and 2
– Standby current: 5 mA max.
Safety standards UL/cUL 60950-1, IEC/EN 60950-1
Safety approvals – UL/cUL www.ul.com -> certifications -> File e188913
Physical Specifications
Casing material copper, nickel plated
Baseplate non conductive FR4
Potting material silicon (UL 94 V-0 rated)
Weight 56 g (1.98 oz)
Soldering temperature 265°C / 10 s max.
Environmental compliance – Reach www.tracopower.com/info/reach-declaration.pdf
– RoHS RoHS directive 2011/65/EU
Output Voltage Adjustments
10K
Pot.
–Vout
Trim
+Vout
Trim
+Vout Trim
Rx Rx
Rx = Vn -- Vo
36.667 x Vo -- 33 x Vn Rx = Vo -- Vn
33 x Vn -- 30 x Vo Vo = adjusted output voltage [VDC]
Vn = nominal output voltage [VDC]
Rx = trim resistor [Kohm]
–Vout
Nominal output voltage at open Trim input.
Trim down Trim up
Application note: www.tracopower.com/overview/ten25wi
Page 4 of 4
Specifications can be changed without notice! Make sure you are using the latest documentation, downloadable at www.tracopower.com
www.tracopower.com
DC/DC Converters
TEN 25WI Series, 25/30W
Outline Dimensions
Rev. March 14. 2018
Pin Single Dual
1+Vin (Vcc) +Vin (Vcc)
2–Vin (GND) –Vin (GND)
3Remote On/Off
4No pin + Vout
5+ Vout Common
6–Vout –Vout
7Trim
Pin-Out
Heat-sink TEN-HS5 (optional)
Dimensions in [mm], () = Inch
Pin diameter: 1.0 ±0.05 (0.02 ±0.002)
Pin pitch tolerances: ±0.35 (± 0.014 )
Case tolerances: ±0.5 (±0.02)
Note:
The product label on converter has to be re-
moved before mounting the heat-sink.
For volume orders converters will be supplied
with heat-sinks already mounted. Please con-
tact factory for quotation.
Separate heat-sinks are only available for
prototypes and small quantity orders.
Order code: TEN-HS5
(cont.: heat-sink, thermal pad, 2 clamps)
Material: Aluminum
Finish: Anodic treatment (black)
Weight: 15 g (0.53oz) (without converter)
610.2
40.6
10.16
5.08
50.8
6
5
4
1
2
7
Bottom
view
45.72
(2.0)
(0.24)
(1.6)
(0.4)
(0.40)
(0.4) (0.4)
(0.2)
(1.8)
12.7
(0.5)
5.1
(0.2)
3
10.16 10.16
10.16
(0.4)
2.5
(0.1)
56.0 (2.2) max.
23.0 (0.9)
17.2 (0.68)
max.
Converter
Heat-sink
Thermal pad
Clamp
*Optional versions:
• without remote and trim pins add suffix -B (e.g.TEN 25-2412WI-B)
• without remote pin add suffix -B1 (e.g. TEN 25-2413WI-B1)
• without trim pin add suffix -B2 (e.g. TEN-25-4811WI-B2)
Heat-Sink (Option)