D5V0P4URL6SO 4 CHANNEL LOW CAPACITANCE TVS DIODE ARRAY Features VBR (Min) IPP (Max) CT (Typ) 4.5V 20A 2.4pF Description The D5V0P4URL6SO is a high performance device suitable for protecting four high-speed I/Os. These devices are assembled in SOT26 packages and have high ESD surge capability and low capacitance. Clamping Voltage: 7.5V at 12A 100ns, TLP 6V at 5A 8s/20s IEC 61000-4-2 (ESD): Air - 30kV, Contact - 30kV IEC 61000-4-4 (EFT): 80A (5/50ns) IEC 61000-4-5 (Lighting): 20A (8/20s) 4 Channels of ESD Protection Low Channel Input Capacitance of 2.4pF Typical TLP Dynamic Resistance: 0.15 Totally Lead-Free & Fully RoHS Compliant (Notes 1 & 2) Halogen and Antimony Free. "Green" Device (Note 3) Applications Mechanical Data Typically used at high-speed ports such as USB 2.0, IEEE1394 (R) (FireWire , iLinkTM), Serial ATA, DVI, HDMI and PCI. Case: SOT26 Moisture Sensitivity: Level 1 per J-STD-020 Terminal Connections: See Schematic Terminals - Finish - Matte Tin Pleated Leadframe. Solderable per MIL-STD-202, Method 208 Weight: 0.016 grams (Approximate) SOT26 N/A Top View Device Schematic Circuit Schematic Ordering Information (Note 4) Product D5V0P4URL6SO-7 Notes: Compliance Standard Marking DE2 Reel Size (inches) 7 Tape Width (mm) 8 Quantity per Reel 3,000/Tape & Reel 1. No purposely added lead. Fully EU Directive 2002/95/EC (RoHS) & 2011/65/EU (RoHS 2) compliant. 2. See http://www.diodes.com/quality/lead_free.html for more information about Diodes Incorporated's definitions of Halogen- and Antimony-free, "Green" and Lead-free. 3. Halogen- and Antimony-free "Green" products are defined as those which contain <900ppm bromine, <900ppm chlorine (<1500ppm total Br + Cl) and <1000ppm antimony compounds. 4. For packaging details, go to our website at http://www.diodes.com/products/packages.html. Marking Information DE2 A17 Date Code Key Year Code Month Code 2015 C Jan 1 DE2 = Product Type Marking Code YM = Date Code Marking Y = Year (ex: A = 2015) M = Month (ex: 9 = September) Note: " " Represents Internal Code YM ADVANCE INFORMATION Product Summary 2016 D Feb 2 Mar 3 2017 E Apr 4 May 5 2018 F Jun 6 Jul 7 2019 G Aug 8 Sep 9 2020 H Oct O Nov N Dec D FireWire is a registered trademark of Apple Computer, Inc. iLink is a trademark of CEM Corporation. D5V0P4URL6SO Document number: DS38234 Rev. 1 - 2 1 of 5 www.diodes.com May 2016 (c) Diodes Incorporated D5V0P4URL6SO Maximum Ratings (@TA = +25C, unless otherwise specified.) Characteristic ADVANCE INFORMATION Peak Pulse Current, per IEC 61000-4-5 Peak Pulse Power, per IEC 61000-4-5 ESD Protection - Contact Discharge, per IEC 61000-4-2 ESD Protection - Air Discharge, per IEC 61000-4-2 Operating Temperature Storage Temperature Symbol Value Unit Conditions IPP 20 180 A W I/O to VSS, 8/20s PPP VESD_CONTACT 30 kV I/O to VSS VESD_AIR kV C I/O to VSS TOP 30 -55 to +85 TSTG -55 to +150 C I/O to VSS, 8/20s -- -- Thermal Characteristics Characteristic Symbol Value PD 300 mW RJA 417 C/W Power Dissipation Typical (Note 5) Thermal Resistance, Junction to Ambient Typical (Note 5) Electrical Characteristics Characteristic Reverse Working Voltage Reverse Current (Note 6) Reverse Breakdown Voltage Forward Clamping Voltage Reverse Clamping Voltage (Note7) ESD Clamping Voltage Dynamic Reverse Resistance Channel Input Capacitance Delta CI/O Notes: Unit (@TA = +25C, unless otherwise specified.) Symbol VRWM IR VBR VF VC VESD RDIF-R CI/O CI/OMAX-CI/OMIN Min -- -- 4.5 -- -- -- -- -- -- Typ -- -- -- 0.8 6 7.5 0.15 2.4 55 0.04 Max 3.3 1 8.0 1.2 -- -- -- 3 -- Unit V A V V V V pF pF Test Conditions IR=1mA, I/O to VSS VR = 3.3V, I/O to VSS IR = 1mA, I/O to VSS IF = 15mA, VSS to I/O IPP = 5A, I/O to VSS, 8/20s TLP, 12A, tP = 100ns, I/O to VSS TLP, 12A, tP = 100ns, I/O to VSS VI/O = 1.65V, VSS = 0V, f = 1MHz CI/OMAX-CI/OMIN 5. Device mounted on FR-4 PCB pad layout (2oz copper) as shown on Diodes, Inc. website at http://www.diodes.com/package-outlines.html. 6. Short duration pulse test used to minimize self-heating effect. 