Cylindrical Proximity Sensor E2B Perfect fit for standard environments * Embody two seemingly contradictory characteristics: value-formoney and high reliability * All 372 Models * Four different sizes: M8, M12, M18 and M30 * Single and double sensing distances, Shielded and unshielded * A choice of short and long bodies, two connecting methods and four output types * Operating temperature: -25C to 70C * Water resistance: IP67 * With an all-round 360 visible indicator Refer to Safety Precautions on page 20. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Features Wide Variation Reliable Performance "Double Distance" Close at Hand Perfect Fit to Your Application Needs 360-degree indication Easy visibility for 360 even in dark locations so you can mount the sensor in any direction. With no less than 372 models in the family. You can choose the one that exactly meets your needs. E2B series can save cost & your time via single source. Long body for easy adjustment after mounting Oil-mist environment resistant! Output configuration: PNP/NPN Operation mode: NO/NC All ar ou n Short/ Long Bodies * The 360-degree indication is only for Pre-wired Models of M12, M18, and M30. * The other models (Pre-wired Models of M8 and all the Connector Models) have 4 LEDs at 90-degree intervals, which realize clear visibility from a 360-degree angle. d sib Vi le Shielded/ U nshielded Unshielded Pre-wired/ Connectors Conn nectors Shielded models for better noise immunity Connectors for easy maintenance Wide range of size Sensing distance Lineup of models from M8 to M30 Models available with standard distance(x1) and double distance (x2) 0 M8 8 M12 5 10 4 mm 8 mm Single distance (x1) Double distance (x2) x1 M18 M30 25 With the double distance, you can get almost the same sensing distance with a sensor that is one size smaller. M18 M12 x1 x2 20 "Double distance" saves space and reduces costs x1 x2 15 x2 x1 x2 2 16 IP67 30 We have performed not only a specified test for rating the degree of protection (IP67) for catalogs, but also tests with oil mist which appears onsite. Simulation tests has been performed with attachment of high concentration of oil mist. Degree of Protection E2B E2E (M8/M12/M18/ M30 size) Small Dia E2E (3 dia./4 dia./ 6.5 dia/M4/M5) mm Water resistance 30 x1 mm x2 Sensing distances of unshielded models IP67 IP67 IP69K *1 In oil-mist of soluble cutting oil diluted, 250 hours, the temperature of atmosphere is 23C Soaked in oil (solu- Soaked in insoluble ble type and insolu- oil 250 hours, temble) 500 hours, perature of oil 50C temperature of oil 50C IP67 Oil resistance 10 cm under 10 cm under *1. There are so many kinds of E2E, not all IP69K rated. In detailed part#, please contact your OMRON representative. 1 E2B Ordering Information Sensing distance Size Connecting method (See note 1.) Body length Short Pre-wired Long Shielded 1.5 mm M8 Connector (3-pin) Short Long Single Short Pre-wired Long Unshielded 2 mm M8 Connector (3-pin) M8 (Stainless steel) (See note 2.) Short Long Short Pre-wired Long Shielded 2 mm M8 Connector (3-pin) Short Long Double Short Pre-wired Long Unshielded 4 mm M8 Connector (3-pin) Short Long Output configuration PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN Operation mode NO Operation mode NC E2B-S08KS01-WP-B1 2M E2B-S08KS01-WP-C1 2M E2B-S08LS01-WP-B1 2M E2B-S08LS01-WP-C1 2M E2B-S08KS01-MC-B1 E2B-S08KS01-MC-C1 E2B-S08LS01-MC-B1 E2B-S08LS01-MC-C1 E2B-S08KN02-WP-B1 2M E2B-S08KN02-WP-C1 2M E2B-S08LN02-WP-B1 2M E2B-S08LN02-WP-C1 2M E2B-S08KN02-MC-B1 E2B-S08KN02-MC-C1 E2B-S08LN02-MC-B1 E2B-S08LN02-MC-C1 E2B-S08KS02-WP-B1 2M E2B-S08KS02-WP-C1 2M E2B-S08LS02-WP-B1 2M