V A C U U M S C H M E LZ E
SPECIFICATION
Item no.:
T60404-N4646-X111
K-No.:
25440 100 A Current Sensor
Date:
17.04.2013
Customer:
Standard type
Customers Part no.:
Page 1 of 2
Hrsg.:
KB-E
editor
Bearb:
designer
Le
KB-PM IA: KRe.
check
freig.: HS
released
Copying of this document, disclosing it to third parties or using the contents there for any purposes without express written authorization by use illegally forbidden
Any offenders are liable to pay all relevant damages.
For the electronic measurement of currents:
DC, AC, pulsed, mixed ..., with a galvanic
Isolation between the primary circuit
(high power) and the secondary circuit
(electronic circuit)
Description
Closed loop (compensation)
Current Sensor with magnetic
field probe
Printed circuit board mounting
Casing and materials UL-listed
Characteristics
Excellent accuracy
Very low offset current
Very low temperature dependency and offset
current drift
Very low hysteresis of offset current
Short response time
Wide frequency bandwidth
Compact design
Reduced offset ripple
Mainly used for stationary operation in industrial
applications:
AC variabel speed drives and servo motor
drives
Static converters for for DC motor drives
Battery supplied applications
Switched Mode Power Supplies (SMPS)
Power Supplies for welding applications
Uninterruptable Power Supllies (UPS)
Electrical data – Ratings
I
PN
Primary nominal r.m.s. current 100 A
R
M
Measuring resistance V
C
12V 0 ... 200
V
C
15V 5 … 400
I
SN
Secondary nominal r.m.s. current 50 mA
K
N
Turns ratio 1: 2000
Accuracy – Dynamic performance data min. typ. max. Unit
I
P,max
Max. measuring range
@ V
C
= ±12V, R
M
= 5 (t
max
= 10sec) ±188 A
@ V
C
= ±15V, R
M
= 5 (t
max
= 10sec) ±236 A
X Accuracy @ I
PN
, T
A
= 25°C 0.1 0.5 %
ε
L
Linearity 0.1 %
I
0
Offset current @ I
P
=0, T
A
= 25°C 0.02 0.05 mA
t
r
Response time 1 µs
t (I
P,max
) Delay time at di/dt = 100 A/µs 200 ns
f Frequency bandwidth DC...200 kHz
General data min. typ. max. Unit
T
A
Ambient operating temperature -40 +85 °C
T
S
Ambient storage temperature -40 +90 °C
m Mass 15 g
V
C
Supply voltage ±11.4 ±12 or ±15 ±15.75 V
I
C
Current consumption 18 mA
Constructed and manufactored and tested in accordance with EN 61800-5-1 (primary vs. secondary)
Reinforced insulation, Insulation material group 1, Pollution degree 2
S
clear
Clearance
(component without solder pad)
12 mm
S
creep
Creepage
(component without solder pad)
12
mm
V
sys
System voltage
overvoltage category 3
RMS 600 V
V
work
Working voltage
(table 7 acc. to EN61800-5-1)
over voltage category 2
RMS 1000 V
U
PD
Rated discharge voltage peak value 1225 V
Max. potential difference acc. to UL 508 RMS 600 V
AC
Maximale Dauer- und Spitzenströme bei bestimmten Temperaturen
Supply voltage ±12 V: Supply voltage ±15V:
Date Name Isuue Amendment
17.04.13 KRe. 81 Mechnaical outline: marking with UL-sign and max. potential difference acc. to UL 508 added. CN-651
05.02.13 Le 81 Mechanical outline changed (the reference line at the standoff is just a bit down-eccentric). Lapidary change.
T
A
85 °C 55 °C
I
P
125 A 150 A
I
P,max
183 A 194 A
R
M
5
5
70 °C
150 A
185 A
5
85 °C
100 A
188 A
5
T
A
85 °C 55 °C
I
P
125 A 150 A
I
P,max
204 A 244 A
R
M
20
5
70 °C
150 A
232 A
5
85 °C
100 A
236 A
5
V A C U U M S C H M E LZ E
SPECIFICATION
Item no.:
T60404-N4646-X111
K-No.:
25440 100 A Current Sensor
Date:
17.04.2013
Customer:
Standard type
Customers Part no.:
Page 2 of 2
Hrsg.:
KB-E
editor
Bearb:
designer
Le
KB-PM IA: KRe.
check
freig.: HS
released
Copying of this document, disclosing it to third parties or using the contents there for any purposes without express written authorization by use illegally forbidden
Any offenders are liable to pay all relevant damages.
