COP8CBR9, COP8CCR9, COP8CDR9
www.ti.com
SNOS535I OCTOBER 2000REVISED MARCH 2013
COP8CBR9/COP8CCR9/COP8CDR9 8-Bit CMOS Flash Microcontroller with 32k Memory,
Virtual EEPROM, 10-Bit A/D and Brownout
Check for Samples: COP8CBR9,COP8CCR9,COP8CDR9
1 Introduction
1.1 FEATURES
123 6.67 MHz Operation from 3.33 MHz
32 kbytes Flash Program Memory with Security Oscillator, with 1.5 μs Instruction Cycle
Feature (COP8CBR9)
Virtual EEPROM using Flash Program Memory Thirteen Multi-Source Vectored Interrupts
1 kbyte Volatile RAM Servicing:
10-bit Successive Approximation Analog to External Interrupt
Digital Converter (up to 16 Channels) USART (2)
100% Precise Analog Emulation Idle Timer T0
USART with Onchip Baud Generator Three Timers (Each with 2 Interrupts)
2.7V 5.5V In-System Programmability of Flash MICROWIRE/PLUS Serial Peripheral
High Endurance -100k Read/Write Cycles Interface
Superior Data Retention - 100 years Multi-Input Wake-up
Dual Clock Operation with HALT/IDLE Power Software Trap
Save Modes Idle Timer with Programmable Interrupt
Three 16-bit Timers: Interval
Timers T2 and T3 can Operate at High Speed 8-bit Stack Pointer SP (Stack in RAM)
(50 ns Resolution) Two 8-bit Register Indirect Data Memory
Processor Independent PWM Mode Pointers
External Event Counter Mode True Bit Manipulation
Input Capture Mode WATCHDOG and Clock Monitor Logic
Brown-Out Reset (COP8CBR9/CCR9) Software Selectable I/O Options
OTHER FEATURES TRI-STATE Output/High Impedance Input
Single Supply Operation: Push-Pull Output
2.7V–5.5V (40°C to +85°C) Weak Pull Up Input
4.5V–5.5V (40°C to +125°C) Schmitt Trigger Inputs on I/O ports
Quiet Design (Low Radiated Emissions) High Current I/Os
Multi-Input Wake-Up with Optional Interrupts Temperature Range: –40°C to +85°C and
MICROWIRE/PLUS (Serial Peripheral –40°C to +125°C (COP8CCR9/CDR9)
Interface Compatible) Packaging: 44 and 68 PLCC, 44 WQFN, 48
Clock Doubler for and 56 TSSOP
20 MHz Operation from 10 MHz Oscillator True In-System, Real Time Emulation and
(COP8CCR9/CDR9) with 0.5 µs Instruction Debug Tools Available
Cycle
1.2 DESCRIPTION
The COP8CBR/CCR/CDR9 Flash microcontrollers are highly integrated COP8™ Feature core devices,
with 32k Flash memory and advanced features including Virtual EEPROM, A/D, High Speed Timers,
USART, and Brownout Reset. This single-chip CMOS device is suited for applica tions requiring a full
featured, in-system reprogrammable controller with large memory and low EMI. The same device is used
for development, pre-production and volume production with a range of COP8 software and hardware
development tools.
1Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
2COP8 is a trademark of Texas Instruments.
3All other trademarks are the property of their respective owners.
PRODUCTION DATA information is current as of publication date. Products conform to Copyright © 2000–2013, Texas Instruments Incorporated
specifications per the terms of the Texas Instruments standard warranty. Production
processing does not necessarily include testing of all parameters.
COP8CBR9, COP8CCR9, COP8CDR9
SNOS535I OCTOBER 2000REVISED MARCH 2013
www.ti.com
Table 1-1. Device included in this datasheet:
Flash Program RAM Brownout I/O
Device Memory Packages Temperature
(bytes) Voltage Pins
(bytes)
44 WQFN,
COP8CBR9 32k 1k 2.7V to 2.9V 37,39,49, 59 44/68 PLCC, 40°C to +85°C
48/56 TSSOP
44 WQFN, 40°C to +85°C
COP8CCR9 32k 1k 4.17V to 4.5V 37,39,49, 59 44/68 PLCC, 40°C to +125°C
48/56 TSSOP
44 WQFN, 40°C to +85°C
COP8CDR9 32k 1k No Brownout 37,39,49, 59 44/68 PLCC, 40°C to +125°C
48/56 TSSOP
These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam
during storage or handling to prevent electrostatic damage to the MOS gates.
2Introduction Copyright © 2000–2013, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
www.ti.com
SNOS535I OCTOBER 2000REVISED MARCH 2013
1 Introduction .............................................. 15 Functional Description ............................... 22
1.1 FEATURES .......................................... 15.1 CPU REGISTERS .................................. 22
1.2 DESCRIPTION ...................................... 15.2 PROGRAM MEMORY .............................. 22
2 Device Information ...................................... 45.3 DATA MEMORY .................................... 22
2.1 Block Diagram ....................................... 45.4 DATA MEMORY SEGMENT RAM EXTENSION ... 23
2.2 Connection Diagram ................................. 45.5 OPTION REGISTER ............................... 24
2.3 Architectural Overview ............................... 75.6 SECURITY ......................................... 25
3 Electrical Specifications ............................. 11 5.7 RESET .............................................. 26
3.1 Absolute Maximum Ratings ........................ 11 5.8 OSCILLATOR CIRCUITS .......................... 29
3.2 Electrical Characteristics DC Electrical 5.9 CONTROL REGISTERS ........................... 31
Characteristics (40°C TA+85°C) .............. 11 5.10 In-System Programming ............................ 34
3.3 Electrical Characteristics AC Electrical 5.11 Timers .............................................. 42
Characteristics (40°C TA+85°C) .............. 13 5.12 Power Saving Features ............................. 48
3.4 A/D Converter Electrical Characteristics (40°C 5.13 USART .............................................. 58
TA+85°C unless otherwise noted) (Single-ended
mode only) .......................................... 13 5.14 A/D Converter ...................................... 68
3.5 DC Electrical Characteristics (40°C TA5.15 Interrupts ............................................ 73
+125°C) ............................................. 14 5.16 WATCHDOG/Clock Monitor ........................ 81
3.6 AC Electrical Characteristics (40°C TA+125°C) 5.17 MICROWIRE/PLUS ................................ 84
...................................................... 15 5.18 Memory Map ....................................... 88
3.7 A/D Converter Electrical Characteristics (40°C 5.19 Instruction Set ...................................... 90
TA+125°C) (Single-ended mode only) ........... 16 5.20 Development Support ............................. 100
4 Pin Descriptions ....................................... 17 Revision History ........................................... 104
4.1 EMULATION CONNECTION ....................... 21
Copyright © 2000–2013, Texas Instruments Incorporated Contents 3
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
SNOS535I OCTOBER 2000REVISED MARCH 2013
www.ti.com
2 Device Information
2.1 Block Diagram
2.2 Connection Diagram
Figure 2-1. Plastic Chip Package (Top View) Figure 2-2. Plastic Chip Package (Top View)
See Package Number FN0068A See Package Number FN0044A
4Device Information Copyright © 2000–2013, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
www.ti.com
SNOS535I OCTOBER 2000REVISED MARCH 2013
Figure 2-3. WQFN Package (Top View) Figure 2-4. TSSOP Package (Top View)
See Package Number NJN0044A See Package Number DGG0048A
Figure 2-5. TSSOP Package (Top View)
See Package Number DGG0056A
Copyright © 2000–2013, Texas Instruments Incorporated Device Information 5
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
SNOS535I OCTOBER 2000REVISED MARCH 2013
www.ti.com
Table 2-1. Pinouts for All Packages
In System 44-Pin 48-Pin 56-Pin 68-Pin
Port Type Alt. Fun Emulation 44-Pin WQFN PLCC TSSOP TSSOP PLCC
Mode
L0 I/O MIWU or Low Speed OSC In 16 11 11 15 22
L1 I/O MIWU or CKX or Low Speed 17 12 12 16 23
OSC Out
L2 I/O MIWU or TDX 18 13 13 17 24
L3 I/O MIWU or RDX 19 14 14 18 25
L4 I/O MIWU or T2A 20 15 15 19 26
L5 I/O MIWU or T2B 21 16 16 20 27
L6 I/O MIWU or T3A 22 17 17 21 28
L7 I/O MIWU or T3B 23 18 18 22 29
G0 I/O INT Input 7 2 2 2 3
G1 I/O WDOUT(1) POUT 8 3 3 3 4
G2 I/O T1B Output 9 4 4 4 5
G3 I/O T1A Clock 10 5 5 5 6
G4 I/O SO 11 6 6 6 11
G5 I/O SK 12 7 7 7 12
G6 I SI 13 8 8 8 13
G7 I CKO 14 9 9 9 14
D0 O 42 37 41 49 58
D1 O 43 38 42 50 59
D2 O 44 39 43 51 60
D3 O 1 40 44 52 61
D4 O 2 41 45 53 62
D5 O 3 42 46 54 63
D6 O 4 43 47 55 64
D7 O 5 44 48 56 65
E0 I/O 47 54
E1 I/O 48 55
E2 I/O 56
E3 I/O 57
E4 I/O 67
E5 I/O 68
E6 I/O 1
E7 I/O 2
C0 I/O 11 18
C1 I/O 12 19
C2 I/O 13 20
C3 I/O 14 21
C4 I/O 23 30
C5 I/O 24 31
C6 I/O 25 32
C7 I/O 26 33
(1) G1 operation as WDOUT is controlled by Option Register bit 2.
6Device Information Copyright © 2000–2013, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
www.ti.com
SNOS535I OCTOBER 2000REVISED MARCH 2013
Table 2-1. Pinouts for All Packages (continued)
In System 44-Pin 48-Pin 56-Pin 68-Pin
Port Type Alt. Fun Emulation 44-Pin WQFN PLCC TSSOP TSSOP PLCC
Mode
A0 I/O ADCH0 33 39 46
A1 I/O ADCH1 34 40 47
A2 I/O ADCH2 36 31 35 41 48
A3 I/O ADCH3 37 32 36 42 49
A4 I/O ADCH4 38 33 37 43 50
A5 I/O ADCH5 39 34 38 44 51
A6 I/O ADCH6 40 35 39 45 52
A7 I/O ADCH7 41 36 40 46 53
B0 I/O ADCH8 24 19 19 27 34
B1 I/O ADCH9 25 20 20 28 35
B2 I/O ADCH10 26 21 21 29 36
B3 I/O ADCH11 27 22 22 30 37
B4 I/O ADCH12 28 23 23 31 38
B5 I/O ADCH13 or A/D MUX OUT 29 24 24 32 39
B6 I/O ADCH14 or A/D MUX OUT 30 25 25 33 40
B7 I/O ADCH15 or A/DIN 31 26 26 34 41
F0 I/O 7
F1 I/O 8
F2 I/O 9
F3 I/O 10
DVCC VCC 35 30 32 38 17, 45
DGND GND 32 27 27 35 16, 42
AVCC 34 29 31 37 44
AGND 33 28 28 36 43
CKI I 15 10 10 10 15
RESET I RESET 6 1 1 1 66
2.3 Architectural Overview
This table assumes that the control flag MSEL is set.
2.3.1 EMI REDUCTION
This table assumes that the control flag MSEL is set.
The COP8CBR/CCR/CDR devices incorporate circuitry that guards against electromagnetic interference -
an increasing problem in today's microcontroller board designs. TI's patented EMI reduction technology
offers low EMI clock circuitry, gradual turn-on output drivers (GTOs) and internal Icc smoothing filters, to
help circumvent many of the EMI issues influencing embedded control designs. TI has achieved 15 dB–20
dB reduction in EMI transmissions when designs have incorporated its patented EMI reducing circuitry.
2.3.2 IN-SYSTEM PROGRAMMING AND VIRTUAL EEPROM
The device includes a program in a boot ROM that provides the capability, through the
MICROWIRE/PLUS serial interface, to erase, program and read the contents of the Flash memory.
Additional routines are included in the boot ROM, which can be called by the user program, to enable the
user to customize in system software update capability if MICROWIRE/PLUS is not desired.
Copyright © 2000–2013, Texas Instruments Incorporated Device Information 7
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
SNOS535I OCTOBER 2000REVISED MARCH 2013
www.ti.com
Additional functions will copy blocks of data between the RAM and the Flash Memory. These functions
provide a virtual EEPROM capability by allowing the user to emulate a variable amount of EEPROM by
initializing nonvolatile variables from the Flash Memory and occasionally restoring these variables to the
Flash Memory.
The contents of the boot ROM have been defined by TI. Execution of code from the boot ROM is
dependent on the state of the FLEX bit in the Option Register on exit from RESET. If the FLEX bit is a
zero, the Flash Memory is assumed to be empty and execution from the boot ROM begins. For further
information on the FLEX bit, refer to Section Option Register.
2.3.3 DUAL CLOCK AND CLOCK DOUBLER
The device includes a versatile clocking system and two oscillator circuits designed to drive a crystal or
ceramic resonator. The primary oscillator operates at high speed up to 10 MHz. The secondary oscillator
is optimized for operation at 32.768 kHz.
The user can, through specified transition sequences (please refer to Power Saving Features), switch
execution between the high speed and low speed oscillators. The unused oscillator can then be turned off
to minimize power dissipation. If the low speed oscillator is not used, the pins are available as general
purpose bidirectional ports.
The operation of the CPU will use a clock at twice the frequency of the selected oscillator (up to 20 MHz
for high speed operation and 65.536 kHz for low speed operation). This doubled clock will be referred to in
this document as ‘MCLK'. The frequency of the selected oscillator will be referred to as CKI. Instruction
execution occurs at one tenth the selected MCLK rate.
2.3.4 TRUE IN-SYSTEM EMULATION
On-chip emulation capability has been added which allows the user to perform true in-system emulation
using final production boards and devices. This simplifies testing and evaluation of software in real
environmental conditions. The user, merely by providing for a standard connector which can be bypassed
by jumpers on the final application board, can provide for software and hardware debugging using actual
production units.
2.3.5 ARCHITECTURE
The COP8 family is based on a modified Harvard architecture, which allows data tables to be accessed
directly from program memory. This is very important with modern microcontroller-based applications,
since program memory is usually ROM or EPROM, while data memory is usually RAM. Consequently
constant data tables need to be contained in non-volatile memory, so they are not lost when the
microcontroller is powered down. In a modified Harvard architecture, instruction fetch and memory data
transfers can be overlapped with a two stage pipeline, which allows the next instruction to be fetched from
program memory while the current instruction is being executed using data memory. This is not possible
with a Von Neumann single-address bus architecture.
The COP8 family supports a software stack scheme that allows the user to incorporate many subroutine
calls. This capability is important when using High Level Languages. With a hardware stack, the user is
limited to a small fixed number of stack levels.
2.3.6 INSTRUCTION SET
In today's 8-bit microcontroller application arena cost/performance, flexibility and time to market are
several of the key issues that system designers face in attempting to build well-engineered products that
compete in the marketplace. Many of these issues can be addressed through the manner in which a
microcontroller's instruction set handles processing tasks. And that's why the COP8 family offers a unique
and code-efficient instruction set - one that provides the flexibility, functionality, reduced costs and faster
time to market that today's microcontroller based products require.
8Device Information Copyright © 2000–2013, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
www.ti.com
SNOS535I OCTOBER 2000REVISED MARCH 2013
Code efficiency is important because it enables designers to pack more on-chip functionality into less
program memory space (ROM, OTP or Flash). Selecting a microcontroller with less program memory size
translates into lower system costs, and the added security of knowing that more code can be packed into
the available program memory space.
2.3.6.1 Key Instruction Set Features
The COP8 family incorporates a unique combination of instruction set features, which provide designers
with optimum code efficiency and program memory utilization.
2.3.6.2 Single Byte/Single Cycle Code Execution
The efficiency is due to the fact that the majority of instructions are of the single byte variety, resulting in
minimum program space. Because compact code does not occupy a substantial amount of program
memory space, designers can integrate additional features and functionality into the microcontroller
program memory space. Also, the majority instructions executed by the device are single cycle, resulting
in minimum program execution time. In fact, 77% of the instructions are single byte single cycle, providing
greater code and I/O efficiency, and faster code execution.
2.3.6.3 Many Single-Byte, Multi-Function Instructions
The COP8 instruction set utilizes many single-byte, multifunction instructions. This enables a single
instruction to accomplish multiple functions, such as DRSZ, DCOR, JID, LD (Load) and X (Exchange)
instructions with post-incrementing and post-decrementing, to name just a few examples. In many cases,
the instruction set can simultaneously execute as many as three functions with the same single-byte
instruction.
JID: (Jump Indirect); Single byte instruction decodes external events and jumps to corresponding service
routines (analogous to “DO CASE” statements in higher level languages).
LAID: (Load Accumulator-Indirect); Single byte look up table instruction provides efficient data path from
the program memory to the CPU. This instruction can be used for table lookup and to read the entire
program memory for checksum calculations.
RETSK: (Return Skip); Single byte instruction allows return from subroutine and skips next instruction.
Decision to branch can be made in the subroutine itself, saving code.
AUTOINC/DEC: (Auto-Increment/Auto-Decrement); These instructions use the two memory pointers B
and X to efficiently process a block of data (simplifying “FOR NEXT” or other loop structures in higher
level languages).
2.3.6.4 Bit-Level Control
Bit-level control over many of the microcontroller's I/O ports provides a flexible means to ease layout
concerns and save board space. All members of the COP8 family provide the ability to set, reset and test
any individual bit in the data memory address space, including memory-mapped I/O ports and associated
registers.
2.3.6.5 Register Set
Three memory-mapped pointers handle register indirect addressing and software stack pointer functions.
The memory data pointers allow the option of post-incrementing or post- decrementing with the data
movement instructions (LOAD/EXCHANGE). And 15 memory-mapped registers allow designers to
optimize the precise implementation of certain specific instructions.
Copyright © 2000–2013, Texas Instruments Incorporated Device Information 9
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
SNOS535I OCTOBER 2000REVISED MARCH 2013
www.ti.com
2.3.7 PACKAGING/PIN EFFICIENCY
Real estate and board configuration considerations demand maximum space and pin efficiency,
particularly given today's high integration and small product form factors. Microcontroller users try to avoid
using large packages to get the I/O needed. Large packages take valuable board space and increase
device cost, two trade-offs that microcontroller designs can ill afford.
The COP8 family offers a wide range of packages and does not waste pins.
10 Device Information Copyright © 2000–2013, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
www.ti.com
SNOS535I OCTOBER 2000REVISED MARCH 2013
3 Electrical Specifications
3.1 Absolute Maximum Ratings(1)(2)
Supply Voltage (VCC) 7V
Voltage at Any Pin 0.3V to VCC +0.3V
Total Current into VCC Pin (Source) 200 mA
Total Current out of GND Pin (Sink) 200 mA
Storage Temperature Range 65°C to +140°C
ESD Protection Level 2 kV (Human Body Model)
(1) Absolute maximum ratings indicate limits beyond which damage to the device may occur. DC and AC electrical specifications are not
ensured when operating the device at absolute maximum ratings.
(2) If Military/Aerospace specified devices are required, please contact the TI Sales Office/ Distributors for availability and specifications.
3.2 Electrical Characteristics DC Electrical Characteristics (40°C TA+85°C)
Datasheet min/max specification limits are ensured by design, test, or statistical analysis.
Parameter Conditions Min Typ Max Units
Operating Voltage 2.7 5.5 V
Power Supply Rise Time 10 50 x 106ns
Power Supply Ripple(1) Peak-to-Peak 0.1 VCC V
Supply Current(2)
High Speed Mode
CKI = 10 MHz VCC = 5.5V, tC= 0.5 μs 13.2 mA
CKI = 3.33 MHz VCC = 4.5V, tC= 1.5 μs 6 mA
Dual Clock Mode
CKI = 10 MHz, Low Speed OSC = 32 kHz VCC = 5.5V, tC= 0.5 μs 13.2 mA
CKI = 3.33 MHz, Low Speed OSC = 32 kHz VCC = 4.5V, tC= 1.5 μs 6 mA
Low Speed Mode
Low Speed OSC = 32 kHz VCC = 5.5V 60 103 μA
HALT Current with BOR Disabled(3)
High Speed Mode VCC = 5.5V, CKI = 0 MHz <2 10 μA
Dual Clock Mode VCC = 5.5V, CKI = 0 MHz, Low <5 17 μA
Speed OSC = 32 kHz
Low Speed Mode VCC = 5.5V, CKI = 0 MHz, Low <5 17 μA
Speed OSC = 32 kHz
Idle Current(2)
High Speed Mode
CKI = 10 MHz VCC = 5.5V, tC= 0.5 μs 2.5 mA
CKI = 3.33 MHz VCC = 4.5V, tC= 1.5 μs 1.2 mA
Dual Clock Mode
CKI = 10 MHz, Low Speed OSC = 32 kHz VCC = 5.5V, tC= 0.5 μs 2.5 mA
CKI = 3.33 MHz, Low Speed OSC = 32 kHz VCC = 4.5V, tC= 1.5 μs 1.2 mA
Low Speed Mode
Low Speed OSC = 32 kHz VCC = 5.5V 15 30 μA
(1) Maximum rate of voltage change must be < 0.5 V/ms.
(2) Supply and IDLE currents are measured with CKI driven with a square wave Oscillator, CKO driven 180° out of phase with CKI, inputs
connected to VCC and outputs driven low but not connected to a load.
(3) The HALT mode will stop CKI from oscillating. Measurement of IDD HALT is done with device neither sourcing nor sinking current; with
L. A. B, C, E, F, G0, and G2–G5 programmed as low outputs and not driving a load; all D outputs programmed low and not driving a
load; all inputs tied to VCC; A/D converter and clock monitor and BOR disabled. Parameter refers to HALT mode entered via setting bit 7
of the G Port data register.
Copyright © 2000–2013, Texas Instruments Incorporated Electrical Specifications 11
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
SNOS535I OCTOBER 2000REVISED MARCH 2013
www.ti.com
Electrical Characteristics DC Electrical Characteristics (40°C TA+85°C) (continued)
Datasheet min/max specification limits are ensured by design, test, or statistical analysis.
Parameter Conditions Min Typ Max Units
Supply Current for BOR Feature VCC = 5.5V 45 μA
4.28
High Brownout Trip Level (BOR Enabled) 4.17 4.5 V
Low Brownout Trip Level (BOR Enabled) 2.7 2.78 2.9 V
Input Levels (VIH, VIL)
Logic High 0.8 VCC V
Logic Low 0.16 VCC V
Internal Bias Resistor for the CKI 0.3 1.0 2.5 M
Crystal/Resonator Oscillator
Hi-Z Input Leakage VCC = 5.5V 0.5 +0.5 μA
Input Pullup Current VCC = 5.5V, VIN = 0V 50 210 μA
Port Input Hysteresis 0.25 VCC V
Output Current Levels
D Outputs
Source VCC = 4.5V, VOH = 3.8V 7 mA
VCC = 2.7V, VOH = 1.8V 4 mA
Sink(4) VCC = 4.5V, VOL = 1.0V 10 mA
VCC = 2.7V, VOL = 0.4V 3.5 mA
All Others
Source (Weak Pull-Up Mode) VCC = 4.5V, VOH = 3.8V 10 μA
VCC = 2.7V, VOH = 1.8V 5μA
Source (Push-Pull Mode) VCC = 4.5V, VOH = 3.8V 7 mA
VCC = 2.7V, VOH = 1.8V 4 mA
Sink (Push-Pull Mode)(4) VCC = 4.5V, VOL = 1.0V 10 mA
VCC = 2.7V, VOL = 0.4V 3.5 mA
TRI-STATE Leakage VCC = 5.5V 0.5 +0.5 μA
Allowable Sink Current per Pin 15 mA
Maximum Input Current without Latchup(5) ±200 mA
RAM Retention Voltage, VR(in HALT Mode) 2.0 V
Input Capacitance 7 pF
Load Capacitance on D2 1000 pF
Voltage on G6 to Force Execution from Boot ROM(6) G6 rise time must be slower than 2 x VCC VCC + 7 V
100 ns
G6 Rise Time to Force Execution from Boot ROM 100 nS
Input Current on G6 when Input > VCC VIN = 11V, VCC = 5.5V 500 μA
Flash Memory Data Retention 25°C 100 yrs
Flash Memory Number of Erase/Write Cycles SeeTable 5-12,Typical Flash 105cycles
Memory Endurance
(4) Absolute Maximum Ratings should not be exceeded.
(5) Pins G6 and RESET are designed with a high voltage input network. These pins allow input voltages > VCC and the pins will have sink
current to VCC when biased at voltages > VCC (the pins do not have source current when biased at a voltage below VCC). These two
pins will not latch up. The voltage at the pins must be limited to < 14V. WARNING: Voltages in excess of 14V will cause damage to the
pins. This warning excludes ESD transients.
(6) Vcc must be valid and stable before G6 is raised to a high voltage.
12 Electrical Specifications Copyright © 2000–2013, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
www.ti.com
SNOS535I OCTOBER 2000REVISED MARCH 2013
3.3 Electrical Characteristics AC Electrical Characteristics (40°C TA+85°C)
Datasheet min/max specification limits are ensured by design, test, or statistical analysis.
Parameter Conditions Min Typ Max Units
Instruction Cycle Time (tC)(1)
Crystal/Resonator 4.5V VCC 5.5V 0.5 DC μs
2.7V VCC < 4.5V 1.5 DC μs
Flash Memory Page Erase Time See Table 5-12,Typical Flash 1 ms
Memory Endurance
Flash Memory Mass Erase Time 8 ms
Frequency of MICROWIRE/PLUS in Slave Mode 2 MHz
MICROWIRE/PLUS Setup Time (tUWS) 20 ns
MICROWIRE/PLUS Hold Time (tUWH) 20 ns
MICROWIRE/PLUS Output Propagation Delay (tUPD) 150 ns
Input Pulse Width
Interrupt Input High Time 1 tC
Interrupt Input Low Time 1 tC
Timer 1 Input High Time 1 tC
Timer 1 Input Low Time 1 tC
Timer 2, 3 Input High Time(2) 1 MCLK or tC
Timer 2, 3 Input Low Time(2) 1 MCLK or tC
Output Pulse Width
Timer 2, 3 Output High Time 150 ns
Timer 2, 3 Output Low Time 150 ns
USART Bit Time when using External CKX 6 CKI
periods
USART CKX Frequency when being 2 MHz
Driven by Internal Baud Rate Generator
Reset Pulse Width 1 tC
(1) tC= instruction cycle time.
(2) If timer is in high speed mode, the minimum time is 1 MCLK. If timer is not in high speed mode, the minimum time is 1 tC.
3.4 A/D Converter Electrical Characteristics (40°C TA+85°C unless otherwise noted)
(Single-ended mode only)
Datasheet min/max specification limits are ensured by design, test, or statistical analysis.
Parameter Conditions Min Typ Max Units
Resolution 10 Bits
DNL VCC = 5V ±1 LSB
DNL VCC = 3V,20°C TA±1 LSB
+85°C
INL VCC = 5V ±3 LSB
INL VCC = 3V,20°C TA±4 LSB
+85°C
Offset Error VCC = 5V +2.5, 1 LSB
Offset Error VCC = 3V,20°C TA±2.5 LSB
+85°C
Gain Error VCC = 5V +0.5, 2.5 LSB
Gain Error VCC = 3V,20°C TA±2.5 LSB
+85°C
Input Voltage Range 2.7V VCC < 5.5V 0 VCC V
Analog Input Leakage Current 0.5 µA
Analog Input Resistance(1) 6k
(1) Resistance between the device input and the internal sample and hold capacitance.
Copyright © 2000–2013, Texas Instruments Incorporated Electrical Specifications 13
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
SNOS535I OCTOBER 2000REVISED MARCH 2013
www.ti.com
A/D Converter Electrical Characteristics (40°C TA+85°C unless otherwise noted) (Single-ended mode
only) (continued)
Datasheet min/max specification limits are ensured by design, test, or statistical analysis.
Parameter Conditions Min Typ Max Units
Analog Input Capacitance 7 pF
Conversion Clock Period 4.5V VCC < 5.5V 0.8 30 µs
2.7V VCC < 4.5V 1.2 30 µs
Conversion Time (including S/H Time) 15 A/D
Conversion
Clock
Cycles
Operating Current on AVCC AVCC = 5.5V 0.2 0.6 mA
3.5 DC Electrical Characteristics (40°C TA+125°C)
Datasheet min/max specification limits are ensured by design, test, or statistical analysis.
Parameter Conditions Min Typ Max Units
Operating Voltage 4.5 5.5 V
Power Supply Rise Time 10 50 x 106ns
Power Supply Ripple(1) Peak-to-Peak 0.1 VCC V
Supply Current(2)
High Speed Mode
CKI = 10 MHz VCC = 5.5V, tC= 0.5 μs 14.5 mA
CKI = 3.33 MHz VCC = 4.5V, tC= 1.5 μs 7 mA
Dual Clock Mode 14.5
CKI = 10 MHz, Low Speed OSC = 32 kHz VCC = 5.5V, tC= 0.5 μs mA
CKI = 3.33 MHz, Low Speed OSC = 32 kHz VCC = 4.5V, tC= 1.5 μs 7 mA
Low Speed Mode 110
Low Speed OSC = 32 kHz VCC = 5.5V 65 μA
HALT Current with BOR Disabled(3)
High Speed Mode VCC = 5.5V, CKI = 0 MHz <4 40 μA
Dual Clock Mode VCC = 5.5V, CKI = 0 MHz, Low <9 50 μA
Speed OSC = 32 kHz
Low Speed Mode VCC = 5.5V, CKI = 0 MHz, Low <9 50 μA
Speed OSC = 32 kHz
Idle Current (2)
High Speed Mode
CKI = 10 MHz VCC = 5.5V, tC= 0.5 μs 2.7 mA
Dual Clock Mode
CKI = 10 MHz, Low Speed OSC = 32 kHz VCC = 5.5V, tC= 0.5 μs 2.7 mA
Low Speed Mode
Low Speed OSC = 32 kHz VCC = 5.5V 30 70 μA
Supply Current for BOR Feature VCC = 5.5V 45 μA
High Brownout Trip Level (BOR Enabled) 4.17 4.28 4.5 V
Input Levels (VIH, VIL)
Logic High 0.8 VCC V
Logic Low 0.16 VCC V
(1) Maximum rate of voltage change must be < 0.5 V/ms.
(2) Supply and IDLE currents are measured with CKI driven with a square wave Oscillator, CKO driven 180° out of phase with CKI, inputs
connected to VCC and outputs driven low but not connected to a load.
(3) The HALT mode will stop CKI from oscillating. Measurement of IDD HALT is done with device neither sourcing nor sinking current; with
L. A. B, C, E, F, G0, and G2–G5 programmed as low outputs and not driving a load; all D outputs programmed low and not driving a
load; all inputs tied to VCC; A/D converter and clock monitor and BOR disabled. Parameter refers to HALT mode entered via setting bit 7
of the G Port data register.
14 Electrical Specifications Copyright © 2000–2013, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
www.ti.com
SNOS535I OCTOBER 2000REVISED MARCH 2013
DC Electrical Characteristics (40°C TA+125°C) (continued)
Datasheet min/max specification limits are ensured by design, test, or statistical analysis.
Parameter Conditions Min Typ Max Units
Internal Bias Resistor for the CKI 0.3 1.0 2.5 M
Crystal/Resonator Oscillator
Hi-Z Input Leakage VCC = 5.5V 3 +3 μA
Input Pullup Current VCC = 5.5V, VIN = 0V 40 250 μA
Port Input Hysteresis 0.25 VCC V
Output Current Levels
D Outputs
Source VCC = 4.5V, VOH = 3.8V 6.3 mA
Sink(4) VCC = 4.5V, VOL = 1.0V 9 mA
All Others
Source (Weak Pull-Up Mode) VCC = 4.5V, VOH = 3.8V 9μA
Source (Push-Pull Mode) VCC = 4.5V, VOH = 3.8V 6.3 mA
Sink (Push-Pull Mode)(4) VCC = 4.5V, VOL = 1.0V 9 mA
TRI-STATE Leakage VCC = 5.5V 3 +3 μA
Allowable Sink Current per Pin 1 mA
Maximum Input Current without Latchup(5) ±200 mA
RAM Retention Voltage, VR(in HALT Mode) 2.0 V
Input Capacitance 7 pF
Load Capacitance on D2 1000 pF
Voltage on G6 to Force Execution from Boot ROM(6) G6 rise time must be slower than 2 x VCC VCC + 7 V
100 ns
G6 Rise Time to Force Execution from Boot ROM 100 nS
Input Current on G6 when Input > VCC VIN = 11V, VCC = 5.5V 500 μA
(4) Absolute Maximum Ratings should not be exceeded.
(5) Pins G6 and RESET are designed with a high voltage input network. These pins allow input voltages > VCC and the pins will have sink
current to VCC when biased at voltages > VCC (the pins do not have source current when biased at a voltage below VCC). These two
pins will not latch up. The voltage at the pins must be limited to < (VCC + 7V. WARNING: Voltages in excess of 14V will cause
damage to the pins. This warning excludes ESD transients.