E2B-S08LS02-WP-C1 2M E2B-S08KS02-MC-B1 E2B-S08KS02-MC-C1 E2B-S08LS02-MC-B1 E2B-S08LS02-MC-C1 E2B-S08KN04-WP-B1 2M E2B-S08KN04-WP-C1 2M E2B-S08LN04-WP-B1 2M E2B-S08LN04-WP-C1 2M E2B-S08KN04-MC-B1 E2B-S08KN04-MC-C1 E2B-S08LN04-MC-B1 E2B-S08LN04-MC-C1 E2B-S08KS01-WP-B2 2M E2B-S08KS01-WP-C2 2M E2B-S08LS01-WP-B2 2M E2B-S08LS01-WP-C2 2M E2B-S08KS01-MC-B2 E2B-S08KS01-MC-C2 E2B-S08LS01-MC-B2 E2B-S08LS01-MC-C2 E2B-S08KN02-WP-B2 2M E2B-S08KN02-WP-C2 2M E2B-S08LN02-WP-B2 2M E2B-S08LN02-WP-C2 2M E2B-S08KN02-MC-B2 E2B-S08KN02-MC-C2 E2B-S08LN02-MC-B2 E2B-S08LN02-MC-C2 E2B-S08KS02-WP-B2 2M E2B-S08KS02-WP-C2 2M E2B-S08LS02-WP-B2 2M E2B-S08LS02-WP-C2 2M E2B-S08KS02-MC-B2 E2B-S08KS02-MC-C2 E2B-S08LS02-MC-B2 E2B-S08LS02-MC-C2 E2B-S08KN04-WP-B2 2M E2B-S08KN04-WP-C2 2M E2B-S08LN04-WP-B2 2M E2B-S08LN04-WP-C2 2M E2B-S08KN04-MC-B2 E2B-S08KN04-MC-C2 E2B-S08LN04-MC-B2 E2B-S08LN04-MC-C2 Note: 1. Pre-wired Models are available in the cable lengths of 2 m and 5 m. 2. Material specifications for stainless steel housing case: 1.4305 (W.-No.), SUS 303 (AISI), 2346 (SS). Sensing distance Size Connecting method (See note 1.) Body length Short Pre-wired Long Shielded 2 mm M12 Connector Short Long Single Short Pre-wired Long Unshielded 5 mm M12 Connector Short Long M12 (Brass) Short Pre-wired Shielded (See note 2.) Long 4 mm M12 Connector Short Long Double Short Pre-wired Long Unshielded 8 mm M12 Connector Note: 1. Pre-wired Models are available in the cable lengths of 2 m and 5 m. 2. There are restrictions that apply to Shielded sensors. Please refer to "Effects of Surrounding Metal" on page 20. 2 Short Long Output configuration PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN Operation mode NO Operation mode NC E2B-M12KS02-WP-B1 2M E2B-M12KS02-WP-C1 2M E2B-M12LS02-WP-B1 2M E2B-M12LS02-WP-C1 2M E2B-M12KS02-M1-B1 E2B-M12KS02-M1-C1 E2B-M12LS02-M1-B1 E2B-M12LS02-M1-C1 E2B-M12KN05-WP-B1 2M E2B-M12KN05-WP-C1 2M E2B-M12LN05-WP-B1 2M E2B-M12LN05-WP-C1 2M E2B-M12KN05-M1-B1 E2B-M12KN05-M1-C1 E2B-M12LN05-M1-B1 E2B-M12LN05-M1-C1 E2B-M12KS04-WP-B1 2M E2B-M12KS04-WP-C1 2M E2B-M12LS04-WP-B1 2M E2B-M12LS04-WP-C1 2M E2B-M12KS04-M1-B1 E2B-M12KS04-M1-C1 E2B-M12LS04-M1-B1 E2B-M12LS04-M1-C1 E2B-M12KN08-WP-B1 2M E2B-M12KN08-WP-C1 2M E2B-M12LN08-WP-B1 2M E2B-M12LN08-WP-C1 2M E2B-M12KN08-M1-B1 E2B-M12KN08-M1-C1 E2B-M12LN08-M1-B1 E2B-M12LN08-M1-C1 E2B-M12KS02-WP-B2 2M E2B-M12KS02-WP-C2 2M E2B-M12LS02-WP-B2 2M E2B-M12LS02-WP-C2 2M E2B-M12KS02-M1-B2 E2B-M12KS02-M1-C2 E2B-M12LS02-M1-B2 E2B-M12LS02-M1-C2 E2B-M12KN05-WP-B2 2M E2B-M12KN05-WP-C2 2M E2B-M12LN05-WP-B2 2M E2B-M12LN05-WP-C2 2M E2B-M12KN05-M1-B2 E2B-M12KN05-M1-C2 E2B-M12LN05-M1-B2 E2B-M12LN05-M1-C2 E2B-M12KS04-WP-B2 2M E2B-M12KS04-WP-C2 2M E2B-M12LS04-WP-B2 2M E2B-M12LS04-WP-C2 2M E2B-M12KS04-M1-B2 E2B-M12KS04-M1-C2 E2B-M12LS04-M1-B2 E2B-M12LS04-M1-C2 E2B-M12KN08-WP-B2 2M E2B-M12KN08-WP-C2 2M E2B-M12LN08-WP-B2 2M E2B-M12LN08-WP-C2 2M E2B-M12KN08-M1-B2 E2B-M12KN08-M1-C2 E2B-M12LN08-M1-B2 E2B-M12LN08-M1-C2 E2B Sensing distance Size Connecting method (See note 1.) Body length Short Pre-wired Long Shielded 5 mm M12 Connector Short Long Single Short Pre-wired Long Unshielded 10 mm M12 Connector Short Long M18 (Brass) Short Pre-wired Shielded (See note 2.) Long 8 mm M12 Connector Short Long Double Short Pre-wired Long Unshielded 16 mm M12 Connector Short Long Output configuration PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN Operation mode NO Operation mode NC E2B-M18KS05-WP-B1 2M E2B-M18KS05-WP-C1 2M E2B-M18LS05-WP-B1 2M E2B-M18LS05-WP-C1 2M E2B-M18KS05-M1-B1 E2B-M18KS05-M1-C1 E2B-M18LS05-M1-B1 E2B-M18LS05-M1-C1 E2B-M18KN10-WP-B1 2M E2B-M18KN10-WP-C1 2M E2B-M18LN10-WP-B1 2M E2B-M18LN10-WP-C1 