STH Page 2 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2016 TELEDYNE RELAYS
STH\062016\Q2
Series STH
Output to 50A, 660 Vac
High Industrial Performance (HIPak) Solid-State Relays
ELECTRICAL SPECIFICATIONS
(+25°C ambient temperature unless otherwise specifi ed)
INPUT (CONTROL) SPECIFICATIONS
Min Max Units
Input Current Range 10 13 mA
Must Turn-Off Voltage 2.0 Vdc
Reverse Voltage Protection (R/D) 32 V
Clamping Voltage (R/D) 36 V
Input Immunity (EN1000-4-4) 2 kV
Input Immunity (EN1000-4-5) 2 kV
OUTPUT (LOAD) SPECIFICATIONS
Min Max Units
Peak Voltage
STH24DXX 600 Vpeak
STH48DXX 1200 Vpeak
Load Current Range (Resistive)
12 output current .005 12 Arms
25 output current .005 25 Arms
35 output current .005 40 Arms
50 output current .005 60 Arms
Maximum Surge Current Rating (Non-Repetitive)
12 output current 170 A
25 output current 350 A
35 output current 500 A
50 output current 720 A
On-State Voltage Drop
Up to 25 output current 0.85 V
Above 35 output current 0.9 V
Output Power Dissipation (Max)
12 output current 0.9x0.85xl+0.042xl² W
25 output current 0.9x0.85xl+0.016xl² W
35 output current 0.9x0.9xl+0.015xl² W
50 output current 0.9x0.9xl+0.012xl² W
Zero-Cross Window (Typical) ±35 Vac
Off-State Leakage Current 1 mA
Turn-On Time (60 Hz) 8.3 Vac
Turn-Off Time (60 Hz) 8.3 Vac
Off-State dv/dt 500 V/ųs
Maximum di/dt (Non-Repetitive) 50 A/ųs
Operating Frequency 0.1 800 Hz
I²T or fuse matching (<10ms)
12 output current 128 A²s
25 output current 600 A²s
35 output current 1250 A²s
50 output current 2500 A²s
Junction-Case Thermal Resistance
12 output current 2.5 °C/W
25 output current 1.7 °C/W
35 output current 0.6 °C/W
50 output current 0.45 °C/W
Conducted Immunity Level
IEC/EN6100-4-4
(bursts) 2kV criterion B
IEC/EN6100-4-5
(surge) 2kV criterion A (with external VDR)