(6) Vcc must be valid and stable before G6 is raised to a high voltage.
3.6 AC Electrical Characteristics (40°C TA+125°C)
Datasheet min/max specification limits are ensured by design, test, or statistical analysis.
Parameter Conditions Min Typ Max Units
Instruction Cycle Time (tC)
Crystal/Resonator(1) 4.5V VCC 5.5V 0.5 DC μs
Output Propagation Delay RL=2.2k, CL= 100 pF
Frequency of MICROWIRE/PLUS in Slave Mode 2 MHz
MICROWIRE/PLUS Setup Time (tUWS) 20 ns
MICROWIRE/PLUS Hold Time (tUWH) 20 ns
MICROWIRE/PLUS Output Propagation Delay (tUPD) 150 ns
Input Pulse Width
Interrupt Input High Time 1 tC
Interrupt Input Low Time 1 tC
Timer 1 Input High Time 1 tC
Timer 1 Input Low Time 1 tC
Timer 2, 3 Input High Time(2) 1 MCLK or tC
Timer 2, 3 Input Low Time(2) 1 MCLK or tC
(1) tC= instruction cycle time.
(2) If timer is in high speed mode, the minimum time is 1 MCLK. If timer is not in high speed mode, the minimum time is 1 tC.
Copyright © 2000–2013, Texas Instruments Incorporated Electrical Specifications 15
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
SNOS535I OCTOBER 2000REVISED MARCH 2013
www.ti.com
AC Electrical Characteristics (40°C TA+125°C) (continued)
Datasheet min/max specification limits are ensured by design, test, or statistical analysis.
Parameter Conditions Min Typ Max Units
Output Pulse Width
Timer 2, 3 Output High Time 150 ns
Timer 2, 3 Output Low Time 150 ns
USART Bit Time when using External CKX 6 CKI
periods
USART CKX Frequency when being Driven by Internal
Baud Rate Generator 2 MHz
Reset Pulse Width 0.5 tC
3.7 A/D Converter Electrical Characteristics (40°C TA+125°C) (Single-ended mode
only)
Datasheet min/max specification limits are ensured by design, test, or statistical analysis.
Parameter Conditions Min Typ Max Units
Resolution 10 Bits
DNL VCC = 5V ±1 LSB
INL VCC = 5V ±3 LSB
Offset Error VCC = 5V +2.5, 1 LSB
Gain Error VCC = 5V +0.5, 2.5 LSB
Input Voltage Range 4.5V VCC < 5.5V 0 VCC V
Analog Input Leakage Current 0.5 µA
Analog Input Resistance(1) 6k
Analog Input Capacitance 7 pF
Conversion Clock Period 4.5V VCC < 5.5V 0.8 30 µs
Conversion Time (including S/H Time) 15 A/D
Conversion
Clock
Cycles
Operating Current on AVCC AVCC = 5.5V 0.2 0.6 mA
(1) Resistance between the device input and the internal sample and hold capacitance.
Figure 3-1. MICROWIRE/PLUS Timing
16 Electrical Specifications Copyright © 2000–2013, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
www.ti.com
SNOS535I OCTOBER 2000REVISED MARCH 2013
4 Pin Descriptions
The COP8CBR/CCR/CDR I/O structure enables designers to reconfigure the microcontroller's I/O
functions with a single instruction. Each individual I/O pin can be independently configured as output pin
low, output high, input with high impedance or input with weak pull-up device. A typical example is the use
of I/O pins as the keyboard matrix input lines. The input lines can be programmed with internal weak pull-
ups so that the input lines read logic high when the keys are all open. With a key closure, the
corresponding input line will read a logic zero since the weak pull-up can easily be overdriven. When the
key is released, the internal weak pull-up will pull the input line back to logic high. This eliminates the need
for external pull-up resistors. The high current options are available for driving LEDs, motors and
speakers. This flexibility helps to ensure a cleaner design, with less external components and lower costs.
Below is the general description of all available pins.
VCC and GND are the power supply pins. All VCC and GND pins must be connected.
Users of the WQFN package are cautioned to be aware that the central metal area and the pin 1 index
mark on the bottom of the package may be connected to GND. See figure below:
Figure 4-1. WQFN Package Bottom View
CKI is the clock input. This can be connected (in conjunction with CKO) to an external crystal circuit to
form a crystal oscillator. See Oscillator Description section.
RESET is the master reset input. See Reset description section.
AVCC is the Analog Supply for A/D converter. It should be connected to VCC externally. This is also the top
of the resistor ladder D/A converter used within the A/D converter.
AGND is the ground pin for the A/D converter. It should be connected to GND externally. This is also the
bottom of the resistor ladder D/A converter used within the A/D converter.
The device contains up to six bidirectional 8-bit I/O ports (A, B, C, E, G and L) and one 4-bit I/O port (F),
where each individual bit may be independently configured as an input (Schmitt trigger inputs on ports L
and G), output or TRI-STATE under program control. Three data memory address locations are allocated
for each of these I/O ports. Each I/O port has three associated 8-bit memory mapped registers, the
CONFIGURATION register, the output DATA register and the Pin input register. (See the memory map for
the various addresses associated with the I/O ports.) Figure 4-2 shows the I/O port configurations. The
DATA and CONFIGURATION registers allow for each port bit to be individually configured under software
control as shown below:
Copyright © 2000–2013, Texas Instruments Incorporated Pin Descriptions 17
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
SNOS535I OCTOBER 2000REVISED MARCH 2013
www.ti.com
DATA
CONFIGURATION Register Port Set-Up
Register
0 0 Hi-Z Input
(TRI-STATE Output)
0 1 Input with Weak Pull-Up
1 0 Push-Pull Zero Output
1 1 Push-Pull One Output
Port A is an 8-bit I/O port. All A pins have Schmitt triggers on the inputs. The 44-pin package does not
have a full 8-bit port and contains some unbonded, floating pads internally on the chip. The binary value
read from these bits is undetermined. The application software should mask out these unknown bits when
reading the Port A register, or use only bit-access program instructions when accessing Port A. These
unconnected bits draw power only when they are addressed (i.e., in brief spikes). Additionally, if Port A is
being used with some combination of digital inputs and analog inputs, the analog inputs will read as
undetermined values and should be masked out by software.
Port A supports the analog inputs for the A/D converter. Port A has the following alternate pin functions:
A7 Analog Channel 7
A6 Analog Channel 6
A5 Analog Channel 5
A4 Analog Channel 4
A3 Analog Channel 3
A2 Analog Channel 2
A1 Analog Channel 1
A0 Analog Channel 0
Port B is an 8-bit I/O port. All B pins have Schmitt triggers on the inputs. If Port B is being used with some
combination of digital inputs and analog inputs, the analog inputs will read as undetermined values. The
application software should mask out these unknown bits when reading the Port B register, or use only bit-
access program instructions when accessing Port B.
Port B supports the analog inputs for the A/D converter. Port B has the following alternate pin functions:
B7 Analog Channel 15 or A/D Input
B6 Analog Channel 14 or Analog Multiplexor Output
B5 Analog Channel 13 or Analog Multiplexor Output
B4 Analog Channel 12
B3 Analog Channel 11
B2 Analog Channel 10
B1 Analog Channel 9
B0 Analog Channel 8
Port C is an 8-bit I/O port. The 44-pin device does not offer Port C. The unavailable pins are not
terminated. A read operation on these unterminated pins will return unpredictable values. On this device,
the associated Port C Data and Configuration registers should not be used. All C pins have Schmitt
triggers on the inputs. Port C draws no power when unbonded.
18 Pin Descriptions Copyright © 2000–2013, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
www.ti.com
SNOS535I OCTOBER 2000REVISED MARCH 2013
Port E is an 8-bit I/O Port. The 44-pin device does not offer Port E. The unavailable pins are not
terminated. A read operation on these unterminated pins will return unpredictable values. On this device,
the associated Port E Data and Configuration registers should not be used. All E pins have Schmitt
triggers on the inputs. Port E draws no power when unbonded.
Port F is a 4-bit I/O Port. All F pins have Schmitt triggers on the inputs.
The 68-pin package has fewer than eight Port F pins, and contains unbonded, floating pads internally on
the chip. The binary values read from these bits are undetermined. The application software should mask
out these unknown bits when reading the Port F register, or use only bit-access program instructions when
accessing Port F. The unconnected bits draw power only when they are addressed (i.e., in brief spikes).
Port G is an 8-bit port. Pin G0, G2–G5 are bi-directional I/O ports. Pin G6 is always a general purpose Hi-
Z input. All pins have Schmitt Triggers on their inputs. Pin G1 serves as the dedicated WATCHDOG
output with weak pull-up if the WATCHDOG feature is selected by the Option register. The pin is a
general purpose I/O if WATCHDOG feature is not selected. If WATCHDOG feature is selected, bit 1 of
the Port G configuration and data register does not have any effect on Pin G1 setup. G7 serves as the
dedicated output pin for the CKO clock output.
Since G6 is an input only pin and G7 is the dedicated CKO clock output pin, the associated bits in the
data and configuration registers for G6 and G7 are used for special purpose functions as outlined below.
Reading the G6 and G7 data bits will return zeros.
The device will be placed in the HALT mode by writing a “1” to bit 7 of the Port G Data Register. Similarly
the device will be placed in the IDLE mode by writing a “1” to bit 6 of the Port G Data Register.
Writing a “1” to bit 6 of the Port G Configuration Register enables the MICROWIRE/PLUS to operate with
the alternate phase of the SK clock. The G7 configuration bit, if set high, enables the clock start up delay
after HALT when the R/C clock configuration is used.
Config. Reg. Data Reg.
G7 CLKDLY HALT
G6 Alternate SK IDLE
Port G has the following alternate features:
G7 CKO Oscillator dedicated output
G6 SI (MICROWIRE/PLUS Serial Data Input)
G5 SK (MICROWIRE/PLUS Serial Clock)
G4 SO (MICROWIRE/PLUS Serial Data Output)
G3 T1A (Timer T1 I/O)
G2 T1B (Timer T1 Capture Input)
G1 WDOUT WATCHDOG and/or Clock Monitor if WATCHDOG enabled, otherwise it is a
general purpose I/O
G0 INTR (External Interrupt Input)
G0 through G3 are also used for In-System Emulation.
Port L is an 8-bit I/O port. All L-pins have Schmitt triggers on the inputs.
Port L supports the Multi-Input Wake-up feature on all eight pins. Port L has the following alternate pin
functions:
L7 Multi-Input Wake-up or T3B (Timer T3B Input)
L6 Multi-Input Wake-up or T3A (Timer T3A Input/Output)
L5 Multi-Input Wake-up or T2B (Timer T2B Input)
Copyright © 2000–2013, Texas Instruments Incorporated Pin Descriptions 19
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
SNOS535I OCTOBER 2000REVISED MARCH 2013
www.ti.com
L4 Multi-input Wake-up or T2A (Timer T2A Input/Output)
L3 Multi-Input Wake-up and/or RDX (USART Receive)
L2 Multi-Input Wake-up or TDX (USART Transmit)
L1 Multi-Input Wake-up and/or CKX (USART Clock) (Low Speed Oscillator Output)
L0 Multi-Input Wake-up (Low Speed Oscillator Input)
Port D is an 8-bit output port that is preset high when RESET goes low. The user can tie two or more D
port outputs (except D2) together in order to get a higher drive.
NOTE
Care must be exercised with the D2 pin operation. At RESET, the external loads on this pin
must ensure that the output voltages stay above 0.7 VCC to prevent the chip from entering
special modes. Also keep the external loading on D2 to less than 1000 pF.
Figure 4-2. I/O Port Configurations
Figure 4-3. I/O Port Configurations—Output Mode
20 Pin Descriptions Copyright © 2000–2013, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
www.ti.com
SNOS535I OCTOBER 2000REVISED MARCH 2013
Figure 4-4. I/O Port Configurations—Input Mode
4.1 EMULATION CONNECTION
Connection to the emulation system is made via a 2 x 7 connector which interrupts the continuity of the
RESET, G0, G1, G2 and G3 signals between the COP8 device and the rest of the target system (as
shown in Figure 4-5). This connector can be designed into the production pc board and can be replaced
by jumpers or signal traces when emulation is no longer necessary. The emulator will replicate all
functions of G0 - G3 and RESET. For proper operation, no connection should be made on the device side
of the emulator connector.
Figure 4-5. Emulation Connection
Copyright © 2000–2013, Texas Instruments Incorporated Pin Descriptions 21
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
SNOS535I OCTOBER 2000REVISED MARCH 2013
www.ti.com
5 Functional Description
This table assumes that the control flag MSEL is set.
The architecture of the device is a modified Harvard architecture. With the Harvard architecture, the
program memory (Flash) is separate from the data store memory (RAM). Both Program Memory and Data
Memory have their own separate addressing space with separate address buses. The architecture, though
based on the Harvard architecture, permits transfer of data from Flash Memory to RAM.
5.1 CPU REGISTERS
The CPU can do an 8-bit addition, subtraction, logical or shift operation in one instruction (tC) cycle time.
There are six CPU registers:
A is the 8-bit Accumulator Register
PC is the 15-bit Program Counter Register
PU is the upper 7 bits of the program counter (PC)
PL is the lower 8 bits of the program counter (PC)
B is an 8-bit RAM address pointer, which can be optionally post auto incremented or decremented.
X is an 8-bit alternate RAM address pointer, which can be optionally post auto incremented or
decremented.
S is the 8-bit Data Segment Address Register used to extend the lower half of the address range (00 to
7F) into 256 data segments of 128 bytes each.
SP is the 8-bit stack pointer, which points to the subroutine/interrupt stack (in RAM). With reset the SP is
initialized to RAM address 06F Hex. The SP is decremented as items are pushed onto the stack. SP
points to the next available location on the stack.
All the CPU registers are memory mapped with the exception of the Accumulator (A) and the Program
Counter (PC).
5.2 PROGRAM MEMORY
The program memory consists of 32,768 bytes of Flash Memory. These bytes may hold program
instructions or constant data (data tables for the LAID instruction, jump vectors for the JID instruction, and
interrupt vectors for the VIS instruction). The program memory is addressed by the 15-bit program counter
(PC). All interrupts in the device vector to program memory location 00FF Hex. The program memory
reads 00 Hex in the erased state. Program execution starts at location 0 after RESET.
If a Return instruction is executed when the SP contains 6F (hex), instruction execution will continue from
Program Memory location 7FFF (hex). If location 7FFF is accessed by an instruction fetch, the Flash
Memory will return a value of 00. This is the opcode for the INTR instruction and will cause a Software
Trap.
For the purpose of erasing and rewriting the Flash Memory, it is organized in pages of 128 bytes.
5.3 DATA MEMORY
The data memory address space includes the on-chip RAM and data registers, the I/O registers
(Configuration, Data and Pin), the control registers, the MICROWIRE/PLUS SIO shift register, and the
various registers, and counters associated with the timers and the USART (with the exception of the IDLE
timer). Data memory is addressed directly by the instruction or indirectly by the B, X and SP pointers.
22 Functional Description Copyright © 2000–2013, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
www.ti.com
SNOS535I OCTOBER 2000REVISED MARCH 2013
The data memory consists of 1024 bytes of RAM. Sixteen bytes of RAM are mapped as “registers” at
addresses 0F0 to 0FF Hex. These registers can be loaded immediately, and also decremented and tested
with the DRSZ (decrement register and skip if zero) instruction. The memory pointer registers X, SP, B
and S are memory mapped into this space at address locations 0FC to 0FF Hex respectively, with the
other registers being available for general usage.
The instruction set permits any bit in memory to be set, reset or tested. All I/O and registers (except A and
PC) are memory mapped; therefore, I/O bits and register bits can be directly and individually set, reset
and tested. The accumulator (A) bits can also be directly and individually tested.
Note: RAM contents are undefined upon power-up.
5.4 DATA MEMORY SEGMENT RAM EXTENSION
Data memory address 0FF is used as a memory mapped location for the Data Segment Address Register
(S).
The data store memory is either addressed directly by a single byte address within the instruction, or
indirectly relative to the reference of the B, X, or SP pointers (each contains a single-byte address). This
single-byte address allows an addressing range of 256 locations from 00 to FF hex. The upper bit of this
single-byte address divides the data store memory into two separate sections as outlined previously. With
the exception of the RAM register memory from address locations 00F0 to 00FF, all RAM memory is
memory mapped with the upper bit of the single-byte address being equal to zero. This allows the upper
bit of the single-byte address to determine whether or not the base address range (from 0000 to 00FF) is
extended. If this upper bit equals one (representing address range 0080 to 00FF), then address extension
does not take place. Alternatively, if this upper bit equals zero, then the data segment extension register S
is used to extend the base address range (from 0000 to 007F) from XX00 to XX7F, where XX represents
the 8 bits from the S register. Thus the 128-byte data segment extensions are located from addresses
0100 to 017F for data segment 1, 0200 to 027F for data segment 2, etc., up to FF00 to FF7F for data
segment 255. The base address range from 0000 to 007F represents data segment 0.
Figure 5-1 illustrates how the S register data memory extension is used in extending the lower half of the
base address range (00 to 7F hex) into 256 data segments of 128 bytes each, with a total addressing
range of 32 kbytes from XX00 to XX7F. This organization allows a total of 256 data segments of 128 bytes
each with an additional upper base segment of 128 bytes. Furthermore, all addressing modes are
available for all data segments. The S register must be changed under program control to move from one
data segment (128 bytes) to another. However, the upper base segment (containing the 16 memory
registers, I/O registers, control registers, etc.) is always available regardless of the contents of the S
register, since the upper base segment (address range 0080 to 00FF) is independent of data segment
extension.
The instructions that utilize the stack pointer (SP) always reference the stack as part of the base segment
(Segment 0), regardless of the contents of the S register. The S register is not changed by these
instructions. Consequently, the stack (used with subroutine linkage and interrupts) is always located in the
base segment. The stack pointer will be initialized to point at data memory location 006F as a result of
reset.
The 128 bytes of RAM contained in the base segment are split between the lower and upper base
segments. The first 112 bytes of RAM are resident from address 0000 to 006F in the lower base segment,
while the remaining 16 bytes of RAM represent the 16 data memory registers located at addresses 00F0
to 00FF of the upper base segment. No RAM is located at the upper sixteen addresses (0070 to 007F) of
the lower base segment.
Additional RAM beyond these initial 128 bytes, however, will always be memory mapped in groups of 128
bytes (or less) at the data segment address extensions (XX00 to XX7F) of the lower base segment. The
additional 892 bytes of RAM in this device are memory mapped at address locations 0100 to 017F
through 0700 to 077F hex.
Copyright © 2000–2013, Texas Instruments Incorporated Functional Description 23
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
SNOS535I OCTOBER 2000REVISED MARCH 2013
www.ti.com
Figure 5-1. RAM Organization
5.4.1 Virtual EEPROM
The Flash memory and the User ISP functions (see Section 5.7), provide the user with the capability to
use the flash program memory to back up user defined sections of RAM. This effectively provides the user
with the same nonvolatile data storage as EEPROM. Management, and even the amount of memory
used, are the responsibility of the user, however the flash memory read and write functions have been
provided in the boot ROM.
One typical method of using the Virtual EEPROM feature would be for the user to copy the data to RAM
during system initialization, periodically, and if necessary, erase the page of Flash and copy the contents
of the RAM back to the Flash.
5.5 OPTION REGISTER
The Option register, located at address 0x7FFF in the Flash Program Memory, is used to configure the
user selectable security, WATCHDOG, and HALT options. The register can be programmed only in
external Flash Memory programming or ISP Programming modes. Therefore, the register must be
programmed at the same time as the program memory. The contents of the Option register shipped from
the factory read 00 Hex.
The format of the Option register is as follows:
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
WATCH
Reserved SECURITY Reserved HALT FLEX
DOG
Bits 7, 6 These bits are reserved and must be 0.
Bit 5
= 1 Security enabled. Flash Memory read and write are not allowed except in User ISP/Virtual E2
commands. Mass Erase is allowed.
= 0 Security disabled. Flash Memory read and write are allowed.
Bits 4, 3 These bits are reserved and must be 0.
24 Functional Description Copyright © 2000–2013, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
www.ti.com
SNOS535I OCTOBER 2000REVISED MARCH 2013
Bit 2
= 1 WATCHDOG feature disabled. G1 is a general purpose I/O.
= 0 WATCHDOG feature enabled. G1 pin is WATCHDOG output with weak pullup.
Bit 1
= 1 HALT mode disabled.
= 0 HALT mode enabled.
Bit 0
= 1 Execution following RESET will be from Flash Memory.
= 0 Flash Memory is erased. Execution following RESET will be from Boot ROM with the
MICROWIRE/PLUS ISP routines.
The COP8 assembler defines a special ROM section type, CONF, into which the Option Register data
may be coded. The Option Register is programmed automatically by programmers that are certified by TI.
The user needs to ensure that the FLEX bit will be set when the device is programmed.
The following examples illustrate the declaration of the Option Register.
Syntax:
[label:].sect config, conf
.db value ;1 byte,
;configures
;options
.endsect
Example: The following sets a value in the Option Register and User Identification for a COP8CBR9HVA7.
The Option Register bit values shown select options: Security disabled, WATCHDOG enabled HALT
mode enabled and execution will commence from Flash Memory.
.chip 8CBR
.sect option, conf
.db 0x01 ;wd, halt, flex
.endsect
...
.end start
Note: All programmers certified for programming this family of parts will support programming of the
Option Register. Please contact TI or your device programmer supplier for more information.
5.6 SECURITY
The device has a security feature which, when enabled, prevents external reading of the Flash program
memory. The security bit in the Option Register determines, whether security is enabled or disabled. If the
security feature is disabled, the contents of the internal Flash Memory may be read by external
programmers or by the built in MICROWIRE/PLUS serial interface ISP. Security must be enforced by
the user when the contents of the Flash Memory are accessed via the user ISP or Virtual EEPROM
capability.
If the security feature is enabled, then any attempt to externally read the contents of the Flash Memory will
result in the value FF (hex) being read from all program locations (except the Option Register). In addition,
with the security feature enabled, the write operation to the Flash program memory and Option Register is
inhibited. Page Erases are also inhibited when the security feature is enabled. The Option Register is
readable regardless of the state of the security bit by accessing location FFFF (hex). Mass Erase
Operations are possible regardless of the state of the security bit.
The security bit can be erased only by a Mass Erase of the entire contents of the Flash unless Flash
operation is under the control of User ISP functions.
Copyright © 2000–2013, Texas Instruments Incorporated Functional Description 25
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
SNOS535I OCTOBER 2000REVISED MARCH 2013
www.ti.com
NOTE
The actual memory address of the Option Register is 7FFF (hex), however the
MICROWIRE/PLUS ISP routines require the address FFFF (hex) to be used to read the
Option Register when the Flash Memory is secured.
The entire Option Register must be programmed at one time and cannot be rewritten without first erasing
the entire last page of Flash Memory.
5.7 RESET
The device is initialized when the RESET pin is pulled low or the On-chip Brownout Reset is activated.
The Brownout Reset feature is not available on the COP8CDR9.
Figure 5-2. Reset Logic
The following occurs upon initialization:
Port A: TRI-STATE (High Impedance Input)
Port B: TRI-STATE (High Impedance Input)
Port C: TRI-STATE (High Impedance Input)
Port D: HIGH
Port E: TRI-STATE (High Impedance Input)
Port F: TRI-STATE (High Impedance Input)
Port G: TRI-STATE (High Impedance Input). Exceptions: If Watchdog is enabled, then G1 is
Watchdog output. G0 and G2 have their weak pull-up enabled during RESET.
Port L: TRI-STATE (High Impedance Input)
PC: CLEARED to 0000
PSW, CNTRL and ICNTRL registers: CLEARED
SIOR:
UNAFFECTED after RESET with power already applied
RANDOM after RESET at power-on
T2CNTRL: CLEARED
T3CNTRL: CLEARED
HSTCR: CLEARED
ITMR: Cleared except Bit 6 (HSON) = 1
Accumulator, Timer 1, Timer 2 and Timer 3:
RANDOM after RESET
WKEN, WKEDG: CLEARED
WKPND: RANDOM
26 Functional Description Copyright © 2000–2013, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
www.ti.com
SNOS535I OCTOBER 2000REVISED MARCH 2013
SP (Stack Pointer):
Initialized to RAM address 06F Hex
B and X Pointers:
UNAFFECTED after RESET with power already applied
RANDOM after RESET at power-on
S Register: CLEARED
RAM:
UNAFFECTED after RESET with power already applied
RANDOM after RESET at power-on
USART:
PSR, ENU, ENUR, ENUI: Cleared except the TBMT bit
which is set to one.
ANALOG TO DIGITAL CONVERTER:
ENAD: CLEARED
ADRSTH: RANDOM
ADRSTL: RANDOM
ISP CONTROL:
ISPADLO: CLEARED
ISPADHI: CLEARED
PGMTIM: PRESET TO VALUE FOR 10 MHz CKI
WATCHDOG (if enabled):
The device comes out of reset with both the WATCHDOG logic and the Clock Monitor
detector armed, with the WATCHDOG service window bits set and the Clock Monitor bit set.
The WATCHDOG and Clock Monitor circuits are inhibited during reset. The WATCHDOG
service window bits being initialized high default to the maximum WATCHDOG service
window of 64k T0 clock cycles. The Clock Monitor bit being initialized high will cause a Clock
Monitor error following reset if the clock has not reached the minimum specified frequency at
the termination of reset. A Clock Monitor error will cause an active low error output on pin
G1. This error output will continue until 16–32 T0 clock cycles following the clock frequency
reaching the minimum specified value, at which time the G1 output will go high.
5.7.1 External Reset
The RESET input when pulled low initializes the device. The RESET pin must be held low for a minimum
of one instruction cycle to ensure a valid reset. During Power-Up initialization, the user must ensure that
the RESET pin of a device without the Brownout Reset feature is held low until the device is within the
specified VCC voltage. Any rising edge on the RESET pin while VCC is below the specified operating range
may cause unpredictable results. An R/C circuit on the RESET pin with a delay 5 times (5x) greater than
the power supply rise time is recommended. Reset should also be wide enough to ensure crystal start-up
upon Power-Up.
RESET may also be used to cause an exit from the HALT mode.
A recommended reset circuit for this device is shown in Figure 5-3.
Copyright © 2000–2013, Texas Instruments Incorporated Functional Description 27
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
SNOS535I OCTOBER 2000REVISED MARCH 2013
www.ti.com
Figure 5-3. Reset Circuit Using External Reset
5.7.2 On-Chip Brownout Reset
When enabled, the device generates an internal reset as VCC rises. While VCC is less than the specified
brownout voltage (Vbor), the device is held in the reset condition and the Idle Timer is preset with 00Fx
(240–256 tC). When VCC reaches a value greater than Vbor, the Idle Timer starts counting down. Upon
underflow of the Idle Timer, the internal reset is released and the device will start executing instructions.
This internal reset will perform the same functions as external reset. Once VCC is above the Vbor and this
initial Idle Timer time-out takes place, instruction execution begins and the Idle Timer can be used
normally. If, however, VCC drops below the selected Vbor, an internal reset is generated, and the Idle Timer
is preset with 00Fx. The device now waits until VCC is greater than Vbor and the countdown starts over.
When enabled, the functional operation of the device, at frequency, is ensured down to the Vbor level.
Figure 5-4. Brownout Reset Operation
One exception to the above is that the brownout circuit will insert a delay of approximately 3 ms on power
up or any time the VCC drops below a voltage of about 1.8V. The device will be held in Reset for the
duration of this delay before the Idle Timer starts counting the 240 to 256 tC. This delay starts as soon as
the VCC rises above the trigger voltage (approximately 1.8V). This behavior is shown in Figure 5-4.
In Case 1, VCC rises from 0V and the on-chip RESET is undefined until the supply is greater than
approximately 1.0V. At this time the brownout circuit becomes active and holds the device in RESET. As
the supply passes a level of about 1.8V, a delay of about 3 ms (td) is started and the Idle Timer is preset
to a value between 00F0 and 00FF (hex). Once VCC is greater than Vbor and tdhas expired, the Idle Timer
is allowed to count down (tid).
28 Functional Description Copyright © 2000–2013, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
www.ti.com
SNOS535I OCTOBER 2000REVISED MARCH 2013
Case 2 shows a subsequent dip in the supply voltage which goes below the approximate 1.8V level. As
VCC drops below Vbor, the internal RESET signal is asserted. When VCC rises back above the 1.8V level, td
is started. Since the power supply rise time is longer for this case, tdhas expired before VCC rises above
Vbor and tid starts immediately when VCC is greater than Vbor.
Case 3 shows a dip in the supply where VCC drops below Vbor, but not below 1.8V. On-chip RESET is
asserted when VCC goes below Vbor and tid starts as soon as the supply goes back above Vbor.
If the Brownout Reset feature is enabled, the internal reset will not be turned off until the Idle Timer
underflows. The internal reset will perform the same functions as external reset. The device is ensured to
operate at the specified frequency down to the specified brownout voltage. After the underflow, the logic is
designed such that no additional internal resets occur as long as VCC remains above the brownout
voltage.
The device is relatively immune to short duration negative-going VCC transients (glitches). It is essential
that good filtering of VCC be done to ensure that the brownout feature works correctly. Power supply
decoupling is vital even in battery powered systems.
There are two optional brownout voltages. The part numbers for the three versions of this device are:
COP8CBR, Vbor = low voltage range
COP8CCR, Vbor = high voltage range
COP8CDR, BOR is disabled.
Refer to the device specifications for the actual Vbor voltages.
High brownout voltage devices are ensured to operate at 10MHz down to the brownout voltage. Low
brownout voltage devices are ensured to operate at 3.33MHz down to the brownout voltage. Devices are
not ensured to operate at 10MHz down to the low brownout voltage.
Under no circumstances should the RESET pin be allowed to float. If the on-chip Brownout Reset feature
is being used, the RESET pin should be connected directly to VCC. The RESET input may also be
connected to an external pull-up resistor or to other external circuitry. Any rising edge on the RESET pin
while VCC is below the specified operating range may cause unpredictable results. The output of the
brownout reset detector will always preset the Idle Timer to a value between 00F0 and 00FF (240 to 256
tC). At this time, the internal reset will be generated.
If the BOR feature is disabled, then no internal resets are generated and the Idle Timer will power-up with
an unknown value. In this case, the external RESET must be used. When BOR is disabled, this on-chip
circuitry is disabled and draws no DC current.
The contents of data registers and RAM are unknown following the on-chip reset.
Figure 5-5. Reset Circuit Using Power-On Reset
5.8 OSCILLATOR CIRCUITS
The device has two crystal oscillators to facilitate low power operation while maintaining throughput when
required. Further information on the use of the two oscillators is found in Power Saving Features. The low
speed oscillator utilizes the L0 and L1 port pins. References in the following text to CKI will also apply to
L0 and references to G7/CKO will also apply to L1.
Copyright © 2000–2013, Texas Instruments Incorporated Functional Description 29
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
SNOS535I OCTOBER 2000REVISED MARCH 2013
www.ti.com
5.8.1 Oscillator
CKI is the clock input while G7/CKO is the clock generator output to the crystal. An on-chip bias resistor
connected between CKI and CKO is provided to reduce system part count. The value of the resistor is in
the range of 0.5M to 2M (typically 1.0M). Table 5-1 shows the component values required for various
standard crystal values. Resistor R2 is on-chip, for the high speed oscillator, and is shown for reference.
Figure 5-6 and Figure 5-6 shows the crystal oscillator connection diagrams. A ceramic resonator of the
required frequency may be used in place of a crystal if the accuracy requirements are not quite as strict.
High Speed Oscillator Low Speed Oscillator
Figure 5-6. Crystal Oscillator
Table 5-1. Crystal Oscillator Configuration, TA= 25°C, VCC = 5V(1)
CKI Freq.
R1 (kΩ) R2 (MΩ) C1 (pF) C2 (pF) (MHz)
0 On Chip 18 18 10
0 On Chip 18 18 5
0 On Chip 18–36 18–36 1
5.6 On Chip 100 100–156 0.455
0 20 ** ** 32.768 kHz*
(1) *Applies to connection to low speed oscillator on port pins L0 and L1 only.
**See Note below.
The crystal and other oscillator components should be placed in close proximity to the CKI and CKO pins
to minimize printed circuit trace length.
The values for the external capacitors should be chosen to obtain the manufacturer's specified load
capacitance for the crystal when combined with the parasitic capacitance of the trace, socket, and
package (which can vary from 0 to 8 pF). The guideline in choosing these capacitors is:
Manufacturer's specified load cap = (C1* C2) / (C1+ C2)+Cparasitic
C2can be trimmed to obtain the desired frequency. C2should be less than or equal to C1.
NOTE
The low power design of the low speed oscillator makes it extremely sensitive to board
layout and load capacitance. The user should place the crystal and load capacitors within
1cm. of the device and must ensure that the above equation for load capacitance is strictly
followed. If these conditions are not met, the application may have problems with startup of
the low speed oscillator.