2M E2B-M18KN10-M1-B1 E2B-M18KN10-M1-C1 E2B-M18LN10-M1-B1 E2B-M18LN10-M1-C1 E2B-M18KS08-WP-B1 2M E2B-M18KS08-WP-C1 2M E2B-M18LS08-WP-B1 2M E2B-M18LS08-WP-C1 2M E2B-M18KS08-M1-B1 E2B-M18KS08-M1-C1 E2B-M18LS08-M1-B1 E2B-M18LS08-M1-C1 E2B-M18KN16-WP-B1 2M E2B-M18KN16-WP-C1 2M E2B-M18LN16-WP-B1 2M E2B-M18LN16-WP-C1 2M E2B-M18KN16-M1-B1 E2B-M18KN16-M1-C1 E2B-M18LN16-M1-B1 E2B-M18LN16-M1-C1 E2B-M18KS05-WP-B2 2M E2B-M18KS05-WP-C2 2M E2B-M18LS05-WP-B2 2M E2B-M18LS05-WP-C2 2M E2B-M18KS05-M1-B2 E2B-M18KS05-M1-C2 E2B-M18LS05-M1-B2 E2B-M18LS05-M1-C2 E2B-M18KN10-WP-B2 2M E2B-M18KN10-WP-C2 2M E2B-M18LN10-WP-B2 2M E2B-M18LN10-WP-C2 2M E2B-M18KN10-M1-B2 E2B-M18KN10-M1-C2 E2B-M18LN10-M1-B2 E2B-M18LN10-M1-C2 E2B-M18KS08-WP-B2 2M E2B-M18KS08-WP-C2 2M E2B-M18LS08-WP-B2 2M E2B-M18LS08-WP-C2 2M E2B-M18KS08-M1-B2 E2B-M18KS08-M1-C2 E2B-M18LS08-M1-B2 E2B-M18LS08-M1-C2 E2B-M18KN16-WP-B2 2M E2B-M18KN16-WP-C2 2M E2B-M18LN16-WP-B2 2M E2B-M18LN16-WP-C2 2M E2B-M18KN16-M1-B2 E2B-M18KN16-M1-C2 E2B-M18LN16-M1-B2 E2B-M18LN16-M1-C2 Operation mode NO Operation mode NC E2B-M30KS10-WP-B1 2M E2B-M30KS10-WP-C1 2M E2B-M30LS10-WP-B1 2M E2B-M30LS10-WP-C1 2M E2B-M30KS10-M1-B1 E2B-M30KS10-M1-C1 E2B-M30LS10-M1-B1 E2B-M30LS10-M1-C1 E2B-M30KN20-WP-B1 2M E2B-M30KN20-WP-C1 2M E2B-M30LN20-WP-B1 2M E2B-M30LN20-WP-C1 2M E2B-M30KN20-M1-B1 E2B-M30KN20-M1-C1 E2B-M30LN20-M1-B1 E2B-M30LN20-M1-C1 E2B-M30KS15-WP-B1 2M E2B-M30KS15-WP-C1 2M E2B-M30LS15-WP-B1 2M E2B-M30LS15-WP-C1 2M E2B-M30KS15-M1-B1 E2B-M30KS15-M1-C1 E2B-M30LS15-M1-B1 E2B-M30LS15-M1-C1 E2B-M30LN30-WP-B1 2M E2B-M30LN30-WP-C1 2M E2B-M30LN30-M1-B1 E2B-M30LN30-M1-C1 E2B-M30KS10-WP-B2 2M E2B-M30KS10-WP-C2 2M E2B-M30LS10-WP-B2 2M E2B-M30LS10-WP-C2 2M E2B-M30KS10-M1-B2 E2B-M30KS10-M1-C2 E2B-M30LS10-M1-B2 E2B-M30LS10-M1-C2 E2B-M30KN20-WP-B2 2M E2B-M30KN20-WP-C2 2M E2B-M30LN20-WP-B2 2M E2B-M30LN20-WP-C2 2M E2B-M30KN20-M1-B2 E2B-M30KN20-M1-C2 E2B-M30LN20-M1-B2 E2B-M30LN20-M1-C2 E2B-M30KS15-WP-B2 2M E2B-M30KS15-WP-C2 2M E2B-M30LS15-WP-B2 2M E2B-M30LS15-WP-C2 2M E2B-M30KS15-M1-B2 E2B-M30KS15-M1-C2 E2B-M30LS15-M1-B2 E2B-M30LS15-M1-C2 E2B-M30LN30-WP-B2 2M E2B-M30LN30-WP-C2 2M E2B-M30LN30-M1-B2 E2B-M30LN30-M1-C2 Note: 1. Pre-wired Models are available in the cable lengths of 2 m and 5 m. 2. There are restrictions that apply to Shielded sensors. Please refer to "Effects of Surrounding Metal" on page 20. Sensing distance Size Connecting method (See note 1.) Body length Short Pre-wired Long Shielded 10 mm M12 Connector Short Long Single Short Pre-wired Long Unshielded 20 mm M12 Connector M30 (Brass) Short Long Short Pre-wired Shielded (See note 2.) Long 15 mm M12 Connector Double Unshielded 30 mm Short Long Pre-wired Long M12 Connector Long Output configuration PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN Note: 1. Pre-wired Models are available in the cable lengths of 2 m and 5 m. 2. There are restrictions that apply to Shielded sensors. Please refer to "Effects of Surrounding Metal" on page 20. 3 E2B Accessories (Order Separately) Sensor I/O Connectors Size Cable Shape Cores Straight PVC Right-angle 3 M8 (3-pin) Straight PVC Robot Right-angle Straight PVC Right-angle 4 M12 (4-pin) Straight PVC Robot Right-angle 4 Cable length (m) 2 5 2 5 2 5 2 5 2 5 2 5 2 5 2 5 Model XS3F-M8PVC3S2M XS3F-M8PVC3S5M XS3F-M8PVC3A2M XS3F-M8PVC3A5M XS3F-M321-302-R XS3F-M321-305-R XS3F-M322-302-R XS3F-M322-305-R XS2F-M12PVC4S2M XS2F-M12PVC4S5M XS2F-M12PVC4A2M XS2F-M12PVC4A5M XS2F-D421-D80-F XS2F-D421-G80-F XS2F-D422-D80-F XS2F-D422-G80-F E2B Model Number Legend E2B-@@@@@-@-@@ @ 1 2 3 4 5 6 7 8 9 10 Example: E2B-M12LS04-M1-B1 E2B-S08KN02-WP-C2 5M M12, Brass, Long body, Shielded, Sn = 4 mm, M12 connector, PNP, NO