7. Clamping voltage value is based on an 8x20s peak pulse current (IPP) waveform. D5V0P4URL6SO Document number: DS38234 Rev. 1 - 2 2 of 5 www.diodes.com May 2016 (c) Diodes Incorporated IPP, PEAK PULSE CURRENT (%Ip p) PEAK PULSE DERATING IN % OF PEAK POWER OR CURRENT tR = 8S Peak Value I PP Half Value I PP /2 tp 12 3.5 11 I/O to VSS , f=1MHz 3.0 V C, CLAMPING VOLTAGE (V) CI/O , INPUT CAPACITANCE (pF) 8x20 Waveform as defined by R.E.A. t, TIME (S) Figure 2 Pulse Waveform TA, AMBIENT TEMPERATURE (C) Figure 1 Pulse Derating Curve 2.5 2.0 1.5 1.0 IEC61000-4-5 (Lighting) 10 9 8 7 6 5 4 3 2 0.5 1 0.0 0.0 0.5 1.0 1.5 2.0 2.5 3.0 VI/O, INPUT VOLTAGE (V) Figure 3 Input Capacitance vs. Input Voltage 3.5 2 3 4 5 6 7 8 9 VOLTAGE FROM I/O TO V SS (V) Figure 5 Current vs. Voltage 10 0 4 6 8 10 12 14 16 18 CURRENT FROM I/O TO VSS (A) Figure 4 Clamping Voltage Characteristic 20 18 CURRENT FROM I/O TO V SS (A) ADVANCE INFORMATION D5V0P4URL6SO 16 14 12 10 8 6 4 2 0 0 1 D5V0P4URL6SO Document number: DS38234 Rev. 1 - 2 3 of 5 www.diodes.com May 2016 (c) Diodes Incorporated D5V0P4URL6SO Package Outline Dimensions ADVANCE INFORMATION Please see http://www.diodes.com/package-outlines.html for the latest version. SOT26 D E1 SOT26 Dim Min Max Typ A1 0.013 0.10 0.05 A2 1.00 1.30 1.10 A3 0.70 0.80 0.75 b 0.35 0.50 0.38 c 0.10 0.20 0.15 D 2.90 3.10 3.00 e - - 0.95 e1 - - 1.90 E 2.70 3.00 2.80 E1 1.50 1.70 1.60 L 0.35 0.55 0.40 a - - 8 a1 - - 7 All Dimensions in mm E b a1 e1 A2 A3 A1 Seating Plane e L c a Suggested Pad Layout Please see http://www.diodes.com/package-outlines.html for the latest version. SOT26 C1 Y1 G C Y Dimensions Value (in mm) C 2.40 C1 0.95 G 1.60 X 0.55 Y 0.80 Y1 3.20 X D5V0P4URL6SO Document number: DS38234 Rev. 1 - 2 4 of 5 www.diodes.com May 2016 (c) Diodes Incorporated D5V0P4URL6SO IMPORTANT NOTICE ADVANCE INFORMATION DIODES INCORPORATED MAKES NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, WITH REGARDS TO THIS DOCUMENT, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE (AND THEIR EQUIVALENTS UNDER THE LAWS OF ANY JURISDICTION). Diodes Incorporated and its subsidiaries reserve the right to make modifications, enhancements, improvements, corrections or other changes without further notice to this document and any product described herein. Diodes Incorporated does not assume any liability arising out of the application or use of this document or any product described herein; neither does Diodes Incorporated convey any license under its patent or trademark rights, nor the rights of others. Any Customer or user of this document or products described herein in such applications shall assume all risks of such use and will agree to hold Diodes Incorporated and all the companies whose products are represented on Diodes Incorporated website, harmless against all damages. Diodes Incorporated does not warrant or accept any liability whatsoever in respect of any products purchased through unauthorized sales channel. Should Customers purchase or use Diodes Incorporated products for any unintended or unauthorized application, Customers shall indemnify and hold Diodes Incorporated and its representatives harmless against all claims, damages, expenses, and attorney fees arising out of, directly or indirectly, any claim of personal injury or death associated with such unintended or unauthorized application. Products described herein may be covered by one or more United States, international or foreign patents pending. Product names and markings noted herein may also be covered by one or more United States, international or foreign trademarks. This document is written in English but may be translated into multiple languages for reference. Only the English version of this document is the final and determinative format released by Diodes Incorporated. LIFE SUPPORT Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in significant injury to the user. B. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or to affect its safety or effectiveness. Customers represent that they have all necessary expertise in the safety and regulatory ramifications of their life support devices or systems, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use of Diodes Incorporated products in such safety-critical, life support devices or systems, notwithstanding any devices- or systems-related information or support that may be provided by Diodes Incorporated. Further, Customers must fully indemnify Diodes Incorporated and its representatives against any damages arising out of the use of Diodes Incorporated products in such safety-critical, life support devices or systems. Copyright (c) 2016, Diodes Incorporated www.diodes.com D5V0P4URL6SO Document number: DS38234 Rev. 1 - 2 5 of 5 www.diodes.com May 2016 (c) Diodes Incorporated