30 Functional Description Copyright © 2000–2013, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
www.ti.com
SNOS535I OCTOBER 2000REVISED MARCH 2013
Table 5-2. Startup Times
CKI Frequency Startup Time
10 MHz 1–10 ms
3.33 MHz 3–10 ms
1 MHz 3–20 ms
455 kHz 10–30 ms
32 kHz (low speed oscillator) 2–5 sec
5.8.2 Clock Doubler
This device contains a frequency doubler that doubles the frequency of the oscillator selected to operate
the main microcontroller core. The details of how to select either the high speed oscillator or low speed
oscillator are described in, Power Saving Features. When the high speed oscillator connected to CKI
operates at 10 MHz, the internal clock frequency is 20 MHz, resulting in an instruction cycle time of 0.5 µs.
When the 32 kHz oscillator connected to L0 and L1 is selected, the internal clock frequency is 64 kHz,
resulting in an instruction cycle of 152.6 µs. The output of the clock doubler is called MCLK and is
referenced in many places within this document.
5.9 CONTROL REGISTERS
5.9.1 CNTRL Register (Address X00EE)
T1C3 T1C2 T1C1 T1C0 MSEL IEDG SL1 SL0
Bit 7 Bit 0
The Timer1 (T1) and MICROWIRE/PLUS control register contains the following bits:
T1C3 Timer T1 mode control bit
T1C2 Timer T1 mode control bit
T1C1 Timer T1 mode control bit
T1C0 Timer T1 Start/Stop control in timer modes 1 and 2. T1 Underflow Interrupt Pending Flag in
timer mode 3
MSEL Selects G5 and G4 as MICROWIRE/PLUS signals SK and SO respectively
IEDG External interrupt edge polarity select (0 = Rising edge, 1 = Falling edge)
SL1 & SL0 Select the MICROWIRE/PLUS clock divide by (00 = 2, 01 = 4, 1x = 8)
5.9.2 PSW Register (Address X00EF)
HC C T1PNDA T1ENA EXPND BUSY EXEN GIE
Bit 7 Bit 0
The PSW register contains the following select bits:
HC Half Carry Flag
CCarry Flag
T1PNDA Timer T1 Interrupt Pending Flag (Autoreload RA in mode 1, T1 Underflow in Mode 2, T1A
capture edge in mode 3)
T1ENA Timer T1 Interrupt Enable for Timer Underflow or T1A Input capture edge
EXPND External interrupt pending
Copyright © 2000–2013, Texas Instruments Incorporated Functional Description 31
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
SNOS535I OCTOBER 2000REVISED MARCH 2013
www.ti.com
BUSY MICROWIRE/PLUS busy shifting flag
EXEN Enable external interrupt
GIE Global interrupt enable (enables interrupts)
The Half-Carry flag is also affected by all the instructions that affect the Carry flag. The SC (Set Carry)
and R/C (Reset Carry) instructions will respectively set or clear both the carry flags. In addition to the SC
and R/C instructions, ADC, SUBC, RRC and RLC instructions affect the Carry and Half Carry flags.
5.9.3 ICNTRL Register (Address X00E8)
Unused LPEN T0PND T0EN µWPND µWEN T1PNDB T1ENB
Bit 7 Bit 0
The ICNTRL register contains the following bits:
LPEN L Port Interrupt Enable (Multi-Input Wake-up/Interrupt)
T0PND Timer T0 Interrupt pending
T0EN Timer T0 Interrupt Enable (Bit 12 toggle)
μWPND MICROWIRE/PLUS interrupt pending
μWEN Enable MICROWIRE/PLUS interrupt
T1PNDB Timer T1 Interrupt Pending Flag for T1B capture edge
T1ENB Timer T1 Interrupt Enable for T1B Input capture edge
5.9.4 T2CNTRL Register (Address X00C6)
T2C3 T2C2 T2C1 T2C0 T2PNDA T2ENA T2PNDB T2ENB
Bit 7 Bit 0
The T2CNTRL register contains the following bits:
T2C3 Timer T2 mode control bit
T2C2 Timer T2 mode control bit
T2C1 Timer T2 mode control bit
T2C0 Timer T2 Start/Stop control in timer modes 1 and 2, Timer T2 Underflow Interrupt Pending
Flag in timer mode 3
T2PNDA Timer T2 Interrupt Pending Flag (Autoreload RA in mode 1, T2 Underflow in mode 2, T2A
capture edge in mode 3)
T2ENA Timer T2 Interrupt Enable for Timer Underflow or T2A Input capture edge
T2PNDB Timer T2 Interrupt Pending Flag for T2B capture edge
T2ENB Timer T2 Interrupt Enable for T2B Input capture edge
5.9.5 T3CNTRL Register (Address X00B6)
T3C3 T3C2 T3C1 T3C0 T3PNDA T3ENA T3PNDB T3ENB
Bit 7 Bit 0
32 Functional Description Copyright © 2000–2013, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
www.ti.com
SNOS535I OCTOBER 2000REVISED MARCH 2013
The T3CNTRL register contains the following bits:
T3C3 Timer T3 mode control bit
T3C2 Timer T3 mode control bit
T3C1 Timer T3 mode control bit
T3C0 Timer T3 Start/Stop control in timer modes 1 and 2, Timer T3 Underflow Interrupt Pending
Flag in timer mode 3
T3PNDA Timer T3 Interrupt Pending Flag (Autoreload RA in mode 1, T3 Underflow in mode 2, T3A
capture edge in mode 3)
T3ENA Timer T3 Interrupt Enable for Timer Underflow or T3A Input capture edge
T3PNDB Timer T3 Interrupt Pending Flag for T3B capture edge
T3ENB Timer T3 Interrupt Enable for T3B Input capture edge
5.9.6 HSTCR Register (Address X00AF)
Reserved T3HS T2HS
Bit 7 Bit 0
The HSTCR register contains the following bits:
T3HS Places Timer T3 in High Speed Mode.
T2HS Places Timer T2 in High Speed Mode.
5.9.7 ITMR Register (Address X00CF)
CCKS
LSON HSON DCEN RSVD ITSEL2 ITSEL1 ITSEL0
EL
Bit 7 Bit 0
The ITMR register contains the following bits:
LSON Turns the low speed oscillator on or off.
HSON Turns the high speed oscillator on or off.
DCEN Selects the high speed oscillator or the low speed oscillator as the Idle Timer Clock.
CCKSEL Selects the high speed oscillator or the low speed oscillator as the primary CPU clock.
RSVD This bit is reserved and must be 0.
ITSEL2 Idle Timer period select bit.
ITSEL1 Idle Timer period select bit.
ITSEL0 Idle Timer period select bit.
5.9.8 ENAD Register (Address X00CB)
ADCH3 ADCH2 ADCH1 ADCH0 ADMOD MUX PSC ADBSY
Channel Select Mode Select Mux Out Prescale Busy
Bit 7 Bit 0
Copyright © 2000–2013, Texas Instruments Incorporated Functional Description 33
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
SNOS535I OCTOBER 2000REVISED MARCH 2013
www.ti.com
The ENAD register contains the following bits:
ADCH3 ADC channel select bit
ADCH2 ADC channel select bit
ADCH1 ADC channel select bit
ADCH0 ADC channel select bit
ADMOD Places the ADC in single-ended or differential mode.
MUX Enables the ADC multiplexor output.
PSC Switches the ADC clock between a divide by one or a divide by sixteen of MCLK.
ADBSY Signifies that the ADC is currently busy performing a conversion. When set by the user,
starts a conversion.
5.10 In-System Programming
5.10.1 INTRODUCTION
This device provides the capability to program the program memory while installed in an application board.
This feature is called In System Programming (ISP). It provides a means of ISP by using the
MICROWIRE/PLUS, or the user can provide his own, customized ISP routine. The factory installed ISP
uses the MICROWIRE/PLUS port. The user can provide his own ISP routine that uses any of the
capabilities of the device, such as USART, parallel port, etc.
5.10.2 FUNCTIONAL DESCRIPTION
The organization of the ISP feature consists of the user flash program memory, the factory boot ROM, and
some registers dedicated to performing the ISP function. See Figure 5-7 for a simplified block diagram.
The factory installed ISP that uses MICROWIRE/PLUS is located in the Boot ROM. The size of the Boot
ROM is 1K bytes and also contains code to facilitate in system emulation capability. If a user chooses to
write his own ISP routine, it must be located in the flash program memory.
Figure 5-7. Block Diagram of ISP
34 Functional Description Copyright © 2000–2013, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
www.ti.com
SNOS535I OCTOBER 2000REVISED MARCH 2013
As described in Option Register, there is a bit, FLEX, that controls whether the device exits RESET
executing from the flash memory or the Boot ROM. The user must program the FLEX bit as appropriate
for the application. In the erased state, the FLEX bit = 0 and the device will power-up executing from Boot
ROM. When FLEX = 0, this assumes that either the MICROWIRE/PLUS ISP routine or external
programming is being used to program the device. If using the MICROWIRE/PLUS ISP routine, the
software in the boot ROM will monitor the MICROWIRE/PLUS for commands to program the flash
memory. When programming the flash program memory is complete, the FLEX bit will have to be
programmed to a 1 and the device will have to be reset, either by pulling external Reset to ground or by a
MICROWIRE/PLUS ISP EXIT command, before execution from flash program memory will occur.
If FLEX = 1, upon exiting Reset, the device will begin executing from location 0000 in the flash program
memory. The assumption, here, is that either the application is not using ISP, is using MICROWIRE/PLUS
ISP by jumping to it within the application code, or is using a customized ISP routine. If a customized ISP
routine is being used, then it must be programmed into the flash memory by means of the
MICROWIRE/PLUS ISP or external programming as described in the preceding paragraph.
5.10.3 REGISTERS
There are six registers required to support ISP: Address Register Hi byte (ISPADHI), Address Register
Low byte (ISPADLO), Read Data Register (ISPRD), Write Data Register (ISPWR), Write Timing Register
(PGMTIM), and the Control Register (ISPCNTRL). The ISPCNTRL Register is not available to the user.
5.10.3.1 ISP Address Registers
The address registers (ISPADHI & ISPADLO) are used to specify the address of the byte of data being
written or read. For page erase operations, the address of the beginning of the page should be loaded.
For mass erase operations, 0000 must be placed into the address registers. When reading the Option
register, FFFF (hex) should be placed into the address registers. Registers ISPADHI and ISPADLO are
cleared to 00 on Reset. These registers can be loaded from either flash program memory or Boot ROM
and must be maintained for the entire duration of the operation.
NOTE
The actual memory address of the Option Register is 7FFF (hex), however the
MICROWIRE/PLUS ISP routines require the address FFFF (hex) to be used to read the
Option Register when the Flash Memory is secured.
Table 5-3. High Byte of ISP Address
ISPADHi
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Addr 15 Addr 14 Addr 13 Addr 12 Addr 11 Addr 10 Addr 9 Addr 8
Table 5-4. Low Byte of ISP AddressThis table assumes that the control flag
MSEL is set.
ISPADLO
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Addr 7 Addr 6 Addr 5 Addr 4 Addr 3 Addr 2 Addr 1 Addr 0
5.10.3.2 ISP Read Data Register
The Read Data Register (ISPRD) contains the value read back from a read operation. This register can be
accessed from either flash program memory or Boot ROM. This register is undefined on Reset.
Copyright © 2000–2013, Texas Instruments Incorporated Functional Description 35
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
SNOS535I OCTOBER 2000REVISED MARCH 2013
www.ti.com
Table 5-5. ISP Read Data Register
ISPRD
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0
5.10.3.3 ISP Write Data RegisterThis table assumes that the control flag MSEL is set.
The Write Data Register (ISPWR) contains the data to be written into the specified address. This register
is undetermined on Reset. This register can be accessed from either flash program memory or Boot ROM.
The Write Data register must be maintained for the entire duration of the operation.
Table 5-6. ISP Write Data Register
ISPWR
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0
5.10.3.4 ISP Write Timing Register
The Write Timing Register (PGMTIM) is used to control the width of the timing pulses for write and erase
operations. The value to be written into this register is dependent on the frequency of CKI and is shown in
Table 5-7. This register must be written before any write or erase operation can take place. It only needs
to be loaded once, for each value of CKI frequency. This register can be loaded from either flash program
memory or Boot ROM and must be maintained for the entire duration of the operation. The
MICROWIRE/PLUS ISP routine that is resident in the boot ROM requires that this Register be defined
prior to any access to the Flash memory. Refer to Microwire for more information on available ISP
commands. On Reset, the PGMTIM register is loaded with the value that corresponds to 10 MHz
frequency for CKI.
Table 5-7. PGMTIM Register Format
PGMTIM
Register Bit CKI Frequency Range
76543210
0 0 0 0 0 0 0 1 25 kHz–33.3 kHz
0 0 0 0 0 0 1 0 37.5 kHz–50 kHz
0 0 0 0 0 0 1 1 50 kHz–66.67 kHz
0 0 0 0 0 1 0 0 62.5 kHz–83.3 kHz
0 0 0 0 0 1 0 1 75 kHz–100 kHz
0 0 0 0 0 1 1 1 100 kHz–133 kHz
0 0 0 0 1 0 0 0 112.5 kHz–150 kHz
0 0 0 0 1 0 1 1 150 kHz–200 kHz
0 0 0 0 1 1 1 1 200 kHz–266.67 kHz
0 0 0 1 0 0 0 1 225 kHz–300 kHz
0 0 0 1 0 1 1 1 300 kHz–400 kHz
0 0 0 1 1 1 0 1 375 kHz–500 kHz
0 0 1 0 0 1 1 1 500 kHz–666.67 kHz
0 0 1 0 1 1 1 1 600 kHz–800 kHz
0 0 1 1 1 1 1 1 800 kHz–1.067 MHz
0 1 0 0 0 1 1 1 1 MHz–1.33 MHz
0 1 0 0 1 0 0 0 1.125 MHz–1.5 MHz
0 1 0 0 1 0 1 1 1.5 MHz–2 MHz
36 Functional Description Copyright © 2000–2013, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
www.ti.com
SNOS535I OCTOBER 2000REVISED MARCH 2013
Table 5-7. PGMTIM Register Format (continued)
PGMTIM
Register Bit CKI Frequency Range
76543210
0 1 0 0 1 1 1 1 2 MHz–2.67 MHz
0 1 0 1 0 1 0 0 2.625 MHz–3.5 MHz
0 1 0 1 1 0 1 1 3.5 MHz–4.67 MHz
0 1 1 0 0 0 1 1 4.5 MHz–6 MHz
0 1 1 0 1 1 1 1 6 MHz–8 MHz
0 1 1 1 1 0 1 1 7.5 MHz–10 MHz
R R/W R/W R/W R/W R/W R/W R/W
5.10.4 MANEUVERING BACK AND FORTH BETWEEN FLASH MEMORY AND BOOT ROM
When using ISP, at some point, it will be necessary to maneuver between the flash program memory and
the Boot ROM, even when using customized ISP routines. This is because it's not possible to execute
from the flash program memory while it's being programmed.
Two instructions are available to perform the jumping back and forth: Jump to Boot (JSRB) and Return to
Flash (RETF). The JSRB instruction is used to jump from flash memory to Boot ROM, and the RETF is
used to return from the Boot ROM back to the flash program memory. See Instruction Set for specific
details on the operation of these instructions.
The JSRB instruction must be used in conjunction with the Key register. This is to prevent jumping to the
Boot ROM in the event of run-away software. For the JSRB instruction to actually jump to the Boot ROM,
the Key bit must be set. This is done by writing the value shown in Table 5-8 to the Key register. The Key
is a 6 bit key and if the key matches, the KEY bit will be set for 8 instruction cycles. The JSRB instruction
must be executed while the KEY bit is set. If the KEY does not match, then the KEY bit will not be set and
the JSRB will jump to the specified location in the flash memory. In emulation mode, if a breakpoint is
encountered while the KEY is set, the counter that counts the instruction cycles will be frozen until the
breakpoint condition is cleared. If an interrupt occurs while the key is set, the key will expire before
interrupt service is complete. It is recommended that the software globally disable interrupts before setting
the key. The Key register is a memory mapped register. Its format when writing is shown in Table 5-8. In
normal operation, it is not necessary to test the KEY bit before using the JSRB instruction. The additional
instructions required to test the key may cause the key to time-out before the JSRB can be executed.
Table 5-8. KEY Register Write Format
KEY When Writing
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
1 0 0 1 1 0 X X
Bits 7–2: Key value that must be written to set the KEY bit.
Bits 1–0: Don't care.
5.10.5 FORCED EXECUTION FROM BOOT ROM
When the user is developing a customized ISP routine, code lockups due to software errors may be
encountered. The normal, and preferred, method to recover from these conditions is to reprogram the
device with the corrected code by either an external parallel programmer or the emulation tools. As a last
resort, when this equipment is not available, there is a hardware method to get out of these lockups and
force execution from the Boot ROM MICROWIRE/PLUS routine. The customer will then be able to erase
the Flash Memory code and start over.
Copyright © 2000–2013, Texas Instruments Incorporated Functional Description 37
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
SNOS535I OCTOBER 2000REVISED MARCH 2013
www.ti.com
The method to force this condition is to drive the G6 pin to high voltage (2 x VCC) and activate Reset. The
high voltage condition on G6 must not be applied before VCC is valid and stable, and must be held for at
least 3 instruction cycles longer than Reset is active. This special condition will bypass checking the state
of the Flex bit in the Option Register and will start execution from location 0000 in the Boot ROM. In this
state, the user can input the appropriate commands, using MICROWIRE/PLUS, to erase the flash
program memory and reprogram it. If the device is subsequently reset before the Flex bit has been erased
by specific Page Erase or Mass Erase ISP commands, execution will start from location 0000 in the Flash
program memory. The high voltage (2 x VCC) on G6 will not erase either the Flex or the Security bit in the
Option Register. The Security bit, if set, can only be erased by a Mass Erase of the entire contents of the
Flash Memory unless under the control of User ISP routines in the Application Program.
While the G6 pin is at high voltage, the Load Clock will be output onto G5, which will look like an SK clock
to the MICROWIRE/PLUS routine executing in slave mode. However, when G6 is at high voltage, the G6
input will also look like a logic 1. The MICROWIRE/PLUS routine in Boot ROM monitors the G6 input,
waits for it to go low, debounces it, and then enables the ISP routine. CAUTION: The Load clock on G5
could be in conflict with the user's external SK. It is up to the user to resolve this conflict, as this condition
is considered a minor issue that's only encountered during software development. The user should also
be cautious of the high voltage applied to the G6 pin. This high voltage could damage other
circuitry connected to the G6 pin (e.g. the parallel port of a PC). The user may wish to disconnect
other circuitry while G6 is connected to the high voltage.
VCC must be valid and stable before high voltage is applied to G6.
The correct sequence to be used to force execution from Boot ROM is :
1. Disconnect G6 from the source of data for MICROWIRE/PLUS ISP.
2. Apply VCC to the device.
3. Pull RESET Low.
4. After VCC is valid and stable, connect a voltage between 2 x VCC and VCC+7V to the G6 pin. Ensure
that the rise time of the high voltage on G6 is slower than the minimum in the Electrical Specifications.
Figure 5-8 shows a possible circuit dliagram for implementing the 2 x VCC. Be aware of the typical input
current on the G6 pin when the high voltage is applied. The resistor used in the RC network, and the
high voltage used, should be chosen to keep the high voltage at the G6 pin between 2 x VCC and
VCC+7V.
5. Pull RESET High.
6. After a delay of at least three instruction cycles, remove the high voltage from G6.
Figure 5-8. Circuit Diagram for Implementing the 2 x VCC
5.10.6 RETURN TO FLASH MEMORY WITHOUT HARDWARE RESET
After programming the entire program memory, including options, it is necessary to exit the Boot ROM and
return to the flash program memory for program execution. Upon receipt and completion of the EXIT
command through the MICROWIRE/PLUS ISP, the ISP code will reset the part and begin execution from
the flash program memory as described in the Reset section. This assumes that the FLEX bit in the
Option register was programmed to 1.
38 Functional Description Copyright © 2000–2013, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
www.ti.com
SNOS535I OCTOBER 2000REVISED MARCH 2013
5.10.7 MICROWIRE/PLUS ISP
TI Semiconductor provides a program, which is available from our web site at www.ti.com, that is capable
of programming a device from the parallel port of a PC. The software accepts manually input commands
and is capable of downloading standard Intel HEX Format files.
Users who wish to write their own MICROWIRE/PLUS ISP host software should refer to the COP8 FLASH
ISP User Manual, available from the same web site. This document includes details of command format
and delays necessary between command bytes.
The MICROWIRE/PLUS ISP supports the following features and commands:
Write a value to the ISP Write Timing Register. NOTE: This must be the first command after entering
MICROWIRE/PLUS ISP mode.
Erase the entire flash program memory (mass erase).
Erase a page at a specified address.
Read Option register.
Read a byte from a specified address.
Write a byte to a specified address.
Read multiple bytes starting at a specified address.
Write multiple bytes starting at a specified address.
Exit ISP and return execution to flash program memory.
The following table lists the MICROWIRE/PLUS ISP commands and provides information on required
parameters and return values.
Table 5-9. MICROWIRE/PLUS ISP Commands
Command
Command Function Parameters Return Data
Value (Hex)
PGMTIM_SET Write Pulse Timing 0x3B Value N/A
Register
PAGE_ERASE Page Erase 0xB3 Starting Address of Page N/A
MASS_ERASE Mass Erase 0xBF Confirmation Code N/A (The entire Flash
Memory will be erased)
READ_BYTE Read Byte 0x1D Address High, Address Data Byte if Security not
Low set. 0xFF if Security set.
Option Register if address
= 0xFFFF, regardless of
Security
BLOCKR Block Read 0xA3 Address High, Address n Data Bytes if Security
Low, Byte Count (n) High, not set.
Byte Count (n) Low n Bytes of 0xFF if Security
0n32767 set.
WRITE_BYTE Write Byte 0x71 Address High, Address N/A
Low, Data Byte
BLOCKW Block Write 0x8F Address High, Address N/A
Low, Byte Count (0 n
16), n Data Bytes
EXIT EXIT 0xD3 N/A N/A (Device will Reset)
INVALID N/A Any other invalid N/A
command will be ignored
5.10.8 USER ISP AND VIRTUAL E2
The following commands will support transferring blocks of data from RAM to flash program memory, and
vice-versa. The user is expected to enforce application security in this case.
Erase the entire flash program memory (mass erase). NOTE: Execution of this command will force the
device into the MICROWIRE/PLUS ISP mode.
Copyright © 2000–2013, Texas Instruments Incorporated Functional Description 39
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
SNOS535I OCTOBER 2000REVISED MARCH 2013
www.ti.com
Erase a page of flash memory at a specified address.
Read a byte from a specified address.
Write a byte to a specified address.
Copy a block of data from RAM into flash program memory.
Copy a block of data from program flash memory to RAM.
The following table lists the User ISP/Virtual E2commands, required parameters and return data, if
applicable. The command entry point is used as an argument to the JSRB instruction. Table 5-11 lists the
Ram locations and Peripheral Registers, used for User ISP and Virtual E2, and their expected contents.
Please refer to the COP8 FLASH ISP User Manual for additional information and programming examples
on the use of User ISP and Virtual E2.
Table 5-10. User ISP/Virtual E2Entry Points
Command/ Command
Function Parameters Return Data
Label Entry Point
cpgerase Page Erase 0x17 Register ISPADHI is loaded by the user with N/A (A page of memory beginning at
the high byte of the address. ISPADHI, ISPADLO will be erased)
Register ISPADLO is loaded by the user
with the low byte of the address.
cmserase Mass Erase 0x1A Accumulator A contains the confirmation N/A (The entire Flash Memory will be
key 0x55. erased)
creadbf Read Byte 0x11 Register ISPADHI is loaded by the user with Data Byte in Register ISPRD.
the high byte of the address.
Register ISPADLO is loaded by the user
with the low byte of the address.
cblockr Block Read 0x26 Register ISPADHI is loaded by the user with n Data Bytes, Data will be returned
the high byte of the address. beginning at a location pointed to by the
Register ISPADLO is loaded by the user RAM address in X.
with the low byte of the address.
X pointer contains the beginning RAM
address where the result(s) will be returned.
Register BYTECOUNTLO contains the
number of n bytes to read (0 n255). It is
up to the user to setup the segment register.
cwritebf Write Byte 0x14 Register ISPADHI is loaded by the user with N/A
the high byte of the address.
Register ISPADLO is loaded by the user
with the low byte of the address.
Register ISPWR contains the Data Byte to
be written.
cblockw Block Write 0x23 Register ISPADHI is loaded by the user with N/A
the high byte of the address.
Register ISPADLO is loaded by the user
with the low byte of the address.
Register BYTECOUNTLO contains the
number of n bytes to write (0 n16).
The combination of the BYTECOUNTLO
and the ISPADLO registers must be set
such that the operation will not cross a 64
byte boundary.
X pointer contains the beginning RAM
address of the data to be written.
It is up to the user to setup the segment
register.
exit EXIT 0x62 N/A N/A (Device will Reset)
uwisp MICROWIRE/ 0x00 N/A N/A (Device will be in MICROWIRE/PLUS
PLUS ISP Mode. Must be terminated by
ISP Start MICROWIRE/PLUS ISP EXIT command
which will Reset the device)
40 Functional Description Copyright © 2000–2013, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
www.ti.com
SNOS535I OCTOBER 2000REVISED MARCH 2013
Table 5-11. Register and Bit Name Definitions
Register RAM
Purpose
Name Location
ISPADHI High byte of Flash Memory Address 0xA9
ISPADLO Low byte of Flash Memory Address 0xA8
ISPWR The user must store the byte to be written into this register before jumping into the write byte 0xAB
routine.
ISPRD Data will be returned to this register after the read byte routine execution. 0xAA
ISPKEY The ISPKEY Register is required to validate the JSRB instruction and must be loaded within 6 0xE2
instruction cycles before the JSRB.
BYTECOUNTLO Holds the count of the number of bytes to be read or written in block operations. 0xF1
PGMTIM Write Timing Register. This register must be loaded, by the user, with the proper value before 0xE1
execution of any USER ISP Write or Erase operation. Refer to Table 5-7 for the correct value.
Confirmation Code The user must place this code in the accumulator before execution of a Flash Memory Mass Erase A
command.
KEY Must be transferred to the ISPKEY register before execution of a JSRB instruction. 0x98
5.10.9 RESTRICTIONS ON SOFTWARE WHEN CALLING ISP ROUTINES IN BOOT ROM
1. The hardware will disable interrupts from occurring. The hardware will leave the GIE bit in its current
state, and if set, the hardware interrupts will occur when execution is returned to Flash Memory.
Subsequent interrupts, during ISP operation, from the same interrupt source will be lost. Interrupts
may occur between setting the KEY and executing the JSRB instruction. In this case, the KEY
will expire before the JSRB is executed. It is, therefore, recommended that the software globally
disable interrupts before setting the Key.
2. The security feature in the MICROWIRE/PLUS ISP is ensured by software and not hardware. When
executing the MICROWIRE/PLUS ISP routine, the security bit is checked prior to performing all
instructions. Only the mass erase command, write PGMTIM register, and reading the Option register is
permitted within the MICROWIRE/PLUS ISP routine. When the user is performing his own ISP, all
commands are permitted. The entry points from the user's ISP code do not check for security. It is the
burden of the user to ensure his own security. See the Security bit description in Option Register for
more details on security.
3. When using any of the ISP functions in Boot ROM, the ISP routines will service the WATCHDOG
within the selected upper window. Upon return to flash memory, the WATCHDOG is serviced, the
lower window is enabled, and the user can service the WATCHDOG anytime following exit from Boot
ROM, but must service it within the selected upper window to avoid a WATCHDOG error.
4. Block Writes can start anywhere in the page of Flash memory, but cannot cross half page or full page
boundaries.
5. The user must ensure that a page erase or a mass erase is executed between two consecutive
writes to the same location in Flash memory. Two writes to the same location without an
intervening erase will produce unpredicatable results including possible disturbance of
unassociated locations.
5.10.10 FLASH MEMORY DURABILITY CONSIDERATIONS
The endurance of the Flash Memory (number of possible Erase/Write cycles) is a function of the erase
time and the lowest temperature at which the erasure occurs. If the device is to be used at low
temperature, additional erase operations can be used to extend the erase time. The user can determine
how many times to erase a page based on what endurance is desired for the application (e.g. four page
erase cycles, each time a page erase is done, may be required to achieve the typical 100k Erase/Write
cycles in an application which may be operating down to 0°C). Also, the customer can verify that the entire
page is erased, with software, and request additional erase operations if desired.
Copyright © 2000–2013, Texas Instruments Incorporated Functional Description 41
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
SNOS535I OCTOBER 2000REVISED MARCH 2013
www.ti.com
Table 5-12. Typical Flash Memory Endurance
Low End of Operating Temp Range
Erase Time 40°C 20°C 0°C 25°C >25°C
1 ms 60k 60k 60k 100k 100k
2 ms 60k 60k 60k 100k 100k
3 ms 60k 60k 60k 100k 100k
4 ms 60k 60k 100k 100k 100k
5 ms 70k 70k 100k 100k 100k
6 ms 80k 80k 100k 100k 100k
7 ms 90k 90k 100k 100k 100k
8 ms 100k 100k 100k 100k 100k
5.11 Timers
The device contains a very versatile set of timers (T0, T1, T2 and T3). Timers T1, T2 and T3 and
associated autoreload/capture registers power up containing random data.
5.11.1 TIMER T0 (IDLE TIMER)
The device supports applications that require maintaining real time and low power with the IDLE mode.
This IDLE mode support is furnished by the IDLE Timer T0, which is a 16-bit timer. The user cannot read
or write to the IDLE Timer T0, which is a count down timer.
As described in Power Saving Features, the clock to the IDLE Timer depends on which mode the device
is in. If the device is in High Speed mode, the clock to the IDLE Timer is the instruction cycle clock (one-
fifth of the CKI frequency). If the device is in Dual Clock mode or Low Speed mode, the clock to the IDLE
Timer is the 32 kHz clock. For the remainder of this section, the term “selected clock” will refer to the clock
selected by the Power Save mode of the device. During Dual Clock and Low Speed modes, the divide by
10 that creates the instruction cycle clock is disabled, to minimize power consumption.
In addition to its time base function, the Timer T0 supports the following functions:
Exit out of the Idle Mode (See Idle Mode description)
WATCHDOG logic (See WATCHDOG description)
Start up delay out of the HALT mode
Start up delay from BOR
Figure 5-9 is a functional block diagram showing the structure of the IDLE Timer and its associated
interrupt logic.
Bits 11 through 15 of the ITMR register can be selected for triggering the IDLE Timer interrupt. Each time
the selected bit underflows (every 4k, 8k, 16k, 32k or 64k selected clocks), the IDLE Timer interrupt
pending bit T0PND is set, thus generating an interrupt (if enabled), and bit 6 of the Port G data register is
reset, thus causing an exit from the IDLE mode if the device is in that mode.
In order for an interrupt to be generated, the IDLE Timer interrupt enable bit T0EN must be set, and the
GIE (Global Interrupt Enable) bit must also be set. The T0PND flag and T0EN bit are bits 5 and 4 of the
ICNTRL register, respectively. The interrupt can be used for any purpose. Typically, it is used to perform a
task upon exit from the IDLE mode. For more information on the IDLE mode, refer to Power Saving
Features.
The Idle Timer period is selected by bits 0–2 of the ITMR register Bit 3 of the ITMR Register is reserved
and should not be used as a software flag. Bits 4 through 7 of the ITMR Register are used by the dual
clock and are described in Power Saving Features.
42 Functional Description Copyright © 2000–2013, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
www.ti.com
SNOS535I OCTOBER 2000REVISED MARCH 2013
Figure 5-9. Functional Block Diagram for Idle Timer T0
Table 5-13. Idle Timer Window Length
Idle Timer Period
ITSEL2 ITSEL1 ITSEL0 High Speed Dual Clock or
Mode Low Speed Mode
0 0 0 4,096 inst. cycles 0.125 seconds
0 0 1 8,192 inst. cycles 0.25 seconds
0 1 0 16,384 inst. cycles 0.5 seconds
0 1 1 32,768 inst. cycles 1 second
1 0 0 65,536 inst. cycles 2 seconds
1 0 1 Reserved - Undefined
1 1 0 Reserved - Undefined
1 1 1 Reserved - Undefined
The ITSEL bits of the ITMR register are cleared on Reset and the Idle Timer period is reset to 4,096
instruction cycles.
5.11.1.1 ITMR Register
CCK
LSON HSON DCEN RSVD ITSEL2 ITSEL1 ITSEL0
SEL
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Bits 7–4: Described in Power Saving Features.
NOTE
Documentation for previous COP8 devices, which included the Programmable Idle Timer,
recommended the user write zero to the high order bits of the ITMR Register. If existing
programs are updated to use this device, writing zero to these bits will cause the device to
reset (see Power Saving Features).
RSVD: This bit is reserved and must be set to 0.
ITSEL2:0: Selects the Idle Timer period as described in Table 5-13, Idle Timer Window Length.
Copyright © 2000–2013, Texas Instruments Incorporated Functional Description 43
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
SNOS535I OCTOBER 2000REVISED MARCH 2013
www.ti.com
Any time the IDLE Timer period is changed there is the possibility of generating a spurious IDLE Timer
interrupt by setting the T0PND bit. The user is advised to disable IDLE Timer interrupts prior to changing
the value of the ITSEL bits of the ITMR Register and then clear the T0PND bit before attempting to
synchronize operation to the IDLE Timer.