M8, stainless steel, Short body, Unshielded, Sn = 2 mm, Pre-wired PVC cable, NPN, NC, Cable length = 5 m 1. Basic name E2B 2. Housing shape and material M: Cylindrical, metric threaded, brass S: Cylindrical, metric threaded, stainless steel 3. Housing size 08: 8 mm 12: 12 mm 18: 18 mm 30: 30 mm 4. Barrel length K: Short body L: Long body 5. Shield S: N: Shielded Unshielded 6. Sensing distance Numeral: Sensing distance: 01 = 1.5 mm, 02 = 2 mm, 04 = 4 mm, 05 = 5 mm, 08 = 8 mm, 10 = 10 mm, 15 = 15 mm, 16 = 16 mm, 20 = 20 mm, 30 = 30 mm 7. Kind of connection WZ: Pre-wired, PVC, dia 4 mm Conductor cross section : 0.3 mm2 Insulator diameter : 1.3 mm (See note 1.) WP: Pre-wired, PVC, dia 4 mm Conductor cross section : 0.141 mm2 Insulator diameter : 0.85 mm M1: M12 connector MC: M8 connector (3 pin) (See note 2.) 8. Power source and output B: PNP C: NPN 9. Operation mode 1: NO (Normally open) 2: NC (Normally closed) 10.Cable length Blank: Connector type Numeral: Cable length (2M and 5M are available.) Note: 1. Only M12, M18, M30 type. 2. "WP", "M1" and "MC" are listed products of UL. 5 E2B Ratings and Specifications Size Sensing distance Type Item Model Sensing distance Setting distance Differential travel Detectable object Standard sensing object (mild steel ST37) Response frequency (See note 1.) Power supply voltage Current consumption Output type M8 Single Double Shielded Unshielded Shielded E2B-S08@S01 E2B-S08@N02 E2B-S08@S02 1.5 mm 10% 2 mm 10% 2 mm 10% 0 to 1.2 mm 0 to 1.6 mm 0 to 1.6 mm 10% max. of sensing distance Ferrous metal (The sensing distance decreases with non-ferrous metal.) Unshielded E2B-S08@N04 4 mm 10% 0 to 3.2 mm 8 x 8 x 1 mm 8 x 8 x 1 mm 12 x 12 x 1 mm 1,500 Hz 1,000 Hz 8 x 8 x 1 mm 2,000 Hz 1,000 Hz 10 to 30 VDC. (including 10% ripple (p-p)) 10 mA max. -B models: PNP open collector -C models: NPN open collector Load current 200 mA max. (30 VDC max.) (See note 2.) Residual voltage 2 V max. (under load current of 200 mA with cable length of 2 m) Indicator Operation indicator (Yellow LED) Operation mode -B1/-C1 models: NO (with sensing object approaching) -B2/-C2 models: NC Output reverse polarity protection, Power source circuit reverse polarity protection, Surge suppressor, Protection circuit Short-circuit protection Ambient air temperature Operation and storage : -25 to 70C (with no icing or condensation) Temperature influence 10% max. of sensing distance at 23C within temperature range of -10 to 55C (See note 2.) 15% max. of sensing distance at 23C within temperature range of -25 to 70C Ambient humidity Operation and Storage: 35 to 95% Voltage influence 1% max. of sensing distance in 24 VDC 15% Insulation resistance 50 M min. (at 500 VDC) between current-carrying parts and case Dielectric strength 1,000 VAC at 50/60 Hz for 1 min between current-carrying parts and case Vibration resistance 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions Shock resistance 500 m/s2, 10 times each in X, Y and Z directions Standard and listings (1) IP67 (IEC60529) (2) EMC (EN60947-5-2) Pre-wired models (standard is 4 mm dia. PVC cable with length = 2 m, 5 m). Connecting method Connector models (M8-3pin) Pre-wired model Short body: Approx. 65 g, Long body: Approx. 65 g Weight (packaged) Connector model Short body: Approx. 20 g, Long body: Approx. 20 g Case Stainless steel (1.4305 (W.-No.), SUS 303 (AISI), 2346 (SS).) Sensing surface PBT Material Cable Standard cable is 4 mm dia. PVC. Clamping nut Brass-nickel plated Toothed washer Zinc-plated iron Control output Note: 1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object between sensing objects, and a setting distance of half the sensing distance. 