For the electronic measurement of currents:
DC, AC, pulsed, mixed ..., with a galvanic
Isolation between the primary circuit
(high power) and the secondary circuit
(electronic circuit)
Mechanical outline (mm):
General tolerances DIN ISO 2768-c
Tolerances grid distance ±0,2mm
DC = Date Code
F = Factory
36,5
22,9
5,08
14,3 6,55
27,6
12,35
0,4
4,7±0,5*
*
= preliminary
0,7x0,7
12 3
21
22
12,1
22,9
1,6
5,2
3,2
13,97
Marking
Schematic diagram
+ V
c
I
s
+
+
-
Ca
+
M
1
3
2
i
P
- V
c
RM
Temperature of the primary conductor should not exceed 100°C
Additional indications are obtainable on request.
This specification is no declaration of warranty acc. BGB §443 dar.
Connections:
1…3: 0,7 x 0,7 mm
UL-sign
4646X111
F DC
Marking:
Explanation:
DC = Date Code [Format YWW]
V A C U U M S C H M E LZ E
Additional Information
Item No.:
T60404-N4646-X111
K-No.:
25440 100 A Current Sensor
Date:
17.04.2013
Customer:
Customers Part No.: Page 1 of 3
Hrsg.:
KB-E
editor
Bearb:
designer
Le
KB-PM IA: KRe
check
freig.: HS
released
Weitergabe sowie Vervielfältigung dieser Unterlage, Verwertung und Mitteilung ihres Inhalts
nicht gestattet, soweit nicht ausdrücklich zugestanden. Zuwiderhandlungen verpflichten zu
Schadenersatz. Alle Rechte für den Fall der Patenterteilung oder GM-Eintragung vorbehalten
Copying of this document, disclosing it to third parties or using the contents there for any
purposes without express written authorization by use illegally forbidden.
Any offenders are liable to pay all relevant damages.
For electronic current measurement:
DC, AC, pulsed, mixed ..., with a galvanic
isolation between primary circuit
(high power) and secondary circuit
Electrical Data (investigate by a type checking)
min. typ. max. Unit
V
Ctot
Maximum supply voltage
(without function)
±18 V
±15.75 to ±18 V: for 1s per hour
R
S
Secondary coil resistance @ T
A
=85°C 114
R
P
Primary resistance @ T
A
=25°C 0,1 m
X
Ti
Temperature drift of X
@ T
A
= -40 ... +85 °C 0.1 %
I
0ges
Offset current (including I
0
, I
0t
, I
0T
) 0.07 mA
I
0t
Long term drift Offset current I
0
0.025 mA
I
0T
Offset current temperature drift I
0
@ T
A
= -40 ...+85°C 0.025 mA
I
0H
Hyteresis current @ I
P
=0
(caused by primary current 10 x I
PN
)
0.025 0.05 mA
I
0
/V
C
Supply voltage rejection ratio 0.01 mA/V
i
oss
Offset ripple (with1 MHz- filter first order) 0,17 mA
i
oss
Offset ripple (with 100 kHz- filter first order) 0.025 0.05 mA
i
oss
Offset ripple (with 20 kHz- filter first order) 0.008 0.013 mA
C
k
Maximum possible coupling capacity (primary – secondary) 6 pF
Inspection (
Measurement after temperature balance of the samples at room temperature)
K
N
(N
1
/N
2
) (V) M3011/6 Transformation ratio (I
P
=100A, 40-80 Hz) 1 : 2000 ± 0,5 %
I
0
(V) M3226 Offset current < 0.05 mA
V
d
(V) M3014: Test voltage, rms, 1 s 1.8 kV
pin 1 – 3 vs. hole
V
e
(AQL 1/S4) Partial discharge voltage acc.M3024 (RMS) 1300 V
with V
vor
(RMS) 1625 V
Type Testing
(Pin 1 - 3 to hole)
V
W
HV transient test according to M3064 (1,2 µs / 50 µs-wave form) 8 kV
V
d
Testing voltage to M3014 (5 s) 3,6 kV
V
e
Partial discharge voltage acc.M3024 (RMS) 1300 V
with V
vor
(RMS) 1625 V
Datum Name Index Amendment
17.04.13 Le 81 Applicable documents: Further standards added. CN-651
05.02.13 Le 81 Date updated.
V A C U U M S C H M E LZ E
Additional Information
Item No.:
T60404-N4646-X111
K-No.:
25440 100 A Current Sensor
Date:
17.04.2013
Customer:
Customers Part No.: Page 2 of 3
Hrsg.:
KB-E
editor
Bearb:
designer
Le
KB-PM IA: KRe
check
freig.: HS
released
Weitergabe sowie Vervielfältigung dieser Unterlage, Verwertung und Mitteilung ihres Inhalts
nicht gestattet, soweit nicht ausdrücklich zugestanden. Zuwiderhandlungen verpflichten zu
Schadenersatz. Alle Rechte für den Fall der Patenterteilung oder GM-Eintragung vorbehalten
Copying of this document, disclosing it to third parties or using the contents there for any
purposes without express written authorization by use illegally forbidden.