5.11.2 TIMER T1, TIMER T2, AND TIMER T3
The device has a set of three powerful timer/counter blocks, T1, T2, and T3. Since T1, T2 and T3 are
identical, except for the high speed operation of T2 and T3, all comments are equally applicable to any of
the three timer blocks which will be referred to as Tx. Differences between the timers will be specifically
noted.
Each timer block consists of a 16-bit timer, Tx, and two supporting 16-bit autoreload/capture registers,
RxA and RxB. Each timer block has two pins associated with it, TxA and TxB. The pin TxA supports I/O
required by the timer block, while the pin TxB is an input to the timer block. The timer block has three
operating modes: Processor Independent PWM mode, External Event Counter mode, and Input Capture
mode.
The control bits TxC3, TxC2, and TxC1 allow selection of the different modes of operation.
5.11.2.1 Timer Operating Speeds
Each of the Tx timers, except T1, have the ability to operate at either the instruction cycle frequency (low
speed) or the internal clock frequency (MCLK). For 10 MHz CKI, the instruction cycle frequency is 2 MHz
and the internal clock frequency is 20 MHz. This feature is controlled by the High Speed Timer Control
Register, HSTCR. Its format is shown below. To place a timer, Tx, in high speed mode, set the
appropriate TxHS bit to 1. For low speed operation, clear the appropriate TxHS bit to 0. This register is
cleared to 00 on Reset.
HSTCR
Bit Bit
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 1 0
0 0 0 0 0 0 T3HS T2HS
5.11.2.2 Mode 1. Processor Independent PWM Mode
One of the timer's operating modes is the Processor Independent PWM mode. In this mode, the timers
generate a “Processor Independent” PWM signal because once the timer is set up, no more action is
required from the CPU which translates to less software overhead and greater throughput. The user
software services the timer block only when the PWM parameters require updating. This capability is
provided by the fact that the timer has two separate 16-bit reload registers. One of the reload registers
contains the “ON” time while the other holds the “OFF” time. By contrast, a microcontroller that has only a
single reload register requires an additional software to update the reload value (alternate between the on-
time/off-time).
The timer can generate the PWM output with the width and duty cycle controlled by the values stored in
the reload registers. The reload registers control the countdown values and the reload values are
automatically written into the timer when it counts down through 0, generating interrupt on each reload.
Under software control and with minimal overhead, the PWM outputs are useful in controlling motors,
triacs, the intensity of displays, and in providing inputs for data acquisition and sine wave generators.
In this mode, the timer Tx counts down at a fixed rate of tC(T2 and T3 may be selected to operate from
MCLK). Upon every underflow the timer is alternately reloaded with the contents of supporting registers,
RxA and RxB. The very first underflow of the timer causes the timer to reload from the register RxA.
Subsequent underflows cause the timer to be reloaded from the registers alternately beginning with the
register RxB.
Figure 5-10 shows a block diagram of the timer in PWM mode.
44 Functional Description Copyright © 2000–2013, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
www.ti.com
SNOS535I OCTOBER 2000REVISED MARCH 2013
The underflows can be programmed to toggle the TxA output pin. The underflows can also be
programmed to generate interrupts.
Underflows from the timer are alternately latched into two pending flags, TxPNDA and TxPNDB. The user
must reset these pending flags under software control. Two control enable flags, TxENA and TxENB,
allow the interrupts from the timer underflow to be enabled or disabled. Setting the timer enable flag
TxENA will cause an interrupt when a timer underflow causes the RxA register to be reloaded into the
timer. Setting the timer enable flag TxENB will cause an interrupt when a timer underflow causes the RxB
register to be reloaded into the timer. Resetting the timer enable flags will disable the associated
interrupts.
Either or both of the timer underflow interrupts may be enabled. This gives the user the flexibility of
interrupting once per PWM period on either the rising or falling edge of the PWM output. Alternatively, the
user may choose to interrupt on both edges of the PWM output.
Figure 5-10. Timer in PWM Mode
5.11.2.3 Mode 2. External Event Counter Mode
This mode is quite similar to the processor independent PWM mode described above. The main difference
is that the timer, Tx, is clocked by the input signal from the TxA pin after synchronization to the
appropriate internal clock (tCor MCLK). The Tx timer control bits, TxC3, TxC2 and TxC1 allow the timer to
be clocked either on a positive or negative edge from the TxA pin. Underflows from the timer are latched
into the TxPNDA pending flag. Setting the TxENA control flag will cause an interrupt when the timer
underflows.
In this mode the input pin TxB can be used as an independent positive edge sensitive interrupt input if the
TxENB control flag is set. The occurrence of a positive edge on the TxB input pin is latched into the
TxPNDB flag.
Figure 5-11 shows a block diagram of the timer in External Event Counter mode.
NOTE
The PWM output is not available in this mode since the TxA pin is being used as the counter
input clock.
Copyright © 2000–2013, Texas Instruments Incorporated Functional Description 45
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
SNOS535I OCTOBER 2000REVISED MARCH 2013
www.ti.com
Figure 5-11. Timer in External Event Counter Mode
5.11.2.4 Mode 3. Input Capture Mode
The device can precisely measure external frequencies or time external events by placing the timer block,
Tx, in the input capture mode. In this mode, the reload registers serve as independent capture registers,
capturing the contents of the timer when an external event occurs (transition on the timer input pin). The
capture registers can be read while maintaining count, a feature that lets the user measure elapsed time
and time between events. By saving the timer value when the external event occurs, the time of the
external event is recorded. Most microcontrollers have a latency time because they cannot determine the
timer value when the external event occurs. The capture register eliminates the latency time, thereby
allowing the applications program to retrieve the timer value stored in the capture register.
In this mode, the timer Tx is constantly running at the fixed tCor MCLK rate. The two registers, RxA and
RxB, act as capture registers. Each register also acts in conjunction with a pin. The register RxA acts in
conjunction with the TxA pin and the register RxB acts in conjunction with the TxB pin.
The timer value gets copied over into the register when a trigger event occurs on its corresponding pin
after synchronization to the appropriate internal clock (tCor MCLK). Control bits, TxC3, TxC2 and TxC1,
allow the trigger events to be specified either as a positive or a negative edge. The trigger condition for
each input pin can be specified independently.
The trigger conditions can also be programmed to generate interrupts. The occurrence of the specified
trigger condition on the TxA and TxB pins will be respectively latched into the pending flags, TxPNDA and
TxPNDB. The control flag TxENA allows the interrupt on TxA to be either enabled or disabled. Setting the
TxENA flag enables interrupts to be generated when the selected trigger condition occurs on the TxA pin.
Similarly, the flag TxENB controls the interrupts from the TxB pin.
Underflows from the timer can also be programmed to generate interrupts. Underflows are latched into the
timer TxC0 pending flag (the TxC0 control bit serves as the timer underflow interrupt pending flag in the
Input Capture mode). Consequently, the TxC0 control bit should be reset when entering the Input Capture
mode. The timer underflow interrupt is enabled with the TxENA control flag. When a TxA interrupt occurs
in the Input Capture mode, the user must check both the TxPNDA and TxC0 pending flags in order to
determine whether a TxA input capture or a timer underflow (or both) caused the interrupt.
Figure 5-12 shows a block diagram of the timer T1 in Input Capture mode. T2 and T3 are identical to T1.
46 Functional Description Copyright © 2000–2013, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
www.ti.com
SNOS535I OCTOBER 2000REVISED MARCH 2013
Figure 5-12. Timer in Input Capture Mode
5.11.3 TIMER CONTROL FLAGS
The control bits and their functions are summarized below.
TxC3 Timer mode control
TxC2 Timer mode control
TxC1 Timer mode control
TxC0 Timer Start/Stop control in Modes 1 and 2 (Processor Independent PWM and External Event
Counter), where 1 = Start, 0 = Stop
Timer Underflow Interrupt Pending Flag in Mode 3 (Input Capture)
TxPNDA Timer Interrupt Pending Flag
TxENA Timer Interrupt Enable Flag
1 = Timer Interrupt Enabled
0 = Timer Interrupt Disabled
TxPNDB Timer Interrupt Pending Flag
TxENB Timer Interrupt Enable Flag
1 = Timer Interrupt Enabled
0 = Timer Interrupt Disabled
The timer mode control bits (TxC3, TxC2 and TxC1) are detailed in Table 5-14, Timer Operating Modes.
When the high speed timers are counting in high speed mode, directly altering the contents of the timer
upper or lower registers, the PWM outputs or the reload registers is not recommended. Bit operations can
be particularly problematic. Since any of these six registers or the PWM outputs can change as many as
ten times in a single instruction cycle, performing an SBIT or RBIT operation with the timer running can
produce unpredictable results. The recommended procedure is to stop the timer, perform any changes to
the timer, the PWM outputs or reload register values, and then re-start the timer. This warning does not
apply to the timer control register. Any type of read/write operation, including SBIT and RBIT may be
performed on this register in any operating mode.
Copyright © 2000–2013, Texas Instruments Incorporated Functional Description 47
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
SNOS535I OCTOBER 2000REVISED MARCH 2013
www.ti.com
Table 5-14. Timer Operating Modes
Interrupt A Source Interrupt B Source Timer Counts
Mode TxC3 TxC2 TxC1 Description On
1 0 1 PWM: TxA Toggle Autoreload RA Autoreload RB tCor MCLK
11 0 0 PWM: No TxA Toggle Autoreload RA Autoreload RB tCor MCLK
0 0 0 External Event Counter Timer Underflow Pos. TxB Edge TxA Pos. Edge
20 0 1 External Event Counter Timer Underflow Pos. TxB Edge TxA Neg. Edge
0 1 0 Captures: Pos. TxA Edge Pos. TxB Edge tCor MCLK
TxA Pos. Edge or Timer
TxB Pos. Edge Underflow
1 1 0 Captures: Pos. TxA Neg. TxB tCor MCLK
TxA Pos. Edge Edge or Timer Edge
TxB Neg. Edge Underflow
30 1 1 Captures: Neg. TxA Pos. TxB tCor MCLK
TxA Neg. Edge Edge or Timer Edge
TxB Pos. Edge Underflow
1 1 1 Captures: Neg. TxA Neg. TxB tCor MCLK
TxA Neg. Edge Edge or Timer Edge
TxB Neg. Edge Underflow
5.12 Power Saving Features
Today, the proliferation of battery-operated applications has placed new demands on designers to drive
power consumption down. Battery operated systems are not the only type of applications demanding low
power. The power budget constraints are also imposed on those consumer/industrial applications where
well regulated and expensive power supply costs cannot be tolerated. Such applications rely on low cost
and low power supply voltage derived directly from the “mains” by using voltage rectifier and passive
components. Low power is demanded even in automotive applications, due to increased vehicle
electronics content. This is required to ease the burden from the car battery. Low power 8-bit
microcontrollers supply the smarts to control battery-operated, consumer/industrial, and automotive
applications.
The device offers system designers a variety of low-power consumption features that enable them to meet
the demanding requirements of today's increasing range of low-power applications. These features include
low voltage operation, low current drain, and power saving features such as HALT, IDLE, and Multi-Input
Wake-Up (MIWU).
This device supports three operating modes, each of which have two power save modes of operation. The
three operating modes are: High Speed, Dual Clock, and Low Speed. Within each operating mode, the
two power save modes are: HALT and IDLE. In the HALT mode of operation, all microcontroller activities
are stopped and power consumption is reduced to a very low level. In this device, the HALT mode is
enabled and disabled by a bit in the Option register. The IDLE mode is similar to the HALT mode, except
that certain sections of the device continue to operate, such as: the on-board oscillator, the IDLE Timer
(Timer T0), and the Clock Monitor. This allows real time to be maintained. During power save modes of
operation, all on board RAM, registers, I/O states and timers (with the exception of T0) are unaltered.
Two oscillators are used to support the three different operating modes. The high speed oscillator refers to
the oscillator connected to CKI and the low speed oscillator refers to the 32 kHz oscillator connected to
pins L0 & L1. When using L0 and L1 for the low speed oscillator, the user must ensure that the L0 and L1
pins are configured for hi-Z input, L1 is not using CKX on the USART, and Multi-Input Wake-up for these
pins is disabled.
A diagram of the three modes is shown in Figure 5-13.
48 Functional Description Copyright © 2000–2013, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
www.ti.com
SNOS535I OCTOBER 2000REVISED MARCH 2013
Figure 5-13. Diagram of Power Save Modes
5.12.1 POWER SAVE MODE CONTROL REGISTER
The ITMR control register allows for navigation between the three different modes of operation. It is also
used for the Idle Timer. The register bit assignments are shown below. This register is cleared to 40 (hex)
by Reset as shown below.
LSON HSON DCEN CCK RSVD ITSEL2 ITSEL1 ITSEL0
SEL
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
LSON: This bit is used to turn-on the low-speed oscillator. When LSON = 0, the low speed oscillator
is off. When LSON = 1, the low speed oscillator is on. There is a startup time associated with
this oscillator. See the Control Registers section.
HSON: This bit is used to turn-on the high speed oscillator. When HSON = 0, the high speed
oscillator is off. When HSON = 1, the high speed oscillator is on. There is a startup time
associated with this oscillator. See the startup time table in the Control Registers section.
DCEN: This bit selects the clock source for the Idle Timer. If this bit = 0, then the high speed clock is
the clock source for the Idle Timer. If this bit = 1, then the low speed clock is the clock
source for the Idle Timer. The low speed oscillator must be started and stabilized before
setting this bit to a 1.
CCKSEL: This bit selects whether the high speed clock or low speed clock is gated to the
microcontroller core. When this bit = 0, the Core clock will be the high speed clock. When
this bit = 1, then the Core clock will be the low speed clock. Before switching this bit to either
state, the appropriate clock should be turned on and stabilized.
DCEN CCKSEL
0 0 High Speed Mode. Core and Idle Timer Clock = High Speed
1 0 Dual Clock Mode. Core clock = High Speed; Idle Timer = Low Speed
1 1 Low Speed Mode. Core and Idle Timer Clock = Low Speed
0 1 Invalid. If this is detected, the Low Speed Mode will be forced.
RSVD: This bit is reserved and must be 0.
Bits 2–0: These are bits used to control the Idle Timer. See TIMER T0 (IDLE TIMER) for the
Copyright © 2000–2013, Texas Instruments Incorporated Functional Description 49
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
SNOS535I OCTOBER 2000REVISED MARCH 2013
www.ti.com
description of these bits.
Table 5-15 lists the valid contents of the four most significant bits of the ITMR Register. Any other value is
illegal. States are presented in the only valid sequence. Any attempt to make a transition to any state
other than an adjacent valid state will be ignored by the logic and the ITMR Register will not be changed.
Table 5-15. Valid Contents of Dual Clock Control Bits
LSON HSON DCEN CCKSEL Mode
0 1 0 0 High Speed
1 1 0 0 High Speed/Dual Clock Transition
1 1 1 0 Dual Clock
1 1 1 1 Dual Clock/Low Speed Transition
1 0 1 1 Low Speed
5.12.2 OSCILLATOR STABILIZATION
Both the high speed oscillator and low speed oscillator have a startup delay associated with them. When
switching between the modes, the software must ensure that the appropriate oscillator is started up and
stabilized before switching to the new mode. See Table 5-2, Startup Times for approximate startup times
for both oscillators.
5.12.3 HIGH SPEED MODE OPERATION
This mode of operation allows high speed operation for both the main Core clock and also for the Idle
Timer. This is the default mode of the device and will always be entered upon any of the Reset conditions
described in the Reset section. It can also be entered from Dual Clock mode. It cannot be directly entered
from the Low Speed mode without passing through the Dual Clock mode first.
To enter from the Dual Clock mode, the following sequence must be followed using two separate
instructions:
1. Software clears DCEN to 0.
2. Software clears LSON to 0.
5.12.3.1 High Speed Halt Mode
The fully static architecture of this device allows the state of the microcontroller to be frozen. This is
accomplished by stopping the internal clock of the device during the HALT mode. The controller also stops
the CKI pin from oscillating during the HALT mode. The processor can be forced to exit the HALT mode
and resume normal operation at any time.
During normal operation, the actual power consumption depends heavily on the clock speed and operating
voltage used in an application and is shown in the Electrical Specifications. In the HALT mode, the device
only draws a small leakage current, plus current for the BOR feature (if enabled), plus any current
necessary for driving the outputs. Since total power consumption is affected by the amount of current
required to drive the outputs, all I/Os should be configured to draw minimal current prior to entering the
HALT mode, if possible. In order to reduce power consumption even further, the power supply (VCC) can
be reduced to a very low level during the HALT mode, just high enough to ensure retention of data stored
in RAM. The allowed lower voltage level (VR) is specified in the Electrical Specs section.
5.12.3.1.1 Entering The High Speed Halt Mode
The device enters the HALT mode under software control when the Port G data register bit 7 is set to 1.
All processor action stops in the middle of the next instruction cycle, and power consumption is reduced to
a very low level.
50 Functional Description Copyright © 2000–2013, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
www.ti.com
SNOS535I OCTOBER 2000REVISED MARCH 2013
5.12.3.1.2 Exiting The High Speed Halt Mode
There is a choice of methods for exiting the HALT mode: a chip Reset using the RESET pin or a Multi-
Input Wake-up.
5.12.3.1.3 HALT Exit Using Reset
A device Reset, which is invoked by a low-level signal on the RESET input pin, takes the device out of the
HALT mode and starts execution from address 0000H. The initialization software should determine what
special action is needed, if any, upon start-up of the device from HALT. The initialization of all registers
following a RESET exit from HALT is described in the Reset section of this manual.
5.12.3.1.4 HALT Exit Using Multi-Input Wake-up
The device can be brought out of the HALT mode by a transition received on one of the available Wake-
up pins. The pins used and the types of transitions sensed on the Multi-input pins are software
programmable. For information on programming and using the Multi-Input Wake-up feature, refer to the
Multi-Input Wake-up section.
A start-up delay is required between the device wake-up and the execution of program instructions,
depending on the type of chip clock. The start-up delay is mandatory, and is implemented whether or not
the CLKDLY bit is set. This is because all crystal oscillators and resonators require some time to reach a
stable frequency and full operating amplitude.
The IDLE Timer (Timer T0) provides a fixed delay from the time the clock is enabled to the time the
program execution begins. Upon exit from the HALT mode, the IDLE Timer is enabled with a starting
value of 256 and is decremented with each instruction cycle. (The instruction clock runs at one-fifth the
frequency of the high speed oscillator.) An internal Schmitt trigger connected to the on-chip CKI inverter
ensures that the IDLE Timer is clocked only when the oscillator has a large enough amplitude. (The
Schmitt trigger is not part of the oscillator closed loop.) When the IDLE Timer underflows, the clock signals
are enabled on the chip, allowing program execution to proceed. Thus, the delay is equal to 256
instruction cycles.
NOTE
To ensure accurate operation upon start-up of the device using Multi-input Wake-up, the
instruction in the application program used for entering the HALT mode should be followed
by two consecutive NOP (no-operation) instructions.
5.12.3.1.5 Options
This device has two options associated with the HALT mode. The first option enables the HALT mode
feature, while the second option disables HALT mode operation. Selecting the disable HALT mode option
will cause the microcontroller to ignore any attempts to HALT the device under software control. Note that
this device can still be placed in the HALT mode by stopping the clock input to the microcontroller, if the
program memory is masked ROM. See the Option section for more details on this option bit.
Copyright © 2000–2013, Texas Instruments Incorporated Functional Description 51
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
SNOS535I OCTOBER 2000REVISED MARCH 2013
www.ti.com
Figure 5-14. Wake-up from HALT
5.12.3.2 High Speed Idle Mode
In the IDLE mode, program execution stops and power consumption is reduced to a very low level as with
the HALT mode. However, the high speed oscillator, IDLE Timer (Timer T0), and Clock Monitor continue
to operate, allowing real time to be maintained. The device remains idle for a selected amount of time up
to 65,536 instruction cycles, or 32.768 milliseconds with a 2 MHz instruction clock frequency, and then
automatically exits the IDLE mode and returns to normal program execution.
The device is placed in the IDLE mode under software control by setting the IDLE bit (bit 6 of the Port G
data register).
The IDLE Timer window is selectable from one of five values, 4k, 8k, 16k, 32k or 64k instruction cycles.
Selection of this value is made through the ITMR register.
The IDLE mode uses the on-chip IDLE Timer (Timer T0) to keep track of elapsed time in the IDLE state.
The IDLE Timer runs continuously at the instruction clock rate, whether or not the device is in the IDLE
mode. Each time the bit of the timer associated with the selected window toggles, the T0PND bit is set, an
interrupt is generated (if enabled), and the device exits the IDLE mode if in that mode. If the IDLE Timer
interrupt is enabled, the interrupt is serviced before execution of the main program resumes. (However,
the instruction which was started as the part entered the IDLE mode is completed before the interrupt is
serviced. This instruction should be a NOP which should follow the enter IDLE instruction.) The user must
reset the IDLE Timer pending flag (T0PND) before entering the IDLE mode.
As with the HALT mode, this device can also be returned to normal operation with a reset, or with a Multi-
Input Wake-up input. Upon reset the ITMR register is cleared and the ITMR register selects the 4,096
instruction cycle tap of the Idle Timer.
The IDLE Timer cannot be started or stopped under software control, and it is not memory mapped, so it
cannot be read or written by the software. Its state upon Reset is unknown. Therefore, if the device is put
into the IDLE mode at an arbitrary time, it will stay in the IDLE mode for somewhere between 1 and the
selected number of instruction cycles.
In order to precisely time the duration of the IDLE state, entry into the IDLE mode must be synchronized to
the state of the IDLE Timer. The best way to do this is to use the IDLE Timer interrupt, which occurs on
every underflow of the bit of the IDLE Timer which is associated with the selected window. Another
method is to poll the state of the IDLE Timer pending bit T0PND, which is set on the same occurrence.
The Idle Timer interrupt is enabled by setting bit T0EN in the ICNTRL register.
Any time the IDLE Timer window length is changed there is the possibility of generating a spurious IDLE
Timer interrupt by setting the T0PND bit. The user is advised to disable IDLE Timer interrupts prior to
changing the value of the ITSEL bits of the ITMR Register and then clear the TOPND bit before
attempting to synchronize operation to the IDLE Timer.
52 Functional Description Copyright © 2000–2013, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
www.ti.com
SNOS535I OCTOBER 2000REVISED MARCH 2013
NOTE
As with the HALT mode, it is necessary to program two NOP's to allow clock
resynchronization upon return from the IDLE mode. The NOP's are placed either at the
beginning of the IDLE Timer interrupt routine or immediately following the “enter IDLE mode”
instruction.
For more information on the IDLE Timer and its associated interrupt, see the description in the Timers
section.
5.12.4 DUAL CLOCK MODE OPERATION
This mode of operation allows for high speed operation of the Core clock and low speed operation of the
Idle Timer. This mode can be entered from either the High Speed mode or the Low Speed mode.
To enter from the High Speed mode, the following sequence must be followed:
1. Software sets the LSON bit to 1.
2. Software waits until the low speed oscillator has stabilized. See Table 5-2.
3. Software sets the DCEN bit to 1.
To enter from the Low Speed mode, the following sequence must be followed:
1. Software sets the HSON bit to 1.
2. Software waits until the high speed oscillator has stabilized. See Table 5-2, Startup Times.
3. Software clears the CCKSEL bit to 0.
5.12.4.1 Dual Clock HALT Mode
The fully static architecture of this device allows the state of the microcontroller to be frozen. This is
accomplished by stopping the high speed clock of the device during the HALT mode. The processor can
be forced to exit the HALT mode and resume normal operation at any time. The low speed clock remains
on during HALT in the Dual Clock mode.
During normal operation, the actual power consumption depends heavily on the clock speed and operating
voltage used in an application and is shown in the Electrical Specifications. In the HALT mode, the device
only draws a small leakage current, plus current for the BOR feature (if enabled), plus the 32 kHz
oscillator current, plus any current necessary for driving the outputs. Since total power consumption is
affected by the amount of current required to drive the outputs, all I/Os should be configured to draw
minimal current prior to entering the HALT mode, if possible.
5.12.4.1.1 Entering The Dual Clock Halt Mode
The device enters the HALT mode under software control when the Port G data register bit 7 is set to 1.
All processor action stops in the middle of the next instruction cycle, and power consumption is reduced to
a very low level. In order to expedite exit from HALT, the low speed oscillator is left running when the
device is Halted in the Dual Clock mode. However, the Idle Timer will not be clocked.
5.12.4.1.2 Exiting The Dual Clock Halt Mode
When the HALT mode is entered by setting bit 7 of the Port G data register, there is a choice of methods
for exiting the HALT mode: a chip Reset using the RESET pin or a Multi-Input Wake-up. The Reset
method and Multi-Input Wake-up method can be used with any clock option.
5.12.4.1.3 HALT Exit Using Reset
A device Reset, which is invoked by a low-level signal on the RESET input pin, takes the device out of the
Dual Clock mode and puts it into the High Speed mode.
Copyright © 2000–2013, Texas Instruments Incorporated Functional Description 53
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
SNOS535I OCTOBER 2000REVISED MARCH 2013
www.ti.com
5.12.4.1.4 HALT Exit Using Multi-Input Wake-up
The device can be brought out of the HALT mode by a transition received on one of the available Wake-
up pins. The pins used and the types of transitions sensed on the Multi-input pins are software
programmable. For information on programming and using the Multi-Input Wake-up feature, refer to Multi-
Input Wake-up.
A start-up delay is required between the device wake-up and the execution of program instructions. The
start-up delay is mandatory, and is implemented whether or not the CLKDLY bit is set. This is because all
crystal oscillators and resonators require some time to reach a stable frequency and full operating
amplitude.
If the start-up delay is used, the IDLE Timer (Timer T0) provides a fixed delay from the time the clock is
enabled to the time the program execution begins. Upon exit from the HALT mode, the IDLE Timer is
enabled with a starting value of 256 and is decremented with each instruction cycle using the high speed
clock. (The instruction clock runs at one-fifth the frequency of the high speed oscillatory.) An internal
Schmitt trigger connected to the on-chip CKI inverter ensures that the IDLE Timer is clocked only when
the high speed oscillator has a large enough amplitude. (The Schmitt trigger is not part of the oscillator
closed loop.) When the IDLE Timer underflows, the clock signals are enabled on the chip, allowing
program execution to proceed. Thus, the delay is equal to 256 instruction cycles. After exiting HALT, the
Idle Timer will return to being clocked by the low speed clock.
NOTE
To ensure accurate operation upon start-up of the device using Multi-input Wake-up, the
instruction in the application program used for entering the HALT mode should be followed
by two consecutive NOP (no-operation) instructions.
5.12.4.1.5 Options
This device has two options associated with the HALT mode. The first option enables the HALT mode
feature, while the second option disables HALT mode operation. Selecting the disable HALT mode option
will cause the microcontroller to ignore any attempts to HALT the device under software control. See
Option Register for more details on this option bit.
5.12.4.2 Dual Clock Idle Mode
In the IDLE mode, program execution stops and power consumption is reduced to a very low level as with
the HALT mode. However, both oscillators, IDLE Timer (Timer T0), and Clock Monitor continue to operate,
allowing real time to be maintained. The Idle Timer is clocked by the low speed clock. The device remains
idle for a selected amount of time up to 1 second, and then automatically exits the IDLE mode and returns
to normal program execution using the high speed clock.
The device is placed in the IDLE mode under software control by setting the IDLE bit (bit 6 of the Port G
data register).
The IDLE Timer window is selectable from one of five values, 0.125 seconds, 0.25 seconds, 0.5 seconds,
1 second and 2 seconds. Selection of this value is made through the ITMR register.
The IDLE mode uses the on-chip IDLE Timer (Timer T0) to keep track of elapsed time in the IDLE state.
The IDLE Timer runs continuously at the low speed clock rate, whether or not the device is in the IDLE
mode. Each time the bit of the timer associated with the selected window toggles, the T0PND bit is set, an
interrupt is generated (if enabled), and the device exits the IDLE mode if in that mode. If the IDLE Timer
interrupt is enabled, the interrupt is serviced before execution of the main program resumes. (However,
the instruction which was started as the part entered the IDLE mode is completed before the interrupt is
serviced. This instruction should be a NOP which should follow the enter IDLE instruction.) The user must
reset the IDLE Timer pending flag (T0PND) before entering the IDLE mode.
As with the HALT mode, this device can also be returned to normal operation with a Multi-Input Wake-up
input.
54 Functional Description Copyright © 2000–2013, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
www.ti.com
SNOS535I OCTOBER 2000REVISED MARCH 2013
The IDLE Timer cannot be started or stopped under software control, and it is not memory mapped, so it
cannot be read or written by the software. Its state upon Reset is unknown. Therefore, if the device is put
into the IDLE mode at an arbitrary time, it will stay in the IDLE mode for somewhere between 30 µs and
the selected time period.
In order to precisely time the duration of the IDLE state, entry into the IDLE mode must be ”synchronized
to the state of the IDLE Timer. The best way to do this is to use the IDLE Timer interrupt, which occurs on
every underflow of the bit of the IDLE Timer which is associated with the selected window. Another
method is to poll the state of the IDLE Timer pending bit T0PND, which is set on the same occurrence.
The Idle Timer interrupt is enabled by setting bit T0EN in the ICNTRL register.
Any time the IDLE Timer window length is changed there is the possibility of generating a spurious IDLE
Timer interrupt by setting the T0PND bit. The user is advised to disable IDLE Timer interrupts prior to
changing the value of the ITSEL bits of the ITMR Register and then clear the T0PND bit before attempting
to synchronize operation to the IDLE Timer.
NOTE
As with the HALT mode, it is necessary to program two NOP's to allow clock
resynchronization upon return from the IDLE mode. The NOP's are placed either at the
beginning of the IDLE Timer interrupt routine or immediately following the “enter IDLE mode”
instruction.
For more information on the IDLE Timer and its associated interrupt, see the description in the Timers
section.
5.12.5 LOW SPEED MODE OPERATION
This mode of operation allows for low speed operation of the core clock and low speed operation of the
Idle Timer. Because the low speed oscillator draws very little operating current, and also to expedite
restarting from HALT mode, the low speed oscillator is left on at all times in this mode, including HALT
mode. This is the lowest power mode of operation on the device. This mode can only be entered from the
Dual Clock mode.
To enter the Low Speed mode, the following sequence must be followed using two separate instructions:
1. Software sets the CCKSEL bit to 1.
2. Software clears the HSON bit to 0.
Since the low speed oscillator is already running, there is no clock startup delay.
5.12.5.1 Low Speed HALT Mode
The fully static architecture of this device allows the state of the microcontroller to be frozen. Because the
low speed oscillator draws very minimal operating current, it will be left running in the low speed halt
mode. However, the Idle Timer will not be running. This also allows for a faster exit from HALT. The
processor can be forced to exit the HALT mode and resume normal operation at any time.
During normal operation, the actual power consumption depends heavily on the clock speed and operating
voltage used in an application and is shown in the Electrical Specifications. In the HALT mode, the device
only draws a small leakage current, plus current for the BOR feature (if enabled), plus the 32 kHz
oscillator current, plus any current necessary for driving the outputs. Since total power consumption is
affected by the amount of current required to drive the outputs, all I/Os should be configured to draw
minimal current prior to entering the HALT mode, if possible.
Copyright © 2000–2013, Texas Instruments Incorporated Functional Description 55
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
SNOS535I OCTOBER 2000REVISED MARCH 2013
www.ti.com
5.12.5.1.1 Entering The Low Speed Halt Mode
The device enters the HALT mode under software control when the Port G data register bit 7 is set to 1.
All processor action stops in the middle of the next instruction cycle, and power consumption is reduced to
a very low level. In order to expedite exit from HALT, the low speed oscillator is left running when the
device is Halted in the Low Speed mode. However, the Idle Timer will not be clocked.
5.12.5.1.2 Exiting The Low Speed Halt Mode
When the HALT mode is entered by setting bit 7 of the Port G data register, there is a choice of methods
for exiting the HALT mode: a chip Reset using the RESET pin or a Multi-Input Wake-up. The Reset
method and Multi-Input Wake-up method can be used with any clock option, but the availability of the G7
input is dependent on the clock option.
5.12.5.1.3 HALT Exit Using Reset
A device Reset, which is invoked by a low-level signal on the RESET input pin, takes the device out of the
Low Speed mode and puts it into the High Speed mode.
5.12.5.1.4 HALT Exit Using Multi-Input Wake-up
The device can be brought out of the HALT mode by a transition received on one of the available Wake-
up pins. The pins used and the types of transitions sensed on the Multi-input pins are software
programmable. For information on programming and using the Multi-Input Wake-up feature, refer to the
Multi-Input Wake-up section.
As the low speed oscillator is left running, there is no start up delay when exiting the low speed halt mode,
regardless of the state of the CLKDLY bit.
NOTE
To ensure accurate operation upon start-up of the device using Multi-input Wake-up, the
instruction in the application program used for entering the HALT mode should be followed
by two consecutive NOP (no-operation) instructions.