2. When using any model of M8 size at an ambient temperature between -25C and 60C, use a load current of 200mA max., at an ambient temperature between 60C and 70C, use a load current of 100 mA max. 6 E2B Size Sensing distance Type Item Model Sensing distance Setting distance Differential travel Detectable object Standard sensing object (mild steel ST37) Response frequency (See note 1.) Power supply voltage Current consumption M12 Single Double Shielded Unshielded Shielded E2B-M12@S02 E2B-M12@N05 E2B-M12@S04 2 mm 10% 5 mm 10% 4 mm 10% 0 to 1.6 mm 0 to 4 mm 0 to 3.2 mm 10% max. of sensing distance Ferrous metal (The sensing distance decreases with non-ferrous metal.) Unshielded E2B-M12@N08 8 mm 10% 0 to 6.4 mm 12 x 12 x 1 mm 24 x 24 x 1 mm 15 x 15 x 1 mm 12 x 12 x 1 mm 1,500 Hz 800 Hz 1,000 Hz 800 Hz 10 to 30 VDC. (including 10% ripple (p-p)) 10 mA max. -B models: PNP open collector Output type -C models: NPN open collector Load current 200 mA max. (30 VDC max.) Control output Residual voltage 2 V max. (under load current of 200 mA with cable length of 2 m) Indicator Operation indicator (Yellow LED) Operation mode -B1/-C1 models: NO (with sensing object approaching) -B2/-C2 models: NC Output reverse polarity protection, Power source circuit reverse polarity protection, Surge suppressor, Protection circuit Short-circuit protection Ambient air temperature Operation and storage : -25 to 70C (with no icing or condensation) 10% max. of sensing distance at 23C within temperature range of -10 to 55C Temperature influence 15% max. of sensing distance at 23C within temperature range of -25 to 70C Ambient humidity Operation and Storage: 35 to 95% Voltage influence 1% max. of sensing distance in 24 VDC 15% Insulation resistance 50 M min. (at 500 VDC) between current-carrying parts and case Dielectric strength 1,000 VAC at 50/60 Hz for 1 min between current-carrying parts and case Vibration resistance 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions Shock resistance 1,000 m/s2, 10 times each in X, Y and Z directions Standard and listings (1) IP67 (IEC60529) (2) EMC (EN60947-5-2) Pre-wired models (standard is 4 mm dia. PVC cable with length = 2 m, 5 m). Connecting method Connector models (M12-4pin) Pre-wired model Short body: Approx. 75 g, Long body: Approx. 80 g (See note 2.) Weight (packaged) Connector model Short body: Approx. 35 g, Long body: Approx. 40 g Case Brass-nickel plated Sensing surface PBT Material Cable Standard cable is 4 mm dia. PVC. Clamping nut Brass-nickel plated Toothed washer Zinc-plated iron Note: 1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object between sensing objects, and a setting distance of half the sensing distance. 2. In case of `WP' cable type. 7 E2B Size Sensing distance Type Item Model Sensing distance Setting distance Differential travel Detectable object Standard sensing object (mild steel ST37) Response frequency (See note 1.) Power supply voltage Current consumption M18 Single Double Shielded Unshielded Shielded E2B-M18@S05 E2B-M18@N10 E2B-M18@S08 5 mm 10% 10 mm 10% 8 mm 10% 0 to 4 mm 0 to 8 mm 0 to 6.4 mm 10% max. of sensing distance Ferrous metal (The sensing distance decreases with non-ferrous metal.) Unshielded E2B-M18@N16 16 mm 10% 0 to 12.8 mm 18 x 18 x 1 mm 48 x 48 x 1 mm 30 x 30 x 1 mm 24 x 24 x 1 mm 600 Hz 400 Hz 500 Hz 400 Hz 10 to 30 VDC. (including 10% ripple (p-p)) 10 mA max. -B models: PNP open collector Output type -C models: NPN open collector Load current 200 mA max. (30 VDC max.) Control output Residual voltage 2 V max. (under load current of 200 mA with cable length of 2 m) Indicator Operation indicator (Yellow