Any offenders are liable to pay all relevant damages.
For electronic current measurement:
DC, AC, pulsed, mixed ..., with a galvanic
isolation between primary circuit
(high power) and secondary circuit
Limit curve of measurable current Î
P
(R
M
)
@ ambient temperature 85 °C
0
50
100
150
200
250
0 20 40 60 80 100 120 140 160 180 200 220 240
R
M
[]
N
P
* Î
P
[A]
V
C
= +/-15V - 5%
V
C
= +/-12V - 5%
Maximum measuring range (µs-range)
Output current behaviour of a 3kA current pulse
@ V
C
= ±15V und R
M
= 100
-200
0
200
400
600
800
1000
0 1 2 3 4 5 6 7 8 9 10
t [µs]
I [A]
Ip [A]
Ia / KN [A]
Fast increasing currents (higher than the specified I
p,max
), e.g. in case
of a short circuit, can be transmitted because the currents are
transformed directly and be limited by diodes only.
The offset ripple can be reduced by an external low pass. Simplest solution is a passive low pass filter of 1st order with
In this case the response time is enlarged.
It is calculated from:
aMrr
CRtt 5,2
+
Applicable documents
Current direction: A positive output current appears at point I
S
, by primary current in direction of the arrow.
Further standards UL 508 ; file E317483, category NMTR2 / NMTR8
aM
g
CR
f
=
π
2
1
V A C U U M S C H M E LZ E
Additional Information
Item No.:
T60404-N4646-X111
K-No.:
25440 100 A Current Sensor
Date:
17.04.2013
Customer:
Customers Part No.: Page 3 of 3
Hrsg.:
KB-E
editor
Bearb:
designer
Le
KB-PM IA: KRe
check
freig.: HS
released
Weitergabe sowie Vervielfältigung dieser Unterlage, Verwertung und Mitteilung ihres Inhalts
nicht gestattet, soweit nicht ausdrücklich zugestanden. Zuwiderhandlungen verpflichten zu
Schadenersatz. Alle Rechte für den Fall der Patenterteilung oder GM-Eintragung vorbehalten
Copying of this document, disclosing it to third parties or using the contents there for any
purposes without express written authorization by use illegally forbidden.
Any offenders are liable to pay all relevant damages.
For electronic current measurement:
DC, AC, pulsed, mixed ..., with a galvanic
isolation between primary circuit
(high power) and secondary circuit
Explanation of several of the terms used in the tablets (in alphabetical order)
I
0H
: Zero variation after overloading with a DC of tenfold the rated value (R
M
= R
MN
)
I
0t
: Long term drift of I
o
after 100 temperature cycles in the range -40 bis 85 °C.
t
r
: Response time, measured as delay time at I
P
= 0,8
.
I
Pmax
between a rectangular current and the output current.
t (I
Pmax
): Delay time between I
Pmax
and the output current i
a
with a primary current rise of di
1
/dt = 100 A/µs.
U
PD
Rated discharge voltage (recurring peak voltage separated by the insulation) proved with a sinusoidal voltage V
e
U
PD
= 2 * V
e
/ 1,5
V
vor
Defined voltage is the RMS valve of a sinusoidal voltage with peak value of 1,875 * U
PD
required for partial discharge
test in IEC 61800-5-1
V
vor
= 1,875 *U
PD
/ 2
V
sys
System voltage RMS value of rated voltage according to IEC 61800-5-1
V
work
Working voltage voltage according to IEC 61800-5-1 which occurs by design in a circuit or across insulation
X
ges
(I
PN
): The sum of all possible errors over the temperature range by measuring a current I
PN
:
(
)
1
IK
II
100X
SNN
PNS
ges
=
X: Permissible measurement error in the final inspection at RT, defined by
1
I
I
100X
SN
SB
=
where I
SB
is the output DC value of an input DC current of the same magnitude as the (positive) rated current (I
o
= 0 )
X
Ti
: Temperature drift of the rated value orientated output term. I
SN
(cf. Notes on F
i
) in a specified temperature range,
obtained by:
(
)
(
)
SN
A1SBA2SB
Ti
I
TITI
100
=X
ε
L
: Linearity fault defined by
SN
Sx
PN
P
L
I
I
I
I
100 =
ε
Where I
P
is any input DC and I
Sx
the corresponding output term. I
SN
: see notes of F
i
(I
o
= 0).
This “Additional information“ is no declaration of warranty according BGB §443.