5.12.5.1.5 Options
This device has two options associated with the HALT mode. The first option enables the HALT mode
feature, while the second option disables HALT mode operation. Selecting the disable HALT mode option
will cause the microcontroller to ignore any attempts to HALT the device under software control. See the
Option section for more details on this option bit.
5.12.5.2 Low Speed Idle Mode
In the IDLE mode, program execution stops and power consumption is reduced to a very low level as with
the HALT mode. However, the low speed oscillator, IDLE Timer (Timer T0), and Clock Monitor continue to
operate, allowing real time to be maintained. The device remains idle for a selected amount of time up to 2
seconds, and then automatically exits the IDLE mode and returns to normal program execution using the
low speed clock.
The device is placed in the IDLE mode under software control by setting the IDLE bit (bit 6 of the Port G
data register).
The IDLE Timer window is selectable from one of five values, 0.125 seconds, 0.25 seconds, 0.5 seconds,
1 second, and 2 seconds. Selection of this value is made through the ITMR register.
56 Functional Description Copyright © 2000–2013, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
www.ti.com
SNOS535I OCTOBER 2000REVISED MARCH 2013
The IDLE mode uses the on-chip IDLE Timer (Timer T0) to keep track of elapsed time in the IDLE state.
The IDLE Timer runs continuously at the low speed clock rate, whether or not the device is in the IDLE
mode. Each time the bit of the timer associated with the selected window toggles, the T0PND bit is set, an
interrupt is generated (if enabled), and the device exits the IDLE mode if in that mode. If the IDLE Timer
interrupt is enabled, the interrupt is serviced before execution of the main program resumes. (However,
the instruction which was started as the part entered the IDLE mode is completed before the interrupt is
serviced. This instruction should be a NOP which should follow the enter IDLE instruction.) The user must
reset the IDLE Timer pending flag (T0PND) before entering the IDLE mode.
As with the HALT mode, this device can also be returned to normal operation with a Multi-Input Wake-up
input.
The IDLE Timer cannot be started or stopped under software control, and it is not memory mapped, so it
cannot be read or written by the software. Its state upon Reset is unknown. Therefore, if the device is put
into the IDLE mode at an arbitrary time, it will stay in the IDLE mode for somewhere between 30 µs and
the selected time period.
In order to precisely time the duration of the IDLE state, entry into the IDLE mode must be synchronized to
the state of the IDLE Timer. The best way to do this is to use the IDLE Timer interrupt, which occurs on
every underflow of the bit of the IDLE Timer which is associated with the selected window. Another
method is to poll the state of the IDLE Timer pending bit T0PND, which is set on the same occurrence.
The Idle Timer interrupt is enabled by setting bit T0EN in the ICNTRL register.
Any time the IDLE Timer window length is changed there is the possibility of generating a spurious IDLE
Timer interrupt by setting the T0PND bit. The user is advised to disable IDLE Timer interrupts prior to
changing the value of the ITSEL bits of the ITMR Register and then clear the T0PND bit before attempting
to synchronize operation to the IDLE Timer.
As with the HALT mode, it is necessary to program two NOP's to allow clock resynchronization upon
return from the IDLE mode. The NOP's are placed either at the beginning of the IDLE Timer interrupt
routine or immediately following the “enter IDLE mode” instruction.
For more information on the IDLE Timer and its associated interrupt, see the description in the Timer T0
(IDLE Timer).
Figure 5-15. Multi-Input Wake-Up Logic
Copyright © 2000–2013, Texas Instruments Incorporated Functional Description 57
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
SNOS535I OCTOBER 2000REVISED MARCH 2013
www.ti.com
5.12.6 MULTI-INPUT WAKE-UP
The Multi-Input Wake-up feature is used to return (wake-up) the device from either the HALT or IDLE
modes. Alternately Multi-Input Wake-up/Interrupt feature may also be used to generate up to 8 edge
selectable external interrupts.
Figure 5-15 shows the Multi-Input Wake-up logic.
The Multi-Input Wake-up feature utilizes the L Port. The user selects which particular L port bit (or
combination of L Port bits) will cause the device to exit the HALT or IDLE modes. The selection is done
through the register WKEN. The register WKEN is an 8-bit read/write register, which contains a control bit
for every L port bit. Setting a particular WKEN bit enables a Wake-up from the associated L port pin.
The user can select whether the trigger condition on the selected L Port pin is going to be either a positive
edge (low to high transition) or a negative edge (high to low transition). This selection is made via the
register WKEDG, which is an 8-bit control register with a bit assigned to each L Port pin. Setting the
control bit will select the trigger condition to be a negative edge on that particular L Port pin. Resetting the
bit selects the trigger condition to be a positive edge. Changing an edge select entails several steps in
order to avoid a Wake-up condition as a result of the edge change. First, the associated WKEN bit should
be reset, followed by the edge select change in WKEDG. Next, the associated WKPND bit should be
cleared, followed by the associated WKEN bit being re-enabled.
An example may serve to clarify this procedure. Suppose we wish to change the edge select from positive
(low going high) to negative (high going low) for L Port bit 5, where bit 5 has previously been enabled for
an input interrupt. The program would be as follows:
RBIT 5, WKEN ; Disable MIWU
SBIT 5, WKEDG ; Change edge polarity
RBIT 5, WKPND ; Reset pending flag
SBIT 5, WKEN ; Enable MIWU
If the L port bits have been used as outputs and then changed to inputs with Multi-Input Wake-
up/Interrupt, a safety procedure should also be followed to avoid wake-up conditions. After the selected L
port bits have been changed from output to input but before the associated WKEN bits are enabled, the
associated edge select bits in WKEDG should be set or reset for the desired edge selects, followed by the
associated WKPND bits being cleared.
This same procedure should be used following reset, since the L port inputs are left floating as a result of
reset.
The occurrence of the selected trigger condition for Multi-Input Wake-up is latched into a pending register
called WKPND. The respective bits of the WKPND register will be set on the occurrence of the selected
trigger edge on the corresponding Port L pin. The user has the responsibility of clearing these pending
flags. Since WKPND is a pending register for the occurrence of selected wake-up conditions, the device
will not enter the HALT mode if any Wake-up bit is both enabled and pending. Consequently, the user
must clear the pending flags before attempting to enter the HALT mode.
WKEN and WKEDG are all read/write registers, and are cleared at reset. WKPND register contains
random value after reset.
5.13 USART
The device contains a full-duplex software programmable USART. The USART (Figure 5-16) consists of a
transmit shift register, a receive shift register and seven addressable registers, as follows: a transmit
buffer register (TBUF), a receiver buffer register (RBUF), a USART control and status register (ENU), a
USART receive control and status register (ENUR), a USART interrupt and clock source register (ENUI), a
prescaler select register (PSR) and baud (BAUD) register. The ENU register contains flags for transmit
and receive functions; this register also determines the length of the data frame (7, 8 or 9 bits), the value
of the ninth bit in transmission, and parity selection bits. The ENUR register flags framing, data overrun,
parity errors and line breaks while the USART is receiving.
58 Functional Description Copyright © 2000–2013, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
www.ti.com
SNOS535I OCTOBER 2000REVISED MARCH 2013
Other functions of the ENUR register include saving the ninth bit received in the data frame, enabling or
disabling the USART's attention mode of operation and providing additional receiver/transmitter status
information via RCVG and XMTG bits. The determination of an internal or external clock source is done by
the ENUI register, as well as selecting the number of stop bits and enabling or disabling transmit and
receive interrupts. A control flag in this register can also select the USART mode of operation:
asynchronous or synchronous.
Figure 5-16. USART Block Diagram
5.13.1 USART CONTROL AND STATUS REGISTERS
The operation of the USART is programmed through three registers: ENU, ENUR and ENUI.
5.13.2 DESCRIPTION OF USART REGISTER BITS
ENU—USART CONTROL AND STATUS REGISTER (Address at 0BA)
Copyright © 2000–2013, Texas Instruments Incorporated Functional Description 59
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
SNOS535I OCTOBER 2000REVISED MARCH 2013
www.ti.com
PEN PSEL1 XBIT9/ CHL1 CHL0 ERR RBFL TBMT
PSEL0
Bit 7 Bit 0
PEN: This bit enables/disables Parity (7- and 8-bit modes only). Read/Write, cleared on reset.
PEN = 0 Parity disabled.
PEN = 1 Parity enabled.
PSEL1, PSEL0: Parity select bits. Read/Write, cleared on reset.
PSEL1 = 0, PSEL0 = 0 Odd Parity (if Parity enabled)
PSEL1 = 0, PSEL1 = 1 Even Parity (if Parity enabled)
PSEL1 = 1, PSEL0 = 0 Mark(1) (if Parity enabled)
PSEL1 = 1, PSEL1 = 1 Space(0) (if Parity enabled)
XBIT9/PSEL0: Programs the ninth bit for transmission when the USART is operating with nine data bits
per frame. For seven or eight data bits per frame, this bit in conjunction with PSEL1 selects parity.
Read/Write, cleared on reset.
CHL1, CHL0: These bits select the character frame format. Parity is not included and is generated/verified
by hardware. Read/Write, cleared on reset.
CHL1 = 0, CHL0 = 0 The frame contains eight data bits.
CHL1 = 0, CHL0 = 1 The frame contains seven data bits.
CHL1 = 1, CHL0 = 0 The frame contains nine data bits.
CHL1 = 1, CHL0 = 1 Loopback Mode selected. Transmitter output internally looped back to receiver
input. Nine bit framing format is used.
ERR: This bit is a global USART error flag which gets set if any or a combination of the errors (DOE, FE,
PE, BD) occur. Read only; it cannot be written by software, cleared on reset.
RBFL: This bit is set when the USART has received a complete character and has copied it into the
RBUF register. It is automatically reset when software reads the character from RBUF. Read only; it
cannot be written by software, cleared on reset.
TBMT: This bit is set when the USART transfers a byte of data from the TBUF register into the TSFT
register for transmission. It is automatically reset when software writes into the TBUF register. Read only,
bit is set to “one” on reset; it cannot be written by software.
ENUR—USART RECEIVE CONTROL AND STATUS REGISTER (Address at 0BB)
DOE FE PE BD RBIT9 ATTN XMTG RCVG
Bit 7 Bit 0
DOE: Flags a Data Overrun Error. Read only, cleared on read, cleared on reset.
DOE = 0 Indicates no Data Overrun Error has been detected since the last time the ENUR register
was read.
DOE = 1 Indicates the occurrence of a Data Overrun Error.
FE: Flags a Framing Error. Read only, cleared on read, cleared on reset.
FE = 0 Indicates no Framing Error has been detected since the last time the ENUR register was
read.
FE = 1 Indicates the occurrence of a Framing Error.
PE: Flags a Parity Error. Read only, cleared on read, cleared on reset.
60 Functional Description Copyright © 2000–2013, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
www.ti.com
SNOS535I OCTOBER 2000REVISED MARCH 2013
PE = 0 Indicates no Parity Error has been detected since the last time the ENUR register was read.
PE = 1 Indicates the occurrence of a Parity Error.
BD: Flags a line break.
BD = 0 Indicates no Line Break has been detected since the last time the ENUR register was read.
BD = 1 Indicates the occurrence of a Line Break.
RBIT9: Contains the ninth data bit received when the USART is operating with nine data bits per frame.
Read only, cleared on reset.
ATTN: ATTENTION Mode is enabled while this bit is set. This bit is cleared automatically on receiving a
character with data bit nine set. Read/Write, cleared on reset.
XMTG: This bit is set to indicate that the USART is transmitting. It gets reset at the end of the last frame
(end of last Stop bit). Read only, cleared on reset.
RCVG: This bit is set high whenever a framing error or a break detect occurs and goes low when RDX
goes high. Read only, cleared on reset.
ENUI—USART INTERRUPT AND CLOCK SOURCE REGISTER (Address at 0BC)
STP2 BRK ETDX SSEL XRCLK XTCLK ERI ETI
Bit 7 Bit 0
STP2: This bit programs the number of Stop bits to be transmitted. Read/Write, cleared on reset.
STP2 = 0 One Stop bit transmitted.
STP2 = 1 Two Stop bits transmitted.
BRK: Holds TDX (USART Transmit Pin) low to generate a Line Break. Timing of the Line Break is under
software control.
ETDX: TDX (USART Transmit Pin) is the alternate function assigned to Port L pin L2; it is selected by
setting ETDX bit.
SSEL: USART mode select. Read only, cleared on reset.
SSEL = 0 Asynchronous Mode.
SSEL = 1 Synchronous Mode.
XRCLK: This bit selects the clock source for the receiver section. Read/Write, cleared on reset.
XRCLK = 0 The clock source is selected through the PSR and BAUD registers.
XRCLK = 1 Signal on CKX (L1) pin is used as the clock.
XTCLK: This bit selects the clock source for the transmitter section. Read/Write, cleared on reset.
XTCLK = 0 The clock source is selected through the PSR and BAUD registers.
XTCLK = 1 Signal on CKX (L1) pin is used as the clock.
ERI: This bit enables/disables interrupt from the receiver section. Read/Write, cleared on reset.
ERI = 0 Interrupt from the receiver is disabled.
ERI = 1 Interrupt from the receiver is enabled.
ETI: This bit enables/disables interrupt from the transmitter section. Read/Write, cleared on reset.
ETI = 0 Interrupt from the transmitter is disabled.
ETI = 1 Interrupt from the transmitter is enabled.
Copyright © 2000–2013, Texas Instruments Incorporated Functional Description 61
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
SNOS535I OCTOBER 2000REVISED MARCH 2013
www.ti.com
5.13.3 ASSOCIATED I/O PINS
Data is transmitted on the TDX pin and received on the RDX pin. TDX is the alternate function assigned to
Port L pin L2; it is selected by setting ETDX (in the ENUI register) to one. RDX is an inherent function Port
L pin L3, requiring no setup. Port L pin L2 must be configured as an output in the Port L Configuration
Register in order to be used as the TDX pin.
The baud rate clock for the USART can be generated on-chip, or can be taken from an external source.
Port L pin L1 (CKX) is the external clock I/O pin. The CKX pin can be either an input or an output, as
determined by Port L Configuration and Data registers (Bit 1). As an input, it accepts a clock signal which
may be selected to drive the transmitter and/or receiver. As an output, it presents the internal Baud Rate
Generator output.
NOTE
The CKX pin is unavailable if Port L1 is used for the Low Speed Oscillator.
5.13.4 USART OPERATION
The USART has two modes of operation: asynchronous mode and synchronous mode.
5.13.4.1 Asynchronous Mode
This mode is selected by resetting the SSEL (in the ENUI register) bit to zero. The input frequency to the
USART is 16 times the baud rate.
The TSFT and TBUF registers double-buffer data for transmission. While TSFT is shifting out the current
character on the TDX pin, the TBUF register may be loaded by software with the next byte to be
transmitted. When TSFT finishes transmitting the current character the contents of TBUF are transferred
to the TSFT register and the Transmit Buffer Empty Flag (TBMT in the ENU register) is set. The TBMT
flag is automatically reset by the USART when software loads a new character into the TBUF register.
There is also the XMTG bit which is set to indicate that the USART is transmitting. This bit gets reset at
the end of the last frame (end of last Stop bit). TBUF is a read/write register.
The RSFT and RBUF registers double-buffer data being received. The USART receiver continually
monitors the signal on the RDX pin for a low level to detect the beginning of a Start bit. Upon sensing this
low level, it waits for half a bit time and samples again. If the RDX pin is still low, the receiver considers
this to be a valid Start bit, and the remaining bits in the character frame are each sampled a three times
around the center of the bit time. Serial data input on the RDX pin is shifted into the RSFT register. Upon
receiving the complete character, the contents of the RSFT register are copied into the RBUF register and
the Received Buffer Full Flag (RBFL) is set. RBFL is automatically reset when software reads the
character from the RBUF register. RBUF is a read only register. There is also the RCVG bit which is set
high when a framing error or a break detect occurs and goes low once RDX goes high.
5.13.4.2 Synchronous Mode
In this mode data is transferred synchronously with the clock. Data is transmitted on the rising edge and
received on the falling edge of the synchronous clock.
This mode is selected by setting SSEL bit in the ENUI register. The input frequency to the USART is the
same as the baud rate.
When an external clock input is selected at the CKX pin, data transmit and receive are performed
synchronously with this clock through TDX/RDX pins.
If data transmit and receive are selected with the CKX pin as clock output, the device generates the
synchronous clock output at the CKX pin. The internal baud rate generator is used to produce the
synchronous clock. Data transmit and receive are performed synchronously with this clock.
62 Functional Description Copyright © 2000–2013, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
www.ti.com
SNOS535I OCTOBER 2000REVISED MARCH 2013
5.13.5 FRAMING FORMATS
The USART supports several serial framing formats (Figure 5-17). The format is selected using control
bits in the ENU, ENUR and ENUI registers.
The first format (1, 1a, 1b, 1c) for data transmission (CHL0 = 1, CHL1 = 0) consists of Start bit, seven
Data bits (excluding parity) and one or two Stop bits. In applications using parity, the parity bit is
generated and verified by hardware.
The second format (CHL0 = 0, CHL1 = 0) consists of one Start bit, eight Data bits (excluding parity) and
7/8, one or two Stop bits. Parity bit is generated and verified by hardware.
The third format for transmission (CHL0 = 0, CHL1 = 1) consists of one Start bit, nine Data bits and one or
two Stop bits. This format also supports the USART “ATTENTION” feature. When operating in this format,
all eight bits of TBUF and RBUF are used for data. The ninth data bit is transmitted and received using
two bits in the ENU and ENUR registers, called XBIT9 and RBIT9. RBIT9 is a read only bit. Parity is not
generated or verified in this mode.
The parity is enabled/disabled by PEN bit located in the ENU register. Parity is selected for 7- and 8-bit
modes only. If parity is enabled (PEN = 1), the parity selection is then performed by PSEL0 and PSEL1
bits located in the ENU register.
Note that the XBIT9/PSEL0 bit located in the ENU register serves two mutually exclusive functions. This
bit programs the ninth bit for transmission when the USART is operating with nine data bits per frame.
There is no parity selection in this framing format. For other framing formats XBIT9 is not needed and the
bit is PSEL0 used in conjunction with PSEL1 to select parity.
The frame formats for the receiver differ from the transmitter in the number of Stop bits required. The
receiver only requires one Stop bit in a frame, regardless of the setting of the Stop bit selection bits in the
control register. Note that an implicit assumption is made for full duplex USART operation that the framing
formats are the same for the transmitter and receiver.
Copyright © 2000–2013, Texas Instruments Incorporated Functional Description 63
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
SNOS535I OCTOBER 2000REVISED MARCH 2013
www.ti.com
Figure 5-17. Framing Formats
5.13.6 USART INTERRUPTS
The USART is capable of generating interrupts. Interrupts are generated on Receive Buffer Full and
Transmit Buffer Empty. Both interrupts have individual interrupt vectors. Two bytes of program memory
space are reserved for each interrupt vector. The two vectors are located at addresses 0xEC to 0xEF Hex
in the program memory space. The interrupts can be individually enabled or disabled using Enable
Transmit Interrupt (ETI) and Enable Receive Interrupt (ERI) bits in the ENUI register.
The interrupt from the Transmitter is set pending, and remains pending, as long as both the TBMT and
ETI bits are set. To remove this interrupt, software must either clear the ETI bit or write to the TBUF
register (thus clearing the TBMT bit).
The interrupt from the receiver is set pending, and remains pending, as long as both the RBFL and ERI
bits are set. To remove this interrupt, software must either clear the ERI bit or read from the RBUF register
(thus clearing the RBFL bit).
64 Functional Description Copyright © 2000–2013, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
www.ti.com
SNOS535I OCTOBER 2000REVISED MARCH 2013
5.13.7 BAUD CLOCK GENERATION
The clock inputs to the transmitter and receiver sections of the USART can be individually selected to
come either from an external source at the CKX pin (port L, pin L1) or from a source selected in the PSR
and BAUD registers. Internally, the basic baud clock is created from the MCLK through a two-stage divider
chain consisting of a 1-16 (increments of 0.5) prescaler and an 11-bit binary counter (Figure 5-18). The
divide factors are specified through two read/write registers shown in Figure 5-19. Note that the 11-bit
Baud Rate Divisor spills over into the Prescaler Select Register (PSR). PSR is cleared upon reset.
As shown in Table 5-17, a Prescaler Factor of 0 corresponds to NO CLOCK. This condition is the USART
power down mode where the USART clock is turned off for power saving purpose. The user must also
turn the USART clock off when a different baud rate is chosen.
The correspondences between the 5-bit Prescaler Select and Prescaler factors are shown in Table 5-17.
There are many ways to calculate the two divisor factors, but one particularly effective method would be to
achieve a 1.8432 MHz frequency coming out of the first stage. The 1.8432 MHz prescaler output is then
used to drive the software programmable baud rate counter to create a 16x clock for the following baud
rates: 110, 134.5, 150, 300, 600, 1200, 1800, 2400, 3600, 4800, 7200, 9600, 19200 and 38400 (Table 5-
16). Other baud rates may be created by using appropriate divisors. The 16x clock is then divided by 16 to
provide the rate for the serial shift registers of the transmitter and receiver.
Table 5-16. Baud Rate Divisors
(1.8432 MHz Prescaler Output)(1)
Baud Rate
Baud Rate Divisor 1 (N-1)
110 (110.03) 1046
134.5 (134.58) 855
150 767
300 383
600 191
1200 95
1800 63
2400 47
3600 31
4800 23
7200 15
9600 11
19200 5
38400 2
(1) The entries in Table 5-16 assume a prescaler output of 1.8432 MHz.
In asynchronous mode the baud rate could be as high as 1250k.
Figure 5-18. USART BAUD Clock Generation
Copyright © 2000–2013, Texas Instruments Incorporated Functional Description 65
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
SNOS535I OCTOBER 2000REVISED MARCH 2013
www.ti.com
Table 5-17. Prescaler Factors
Prescaler Prescaler
Select Factor
00000 NO CLOCK
00001 1
00010 1.5
00011 2
00100 2.5
00101 3
00110 3.5
00111 4
01000 4.5
01001 5
01010 5.5
01011 6
01100 6.5
01101 7
01110 7.5
01111 8
10000 8.5
10001 9
10010 9.5
10011 10
10100 10.5
10101 11
10110 11.5
10111 12
11000 12.5
11001 13
11010 13.5
11011 14
11100 14.5
11101 15
11110 15.5
11111 16
As an example, considering Asynchronous Mode and a crystal frequency of 4.608 MHz, the prescaler
factor selected is: (4.608 x 2)/1.8432 = 5
The 5 entry is available in Table 5-17. The 1.8432 MHz prescaler output is then used with proper Baud
Rate Divisor (Table 5-16) to obtain different baud rates. For a baud rate of 19200 e.g., the entry in
Table 5-16 is 5.
N1=5(N1 is the value from Table 5-16)
N = 6 (N is the Baud Rate Divisor)
Baud Rate = 1.8432 MHz/(16 x 6) = 19200
The divide by 16 is performed because in the asynchronous mode, the input frequency to the USART is
16 times the baud rate. The equation to calculate baud rates is given below.
The actual Baud Rate may be found from: BR = (FCx 2)/(16 x N x P)
66 Functional Description Copyright © 2000–2013, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
www.ti.com
SNOS535I OCTOBER 2000REVISED MARCH 2013
Where:
BR is the Baud Rate
FCis the crystal frequency
N is the Baud Rate Divisor (Table 5-16)
P is the Prescaler Divide Factor selected by the value in the Prescaler Select Register (Table 5-17)
NOTE
In the Synchronous Mode, the divisor 16 is replaced by two.
Example:
Asynchronous Mode:
Crystal Frequency = 5 MHz
Desired baud rate = 19200
Using the above equation N × P can be calculated first.
N × P = (5 x 106x 2)/(16 x 19200) = 32.552
Now 32.552 is divided by each Prescaler Factor (Table 5-17) to obtain a value closest to an integer. This
factor happens to be 6.5 (P = 6.5). N = 32.552/6.5 = 5.008 (N = 5)
The programmed value (from Table 5-16) should be 4 (N - 1).
Using the above values calculated for N and P:
BR = (5 x 106x 2)/(16 x 5 x 6.5) = 19230.769
error = (19230.769 - 19200) x 100/19200 = 0.16%
Figure 5-19. USART BAUD Clock Divisor Registers
5.13.8 EFFECT OF HALT/IDLE
The USART logic is reinitialized when either the HALT or IDLE modes are entered. This reinitialization
sets the TBMT flag and resets all read only bits in the USART control and status registers. Read/Write bits
remain unchanged. The Transmit Buffer (TBUF) is not affected, but the Transmit Shift register (TSFT) bits
are set to one. The receiver registers RBUF and RSFT are not affected.
The device will exit from the HALT/IDLE modes when the Start bit of a character is detected at the RDX
(L3) pin. This feature is obtained by using the Multi-Input Wake-up scheme provided on the device.
Before entering the HALT or IDLE modes the user program must select the Wake-up source to be on the
RDX pin. This selection is done by setting bit 3 of WKEN (Wake-up Enable) register. The Wake-up trigger
condition is then selected to be high to low transition. This is done via the WKEDG register (Bit 3 is one).
If the device is halted and crystal oscillator is used, the Wake-up signal will not start the chip running
immediately because of the finite start up time requirement of the crystal oscillator. The idle timer (T0)
generates a fixed (256 tC) delay to ensure that the oscillator has indeed stabilized before allowing the
device to execute code. The user has to consider this delay when data transfer is expected immediately
after exiting the HALT mode.
Copyright © 2000–2013, Texas Instruments Incorporated Functional Description 67
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
SNOS535I OCTOBER 2000REVISED MARCH 2013
www.ti.com
5.13.9 DIAGNOSTIC
Bits CHL0 and CHL1 in the ENU register provide a loopback feature for diagnostic testing of the USART.
When both bits are set to one, the following occurs: The receiver input pin (RDX) is internally connected to
the transmitter output pin (TDX); the output of the Transmitter Shift Register is “looped back” into the
Receive Shift Register input. In this mode, data that is transmitted is immediately received. This feature
allows the processor to verify the transmit and receive data paths of the USART.
Note that the framing format for this mode is the nine bit format; one Start bit, nine data bits, and one or
two Stop bits. Parity is not generated or verified in this mode.
5.13.10 ATTENTION MODE
The USART Receiver section supports an alternate mode of operation, referred to as ATTENTION Mode.
This mode of operation is selected by the ATTN bit in the ENUR register. The data format for transmission
must also be selected as having nine Data bits and either one or two Stop bits.
The ATTENTION mode of operation is intended for use in networking the device with other processors.
Typically in such environments the messages consists of device addresses, indicating which of several
destinations should receive them, and the actual data. This Mode supports a scheme in which addresses
are flagged by having the ninth bit of the data field set to a 1. If the ninth bit is reset to a zero the byte is a
Data byte.
While in ATTENTION mode, the USART monitors the communication flow, but ignores all characters until
an address character is received. Upon receiving an address character, the USART signals that the
character is ready by setting the RBFL flag, which in turn interrupts the processor if USART Receiver
interrupts are enabled. The ATTN bit is also cleared automatically at this point, so that data characters as
well as address characters are recognized. Software examines the contents of the RBUF and responds by
deciding either to accept the subsequent data stream (by leaving the ATTN bit reset) or to wait until the
next address character is seen (by setting the ATTN bit again).
Operation of the USART Transmitter is not affected by selection of this Mode. The value of the ninth bit to
be transmitted is programmed by setting XBIT9 appropriately. The value of the ninth bit received is
obtained by reading RBIT9. Since this bit is located in ENUR register where the error flags reside, a bit
operation on it will reset the error flags.
5.13.11 BREAK GENERATION
To generate a line break, the user software should set the BRK bit in the ENUI register. This will force the
TDX pin to 0 and hold it there until the BRK bit is reset.
5.14 A/D Converter
This device contains a 16-channel, multiplexed input, successive approximation, 10 bit Analog-to-Digital
Converter. Pins AVCC and AGND are used for the voltage reference.
5.14.1 OPERATING MODES
It supports both Single Ended and Differential modes of operation.
Two specific analog channel selection modes are supported. These are as follows:
1. Allow any specific channel to be selected at one time. The A/D Converter performs the specific
conversion requested and stops.
2. Allow any differential channel pair to be selected at one time. The A/D Converter performs the specific
differential conversion requested and stops.
In both Single Ended and Differential modes, there is the capability to connect the analog multiplexor
output and A/D converter input to external pins. This provides the ability to externally connect a common
filter/signal conditioning circuit for the A/D Converter.
68 Functional Description Copyright © 2000–2013, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
www.ti.com
SNOS535I OCTOBER 2000REVISED MARCH 2013
The A/D Converter is supported by three memory mapped registers: two result registers and the control
register. When the device is reset, the mode control register (ENAD) is cleared, the A/D is powered down
and the A/D result registers have unknown data.
5.14.1.1 A/D Control Register
The control register, ENAD, contains 4 bits for channel selection, 1 bit for mode selection, 1 bit for the
multiplexor output selection, 1 bit for prescaler selection, and a Busy bit. An A/D conversion is initiated by
setting the ADBSY bit in the ENAD control register. The result of the conversion is available to the user in
the A/D result registers, ADRSTH and ADRSTL, when ADBSY is cleared by the hardware on completion
of the conversion.
Table 5-18. ENAD
Bit 7 Bit 0
Channel Select Mode Mux/Out Prescale Busy
Select
ADCH3 ADCH2 ADCH1 ADCH0 ADMOD MUX PSC ADBSY
5.14.1.1.1 Channel Select
This 4-bit field selects one of sixteen channels to be the VIN+. The mode selection and the mux output
determine the VIN-input. When MUX = 0, all sixteen channels are available, as shown in Table 5-19. When
MUX = 1, only fourteen channels are available, as shown in Table 5-20.
All port pins which are used, in the application, in A/D operations must be configured as high-impedance
inputs. If the ports are configured as outputs or inputs with weak pull-up there will be a conflict between
the analog signal and the digitally driven output.
Table 5-19. A/D Converter Channel Selection when the Multiplexor Output is Disabled
Mode Select Mode Select
ADMOD = 0 Mux Output
Select Bits ADMOD = 1
Single Ended Disabled
Differential Mode
Mode
ADCH3 ADCH2 ADCH1 ADCH0 Channel No. Channel Pairs (+, MUX
)
0 0 0 0 0 0, 1 0
0 0 0 1 1 1, 0 0
0 0 1 0 2 2, 3 0
0 0 1 1 3 3, 2 0
0 1 0 0 4 4, 5 0
0 1 0 1 5 5, 4 0
0 1 1 0 6 6, 7 0
0 1 1 1 7 7, 6 0
1 0 0 0 8 8, 9 0
1 0 0 1 9 9, 8 0
1 0 1 0 10 10, 11 0
1 0 1 1 11 11, 10 0
1 1 0 0 12 12, 13 0
1 1 0 1 13 13, 12 0
1 1 1 0 14 14, 15 0
1 1 1 1 15 15, 14 0
Copyright © 2000–2013, Texas Instruments Incorporated Functional Description 69
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
SNOS535I OCTOBER 2000REVISED MARCH 2013
www.ti.com
Table 5-20. A/D Converter Channel Selection when the Multiplexor Output is Enabled
Mode Select Mode Select
ADMOD = 0 Mux Output
Select Bits ADMOD = 1
Single Ended Enabled
Differential Mode
Mode
ADCH3 ADCH2 ADCH1 ADCH0 Channel No. Channel Pairs (+, MUX
)
0 0 0 0 0 0, 1 1
0 0 0 1 1 1, 0 1
0 0 1 0 2 2, 3 1
0 0 1 1 3 3, 2 1
0 1 0 0 4 4, 5 1
0 1 0 1 5 5, 4 1
0 1 1 0 6 6, 7 1
0 1 1 1 7 7, 6 1
1 0 0 0 8 8, 9 1
1 0 0 1 9 9, 8 1
1 0 1 0 10 10, 11 1
1 0 1 1 11 11, 10 1
1 1 0 0 12 Not Used(1) 1
1 1 0 1 13 ADC13 is 1
Mux Output
See(1)
1 1 1 0 ADCH14 is ADCH14 is 1
Mux Output(2) Mux Output +
See (2)
1 1 1 1 ADCH15 is ADCH15 is 1
A/D Input(2) A/D Input(2)
(1) This Input Channel Selection should not be used in Differential Mode when the Multiplexor Output is enabled.
(2) This Input Channel Selection should not be used when the Multiplexor Output is enabled.
5.14.1.1.2 Multiplexor Output Select
This 1-bit field allows the output of the A/D multiplexor and the input to the A/D to be connected directly to
external pins. This allows for an external, common filter/signal conditioning circuit to be applied to all
channels. The output of the external conditioning circuit can then be connected directly to the input of the
Sample and Hold input on the A/D Converter. See Figure 5-20 for the single ended mode diagram. The
Multiplexor output is connected to ADCH14 and the A/D input is connected to ADCH15. For Differential
mode, the differential multiplexor outputs are available and should be converted to a single ended voltage
for connection to the A/D Converter Input. See Figure 5-21.
The channel assignments for this mode are shown in Table 5-21.