LED) Operation mode -B1/-C1 models: NO (with sensing object approaching) -B2/-C2 models: NC Output reverse polarity protection, Power source circuit reverse polarity protection, Surge suppressor, Protection circuit Short-circuit protection Ambient air temperature Operation and storage : -25 to 70C (with no icing or condensation) 10% max. of sensing distance at 23C within temperature range of -10 to 55C Temperature influence 15% max. of sensing distance at 23C within temperature range of -25 to 70C Ambient humidity Operation and Storage: 35 to 95% Voltage influence 1% max. of sensing distance in 24 VDC 15% Insulation resistance 50 M min. (at 500 VDC) between current-carrying parts and case Dielectric strength 1,000 VAC at 50/60 Hz for 1 min between current-carrying parts and case Vibration resistance 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions Shock resistance 1,000 m/s2, 10 times each in X, Y and Z directions Standard and listings (1) IP67 (IEC60529) (2) EMC (EN60947-5-2) Pre-wired models (standard is 4 mm dia. PVC cable with length = 2 m, 5 m). Connecting method Connector models (M12-4pin) Pre-wired model Short body: Approx. 95 g, Long body: Approx. 110 g (See note 2.) Weight (packaged) Connector model Short body: Approx. 60 g, Long body: Approx. 80 g Case Brass-nickel plated Sensing surface PBT Material Cable Standard cable is 4 mm dia. PVC. Clamping nut Brass-nickel plated Toothed washer Zinc-plated iron Note: 1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object between sensing objects, and a setting distance of half the sensing distance. 2. In case of `WP' cable type. 8 E2B Size Sensing distance Type Item Model Sensing distance Setting distance Differential travel Detectable object Standard sensing object (mild steel ST37) Response frequency (See note 1.) Power supply voltage Current consumption M30 Single Double Shielded Unshielded Shielded E2B-M30@S10 E2B-M30@N20 E2B-M30@S15 10 mm 10% 20 mm 10% 15 mm 10% 0 to 8 mm 0 to 16 mm 0 to 11.25 mm 10% max. of sensing distance Ferrous metal (The sensing distance decreases with non-ferrous metal.) Unshielded E2B-M30@N30 30 mm 10% 0 to 22.5 mm 30 x 30 x 1 mm 90 x 90 x 1 mm 60 x 60 x 1 mm 45 x 45 x 1 mm 400 Hz 100 Hz 250 Hz 100 Hz 10 to 30 VDC. (including 10% ripple (p-p)) 10 mA max. -B models: PNP open collector Output type -C models: NPN open collector Load current 200 mA max. (30 VDC max.) Control output Residual voltage 2 V max. (under load current of 200 mA with cable length of 2 m) Indicator Operation indicator (Yellow LED) Operation mode -B1/-C1 models: NO (with sensing object approaching) -B2/-C2 models: NC Output reverse polarity protection, Power source circuit reverse polarity protection, Surge suppressor, Protection circuit Short-circuit protection Ambient air temperature Operation and storage : -25 to 70C (with no icing or condensation) 10% max. of sensing distance at 23C within temperature range of -10 to 55C Temperature influence 15% max. of sensing distance at 23C within temperature range of -25 to 70C Ambient humidity Operation and Storage: 35 to 95% Voltage influence 1% max. of sensing distance in 24 VDC 15% Insulation resistance 50 M min. (at 500 VDC) between current-carrying parts and case Dielectric strength 1,000 VAC at 50/60 Hz for 1 min between current-carrying parts and case Vibration resistance 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions Shock resistance 1,000 m/s2, 10 times each in X, Y and Z directions Standard and listings (1) IP67 (IEC60529) (2) EMC (EN60947-5-2) Pre-wired models (standard is 4 mm dia. PVC cable with length = 2 m, 5 m). Connecting method Connector models (M12-4pin) Pre-wired model Short body: Approx. 