When using the Mux Output feature, the delay though the internal multiplexor to the pin, plus the delay of
the external filter circuit, plus the internal delay to the Sample and Hold will exceed the three clock cycles
that's allowed in the conversion. This adds the requirement that, whenever the MUX bit = 1, that the
channel selected by ADCH3:0 bits be enabled, even when ADBSY = 0, and gated to the mux output pin.
The input path to the A/D converter is also enabled. This allows the input channel to be selected and
settled before starting a conversion. The sequence to perform conversions using the Mux Out feature is a
multistep process and is listed below.
1. Select the desired channel and operating modes and load them into ENAD without setting ADBSY.
2. Wait the appropriate time until the analog input has settled. This will depend on the application and the
response of the external circuit.
3. Select the same desired channel and operating modes used in step 1 and load them into ENAD and
also set ADBSY or set ADBSY by using the SBIT instruction. This will start the conversion.
70 Functional Description Copyright © 2000–2013, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
www.ti.com
SNOS535I OCTOBER 2000REVISED MARCH 2013
4. Poll ADBSY until it is cleared by the hardware. This indicates the completion of the conversion.
5. Obtain the results from the result registers.
The port pins used for the multiplexor output must be configured as high impedance inputs. If the port pins
are configured as outputs, or as inputs with weak pull-up, there will be a conflict between the analog signal
output and the digitally driven output.
Figure 5-20. A/D with Single Ended Mux Output Feature Enabled
Figure 5-21. A/D with Differential Mux Output Feature Enabled
5.14.1.1.3 Mode Select
This 1-bit field is used to select the mode of operation (single ended or differential) as shown in the
following Table 5-21.
Table 5-21. A/D Conversion Mode Selection
ADMOD Mode
0 Single Ended Mode
1 Differential Mode
5.14.1.1.4 Prescaler Select
This 1-bit field is used to select one of two prescaler clocks for the A/D Converter. The following Table 5-
22 shows the various prescaler options. Care must be taken, when selecting this bit, to keep the A/D clock
frequency within the specified range.
Table 5-22. A/D Converter Clock Prescale
PSC Clock Select
0 MCLK Divide by 1
1 MCLK Divide by 16
Copyright © 2000–2013, Texas Instruments Incorporated Functional Description 71
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
SNOS535I OCTOBER 2000REVISED MARCH 2013
www.ti.com
5.14.1.1.5 Busy Bit
The ADBSY bit of the ENAD register is used to control starting and stopping of the A/D conversion. When
ADBSY is cleared, the prescale logic is disabled and the A/D clock is turned off, drawing minimal power.
Setting the ADBSY bit starts the A/D clock and initiates a conversion based on the values currently in the
ENAD register. Normal completion of an A/D conversion clears the ADBSY bit and turns off the A/D
Converter.
If the user wishes to restart a conversion which is already in progress, this can be accomplished only by
writing a zero to the ADBSY bit to stop the current conversion and then by writing a one to ADBSY to start
a new conversion. This can be done in two consecutive instructions.
5.14.1.2 A/D Result Registers
There are two result registers for the A/D converter: the high 8 bits of the result and the low 2-bits of the
result. The format of these registers is shown in Figure 5-21,Figure 5-22. Both registers are read/write
registers, but in normal operation, the hardware writes the value into the register when the conversion is
complete and the software reads the value. Both registers are undefined upon Reset. They hold the
previous value until a new conversion overwrites them. When reading ADRSTL, bits 5-0 will read as 0.
Table 5-23. ADRSTH
Bit 7 Bit 0
Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2
Table 5-24. ADRSTL
Bit 7 Bit 0
Bit 1 Bit 0 0 0 0 0 0 0
5.14.2 A/D OPERATION
The A/D conversion is completed within fifteen A/D converter clocks. The A/D Converter interface works
as follows. Setting the ADBSY bit in the A/D control register ENAD initiates an A/D conversion. The
conversion sequence starts at the beginning of the write to ENAD operation which sets ADBSY, thus
powering up the A/D. At the first edge of the Converter clock following the write operation, the sample
signal turns on for three clock cycles. At the end of the conversion, the internal conversion complete signal
will clear the ADBSY bit and power down the A/D. The A/D 10-bit result is immediately loaded into the A/D
result registers (ADRSTH and ADRSTL) upon completion.
Inadvertent changes to the ENAD register during conversion are prevented by the control logic of the A/D.
Any attempt to write any bit of the ENAD Register except ADBSY, while ADBSY is a one, is ignored.
ADBSY must be cleared either by completion of an A/D conversion or by the user before the prescaler,
conversion mode or channel select values can be changed. After stopping the current conversion, the
user can load different values for the prescaler, conversion mode or channel select and start a new
conversion in one instruction.
5.14.2.1 Prescaler
The A/D Converter (A/D) contains a prescaler option that allows two different clock speed selections as
shown in Table 5-22. The A/D clock frequency is equal to MCLK divided by the prescaler value. Note that
the prescaler value must be chosen such that the A/D clock falls within the specified range. The maximum
A/D frequency is 1.25 MHz. This equates to a 800 ns A/D clock cycle.
72 Functional Description Copyright © 2000–2013, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
www.ti.com
SNOS535I OCTOBER 2000REVISED MARCH 2013
The A/D Converter takes 15 A/D clock cycles to complete a conversion. Thus the minimum A/D
conversion time is 12.0 µs when a prescaler of 16 has been selected with MCLK = 20 MHz. The 15 A/D
clock cycles needed for conversion consist of 3 cycles for sampling, 1 cycle for auto-zeroing the
comparator, 10 cycles for converting, 1 cycle for loading the result into the result registers, for stopping
and for re-initializing. The ADBSY flag provides an A/D clock inhibit function, which saves power by
powering down the A/D when it is not in use.
NOTE
The A/D Converter is also powered down when the device is in either the HALT or IDLE
modes. If the A/D is running when the device enters the HALT or IDLE modes, the A/D
powers down and then restarts the conversion from the beginning with a corrupted sampled
voltage (and thus an invalid result) when the device comes out of the HALT or IDLE modes.
5.14.3 ANALOG INPUT AND SOURCE RESISTANCE CONSIDERATIONS
Figure 5-22 shows the A/D pin model in single ended mode. The differential mode has a similar A/D pin
model. The leads to the analog inputs should be kept as short as possible. Both noise and digital clock
coupling to an A/D input can cause conversion errors. The clock lead should be kept away from the
analog input line to reduce coupling.
Source impedances greater than 3 kon the analog input lines will adversely affect the internal RC
charging time during input sampling. As shown in Figure 5-22, the analog switch to the DAC array is
closed only during the 3 A/D cycle sample time. Large source impedances on the analog inputs may result
in the DAC array not being charged to the correct voltage levels, causing scale errors.
If large source resistance is necessary, the recommended solution is to slow down the A/D clock speed in
proportion to the source resistance. The A/D Converter may be operated at the maximum speed for RS
less than 3 k. For RSgreater than 3 k, A/D clock speed needs to be reduced. For example, with RS= 6
k, the A/D Converter may be operated at half the maximum speed. A/D Converter clock speed may be
slowed down by either increasing the A/D prescaler divide-by or decreasing the CKI clock frequency. The
A/D minimum clock speed is 65.536 kHz.
*The analog switch is closed only during the sample time.
Figure 5-22. A/D Pin Model (Single Ended Mode)
5.15 Interrupts
5.15.1 INTRODUCTION
The device supports fourteen vectored interrupts. Interrupt sources include Timer 1, Timer 2, Timer 3,
Timer T0, Port L Wake-up, Software Trap, MICROWIRE/PLUS, USART and External Input.
All interrupts force a branch to location 00FF Hex in program memory. The VIS instruction may be used to
vector to the appropriate service routine from location 00FF Hex.
The Software trap has the highest priority while the default VIS has the lowest priority.
Each of the 13 maskable inputs has a fixed arbitration ranking and vector.
Copyright © 2000–2013, Texas Instruments Incorporated Functional Description 73
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
SNOS535I OCTOBER 2000REVISED MARCH 2013
www.ti.com
Figure 5-23 shows the Interrupt block diagram.
Figure 5-23. Interrupt Block Diagram
5.15.2 MASKABLE INTERRUPTS
All interrupts other than the Software Trap are maskable. Each maskable interrupt has an associated
enable bit and pending flag bit. The pending bit is set to 1 when the interrupt condition occurs. The state
of the interrupt enable bit, combined with the GIE bit determines whether an active pending flag actually
triggers an interrupt. All of the maskable interrupt pending and enable bits are contained in mapped
control registers, and thus can be controlled by the software.
A maskable interrupt condition triggers an interrupt under the following conditions:
1. The enable bit associated with that interrupt is set.
2. The GIE bit is set.
3. The device is not processing a non-maskable interrupt. (If a non-maskable interrupt is being serviced,
a maskable interrupt must wait until that service routine is completed.)
An interrupt is triggered only when all of these conditions are met at the beginning of an instruction. If
different maskable interrupts meet these conditions simultaneously, the highest-priority interrupt will be
serviced first, and the other pending interrupts must wait.
74 Functional Description Copyright © 2000–2013, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
www.ti.com
SNOS535I OCTOBER 2000REVISED MARCH 2013
Upon Reset, all pending bits, individual enable bits, and the GIE bit are reset to zero. Thus, a maskable
interrupt condition cannot trigger an interrupt until the program enables it by setting both the GIE bit and
the individual enable bit. When enabling an interrupt, the user should consider whether or not a previously
activated (set) pending bit should be acknowledged. If, at the time an interrupt is enabled, any previous
occurrences of the interrupt should be ignored, the associated pending bit must be reset to zero prior to
enabling the interrupt. Otherwise, the interrupt may be simply enabled; if the pending bit is already set, it
will immediately trigger an interrupt. A maskable interrupt is active if its associated enable and pending
bits are set.
An interrupt is an asychronous event which may occur before, during, or after an instruction cycle. Any
interrupt which occurs during the execution of an instruction is not acknowledged until the start of the next
normally executed instruction. If the next normally executed instruction is to be skipped, the skip is
performed before the pending interrupt is acknowledged.
At the start of interrupt acknowledgment, the following actions occur:
1. The GIE bit is automatically reset to zero, preventing any subsequent maskable interrupt from
interrupting the current service routine. This feature prevents one maskable interrupt from interrupting
another one being serviced.
2. The address of the instruction about to be executed is pushed onto the stack.
3. The program counter (PC) is loaded with 00FF Hex, causing a jump to that program memory location.
The device requires seven instruction cycles to perform the actions listed above.
If the user wishes to allow nested interrupts, the interrupts service routine may set the GIE bit to 1 by
writing to the PSW register, and thus allow other maskable interrupts to interrupt the current service
routine. If nested interrupts are allowed, caution must be exercised. The user must write the program in
such a way as to prevent stack overflow, loss of saved context information, and other unwanted
conditions.
The interrupt service routine stored at location 00FF Hex should use the VIS instruction to determine the
cause of the interrupt, and jump to the interrupt handling routine corresponding to the highest priority
enabled and active interrupt. Alternately, the user may choose to poll all interrupt pending and enable bits
to determine the source(s) of the interrupt. If more than one interrupt is active, the user's program must
decide which interrupt to service.
Within a specific interrupt service routine, the associated pending bit should be cleared. This is typically
done as early as possible in the service routine in order to avoid missing the next occurrence of the same
type of interrupt event. Thus, if the same event occurs a second time, even while the first occurrence is
still being serviced, the second occurrence will be serviced immediately upon return from the current
interrupt routine.
An interrupt service routine typically ends with an RETI instruction. This instruction set the GIE bit back to
1, pops the address stored on the stack, and restores that address to the program counter. Program
execution then proceeds with the next instruction that would have been executed had there been no
interrupt. If there are any valid interrupts pending, the highest-priority interrupt is serviced immediately
upon return from the previous interrupt.
NOTE
While executing from the Boot ROM for ISP or virtual E2 operations, the hardware will
disable interrupts from occurring. The hardware will leave the GIE bit in its current state, and
if set, the hardware interrupts will occur when execution is returned to Flash Memory.
Subsequent interrupts, during ISP operation, from the same interrupt source will be lost.
Copyright © 2000–2013, Texas Instruments Incorporated Functional Description 75
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
SNOS535I OCTOBER 2000REVISED MARCH 2013
www.ti.com
5.15.3 VIS INSTRUCTION
The general interrupt service routine, which starts at address 00FF Hex, must be capable of handling all
types of interrupts. The VIS instruction, together with an interrupt vector table, directs the device to the
specific interrupt handling routine based on the cause of the interrupt.
VIS is a single-byte instruction, typically used at the very beginning of the general interrupt service routine
at address 00FF Hex, or shortly after that point, just after the code used for context switching. The VIS
instruction determines which enabled and pending interrupt has the highest priority, and causes an indirect
jump to the address corresponding to that interrupt source. The jump addresses (vectors) for all possible
interrupts sources are stored in a vector table.
The vector table may be as long as 32 bytes (maximum of 16 vectors) and resides at the top of the 256-
byte block containing the VIS instruction. However, if the VIS instruction is at the very top of a 256-byte
block (such as at 00FF Hex), the vector table resides at the top of the next 256-byte block. Thus, if the
VIS instruction is located somewhere between 00FF and 01DF Hex (the usual case), the vector table is
located between addresses 01E0 and 01FF Hex. If the VIS instruction is located between 01FF and 02DF
Hex, then the vector table is located between addresses 02E0 and 02FF Hex, and so on.
Each vector is 15 bits long and points to the beginning of a specific interrupt service routine somewhere in
the 32-kbyte memory space. Each vector occupies two bytes of the vector table, with the higher-order byte
at the lower address. The vectors are arranged in order of interrupt priority. The vector of the maskable
interrupt with the lowest rank is located to 0yE0 (higher-order byte) and 0yE1 (lower-order byte). The next
priority interrupt is located at 0yE2 and 0yE3, and so forth in increasing rank. The Software Trap has the
highest rand and its vector is always located at 0yFE and 0yFF. The number of interrupts which can
become active defines the size of the table.
Table 5-27 shows the types of interrupts, the interrupt arbitration ranking, and the locations of the
corresponding vectors in the vector table.
The vector table should be filled by the user with the memory locations of the specific interrupt service
routines. For example, if the Software Trap routine is located at 0310 Hex, then the vector location 0yFE
and -0yFF should contain the data 03 and 10 Hex, respectively. When a Software Trap interrupt occurs
and the VIS instruction is executed, the program jumps to the address specified in the vector table.
The interrupt sources in the vector table are listed in order of rank, from highest to lowest priority. If two or
more enabled and pending interrupts are detected at the same time, the one with the highest priority is
serviced first. Upon return from the interrupt service routine, the next highest-level pending interrupt is
serviced.
If the VIS instruction is executed, but no interrupts are enabled and pending, the lowest-priority interrupt
vector is used, and a jump is made to the corresponding address in the vector table. This is an unusual
occurrence and may be the result of an error. It can legitimately result from a change in the enable bits or
pending flags prior to the execution of the VIS instruction, such as executing a single cycle instruction
which clears an enable flag at the same time that the pending flag is set. It can also result, however, from
inadvertent execution of the VIS command outside of the context of an interrupt.
The default VIS interrupt vector can be useful for applications in which time critical interrupts can occur
during the servicing of another interrupt. Rather than restoring the program context (A, B, X, etc.) and
executing the RETI instruction, an interrupt service routine can be terminated by returning to the VIS
instruction. In this case, interrupts will be serviced in turn until no further interrupts are pending and the
default VIS routine is started. After testing the GIE bit to ensure that execution is not erroneous, the
routine should restore the program context and execute the RETI to return to the interrupted program.
This technique can save up to fifty instruction cycles (tC), or more, (25 µs at 10 MHz oscillator) of latency
for pending interrupts with a penalty of fewer than ten instruction cycles if no further interrupts are
pending.
76 Functional Description Copyright © 2000–2013, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
www.ti.com
SNOS535I OCTOBER 2000REVISED MARCH 2013
To ensure reliable operation, the user should always use the VIS instruction to determine the source of an
interrupt. Although it is possible to poll the pending bits to detect the source of an interrupt, this practice is
not recommended. The use of polling allows the standard arbitration ranking to be altered, but the
reliability of the interrupt system is compromised. The polling routine must individually test the enable and
pending bits of each maskable interrupt. If a Software Trap interrupt should occur, it will be serviced last,
even though it should have the highest priority. Under certain conditions, a Software Trap could be
triggered but not serviced, resulting in an inadvertent “locking out” of all maskable interrupts by the
Software Trap pending flag. Problems such as this can be avoided by using VIS instruction.
Table 5-25. Interrupt Vector Table
Arbitration Vector Address(1)
Source Description
Ranking (Hi-Low Byte)
(1) Highest Software INTR Instruction 0yFE–0yFF
(2) Reserved for NMI 0yFC–0yFD
(3) External G0 0yFA–0yFB
(4) Timer T0 Underflow 0yF8–0yF9
(5) Timer T1 T1A/Underflow 0yF6–0yF7
(6) Timer T1 T1B 0yF4–0yF5
(7) MICROWIRE/PLUS BUSY Low 0yF2–0yF3
(8) Reserved 0yF0–0yF1
(9) USART Receive 0yEE–0yEF
(10) USART Transmit 0yEC–0yED
(11) Timer T2 T2A/Underflow 0yEA–0yEB
(12) Timer T2 T2B 0yE8–0yE9
(13) Timer T3 T3A/Underflow 0yE6–0yE7
(14) Timer T3 T3B 0yE4–0yE5
(15) Port L/Wake-up Port L Edge 0yE2–0yE3
(16) Lowest Default VIS Reserved 0yE0–0yE1
(1) y is a variable which represents the VIS block. VIS and the vector table must be located in the same
256-byte block except if VIS is located at the last address of a block. In this case, the table must be in
the next block.
5.15.3.1 VIS Execution
When the VIS instruction is executed it activates the arbitration logic. The arbitration logic generates an
even number between E0 and FE (E0, E2, E4, E6 etc....) depending on which active interrupt has the
highest arbitration ranking at the time of the 1st cycle of VIS is executed. For example, if the software trap
interrupt is active, FE is generated. If the external interrupt is active and the software trap interrupt is not,
then FA is generated and so forth. If no active interrupt is pending, than E0 is generated. This number
replaces the lower byte of the PC. The upper byte of the PC remains unchanged. The new PC is therefore
pointing to the vector of the active interrupt with the highest arbitration ranking. This vector is read from
program memory and placed into the PC which is now pointed to the 1st instruction of the service routine
of the active interrupt with the highest arbitration ranking.
Figure 5-24 illustrates the different steps performed by the VIS instruction. Figure 5-25 shows a flowchart
for the VIS instruction.
The non-maskable interrupt pending flag is cleared by the RPND (Reset Non-Maskable Pending Bit)
instruction (under certain conditions) and upon RESET.
Copyright © 2000–2013, Texas Instruments Incorporated Functional Description 77
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
SNOS535I OCTOBER 2000REVISED MARCH 2013
www.ti.com
Figure 5-24. VIS Operation
5.15.4 NON-MASKABLE INTERRUPT
5.15.4.1 Pending Flag
There is a pending flag bit associated with the non-maskable Software Trap interrupt, called STPND. This
pending flag is not memory-mapped and cannot be accessed directly by the software.
The pending flag is reset to zero when a device Reset occurs. When the non-maskable interrupt occurs,
the associated pending bit is set to 1. The interrupt service routine should contain an RPND instruction to
reset the pending flag to zero. The RPND instruction always resets the STPND flag.
5.15.4.2 Software Trap
The Software Trap is a special kind of non-maskable interrupt which occurs when the INTR instruction
(used to acknowledge interrupts) is fetched from program memory and placed in the instruction register.
This can happen in a variety of ways, usually because of an error condition. Some examples of causes
are listed below.
If the program counter incorrectly points to a memory location beyond the programmed Flash memory
space, the unused memory location returns zeros which is interpreted as the INTR instruction.
If the stack is popped beyond the allowed limit (address 06F Hex), a 7FFF will be loaded into the PC.
Since the Option Register resides at this location, and to maintain the integrity of the stack overpop
protection, the Flash memory will return a zero on an instruction fetch and a software trap will be
triggered.
A Software Trap can be triggered by a temporary hardware condition such as a brownout or power supply
glitch.
The Software Trap has the highest priority of all interrupts. When a Software Trap occurs, the STPND bit
is set. The GIE bit is not affected and the pending bit (not accessible by the user) is used to inhibit other
interrupts and to direct the program to the ST service routine with the VIS instruction. Nothing can interrupt
a Software Trap service routine except for another Software Trap. The STPND can be reset only by the
RPND instruction or a chip Reset.
78 Functional Description Copyright © 2000–2013, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
www.ti.com
SNOS535I OCTOBER 2000REVISED MARCH 2013
The Software Trap indicates an unusual or unknown error condition. Generally, returning to normal
execution at the point where the Software Trap occurred cannot be done reliably. Therefore, the Software
Trap service routine should re-initialize the stack pointer and perform a recovery procedure that re-starts
the software at some known point, similar to a device Reset, but not necessarily performing all the same
functions as a device Reset. The routine must also execute the RPND instruction to reset the STPND flag.
Otherwise, all other interrupts will be locked out. To the extent possible, the interrupt routine should record
or indicate the context of the device so that the cause of the Software Trap can be determined.
If the user wishes to return to normal execution from the point at which the Software Trap was triggered,
the user must first execute RPND, followed by RETSK rather than RETI or RET. This is because the
return address stored on the stack is the address of the INTR instruction that triggered the interrupt. The
program must skip that instruction in order to proceed with the next one. Otherwise, an infinite loop of
Software Traps and returns will occur.
Programming a return to normal execution requires careful consideration. If the Software Trap routine is
interrupted by another Software Trap, the RPND instruction in the service routine for the second Software
Trap will reset the STPND flag; upon return to the first Software Trap routine, the STPND flag will have the
wrong state. This will allow maskable interrupts to be acknowledged during the servicing of the first
Software Trap. To avoid problems such as this, the user program should contain the Software Trap
routine to perform a recovery procedure rather than a return to normal execution.
Under normal conditions, the STPND flag is reset by a RPND instruction in the Software Trap service
routine. If a programming error or hardware condition (brownout, power supply glitch, etc.) sets the
STPND flag without providing a way for it to be cleared, all other interrupts will be locked out. To alleviate
this condition, the user can use extra RPND instructions in the main program and in the Watchdog service
routine (if present). There is no harm in executing extra RPND instructions in these parts of the program.
Figure 5-25. VIS Flow Chart
Copyright © 2000–2013, Texas Instruments Incorporated Functional Description 79
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
SNOS535I OCTOBER 2000REVISED MARCH 2013
www.ti.com
5.15.4.2.1 Programming Example: External Interrupt
PSW =00EF
CNTRL =00EE
RBIT 0,PORTGC
RBIT 0,PORTGD ; G0 pin configured Hi-Z
SBIT IEDG, CNTRL ; Ext interrupt polarity; falling edge
SBIT GIE, PSW ; Set the GIE bit
SBIT EXEN, PSW ; Enable the external interrupt
WAIT: JP WAIT ; Wait for external interrupt
.
.
.
.=0FF ; The interrupt causes a
VIS ; branch to address 0FF
; The VIS causes a branch to
; interrupt vector table
.
.
.
.=01FA ; Vector table (within 256 byte
.ADDRW SERVICE ; of VIS inst.) containing the ext
; interrupt service routine
.
.
.
SERVICE: ; Interrupt Service Routine
RBIT,EXPND,PSW ; Reset ext interrupt pend. bit
.
.
.
RET I ; Return, set the GIE bit
5.15.5 PORT L INTERRUPTS
Port L provides the user with an additional eight fully selectable, edge sensitive interrupts which are all
vectored into the same service subroutine.
The interrupt from Port L shares logic with the wake-up circuitry. The register WKEN allows interrupts from
Port L to be individually enabled or disabled. The register WKEDG specifies the trigger condition to be
either a positive or a negative edge. Finally, the register WKPND latches in the pending trigger conditions.
The GIE (Global Interrupt Enable) bit enables the interrupt function.
A control flag, LPEN, functions as a global interrupt enable for Port L interrupts. Setting the LPEN flag will
enable interrupts and vice versa. A separate global pending flag is not needed since the register WKPND
is adequate.
Since Port L is also used for waking the device out of the HALT or IDLE modes, the user can elect to exit
the HALT or IDLE modes either with or without the interrupt enabled. If he elects to disable the interrupt,
then the device will restart execution from the instruction immediately following the instruction that placed
the microcontroller in the HALT or IDLE modes. In the other case, the device will first execute the interrupt
service routine and then revert to normal operation. (See HALT MODE for clock option wake-up
information.)
5.15.6 INTERRUPT SUMMARY
The device uses the following types of interrupts, listed below in order of priority:
1. The Software Trap non-maskable interrupt, triggered by the INTR (00 opcode) instruction. The
Software Trap is acknowledged immediately. This interrupt service routine can be interrupted only by
another Software Trap. The Software Trap should end with two RPND instructions followed by a re-
start procedure.
2. Maskable interrupts, triggered by an on-chip peripheral block or an external device connected to the
device. Under ordinary conditions, a maskable interrupt will not interrupt any other interrupt routine in
progress. A maskable interrupt routine in progress can be interrupted by the non-maskable interrupt
request. A maskable interrupt routine should end with an RETI instruction or, prior to restoring context,
80 Functional Description Copyright © 2000–2013, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
www.ti.com
SNOS535I OCTOBER 2000REVISED MARCH 2013
should return to execute the VIS instruction. This is particularly useful when exiting long interrupt
service routines if the time between interrupts is short. In this case the RETI instruction would only be
executed when the default VIS routine is reached.
3. While executing from the Boot ROM for ISP or virtual E2 operations, the hardware will disable
interrupts from occurring. The hardware will leave the GIE bit in its current state, and if set, the
hardware interrupts will occur when execution is returned to Flash Memory. Subsequent interrupts,
during ISP operation, from the same interrupt source will be lost.
5.16 WATCHDOG/Clock Monitor
The devices contain a user selectable WATCHDOG and clock monitor. The following section is applicable
only if the WATCHDOG feature has been selected in the Option register. The WATCHDOG is designed to
detect the user program getting stuck in infinite loops resulting in loss of program control or “runaway”
programs.
The WATCHDOG logic contains two separate service windows. While the user programmable upper
window selects the WATCHDOG service time, the lower window provides protection against an infinite
program loop that contains the WATCHDOG service instruction. The WATCHDOG uses the Idle Timer
(T0) and thus all times are measured in Idle Timer Clocks.
The Clock Monitor is used to detect the absence of a clock or a very slow clock below a specified rate on
tC.
The WATCHDOG consists of two independent logic blocks: WD UPPER and WD LOWER. WD UPPER
establishes the upper limit on the service window and WD LOWER defines the lower limit of the service
window.
Servicing the WATCHDOG consists of writing a specific value to a WATCHDOG Service Register named
WDSVR which is memory mapped in the RAM. This value is composed of three fields, consisting of a 2-
bit Window Select, a 5-bit Key Data field, and the 1-bit Clock Monitor Select field. Table 5-26 shows the
WDSVR register.
Table 5-26. WATCHDOG Service Register (WDSVR)
Window Select Key Data Clock Monitor
X X 0 1 1 0 0 Y
7 6 5 4 3 2 1 0
The lower limit of the service window is fixed at 2048 Idle Timer Clocks. Bits 7 and 6 of the WDSVR
register allow the user to pick an upper limit of the service window.
Table 5-27 shows the four possible combinations of lower and upper limits for the WATCHDOG service
window. This flexibility in choosing the WATCHDOG service window prevents any undue burden on the
user software.
Bits 5, 4, 3, 2 and 1 of the WDSVR register represent the 5-bit Key Data field. The key data is fixed at
01100. Bit 0 of the WDSVR Register is the Clock Monitor Select bit.
Table 5-27. WATCHDOG Service Window Select
Clock Service Window Service Window
WDSVR WDSVR Monitor for High Speed Mode for Dual Clock & Low Speed Modes
Bit 7 Bit 6 Bit 0 (Lower-Upper Limits) (Lower-Upper Limits)
0 0 X 2048-8k tCCycles 2048-8k Cycles of 32 kHz Clk
0 1 X 2048-16k tCCycles 2048-16k Cycles of LS 32 kHz Clk
1 0 X 2048-32k tCCycles 2048-32k Cycles of LS 32 kHz Clk
1 1 X 2048-64k tCCycles 2048-64k Cycles of LS 32 kHz Clk
X X 0 Clock Monitor Disabled Clock Monitor Disabled
Copyright © 2000–2013, Texas Instruments Incorporated Functional Description 81
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
SNOS535I OCTOBER 2000REVISED MARCH 2013
www.ti.com
Table 5-27. WATCHDOG Service Window Select (continued)
Clock Service Window Service Window
WDSVR WDSVR Monitor for High Speed Mode for Dual Clock & Low Speed Modes
Bit 7 Bit 6 Bit 0 (Lower-Upper Limits) (Lower-Upper Limits)
X X 1 Clock Monitor Enabled Clock Monitor Enabled
5.16.1 CLOCK MONITOR
The Clock Monitor aboard the device can be selected or deselected under program control. The Clock
Monitor is ensured not to reject the clock if the instruction cycle clock (1/tC) is greater or equal to 5 kHz.
This equates to a clock input rate on the selected oscillator of greater or equal to 25 kHz.
5.16.2 WATCHDOG/CLOCK MONITOR OPERATION
The WATCHDOG is enabled by bit 2 of the Option register. When this Option bit is 0, the WATCHDOG is
enabled and pin G1 becomes the WATCHDOG output with a weak pull-up.
The WATCHDOG and Clock Monitor are disabled during reset. The device comes out of reset with the
WATCHDOG armed, the WATCHDOG Window Select bits (bits 6, 7 of the WDSVR Register) set, and the
Clock Monitor bit (bit 0 of the WDSVR Register) enabled. Thus, a Clock Monitor error will occur after
coming out of reset, if the instruction cycle clock frequency has not reached a minimum specified value,
including the case where the oscillator fails to start.
The WDSVR register can be written to only once after reset and the key data (bits 5 through 1 of the
WDSVR Register) must match to be a valid write. This write to the WDSVR register involves two
irrevocable choices: (i) the selection of the WATCHDOG service window (ii) enabling or disabling of the
Clock Monitor. Hence, the first write to WDSVR Register involves selecting or deselecting the Clock
Monitor, select the WATCHDOG service window and match the WATCHDOG key data. Subsequent
writes to the WDSVR register will compare the value being written by the user to the WATCHDOG service
window value, the key data and the Clock Monitor Enable (all bits) in the WDSVR Register. Table 5-28
shows the sequence of events that can occur.
The user must service the WATCHDOG at least once before the upper limit of the service window expires.
The WATCHDOG may not be serviced more than once in every lower limit of the service window.
When jumping to the boot ROM for ISP and virtual E2 operations, the hardware will disable the lower
window error and perform an immediate WATCHDOG service. The ISP routines will service the
WATCHDOG within the selected upper window. The ISP routines will service the WATCHDOG
immediately prior to returning execution back to the user's code in flash. Therefore, after returning to flash
memory, the user can service the WATCHDOG anytime following the return from boot ROM, but must
service it within the selected upper window to avoid a WATCHDOG error.
The WATCHDOG has an output pin associated with it. This is the WDOUT pin, on pin 1 of the port G.
WDOUT is active low. The WDOUT pin has a weak pull-up in the inactive state. Upon triggering the
WATCHDOG, the logic will pull the WDOUT (G1) pin low for an additional 16–32 cycles after the signal
level on WDOUT pin goes below the lower Schmitt trigger threshold. After this delay, the device will stop
forcing the WDOUT output low. The WATCHDOG service window will restart when the WDOUT pin goes
high.
A WATCHDOG service while the WDOUT signal is active will be ignored. The state of the WDOUT pin is
not ensured on reset, but if it powers up low then the WATCHDOG will time out and WDOUT will go high.
The Clock Monitor forces the G1 pin low upon detecting a clock frequency error. The Clock Monitor error
will continue until the clock frequency has reached the minimum specified value, after which the G1 output
will go high following 16–32 clock cycles. The Clock Monitor generates a continual Clock Monitor error if
the oscillator fails to start, or fails to reach the minimum specified frequency. The specification for the
Clock Monitor is as follows:
1/tC> 5 kHz—No clock rejection.
82 Functional Description Copyright © 2000–2013, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
www.ti.com
SNOS535I OCTOBER 2000REVISED MARCH 2013
1/tC< 10 Hz—Ensured clock rejection.
Table 5-28. WATCHDOG Service Actions
Key Window Clock Action
Data Data Monitor
Match Match Match Valid Service: Restart Service Window
Don't Care Mismatch Don't Care Error: Generate WATCHDOG Output
Mismatch Don't Care Don't Care Error: Generate WATCHDOG Output
Don't Care Don't Care Mismatch Error: Generate WATCHDOG Output
5.16.3 WATCHDOG AND CLOCK MONITOR SUMMARY
The following salient points regarding the WATCHDOG and CLOCK MONITOR should be noted:
Both the WATCHDOG and CLOCK MONITOR detector circuits are inhibited during RESET.
Following RESET, the WATCHDOG and CLOCK MONITOR are both enabled, with the WATCHDOG
having the maximum service window selected.
The WATCHDOG service window and CLOCK MONITOR enable/disable option can only be changed
once, during the initial WATCHDOG service following RESET.
The initial WATCHDOG service must match the key data value in the WATCHDOG Service register
WDSVR in order to avoid a WATCHDOG error.
Subsequent WATCHDOG services must match all three data fields in WDSVR in order to avoid
WATCHDOG errors.
The correct key data value cannot be read from the WATCHDOG Service register WDSVR. Any
attempt to read this key data value of 01100 from WDSVR will read as key data value of all 0's.
The WATCHDOG detector circuit is inhibited during both the HALT and IDLE modes.
The CLOCK MONITOR detector circuit is active during both the HALT and IDLE modes. Consequently,
the device inadvertently entering the HALT mode will be detected as a CLOCK MONITOR error
(provided that the CLOCK MONITOR enable option has been selected by the program). Likewise, a
device with WATCHDOG enabled in the Option but with the WATCHDOG output not connected to
RESET, will draw excessive HALT current if placed in the HALT mode. The clock Monitor will pull the
WATCHDOG output low and sink current through the on-chip pull-up resistor.
The WATCHDOG service window will be set to its selected value from WDSVR following HALT.
Consequently, the WATCHDOG should not be serviced for at least 2048 Idle Timer clocks following
HALT, but must be serviced within the selected window to avoid a WATCHDOG error.
The IDLE timer T0 is not initialized with external RESET.
The user can sync in to the IDLE counter cycle with an IDLE counter (T0) interrupt or by monitoring the
T0PND flag. The T0PND flag is set whenever the selected bit of the IDLE counter toggles (every 4, 8,
16, 32 or 64k Idle Timer clocks). The user is responsible for resetting the T0PND flag.
A hardware WATCHDOG service occurs just as the device exits the IDLE mode. Consequently, the
WATCHDOG should not be serviced for at least 2048 Idle Timer clocks following IDLE, but must be
serviced within the selected window to avoid a WATCHDOG error.
Following RESET, the initial WATCHDOG service (where the service window and the CLOCK
MONITOR enable/disable must be selected) may be programmed anywhere within the maximum
service window (65,536 instruction cycles) initialized by RESET. Note that this initial WATCHDOG
service may be programmed within the initial 2048 instruction cycles without causing a WATCHDOG
error.
When using any of the ISP functions in Boot ROM, the ISP routines will service the WATCHDOG
within the selected upper window. Upon return to flash memory, the WATCHDOG is serviced, the
lower window is enabled, and the user can service the WATCHDOG anytime following exit from Boot
ROM, but must service it within the selected upper window to avoid a WATCHDOG error.
Copyright © 2000–2013, Texas Instruments Incorporated Functional Description 83
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
SNOS535I OCTOBER 2000REVISED MARCH 2013
www.ti.com
5.16.4 DETECTION OF ILLEGAL CONDITIONS
The device can detect various illegal conditions resulting from coding errors, transient noise, power supply
voltage drops, runaway programs, etc.
Reading of unprogrammed ROM gets zeros. The opcode for software interrupt is 00. If the program
fetches instructions from unprogrammed ROM, this will force a software interrupt, thus signaling that an
illegal condition has occurred.
The subroutine stack grows down for each call (jump to subroutine), interrupt, or PUSH, and grows up for
each return or POP. The stack pointer is initialized to RAM location 06F Hex during reset. Consequently, if
there are more returns than calls, the stack pointer will point to addresses 070 and 071 Hex (which are
undefined RAM). Undefined RAM from addresses 070 to 07F (Segment 0), and all other segments (i.e.,
Segments 4... etc.) is read as all 1's, which in turn will cause the program to return to address 7FFF Hex.
The Option Register is located at this location and, when accessed by an instruction fetch, will respond
with an INTR instruction (all 0's) to generate a software interrupt, signalling an illegal condition on overpop
of the stack.
Thus, the chip can detect the following illegal conditions:
1. Executing from undefined Program Memory
2. Over “POP”ing the stack by having more returns than calls.
When the software interrupt occurs, the user can re-initialize the stack pointer and do a recovery
procedure before restarting (this recovery program is probably similar to that following reset, but might not
contain the same program initialization procedures). The recovery program should reset the software
interrupt pending bit using the RPND instruction.
5.17 MICROWIRE/PLUS
MICROWIRE/PLUS is a serial SPI compatible synchronous communications interface. The
MICROWIRE/PLUS capability enables the device to interface with MICROWIRE/PLUS or SPI peripherals
(i.e. A/D converters, display drivers, EEPROMs etc.) and with other microcontrollers which support the
MICROWIRE/PLUS or SPI interface. It consists of an 8-bit serial shift register (SIO) with serial data input
(SI), serial data output (SO) and serial shift clock (SK). Figure 5-26 shows a block diagram of the
MICROWIRE/PLUS logic.
The shift clock can be selected from either an internal source or an external source. Operating the
MICROWIRE/PLUS arrangement with the internal clock source is called the Master mode of operation.
Similarly, operating the MICROWIRE/PLUS arrangement with an external shift clock is called the Slave
mode of operation.
The CNTRL register is used to configure and control the MICROWIRE/PLUS mode. To use the
MICROWIRE/PLUS, the MSEL bit in the CNTRL register is set to one. In the master mode, the SK clock
rate is selected by the two bits, SL0 and SL1, in the CNTRL register. Table 5-29 details the different clock
rates that may be selected.
Table 5-29. MICROWIRE/PLUS
Master Mode Clock Select
SL1 SL0 SK Period(1)
0 0 2 × tC
0 1 4 × tC
1 x 8 × tC
(1) Where tCis the instruction cycle clock
84 Functional Description Copyright © 2000–2013, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
www.ti.com
SNOS535I OCTOBER 2000REVISED MARCH 2013
5.17.1 MICROWIRE/PLUS OPERATION
Setting the BUSY bit in the PSW register causes the MICROWIRE/PLUS to start shifting the data. It gets
reset when eight data bits have been shifted. The user may reset the BUSY bit by software to allow less
than 8 bits to shift. If enabled, an interrupt is generated when eight data bits have been shifted. The device
may enter the MICROWIRE/PLUS mode either as a Master or as a Slave. Figure 5-26 shows how two
microcontroller devices and several peripherals may be interconnected using the MICROWIRE/PLUS
arrangements.
WARNING
The SIO register should only be loaded when the SK clock is in the idle phase.
Loading the SIO register while the SK clock is in the active phase, will result in
undefined data in the SIO register.
Setting the BUSY flag when the input SK clock is in the active phase while in the
MICROWIRE/PLUS is in the slave mode may cause the current SK clock for the
SIO shift register to be narrow. For safety, the BUSY flag should only be set when
the input SK clock is in the idle phase.
5.17.1.1 MICROWIRE/PLUS Master Mode Operation
In the MICROWIRE/PLUS Master mode of operation the shift clock (SK) is generated internally. The
MICROWIRE/PLUS Master always initiates all data exchanges. The MSEL bit in the CNTRL register must
be set to enable the SO and SK functions onto the G Port. The SO and SK pins must also be selected as
outputs by setting appropriate bits in the Port G configuration register. In the slave mode, the shift clock
stops after 8 clock pulses. Table 5-30 summarizes the bit settings required for Master mode of operation.
5.17.1.2 MICROWIRE/PLUS Slave Mode Operation
In the MICROWIRE/PLUS Slave mode of operation the SK clock is generated by an external source.
Setting the MSEL bit in the CNTRL register enables the SO and SK functions onto the G Port. The SK pin
must be selected as an input and the SO pin is selected as an output pin by setting and resetting the
appropriate bits in the Port G configuration register. Table 5-30 summarizes the settings required to enter
the Slave mode of operation.
Table 5-30. MICROWIRE/PLUS Mode Settings
G4 (SO) G5 (SK) G4 G5 Operation
Config. Bit Config. Bit Fun. Fun.
1 1 SO Int. MICROWIRE/PLUS
SK Master
0 1 TRI- Int. MICROWIRE/PLUS
STATE SK Master
1 0 SO Ext. MICROWIRE/PLUS
SK Slave
0 0 TRI- Ext. MICROWIRE/PLUS
STATE SK Slave
Copyright © 2000–2013, Texas Instruments Incorporated Functional Description 85
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
SNOS535I OCTOBER 2000REVISED MARCH 2013
www.ti.com
The user must set the BUSY flag immediately upon entering the Slave mode. This ensures that all data
bits sent by the Master is shifted properly. After eight clock pulses the BUSY flag is clear, the shift clock is
stopped, and the sequence may be repeated.
Figure 5-26. MICROWIRE/PLUS Application
5.17.1.2.1 Alternate SK Phase Operation and SK Idle Polarity
The device allows either the normal SK clock or an alternate phase SK clock to shift data in and out of the
SIO register. In both the modes the SK idle polarity can be either high or low. The polarity is selected by
bit 5 of Port G data register. In the normal mode data is shifted in on the rising edge of the SK clock and
the data is shifted out on the falling edge of the SK clock. The SIO register is shifted on each falling edge
of the SK clock. In the alternate SK phase operation, data is shifted in on the falling edge of the SK clock
and shifted out on the rising edge of the SK clock. Bit 6 of Port G configuration register selects the SK
edge.
A control flag, SKSEL, allows either the normal SK clock or the alternate SK clock to be selected. Refer to
Table 5-31 for the appropriate setting of the SKSEL bit. The SKSEL is mapped into the G6 configuration
bit. The SKSEL flag will power up in the reset condition, selecting the normal SK signal provided the SK
Idle Polarity remains LOW.
Table 5-31. MICROWIRE/PLUS Shift Clock Polarity and Sample/Shift Phase
Port G
SK Phase SO Clocked Out On: SI Sampled On: SK Idle Phase
G6 (SKSEL) G5 Data Bit
Config. Bit
Normal 0 0 SK Falling Edge SK Rising Edge Low
Alternate 1 0 SK Rising Edge SK Falling Edge Low
Alternate 0 1 SK Rising Edge SK Falling Edge High
Normal 1 1 SK Falling Edge SK Rising Edge High
86 Functional Description Copyright © 2000–2013, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
www.ti.com
SNOS535I OCTOBER 2000REVISED MARCH 2013
Figure 5-27. MICROWIRE/PLUS SPI Mode Interface Timing, Normal SK Mode, SK Idle Phase being Low
Figure 5-28. MICROWIRE/PLUS SPI Mode Interface Timing, Alternate SK Mode, SK Idle Phase being Low
Figure 5-29. MICROWIRE/PLUS SPI Mode Interface Timing, Normal SK Mode, SK Idle Phase being High
Figure 5-30. MICROWIRE/PLUS SPI Mode Interface Timing, Alternate SK Mode, SK Idle Phase being High
Copyright © 2000–2013, Texas Instruments Incorporated Functional Description 87
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
SNOS535I OCTOBER 2000REVISED MARCH 2013
www.ti.com
5.18 Memory Map
All RAM, ports and registers (except A and PC) are mapped into data memory address space.
Address Contents(1)
S/ADD REG
0000 to 006F On-Chip RAM bytes (112 bytes)
0070 to 007F Unused RAM Address Space (Reads As All Ones)
xx80 to xx90 Unused RAM Address Space (Reads Undefined Data)
xx90 Port E Data Register
xx91 Port E Configuration Register
xx92 Port E Input Pins (Read Only)
xx93 Reserved for Port E
xx94 Port F Data Register
xx95 Port F Configuration Register
xx96 Port F Input Pins (Read Only)
xx97 Reserved for Port F
xx98 to xx9F Reserved
xxA0 Port A Data Register
xxA1 Port A Configuration Register
xxA2 Port A Input Pins (Read Only)
xxA3 Reserved for Port A
xxA4 Port B Data Register
xxA5 Port B Configuration Register
xxA6 Port B Input Pins (Read Only)
xxA7 Reserved for Port B
xxA8 ISP Address Register Low Byte (ISPADLO)
xxA9 ISP Address Register High Byte (ISPADHI)
xxAA ISP Read Data Register (ISPRD)
xxAB ISP Write Data Register (ISPWR)
xxAC Reserved
xxAD Reserved
xxAE Reserved
xxAF High Speed Timers Control Register (HSTCR)
xxB0 Timer T3 Lower Byte
xxB1 Timer T3 Upper Byte
xxB2 Timer T3 Autoload Register T3RA Lower Byte
xxB3 Timer T3 Autoload Register T3RA Upper Byte
xxB4 Timer T3 Autoload Register T3RB Lower Byte
xxB5 Timer T3 Autoload Register T3RB Upper Byte
xxB6 Timer T3 Control Register
xxB7 Reserved
xxB8 USART Transmit Buffer (TBUF)
xxB9 USART Receive Buffer (RBUF)
xxBA USART Control and Status Register (ENU)
xxBB USART Receive Control and Status Register (ENUR)
xxBC USART Interrupt and Clock Source Register (ENUI)
xxBD USART Baud Register (BAUD)
xxBE USART Prescale Select Register (PSR)
(1) Reading memory locations 0070H–007FH (Segment 0) will return all ones. Reading unused memory
locations 0080H–0093H (Segment 0) will return undefined data. Reading memory locations from other
Segments (i.e., Segment 8, Segment 9, etc.) will return undefined data.
88 Functional Description Copyright © 2000–2013, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
www.ti.com
SNOS535I OCTOBER 2000REVISED MARCH 2013
Address Contents(1)
S/ADD REG
xxBF Reserved for USART
xxC0 Timer T2 Lower Byte
xxC1 Timer T2 Upper Byte
xxC2 Timer T2 Autoload Register T2RA Lower Byte
xxC3 Timer T2 Autoload Register T2RA Upper Byte
xxC4 Timer T2 Autoload Register T2RB Lower Byte
xxC5 Timer T2 Autoload Register T2RB Upper Byte
xxC6 Timer T2 Control Register
xxC7 WATCHDOG Service Register (Reg:WDSVR)
xxC8 MIWU Edge Select Register (Reg:WKEDG)
xxC9 MIWU Enable Register (Reg:WKEN)
xxCA MIWU Pending Register (Reg:WKPND)
xxCB A/D Converter Control Register (ENAD)
xxCC A/D Converter Result Register High Byte (ADRSTH)
xxCD A/D Converter Result Register Low Byte (ADRSTL)
xxCE Reserved
xxCF Idle Timer Control Register (ITMR)
xxD0 Port L Data Register
xxD1 Port L Configuration Register
xxD2 Port L Input Pins (Read Only)
xxD3 Reserved for Port L
xxD4 Port G Data Register
xxD5 Port G Configuration Register
xxD6 Port G Input Pins (Read Only)
xxD7 Reserved
xxD8 Port C Data Register
xxD9 Port C Configuration Register
xxDA Port C Input Pins (Read Only)
xxDB Reserved for Port C
xxDC Port D
xxDD to xxDF Reserved for Port D
xxE0 Reserved
xxE1 Flash Memory Write Timing Register (PGMTIM)
xxE2 ISP Key Register (ISPKEY)
xxE3 to xxE5 Reserved
xxE6 Timer T1 Autoload Register T1RB Lower Byte
xxE7 Timer T1 Autoload Register T1RB Upper Byte
xxE8 ICNTRL Register
xxE9 MICROWIRE/PLUS Shift Register
xxEA Timer T1 Lower Byte
xxEB Timer T1 Upper Byte
xxEC Timer T1 Autoload Register T1RA Lower Byte
xxED Timer T1 Autoload Register T1RA Upper Byte
xxEE CNTRL Control Register
xxEF PSW Register
xxF0 to FB On-Chip RAM Mapped as Registers
xxFC X Register
xxFD SP Register
Copyright © 2000–2013, Texas Instruments Incorporated Functional Description 89
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
SNOS535I OCTOBER 2000REVISED MARCH 2013
www.ti.com
Address Contents(1)
S/ADD REG
xxFE B Register
xxFF S Register
0100 to 017F On-Chip 128 RAM Bytes
0200 to 027F On-Chip 128 RAM Bytes
0300 to 037F On-Chip 128 RAM Bytes
0400 to 0047F On-Chip 128 RAM Bytes
0500 to 057F On-Chip 128 RAM Bytes
0600 to 067F On-Chip 128 RAM Bytes
0700 to 077F On-Chip 128 RAM Bytes
5.19 Instruction Set
5.19.1 INTRODUCTION
This section defines the instruction set of the COP8 Family members. It contains information about the
instruction set features, addressing modes and types.
5.19.2 INSTRUCTION FEATURES
The strength of the instruction set is based on the following features:
Mostly single-byte opcode instructions minimize program size.
One instruction cycle for the majority of single-byte instructions to minimize program execution time.
Many single-byte, multiple function instructions such as DRSZ.
Three memory mapped pointers: two for register indirect addressing, and one for the software stack.
Sixteen memory mapped registers that allow an optimized implementation of certain instructions.
Ability to set, reset, and test any individual bit in data memory address space, including the memory-
mapped I/O ports and registers.
Register-Indirect LOAD and EXCHANGE instructions with optional automatic post-incrementing or
decrementing of the register pointer. This allows for greater efficiency (both in cycle time and program
code) in loading, walking across and processing fields in data memory.
Unique instructions to optimize program size and throughput efficiency. Some of these instructions are:
DRSZ, IFBNE, DCOR, RETSK, VIS and RRC.
5.19.3 ADDRESSING MODES
The instruction set offers a variety of methods for specifying memory addresses. Each method is called an
addressing mode. These modes are classified into two categories: operand addressing modes and
transfer-of-control addressing modes. Operand addressing modes are the various methods of specifying
an address for accessing (reading or writing) data. Transfer-of-control addressing modes are used in
conjunction with jump instructions to control the execution sequence of the software program.
5.19.3.1 Operand Addressing Modes
The operand of an instruction specifies what memory location is to be affected by that instruction. Several
different operand addressing modes are available, allowing memory locations to be specified in a variety
of ways. An instruction can specify an address directly by supplying the specific address, or indirectly by
specifying a register pointer. The contents of the register (or in some cases, two registers) point to the
desired memory location. In the immediate mode, the data byte to be used is contained in the instruction
itself.
Each addressing mode has its own advantages and disadvantages with respect to flexibility, execution
speed, and program compactness. Not all modes are available with all instructions. The Load (LD)
instruction offers the largest number of addressing modes.
90 Functional Description Copyright © 2000–2013, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
www.ti.com
SNOS535I OCTOBER 2000REVISED MARCH 2013
The available addressing modes are:
Direct
Register B or X Indirect
Register B or X Indirect with Post-Incrementing/Decrementing
Immediate
Immediate Short
Indirect from Program Memory
The addressing modes are described below. Each description includes an example of an assembly
language instruction using the described addressing mode.
Direct. The memory address is specified directly as a byte in the instruction. In assembly language, the
direct address is written as a numerical value (or a label that has been defined elsewhere in the program
as a numerical value).
Example: Load Accumulator Memory Direct
LD A,05
Reg/Data Contents Contents
Memory Before After
Accumulator XX Hex A6 Hex
Memory Location A6 Hex A6 Hex
0005 Hex
Register B or X Indirect. The memory address is specified by the contents of the B Register or X register
(pointer register). In assembly language, the notation [B] or [X] specifies which register serves as the
pointer.
Example: Exchange Memory with Accumulator, B Indirect
X A,[B]
Reg/Data Contents Contents
Memory Before After
Accumulator 01 Hex 87 Hex
Memory Location 87 Hex 01 Hex
0005 Hex
B Pointer 05 Hex 05 Hex
Register B or X Indirect with Post-Incrementing/Decrementing. The relevant memory address is
specified by the contents of the B Register or X register (pointer register). The pointer register is
automatically incremented or decremented after execution, allowing easy manipulation of memory blocks
with software loops. In assembly language, the notation [B+], [B], [X+], or [X] specifies which register
serves as the pointer, and whether the pointer is to be incremented or decremented.
Example: Exchange Memory with Accumulator, B Indirect with Post-Increment
X A,[B+]
Reg/Data Contents Contents
Memory Before After
Accumulator 03 Hex 62 Hex
Copyright © 2000–2013, Texas Instruments Incorporated Functional Description 91
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
SNOS535I OCTOBER 2000REVISED MARCH 2013
www.ti.com
Reg/Data Contents Contents
Memory Before After
Memory Location 62 Hex 03 Hex
0005 Hex
B Pointer 05 Hex 06 Hex
Intermediate. The data for the operation follows the instruction opcode in program memory. In assembly
language, the number sign character (#) indicates an immediate operand.
Example: Load Accumulator Immediate
LD A,#05
Reg/Data Contents Contents
Memory Before After
Accumulator XX Hex 05 Hex
Immediate Short. This is a special case of an immediate instruction. In the “Load B immediate”
instruction, the 4-bit immediate value in the instruction is loaded into the lower nibble of the B register. The
upper nibble of the B register is reset to 0000 binary.
Example: Load B Register Immediate Short
LD B,#7
Reg/Data Contents Contents
Memory Before After
B Pointer 12 Hex 07 Hex
Indirect from Program Memory. This is a special case of an indirect instruction that allows access to
data tables stored in program memory. In the “Load Accumulator Indirect” (LAID) instruction, the upper
and lower bytes of the Program Counter (PCU and PCL) are used temporarily as a pointer to program
memory. For purposes of accessing program memory, the contents of the Accumulator and PCL are
exchanged. The data pointed to by the Program Counter is loaded into the Accumulator, and
simultaneously, the original contents of PCL are restored so that the program can resume normal
execution.
Example: Load Accumulator Indirect
LAID
Reg/Data Contents Contents
Memory Before After
PCU 04 Hex 04 Hex
PCL 35 Hex 36 Hex
Accumulator 1F Hex 25 Hex
Memory Location 25 Hex 25 Hex
041F Hex
5.19.3.2 Tranfer-of-Control Addressing Modes
Program instructions are usually executed in sequential order. However, Jump instructions can be used to
change the normal execution sequence. Several transfer-of-control addressing modes are available to
specify jump addresses.
92 Functional Description Copyright © 2000–2013, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
www.ti.com
SNOS535I OCTOBER 2000REVISED MARCH 2013
A change in program flow requires a non-incremental change in the Program Counter contents. The
Program Counter consists of two bytes, designated the upper byte (PCU) and lower byte (PCL). The most
significant bit of PCU is not used, leaving 15 bits to address the program memory.
Different addressing modes are used to specify the new address for the Program Counter. The choice of
addressing mode depends primarily on the distance of the jump. Farther jumps sometimes require more
instruction bytes in order to completely specify the new Program Counter contents.
The available transfer-of-control addressing modes are:
Jump Relative
Jump Absolute
Jump Absolute Long
Jump Indirect
The transfer-of-control addressing modes are described below. Each description includes an example of a
Jump instruction using a particular addressing mode, and the effect on the Program Counter bytes of
executing that instruction.
Jump Relative. In this 1-byte instruction, six bits of the instruction opcode specify the distance of the jump
from the current program memory location. The distance of the jump can range from 31 to +32. A JP+1
instruction is not allowed. The programmer should use a NOP instead.
Example: Jump Relative
JP 0A
Contents Contents
Reg Before After
PCU 02 Hex 02 Hex
PCL 05 Hex 0F Hex
Jump Absolute. In this 2-byte instruction, 12 bits of the instruction opcode specify the new contents of the
Program Counter. The upper three bits of the Program Counter remain unchanged, restricting the new
Program Counter address to the same 4-kbyte address space as the current instruction. (This restriction is
relevant only in devices using more than one 4-kbyte program memory space.)
Example: Jump Absolute
JMP 0125
Contents Contents
Reg Before After
PCU 0C Hex 01 Hex
PCL 77 Hex 25 Hex
Jump Absolute Long. In this 3-byte instruction, 15 bits of the instruction opcode specify the new contents
of the Program Counter.
Example: Jump Absolute Long
JMP 03625
Reg/ Contents Contents
Memory Before After
PCU 42 Hex 36 Hex
PCL 36 Hex 25 Hex
Copyright © 2000–2013, Texas Instruments Incorporated Functional Description 93
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
SNOS535I OCTOBER 2000REVISED MARCH 2013
www.ti.com
Jump Indirect. In this 1-byte instruction, the lower byte of the jump address is obtained from a table
stored in program memory, with the Accumulator serving as the low order byte of a pointer into program
memory. For purposes of accessing program memory, the contents of the Accumulator are written to PCL
(temporarily). The data pointed to by the Program Counter (PCH/PCL) is loaded into PCL, while PCH
remains unchanged.
Example: Jump Indirect
JID
Reg/ Contents Contents
Memory Before After
PCU 01 Hex 01 Hex
PCL C4 Hex 32 Hex
Accumulator 26 Hex 26 Hex
Memory
Location 32 Hex 32 Hex
0126 Hex
The VIS instruction is a special case of the Indirect Transfer of Control addressing mode, where the
double-byte vector associated with the interrupt is transferred from adjacent addresses in program
memory into the Program Counter in order to jump to the associated interrupt service routine.
5.19.4 INSTRUCTION TYPES
The instruction set contains a wide variety of instructions. The available instructions are listed below,
organized into related groups.
Some instructions test a condition and skip the next instruction if the condition is not true. Skipped
instructions are executed as no-operation (NOP) instructions.
5.19.4.1 Arithmetic Instructions
The arithmetic instructions perform binary arithmetic such as addition and subtraction, with or without the
Carry bit.
Add (ADD)
Add with Carry (ADC)
Subtract with Carry (SUBC)
Increment (INC)
Decrement (DEC)
Decimal Correct (DCOR)
Clear Accumulator (CLR)
Set Carry (SC)
Reset Carry (RC)
5.19.4.2 Transfer-of-Control Instructions
The transfer-of-control instructions change the usual sequential program flow by altering the contents of
the Program Counter. The Jump to Subroutine instructions save the Program Counter contents on the
stack before jumping; the Return instructions pop the top of the stack back into the Program Counter.
Jump Relative (JP)
94 Functional Description Copyright © 2000–2013, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
www.ti.com
SNOS535I OCTOBER 2000REVISED MARCH 2013
Jump Absolute (JMP)
Jump Absolute Long (JMPL)
Jump Indirect (JID)
Jump to Subroutine (JSR)
Jump to Subroutine Long (JSRL)
Jump to Boot ROM Subroutine (JSRB)
Return from Subroutine (RET)
Return from Subroutine and Skip (RETSK)
Return from Interrupt (RETI)
Software Trap Interrupt (INTR)
Vector Interrupt Select (VIS)
5.19.4.3 Load and Exchange Instructions
The load and exchange instructions write byte values in registers or memory. The addressing mode
determines the source of the data.
Load (LD)
Load Accumulator Indirect (LAID)
Exchange (X)
5.19.4.4 Logical Instructions
The logical instructions perform the operations AND, OR, and XOR (Exclusive OR). Other logical
operations can be performed by combining these basic operations. For example, complementing is
accomplished by exclusive-ORing the Accumulator with FF Hex.
Logical AND (AND)
Logical OR (OR)
Exclusive OR (XOR)
5.19.4.5 Accumulator Bit Manipulation Instructions
The Accumulator bit manipulation instructions allow the user to shift the Accumulator bits and to swap its
two nibbles.
Rotate Right Through Carry (RRC)
Rotate Left Through Carry (RLC)
Swap Nibbles of Accumulator (SWAP)
5.19.4.6 Stack Control Instructions
Push Data onto Stack (PUSH)
Pop Data off of Stack (POP)
5.19.4.7 Memory Bit Manipulation Instructions
The memory bit manipulation instructions allow the user to set and reset individual bits in memory.
Set Bit (SBIT)
Reset Bit (RBIT)
Copyright © 2000–2013, Texas Instruments Incorporated Functional Description 95
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
SNOS535I OCTOBER 2000REVISED MARCH 2013
www.ti.com
Reset Pending Bit (RPND)
5.19.4.8 Conditional Instructions
The conditional instruction test a condition. If the condition is true, the next instruction is executed in the
normal manner; if the condition is false, the next instruction is skipped.
If Equal (IFEQ)
If Not Equal (IFNE)
If Greater Than (IFGT)
If Carry (IFC)
If Not Carry (IFNC)
If Bit (IFBIT)
If B Pointer Not Equal (IFBNE)
And Skip if Zero (ANDSZ)
Decrement Register and Skip if Zero (DRSZ)
5.19.4.9 No-Operation Instruction
The no-operation instruction does nothing, except to occupy space in the program memory and time in
execution.
No-Operation (NOP)
NOTE
The VIS is a special case of the Indirect Transfer of Control addressing mode, where the
double byte vector associated with the interrupt is transferred from adjacent addresses in the
program memory into the program counter (PC) in order to jump to the associated interrupt
service routine.
5.19.5 REGISTER AND SYMBOL DEFINITION
The following abbreviations represent the nomenclature used in the instruction description and the COP8
cross-assembler.
Registers
A 8-Bit Accumulator Register
B 8-Bit Address Register
X 8-Bit Address Register
S 8-Bit Segment Register
SP 8-Bit Stack Pointer Register
PC 15-Bit Program Counter Register
PU Upper 7 Bits of PC
PL Lower 8 Bits of PC
C 1 Bit of PSW Register for Carry
HC 1 Bit of PSW Register for Half Carry
GIE 1 Bit of PSW Register for Global Interrupt Enable
VU Interrupt Vector Upper Byte
VL Interrupt Vector Lower Byte
96 Functional Description Copyright © 2000–2013, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
www.ti.com
SNOS535I OCTOBER 2000REVISED MARCH 2013
Symbols
[B] Memory Indirectly Addressed by B Register
[X] Memory Indirectly Addressed by X Register
MD Direct Addressed Memory
Mem Direct Addressed Memory or [B]
Meml Direct Addressed Memory or [B] or Immediate Data
Imm 8-Bit Immediate Data
Reg Register Memory: Addresses F0 to FF (Includes B, X and SP)
Bit Bit Number (0 to 7)
Loaded with
Exchanged with
5.19.6 INSTRUCTION SET SUMMARY
ADD A,Meml ADD AA + Meml
ADC A,Meml ADD with Carry AA + Meml + C, CCarry,
HCHalf Carry
SUBC A,Meml Subtract with Carry AAMemI + C, CCarry,
HCHalf Carry
AND A,Meml Logical AND AA and Meml
ANDSZ A,Imm Logical AND Immed., Skip if Zero Skip next if (A and Imm) = 0
OR A,Meml Logical OR AA or Meml
XOR A,Meml Logical EXclusive OR AA xor Meml
IFEQ MD,Imm IF EQual Compare MD and Imm, Do next if MD = Imm
IFEQ A,Meml IF EQual Compare A and Meml, Do next if A = Meml
IFNE A,Meml IF Not Equal Compare A and Meml, Do next if A Meml
IFGT A,Meml IF Greater Than Compare A and Meml, Do next if A > Meml
IFBNE # If B Not Equal Do next if lower 4 bits of B Imm
DRSZ Reg Decrement Reg., Skip if Zero RegReg 1, Skip if Reg = 0
SBIT #,Mem Set BIT 1 to bit, Mem (bit = 0 to 7 immediate)
RBIT #,Mem Reset BIT 0 to bit, Mem
IFBIT #,Mem IF BIT If bit #,A or Mem is true do next instruction
RPND Reset PeNDing Flag Reset Software Interrupt Pending Flag
X A,Mem EXchange A with Memory AMem
X A,[X] EXchange A with Memory [X] A[X]
LD A,Meml LoaD A with Memory AMeml
LD A,[X] LoaD A with Memory [X] A[X]
LD B,Imm LoaD B with Immed. BImm
LD Mem,Imm LoaD Memory Immed. MemImm
LD Reg,Imm LoaD Register Memory Immed. RegImm
X A, [B±] EXchange A with Memory [B] A[B], (B1)
X A, [X±] EXchange A with Memory [X] A[X], (X1)
LD A, [B±] LoaD A with Memory [B] A[B], (BB±1)
LD A, [X±] LoaD A with Memory [X] A[X], (XX±1)
LD [B±],Imm LoaD Memory [B] Immed. [B]Imm, (B1)
CLR A CLeaR A A0
INC A INCrement A AA + 1
DEC A DECrement A AA1
LAID Load A InDirect from ROM AROM (PU,A)
DCOR A Decimal CORrect A ABCD correction of A (follows ADC, SUBC)
RRC A Rotate A Right thru C CA7A0C
Copyright © 2000–2013, Texas Instruments Incorporated Functional Description 97
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
SNOS535I OCTOBER 2000REVISED MARCH 2013
www.ti.com
RLC A Rotate A Left thru C CA7A0C, HCA0
SWAP A SWAP nibbles of A A7…A4A3…A0
SC Set C C1, HC1
RC Reset C C0, HC0
IFC IF C IF C is true, do next instruction
IFNC IF Not C If C is not true, do next instruction
POP A POP the stack into A SPSP + 1, A[SP]
PUSH A PUSH A onto the stack [SP]A, SPSP 1
VIS Vector to Interrupt Service Routine PU[VU], PL[VL]
JMPL Addr. Jump absolute Long PCii (ii = 15 bits, 0 to 32k)
JMP Addr. Jump absolute PC9…0i (i = 12 bits)
JP Disp. Jump relative short PCPC + r (r is 31 to +32, except 1)
JSRL Addr. Jump SubRoutine Long [SP]PL, [SP1]PU,SP2, PCii
JSR Addr. Jump SubRoutine [SP]PL, [SP1]PU,SP2, PC9…0i
JSRB Addr Jump SubRoutine Boot ROM [SP]PL, [SP1]PU,SP2,
PLAddr,PU00, switch to flash
JID Jump InDirect PLROM (PU,A)
RET RETurn from subroutine SP + 2, PL[SP], PU[SP1]
RETSK RETurn and SKip SP + 2, PL[SP],PU[SP1],
skip next instruction
RETI RETurn from Interrupt SP + 2, PL[SP],PU[SP1],GIE1
INTR Generate an Interrupt [SP]PL, [SP1]PU, SP2, PC0FF
NOP No OPeration PCPC + 1
5.19.7 INSTRUCTION EXECUTION TIME
Most instructions are single byte (with immediate addressing mode instructions taking two bytes).