160 g, Long body: Approx. 210 g (See note 2.) Weight (packaged) Connector model Short body: Approx. 140 g, Long body: Approx. 160 g Case Brass-nickel plated Sensing surface PBT Material Cable Standard cable is 4 mm dia. PVC. Clamping nut Brass-nickel plated Toothed washer Zinc-plated iron Note: 1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object between sensing objects, and a setting distance of half the sensing distance. 2. In case of `WP' cable type. 9 E2B Engineering Data (Reference Value) Influence of Sensing Object Size and Materials Shielded Models Unshielded Models E2B-S08 E2B-S08@S01 E2B-S08@N04 4 3.5 Y 3 X E2B-S08@S02 2.5 2 E2B-S08@S01 1.5 E2B-S08@N02 2.5 @d Sensing distance X (mm) 4.5 Sensing distance X (mm) M8 Sensing distance X (mm) Operating Range t = 1 mm X 2 Iron 1.5 Stainless steel (SUS304) 1 2.5 @d X t = 1 mm Iron 2 Stainless steel (SUS304) 1.5 Brass 1 Aluminium 1 E2B-S08@N02 Brass 0.5 Copper 0.5 Aluminium 0.5 Copper 0 -8 -6 -4 -2 0 2 4 6 0 8 5 10 15 20 25 0 Side length of sensing object d (mm) Distance Y (mm) @d X 2.5 10 15 20 25 30 E2B-S08@N04 3 Sensing distance X (mm) Sensing distance X (mm) E2B-S08@S02 5 Side length of sensing object d (mm) t = 1 mm Iron 2 1.5 Stainless steel (SUS304) 1 6 @d X t = 1 mm 5 Iron 4 3 Stainless steel (SUS304) 2 Brass Brass Aluminium Aluminium 0.5 1 Copper Copper 0 5 10 15 20 25 0 Side length of sensing object d (mm) 20 30 Influence of Sensing Object Size and Materials Shielded Models Unshielded Models E2B-M12 E2B-M12@S02 E2B-M12@N08 8 7 Y 6 E2B-M12@N05 X 5 4 E2B-M12@S04 3 2 2.5 @d X t = 1 mm Iron 2 1.5 Stainless steel (SUS304) 1 Brass 50 60 70 6 Iron 5 @d X t = 1 mm 4 3 Stainless steel (SUS304) Brass 2 Aluminium Aluminium E2B-M12@S02 0.5 Copper 1 Copper 1 0 -16 40 E2B-M12@N05 Sensing distance X (mm) 9 Sensing distance X (mm) M12 Sensing distance X (mm) Operating Range 10 Side length of sensing object d (mm) -12 -8 -4 0 4 8 12 16 0 5 10 15 20 25 0 Side length of sensing object d (mm) Distance Y (mm) 5 @d X 20 30 40 50 60 70 80 90 E2B-M12@N08 Sensing distance X (mm) Sensing distance X (mm) E2B-M12@S04 10 Side length of sensing object d (mm) t = 1 mm Iron 4 Stainless steel (SUS304) 3 Brass 2 Aluminium 9 Iron 8 @d X 7 t = 1 mm 6 5 Stainless steel (SUS304) 4 Brass 3 Aluminium Copper Copper 2 1 1 0 5 10 15 20 25 30 35 Side length of sensing object d (mm) 10 0 10 20 30 40 50 60 70 80 90 Side length of sensing object d (mm) E2B Influence of Sensing Object Size and Materials Shielded Models Unshielded Models E2B-M18 E2B-M18@S05 E2B-M18@N16 16 14 Y X 12 E2B-M18@N10 10 8 E2B-M18@S08 6 6 @d E2B-M18@N10 Sensing distance X (mm) 18 Sensing distance X (mm) M18 Sensing distance X (mm) Operating Range t = 1 mm X Iron 5 4 Stainless steel (SUS304) 3 Brass 2 Aluminium 12 @d X t = 1 mm Iron 10 8 Stainless steel (SUS304) 6 Brass 4 Aluminium E2B-M18@S05 Copper 4 Copper 1 2 2 0 -30 -20 -10 0 10 20 30 0 10 20 30 40 50 60 70 0 80 90 Side length of sensing object d (mm) Distance Y (mm) 8 Iron 7 Stainless steel (SUS304) 6 5 Brass 4 Aluminium 3 2 Copper @d X t = 1 mm 18 @d 16 40 X Stainless steel (SUS304) 10 8 Brass Aluminium 6 Copper 2 10 20 30 40 50 60 70 80 90 0 10 20 30 40 15 t = 1 mm Iron 10 8 Stainless steel (SUS304) 6 Brass 4 Y 0 -60 -40 -20 0 20 40 60 0 X 10 20 30 40 50 60 70 E2B-M30@S15 20 @d X 80 90 t = 1 mm Iron 20 15 Stainless steel (SUS304) 10 0 Side length of sensing object d (mm) Distance Y (mm) @d Brass Copper 5 2 E2B-M30@S10 70 Aluminium Copper X 5 25 Aluminium 10 20 30 40 50 60 70 80 90 100 Side length of sensing object d (mm) E2B-M30LN30 t = 1 mm 16 Iron 12 Stainless steel (SUS304) 8 Brass Aluminium Sensing