Most single byte instructions take one cycle time to execute.
Skipped instructions require x number of cycles to be skipped, where x equals the number of bytes in the
skipped instruction opcode.
See the BYTES and CYCLES per INSTRUCTION table for details.
Bytes and Cycles per Instruction
The following table shows the number of bytes and cycles for each instruction in the format of byte/cycle.
Arithmetic and Logic Instructions
[B] Direct Immed.
ADD 1/1 3/4 2/2
ADC 1/1 3/4 2/2
SUBC 1/1 3/4 2/2
AND 1/1 3/4 2/2
OR 1/1 3/4 2/2
XOR 1/1 3/4 2/2
IFEQ 1/1 3/4 2/2
IFGT 1/1 2/2
3/4
IFBNE 1/1
DRSZ 1/3
SBIT 1/1 3/4
RBIT 1/1 3/4
IFBIT 1/1 3/4
98 Functional Description Copyright © 2000–2013, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
www.ti.com
SNOS535I OCTOBER 2000REVISED MARCH 2013
RPND 1/1
Instructions Using A & C
CLRA 1/1
INCA 1/1
DECA 1/1
LAID 1/3
DCORA 1/1
RRCA 1/1
RLCA 1/1
SWAPA 1/1
SC 1/1
RC 1/1
IFC 1/1
IFNC 1/1
PUSHA 1/3
POPA 1/3
ANDSZ 2/2
Transfer of Control Instructions
JMPL 3/4
JMP 2/3
JP 1/3
JSRL 3/5
JSR 2/5
JSRB 2/5
JID 1/3
VIS 1/5
RET 1/5
RETSK 1/5
RETI 1/5
INTR 1/7
NOP 1/1
Table 5-32. Memory Transfer Instructions
Register Register Indirect
Indirect Direct Immed. Auto Incr. & Decr.
[B] [X] [B+, B] [X+, X]
X A,(1) 1/1 1/3 2/3 1/2 1/3
LD A,(1) 1/1 1/3 2/3 2/2 1/2 1/3
LD B,Imm 1/1 (If B < 16)
LD B,Imm 2/2 (If B > 15)
LD Mem,Imm 2/2 3/3 2/2
LD Reg,Imm 2/3
IFEQ MD,Imm 3/3
(1) = > Memory location addressed by B or X or directly.
Copyright © 2000–2013, Texas Instruments Incorporated Functional Description 99
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
SNOS535I OCTOBER 2000REVISED MARCH 2013
www.ti.com
Table 5-33. OPCODE(1)
Upper Nibble
F E D C B A 9 8 7 6 5 4 3 2 1 0
JP1 JP3 LD DRSZ RRCA RC ADC ADC IFBI ANDS LD IFBNE JSR JMP JP+1 INTR 0
5 1 0F0,#i 0F0 A,#i A,[B] T Z A,#i B,#0F 0 x000–x0 x000–x0 7
0,[B] FF FF
JP1 JP3 LD DRSZ * SC SUBC SUB IFBI JSRB LD IFBNE JSR JMP JP+1 JP+2 1
4 0 0F1,#i 0F1 A,#i C T B,#0E 1 x100–x1 x100–x1 8
A,[B] 1,[B] FF FF
JP1 JP2 LD DRSZ X X IFEQ IFEQ IFBI Re- LD IFBNE JSR JMP JP+1 JP+3 2
3 9 0F2,#i 0F2 A,[X+] A,[B A,#i A,[B] T served B,#0D 2 x200–x2 x200–x2 9
+] 2,[B] FF FF
JP1 JP2 LD DRSZ X X IFGT IFGT IFBI Re- LD IFBNE JSR JMP JP+2 JP+4 3
2 8 0F3,#i 0F3 A,[X] A,[B A,#i A,[B] T served B,#0C 3 x300–x3 x300–x3 0
] 3,[B] FF FF
JP1 JP2 LD DRSZ VIS LAID ADD ADD IFBI CLRA LD IFBNE JSR JMP JP+2 JP+5 4
1 7 0F4,#i 0F4 A,#i A,[B] T B,#0B 4 x400–x4 x400–x4 1
4,[B] FF FF
JP1 JP2 LD DRSZ RPND JID AND AND IFBI SWAP LD IFBNE JSR JMP JP+2 JP+6 5
0 6 0F5,#i 0F5 A,#i A,[B] T A B,#0A 5 x500–x5 x500–x5 2
5,[B] FF FF
JP9 JP2 LD DRSZ X X XOR XOR IFBI DCOR LD IFBNE JSR JMP JP+2 JP+7 6
5 0F6,#i 0F6 A,[X] A,[B] A,#i A,[B] T A B,#09 6 x600–x6 x600–x6 3
6,[B] FF FF Lo
JP8 JP2 LD DRSZ * * OR OR IFBI PUSH LD IFBNE JSR JMP JP+2 JP+8 7 w
4 0F7,#i 0F7 A,#i A,[B] T A B,#08 7 x700–x7 x700–x7 4 er
7,[B] FF FF Ni
JP7 JP2 LD DRSZ NOP RLC LD IFC SBIT RBIT LD IFBNE JSR JMP JP+2 JP+9 8 bb
3 0F8,#i 0F8 A A,#i 0,[B] 0,[B] B,#07 8 x800–x8 x800–x8 5 le
FF FF
JP6 JP2 LD DRSZ IFNE IFEQ IFNE IFNC SBIT RBIT LD IFBNE JSR JMP JP+2 JP+1 9
2 0F9,#i 0F9 A,[B] Md,# A,#i 1,[B] 1,[B] B,#06 9 x900–x9 x900–x9 6 0
i FF FF
JP5 JP2 LD DRSZ LD LD LD INCA SBIT RBIT LD IFBNE JSR JMP JP+2 JP+1 A
1 0FA,#i 0FA A,[X+] A,[B [B+],#i 2,[B] 2,[B] B,#05 0A xA00–xA xA00–xA 7 1
+] FF FF
JP4 JP2 LD DRSZ LD LD LD DEC SBIT RBIT LD IFBNE JSR JMP JP+2 JP+1 B
0 0FB,#i 0FB A,[X] A,[B [B],#i A 3,[B] 3,[B] B,#04 0B xB00–xB xB00–xB 8 2
] FF FF
JP3 JP1 LD DRSZ LD JMP X POP SBIT RBIT LD IFBNE JSR JMP JP+2 JP+1 C
9 0FC,#i 0FC Md,#i L A,Md A 4,[B] 4,[B] B,#03 0C xC00–xC xC00–xC 9 3
FF FF
JP2 JP1 LD DRSZ DIR JSR LD RET SBIT RBIT LD IFBNE JSR JMP JP+3 JP+1 D
8 0FD,#i 0FD L A,Md SK 5,[B] 5,[B] B,#02 0D xD00–xD xD00–xD 0 4
FF FF
JP1 JP1 LD DRSZ LD LD LD RET SBIT RBIT LD IFBNE JSR JMP JP+3 JP+1 E
7 0FE,#i 0FE A,[X] A,[B] [B],#i 6,[B] 6,[B] B,#01 0E xE00–xE xE00–xE 1 5
FF FF
JP0 JP1 LD DRSZ * * LD RETI SBIT RBIT LD IFBNE JSR JMP JP+3 JP+1 F
6 0FF,#i 0FF B,#i 7,[B] 7,[B] B,#00 0F xF00–xF xF00–xF 2 6
FF FF
(1) *is an unused opcodeiis the immediate data Md is a directly addressed memory location. The opcode 60 Hex is also the opcode for
IFBIT #i,A
5.20 Development Support
5.20.1 TOOLS ORDERING NUMBERS FOR THE COP8 FLASH FAMILY DEVICES
This section provides specific tools ordering information for the devices in this datasheet, followed by a
summary of the tools and development kits available at print time. Up-to-date information, device selection
guides, demos, updates, and purchase information can be obtained at our web site at: www.ti.com.
100 Functional Description Copyright © 2000–2013, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
www.ti.com
SNOS535I OCTOBER 2000REVISED MARCH 2013
Unless otherwise noted, tools can be purchased for worldwide delivery from TI's e-store:
http://estore.ti.com
Tool Order Number Cost* Notes/Includes
Evaluation Software and Reference Designs
Software and Web Downloads: www.ti.com Free Assembler/ Linker/ Simulators/ Library Manager/ Compiler
Utilities Demos/ Flash ISP and NiceMon Debugger Utilities/ Example
Code/ etc.
(Flash Emulator support requires licensed COP8-NSDEV CD-
ROM).
Hardware Reference COP8-REF-FL1 VL For COP8Flash Sx/Cx -Demo Board and Software; 44PLCC
Designs Socket; Stand-alone, or use as development target board with
Flash ISP and/or COP8Flash Emulator. Does not include COP8
development software.
COP8-REF-AM VL For COP8Flash Ax - Demo Board and Software; 28DIP Socket.
Stand alone, or use as development target board with Flash ISP
and/or COP8Flash Emulator. Does not include COP8 development
software.
Starter Kits and Hardware Target Boards
Starter Development COP8-SKFLASH-01 VL Supports COP8Sx/Cx/Ax -Target board with 68PLCC
Kits COP8CDR9, 44PLCC and 28DIP sockets, LEDs, Test Points, and
Breadboard Area. Development CD, ISP Cable, Debug Software
and Source Code. No p/s. Also supports COP8Flash Emulators
and Kanda ISP Tool.
COP8-REF-FL1 or VL COP8Flash Hardware Reference Design boards can also be used
COP8-REF-AM as Development Target boards, with ISP and Emulator onboard
connectors.
Software Development Languages, and Integrated Development Environments
TI's WCOP8 IDE COP8-NSDEV $3 Fully Licensed IDE with Assembler and Emulator/Debugger
and Assembler on Support. Assembler/ Linker/ Simulator/ Utilities/ Documentation.
CD Updates from web. Included with SKFlash, COP8 Emulators,
COP8-PM.
COP8 Library www.kkd.dk/libman.htm Eval The ultimate information source for COP8 developers -
Manager from KKD Integrates with WCOP8 IDE. Organize and manage code, notes,
datasheets, etc.
WEBENCH Online www.ti.com Free Online Graphical IDE, featuring UNIS Processor Expert( Code
Graphical /webench Development Tool with Simulator -Develop applications, simulate
Application Builder and debug, download working code. Online project manager.
With Unis Processor COP8-SW-PE2 L Graphical IDE and Code Development Tool with Simulator -
Expert Stand-alone, enhanced PC version of our WEBENCH tools on CD.
Byte Craft C COP8-SW-COP8C COP8-SW- M DOS/16bit Version - No IDE.
Compiler COP8CW H Win 32 Version with IDE.
IAR Embedded COP8-SW-EWCOP8 H Complete tool set, with COP8 Emulator/Debugger support.
Workbench Tool EWCOP8-BL M Baseline version - Purchase from IAR only.
Set. Assembler-Only Version Free Assembler only; No COP8 Emulator/Debugger support.
Hardware Emulation and Debug Tools
Hardware Emulators COP8-EMFlash-00 L Includes 110v/220v p/s, target cable with 2x7 connector, 68 pin
COP8-DMFlash-00 M COP8CDR9 Null Target, manuals and software on CD.
COP8-IMFlash-00 H - COP8AME/ANE9 uses optional 28 pin Null Target (COP8-
EMFA-28N).
- Add PLCC Target Package Adapter if needed.
Emulator Null Target COP8-EMFA-68N COP8-EMFA- VL 68 pin PLCC COP8CDR9; Included in COP8-EM/DM/IM Flash.
28N VL 28pin DIP COP8AME9; Must order seperately.
Emulator Target COP8-EMFA-44P VL 44 pin PLCC target package adapter. (Use instead of 2x7 emulator
Package Adapters header)
COP8-EMFA-68P VL 68 pin PLCC target package adapter. (Use instead of 2x7 emulator
header)
NiceMon Debug COP8-SW-NMON Free Download code and Monitor S/W for single-step debugging via
Monitor Utility Microwire. Includes PC control/debugger software and monitor
program.
Development and Production Programming Tools
Copyright © 2000–2013, Texas Instruments Incorporated Functional Description 101
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
SNOS535I OCTOBER 2000REVISED MARCH 2013
www.ti.com
TI's Engineering COP8-PM-02 L Board with 40DIP ZIF base socket for optional COP8FLASH
Programmer (Available late 2004) programming adapters; Includes 110v/220v p/s, manuals and
software on CD; (Requires optional -PGMA programming
adapters for flash)
Programming COP8-PGMA-28DF1 L For programming 28DIP COP8AM/AN only.
Adapters COP8-PGMA-28SF1 L For programming 28SOIC COP8AM/AN only.
(For any COP8-PGMA-44PF1 L For programming all 44PLCC COP8FLASH.
programmer
supporting flash COP8-PGMA-44CSF L For programming all 44WQFN COP8FLASH.
adapter base pinout) COP8-PGMA-48TF1 L For programming all 48TSSOP COP8 FLASH.
COP8-PGMA-68PF1 L For programming all 68PLCC COP8FLASH
COP8-PGMA-56TF1 L For programming all 56TSSOP COP8FLASH.
KANDA's Flash ISP COP8ISP L Parallel/Serial connected Dongle, with target cable and Control
Programmer www.kanda.com Software; Updateable from the web; Purchase from
www.kanda.com
Softec Flash ISP www.softecmicro.com L Serial connected cable, with control software; Purchase from
Programmer www.softecmicro.com
Development COP8CBR9/CCR9/CDR9 Free All packages. Obtain samples from: www.TI.com
Devices COP8CBE9/CCE9
COP8SBR9/SCR9/SDR9
COP8SBE9/SCE9
COP8AME9/ANE9
*Cost: Free; VL=<$100; L=$100-$300; M=$300-$1k; H=$1k-$3k; VH=$3k-$5k
5.20.2 COP8 TOOLS OVERVIEW
COP8 Evaluation Software and Reference Designs -
Software and Hardware for: Evaluation of COP8 Development Environments; Learning about COP8 Architecture and Features;
Demonstrating Application Specific Capabilities.
Product Description Source
WCOP8 IDE and Software Evaluation downloads for Windows. Includes WCOP8 IDE evaluation version, Full www.cop8.com
Software COP8 Assembler/Linker, COP8-SIM Instruction Level Simulator or Unis Simulator, Byte Craft FREE Download
Downloads COP8C Compiler Demo, IAR Embedded Workbench (Assembler version), Manuals, Applications
Software, and other COP8 technical information.
COP8 Hardware Reference Designs for COP8 Families. Realtime hardware environments with a variety of TI Distributor,
Reference Designs functions for demonstrating the various capabilities and features of specific COP8 device or Order from:
families. Run Windows demo reference software, and exercise specific device capabilities. Also www.cop8.com
can be used as a realtime target board for code development, with our flash development tools.
(Add our COP8Flash Emulator, or our COP8-NSDEV CD with your ISP cable for a complete low-
cost development system.)
COP8 Starter Kits and Hardware Target Solutions -
Hardware Kits for: In-depth Evaluation and Testing of COP8 capabilities; Developing and Testing Code; Implementing Target
Design.
Product Description Source
COP8 Flash Starter Flash Starter Kit - A complete Code Development Tool for COP8Flash Families. A Windows IDE TI Distributor,
Kits with Assembler, Simulator, and Debug Monitor, combined with a simple realtime target or Order from:
environment. Quickly design and simulate your code, then download to the target COP8flash www.cop8.com
device for execution and simple debugging. Includes a library of software routines, and source
code. No power supply.
(Add a COP8-EMFlash Emulator for advanced emulation and debugging)
COP8 Hardware Preconfigured realtime hardware environments with a variety of onboard I/O and display TI Distributor,
Reference Designs functions. Modify the reference software, or develop your own code. Boards support our COP8 or Order from:
ISP Utility, NiceMon Flash Debug Monitor, and our COP8Flash Emulators. www.cop8.com
COP8 Software Development Languages and Integrated Environments -
Integrated Software for: Project Management; Code Development; Simulation and Debug.
Product Description Source
WCOP8 IDE from TI's COP8 Software Development package for Windows on CD. Fully licensed versions of our TI Distributor, or
TI on CD-ROM WCOP8 IDE and Emulator Debugger, with Assembler/ Linker/ Simulators/ Library Manager/ Order from:
Compiler Demos/ Flash ISP and NiceMon Debugger Utilities/ Example Code/ etc. Includes all www.cop8.com
COP8 datasheets and documentation. Included with most tools from TI.
102 Functional Description Copyright © 2000–2013, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
www.ti.com
SNOS535I OCTOBER 2000REVISED MARCH 2013
COP8 Software Development Languages and Integrated Environments -
Integrated Software for: Project Management; Code Development; Simulation and Debug.
Product Description Source
Unis Processor Processor Expert( from Unis Corporation - COP8 Code Generation and Simulation tool with Unis, or Order
Expert Graphical and Traditional user interfaces. Automatically generates customized source code from:
"Beans" (modules) containing working code for all on-chip features and peripherals, then www.cop8.com
integrates them into a fully functional application code design, with all documentation.
Byte Craft COP8C ByteCraft COP8C- C Cross-Compiler and Code Development System. Includes BCLIDE ByteCraft
Compiler (Integrated Development Environment) for Win32, editor, optimizing C Cross-Compiler, macro Distributor,
cross assembler, BC-Linker, and MetaLinktools support. (DOS/SUN versions available; Compiler or Order from:
is linkable under WCOP8 IDE) www.cop8.com
IAR Embedded IAR EWCOP8 - ANSI C-Compiler and Embedded Workbench. A fully integrated Win32 IDE, IAR Distributor,
Workbench ANSI C-Compiler, macro assembler, editor, linker, librarian, and C-Spy high-level or Order from:
simulator/debugger. (EWCOP8-M version includes COP8Flash Emulator support) (EWCOP8-BL www.cop8.com
version is limited to 4k code limit; no FP).
COP8 Hardware Emulation/Debug Tools -
Hardware Tools for: Real-time Emulation; Target Hardware Debug; Target Design Test.
Product Description Source
COP8Flash COP8 In-Circuit Emulator for Flash Families. Windows based development and real-time in- TI Distributor,
Emulators - COP8- circuit emulation tool, with trace (EM=None; DM/IM=32k), s/w breakpoints (DM=16, EM/IM=32K), or Order from:
EMFlash COP8- source/symbolic debugger, and device programming. Includes COP8-NDEV CD, 68pin Null www.cop8.com
DMFlash COP8- Target, emulation cable with 2x7 connector, and power supply.
IMFlash
NiceMon Debug A simple, single-step debug monitor with one breadpoint. MICROWIRE interface. Download from:
Monitor Utility www.cop8.com
Development and Production Programming Tools -
Programmers for: Design Development; Hardware Test; Pre-Production; Full Production.
Product Description Source
COP8 Flash COP8 Flash Emulators include in-circuit device programming capability during development. TI Distributor, or
Emulators Order from:
www.cop8.com
NiceMon Debugger, TI's software Utilities "KANDAFlash" and "NiceMon" provide development In-System- Download from:
KANDAFlash Programming for our Flash Starter Kit, our Prototype Development Board, or any other target www.cop8.com
board with appropriate connectors.
KANDA COP8-ISP The COP8-ISP programmer from KANDA is available for engineering, and small volume www.kanda.com
production use. PC parallel or serial interface.
SofTec Micro inDart The inDart COP8 programmer from KANDA is available for engineering and small volume www.softecmicro.com
COP8 production use. PC serial interface only.
COP8 Programming COP8-PM Development Programming Module. Windows programming tool for COP8 OTP TI Distributor, or
Module and Flash Families. Includes on-board 40 DIP programming socket, control software, RS232 Order from web.
cable, and power supply. (Requires optional COP8-PGMA programming adapters for
COP8FLASH devices)
Third-Party A variety of third-party programmers and automatic handling equipment are approved for Various Vendors
Programmers non-ISP engineering and production use.
Factory Factory programming available for high-volume requirements. TI Representative
Programming
Copyright © 2000–2013, Texas Instruments Incorporated Functional Description 103
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
COP8CBR9, COP8CCR9, COP8CDR9
SNOS535I OCTOBER 2000REVISED MARCH 2013
www.ti.com
Revision History
NOTE: Page numbers for previous revisions may differ from page numbers in the current version.
Date Section Summary of Changes
October 2000 Base revision for this history.
April 2001 Throughout Various typographical errors.
Electrical Specifications Reduced dynamic supply current specification.
Reduced input leakage current.
Added general statement regarding specification limits.
Added temp range 7 (40°C to +125°C)
In-System Programming Clarified use of high voltage on G6 pin to force execution from Boot ROM.
May 2001 Added WQFN and TSSOP Packages
Sept., 2001 Development Support Updated with the latest support information.
January 2002 Forced Execution from Added Figure.
Boot ROM
April 2002 Pin Descriptions Caution on GND connection on WQFN package.
Timers Clarification on high speed PWM Timer use.
Development Support Updated with the latest support information.
August 2003 Pin Descriptions Clarification of the functions of L4 and L6 for T2 and T3 PWM Output.
Reset Addition of caution regarding rising edge on RESET with low VCC.
Power Saving Features Description of modified function of ITMR Register.
A/D Converter Updated specifications to reflect final product and test specifications.
Specifications
Development Support Updated with the latest support information.
Released as final.
March 2013 All Changed layout of National Data Sheet to TI format
104 Functional Description Copyright © 2000–2013, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: COP8CBR9 COP8CCR9 COP8CDR9
PACKAGE OPTION ADDENDUM
www.ti.com 18-Oct-2013
Addendum-Page 1
PACKAGING INFORMATION
Orderable Device Status
(1)
Package Type Package
Drawing Pins Package
Qty Eco Plan
(2)
Lead/Ball Finish
(6)
MSL Peak Temp
(3)
Op Temp (°C) Device Marking
(4/5)
Samples
COP8CBR9HVA8/NOPB ACTIVE PLCC FN 44 25 Green (RoHS
& no Sb/Br) SN Level-2A-245C-4
WEEK -40 to 85 COP8CBR9HVA8
COP8CBR9IMT8/NOPB ACTIVE TSSOP DGG 48 38 Green (RoHS
& no Sb/Br) CU SN Level-2-260C-1 YEAR -40 to 85 COP8CBR9IMT8
COP8CCR9HVA8/NOPB ACTIVE PLCC FN 44 25 Green (RoHS
& no Sb/Br) SN Level-3-245C-168 HR -40 to 125 COP8CCR9HVA8
COP8CCR9IMT7/NOPB ACTIVE TSSOP DGG 48 38 Green (RoHS
& no Sb/Br) SN | CU SN Level-2-260C-1 YEAR -40 to 125 COP8CCR9IMT7
COP8CCR9IMT8/63SN ACTIVE TSSOP DGG 48 1000 Green (RoHS
& no Sb/Br) SN | CU SN Level-2-260C-1 YEAR COP8CCR9IMT8
COP8CCR9IMT8/NOPB ACTIVE TSSOP DGG 48 38 Green (RoHS
& no Sb/Br) SN | CU SN Level-2-260C-1 YEAR -40 to 125 COP8CCR9IMT8
COP8CCR9LVA7/63SN ACTIVE PLCC FN 68 250 Green (RoHS
& no Sb/Br) SN Level-4-245C-72 HR COP8CCR9LVA7
COP8CCR9LVA7/NOPB ACTIVE PLCC FN 68 18 Green (RoHS
& no Sb/Br) SN Level-2A-245C-4
WEEK -40 to 125 COP8CCR9LVA7
COP8CDR9HVA8/NOPB ACTIVE PLCC FN 44 25 Green (RoHS
& no Sb/Br) SN Level-3-245C-168 HR -40 to 85 COP8CDR9HVA8
(1) The marketing status values are defined as follows:
ACTIVE: Product device recommended for new designs.
LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect.
NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design.
PREVIEW: Device has been announced but is not in production. Samples may or may not be available.
OBSOLETE: TI has discontinued the production of the device.
(2) Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontent for the latest availability
information and additional product content details.
TBD: The Pb-Free/Green conversion plan has not been defined.
Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that
lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes.
Pb-Free (RoHS Exempt): This component has a RoHS exemption for either 1) lead-based flip-chip solder bumps used between the die and package, or 2) lead-based die adhesive used between
the die and leadframe. The component is otherwise considered Pb-Free (RoHS compatible) as defined above.
Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame retardants (Br or Sb do not exceed 0.1% by weight
in homogeneous material)
PACKAGE OPTION ADDENDUM
www.ti.com 18-Oct-2013
Addendum-Page 2
(3) MSL, Peak Temp. - The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder temperature.
(4) There may be additional marking, which relates to the logo, the lot trace code information, or the environmental category on the device.
(5) Multiple Device Markings will be inside parentheses. Only one Device Marking contained in parentheses and separated by a "~" will appear on a device. If a line is indented then it is a continuation
of the previous line and the two combined represent the entire Device Marking for that device.
(6) Lead/Ball Finish - Orderable Devices may have multiple material finish options. Finish options are separated by a vertical ruled line. Lead/Ball Finish values may wrap to two lines if the finish
value exceeds the maximum column width.
Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information
provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and
continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals.
TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release.
In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis.
TAPE AND REEL INFORMATION
*All dimensions are nominal
Device Package
Type Package
Drawing Pins SPQ Reel
Diameter
(mm)
Reel
Width
W1 (mm)
A0
(mm) B0
(mm) K0
(mm) P1
(mm) W
(mm) Pin1
Quadrant
COP8CCR9IMT8/63SN TSSOP DGG 48 1000 330.0 24.4 8.6 13.2 1.6 12.0 24.0 Q1
PACKAGE MATERIALS INFORMATION
www.ti.com 26-Mar-2013
Pack Materials-Page 1
*All dimensions are nominal
Device Package Type Package Drawing Pins SPQ Length (mm) Width (mm) Height (mm)
COP8CCR9IMT8/63SN TSSOP DGG 48 1000 367.0 367.0 45.0
PACKAGE MATERIALS INFORMATION
www.ti.com 26-Mar-2013
Pack Materials-Page 2
MECHANICAL DATA
MPLC004A – OCTOBER 1994
1
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
FN (S-PQCC-J**) PLASTIC J-LEADED CHIP CARRIER
4040005/B 03/95
20 PIN SHOWN
0.026 (0,66)
0.032 (0,81)
D2/E2
0.020 (0,51) MIN
0.180 (4,57) MAX
0.120 (3,05)
0.090 (2,29)
D2/E2
0.013 (0,33)
0.021 (0,53)
Seating Plane
MAX
D2/E2
0.219 (5,56)
0.169 (4,29)
0.319 (8,10)
0.469 (11,91)
0.569 (14,45)
0.369 (9,37)
MAX
0.356 (9,04)
0.456 (11,58)
0.656 (16,66)
0.008 (0,20) NOM
1.158 (29,41)
0.958 (24,33)
0.756 (19,20)
0.191 (4,85)
0.141 (3,58)
MIN
0.441 (11,20)
0.541 (13,74)
0.291 (7,39)
0.341 (8,66)
18
19
14
13
D
D1
13
9
E1E
4
8
MINMAXMIN
PINS
**
20
28
44
0.385 (9,78)
0.485 (12,32)
0.685 (17,40)
52
68
84 1.185 (30,10)
0.985 (25,02)
0.785 (19,94)
D/E
0.395 (10,03)
0.495 (12,57)
1.195 (30,35)
0.995 (25,27)
0.695 (17,65)
0.795 (20,19)
NO. OF D1/E1
0.350 (8,89)
0.450 (11,43)
1.150 (29,21)
0.950 (24,13)
0.650 (16,51)
0.750 (19,05)
0.004 (0,10)
M
0.007 (0,18)
0.050 (1,27)
NOTES: A. All linear dimensions are in inches (millimeters).
B. This drawing is subject to change without notice.
C. Falls within JEDEC MS-018
MECHANICAL DATA
MTSS003D – JANUARY 1995 – REVISED JANUAR Y 1998
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
DGG (R-PDSO-G**) PLASTIC SMALL-OUTLINE PACKAGE
4040078/F 12/97
48 PINS SHOWN
0,25
0,15 NOM
Gage Plane
6,00
6,20 8,30
7,90
0,75
0,50
Seating Plane
25
0,27
0,17
24
A
48
1
1,20 MAX
M
0,08
0,10
0,50
0°–8°
56
14,10
13,90
48
DIM
A MAX
A MIN
PINS **
12,40
12,60
64
17,10
16,90
0,15
0,05
NOTES: A. All linear dimensions are in millimeters.
B. This drawing is subject to change without notice.
C. Body dimensions do not include mold protrusion not to exceed 0,15.
D. Falls within JEDEC MO-153
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, enhancements, improvements and other
changes to its semiconductor products and services per JESD46, latest issue, and to discontinue any product or service per JESD48, latest
issue. Buyers should obtain the latest relevant information before placing orders and should verify that such information is current and
complete. All semiconductor products (also referred to herein as “components”) are sold subject to TI’s terms and conditions of sale
supplied at the time of order acknowledgment.
TI warrants performance of its components to the specifications applicable at the time of sale, in accordance with the warranty in TI’s terms
and conditions of sale of semiconductor products. Testing and other quality control techniques are used to the extent TI deems necessary
to support this warranty. Except where mandated by applicable law, testing of all parameters of each component is not necessarily
performed.
TI assumes no liability for applications assistance or the design of Buyers’ products. Buyers are responsible for their products and
applications using TI components. To minimize the risks associated with Buyers’ products and applications, Buyers should provide
adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or
other intellectual property right relating to any combination, machine, or process in which TI components or services are used. Information
published by TI regarding third-party products or services does not constitute a license to use such products or services or a warranty or
endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the
third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of significant portions of TI information in TI data books or data sheets is permissible only if reproduction is without alteration
and is accompanied by all associated warranties, conditions, limitations, and notices. TI is not responsible or liable for such altered
documentation. Information of third parties may be subject to additional restrictions.
Resale of TI components or services with statements different from or beyond the parameters stated by TI for that component or service
voids all express and any implied warranties for the associated TI component or service and is an unfair and deceptive business practice.
TI is not responsible or liable for any such statements.
Buyer acknowledges and agrees that it is solely responsible for compliance with all legal, regulatory and safety-related requirements
concerning its products, and any use of TI components in its applications, notwithstanding any applications-related information or support
that may be provided by TI. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards which
anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause
harm and take appropriate remedial actions. Buyer will fully indemnify TI and its representatives against any damages arising out of the use
of any TI components in safety-critical applications.
In some cases, TI components may be promoted specifically to facilitate safety-related applications. With such components, TI’s goal is to
help enable customers to design and create their own end-product solutions that meet applicable functional safety standards and
requirements. Nonetheless, such components are subject to these terms.
No TI components are authorized for use in FDA Class III (or similar life-critical medical equipment) unless authorized officers of the parties
have executed a special agreement specifically governing such use.
Only those TI components which TI has specifically designated as military grade or “enhanced plastic” are designed and intended for use in
military/aerospace applications or environments. Buyer acknowledges and agrees that any military or aerospace use of TI components
which have not been so designated is solely at the Buyer's risk, and that Buyer is solely responsible for compliance with all legal and
regulatory requirements in connection with such use.
TI has specifically designated certain components as meeting ISO/TS16949 requirements, mainly for automotive use. In any case of use of
non-designated products, TI will not be responsible for any failure to meet ISO/TS16949.
Products Applications
Audio www.ti.com/audio Automotive and Transportation www.ti.com/automotive
Amplifiers amplifier.ti.com Communications and Telecom www.ti.com/communications
Data Converters dataconverter.ti.com Computers and Peripherals www.ti.com/computers
DLP® Products www.dlp.com Consumer Electronics www.ti.com/consumer-apps
DSP dsp.ti.com Energy and Lighting www.ti.com/energy
Clocks and Timers www.ti.com/clocks Industrial www.ti.com/industrial
Interface interface.ti.com Medical www.ti.com/medical
Logic logic.ti.com Security www.ti.com/security
Power Mgmt power.ti.com Space, Avionics and Defense www.ti.com/space-avionics-defense
Microcontrollers microcontroller.ti.com Video and Imaging www.ti.com/video
RFID www.ti-rfid.com
OMAP Applications Processors www.ti.com/omap TI E2E Community e2e.ti.com
Wireless Connectivity www.ti.com/wirelessconnectivity
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265