distance X (mm) 10 E2B-M30@S15 X 60 E2B-M30@N20 Sensing distance X (mm) 20 Sensing distance X (mm) E2B-M30@N20 Sensing distance X (mm) Sensing distance X (mm) 25 @d 50 Side length of sensing object d (mm) E2B-M30@S10 30 80 90 12 E2B-M30 E2B-M30@N30 70 Iron Influence of Sensing Object Size and Materials Shielded Models Unshielded Models 12 60 t = 1 mm M30 35 50 14 Side length of sensing object d (mm) Operating Range 30 4 1 0 20 E2B-M18@N16 9 Sensing distance X (mm) Sensing distance X (mm) E2B-M18@S08 10 Side length of sensing object d (mm) 35 @d X 30 t = 1 mm Iron 25 Stainless steel (SUS304) 20 Brass 15 Aluminium 10 Copper Copper 4 5 0 10 20 30 40 50 60 70 80 90 100 Side length of sensing object d (mm) 0 10 20 30 40 50 60 70 80 90 100 Side length of sensing object d (mm) 11 E2B I/O Circuit Diagrams PNP Output Operation mode Model Timing chart Non-sensing zone Output circuit Sensing zone Proximity Sensor Sensing object (%) 100 Brown 1 0 Rated sensing distance NO ON OFF ON OFF Yellow indicator Black 4 main circuits 10 to 30 VDC Load Control output Blue 3 E2B-S08@-@-B@ Non-sensing zone Sensing zone Proximity Sensor M8 connector (3 pin) Pin Arrangement Sensing object (%) 100 0 4 Rated sensing distance NC 3 1 ON OFF Yellow indicator ON OFF Non-sensing zone Sensing zone Control output Proximity Sensor Sensing object (%) 100 Brown 1 0 Rated sensing distance NO ON OFF ON OFF Yellow indicator Black 4 or 2 main circuits Load Control output Blue 3 E2B-M12@-@-B@ E2B-M18@-@-B@ E2B-M30@-@-B@ 4 : NO 2 : NC Non-sensing zone Sensing zone Proximity Sensor Sensing object (%) 100 0 1 Rated sensing distance NC 2 4 3 ON OFF Yellow indicator ON OFF 12 M12 Connector (4 pin) Pin Arrangement Control output 10 to 30 VDC E2B NPN Output Operation mode Model Timing chart Non-sensing zone Output circuit Sensing zone Proximity Sensor Sensing object (%) 100 Brown 1 0 Rated sensing distance NO Load ON OFF ON OFF Yellow indicator main circuits 10 to 30 VDC Black 4 Control output Blue 3 E2B-S08@-@-C@ Non-sensing zone Sensing zone Proximity Sensor M8 connector (3 pin) Pin Arrangement Sensing object (%) 100 0 4 Rated sensing distance NC 3 1 ON OFF Yellow indicator ON OFF Non-sensing zone Sensing zone Control output Proximity Sensor Sensing object (%) 100 Brown 1 0 Rated sensing distance NO Load ON OFF ON OFF Yellow indicator main circuits Black 4 or 2 Control output Blue 3 E2B-M12@-@-C@ E2B-M18@-@-C@ E2B-M30@-@-C@ 4 : NO 2 : NC Non-sensing zone Sensing zone Proximity Sensor Sensing object (%) 100 M12 Connector (4 pin) Pin Arrangement 0 1 Rated sensing distance NC 10 to 30 VDC 2 4 3 ON OFF Yellow indicator ON OFF Control output 13 E2B Dimensions Note: All units are in millimeters unless otherwise indicated. M8 Size Pre-wired Models (Shielded) Short Body Pre-wired Models (Unshielded) E2B-S08KS01-WP-@@/E2B-S08KS02-WP-@@ E2B-S08KN02-WP-@@/E2B-S08KN04-WP-@@ 42 42 27 4 13 Operating indicator (yellow LED,4x90) 6 13 27 4 Operating indicator (yellow LED,4x90) 6.6 dia. M8xP1 Toothed washer 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section : 0.141 mm ; Two,clamping nuts M8xP1 Toothed washer insulator diameter : 0.85 mm) ; standard length : 2 m 4-dia. vinyl-insulated round cable with 3 conductors Two,clamping nuts (conductor cross section : 0.141 mm ; insulator diameter : 0.85 mm) ; standard length : 2 m Long Body E2B-S08LS01-WP-@@/E2B-S08LS02-WP-@@ E2B-S08LN02-WP-@@/E2B-S08LN04-WP-@@ 64 64 49 49 4 13 Operating indicator (yellow LED,4x90) 6 13 Operating indicator (yellow LED,4x90) 4 6.6 dia. M8xP1 Toothed washer Two,clamping nuts 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section : 0.141 mm ; insulator diameter : 0.85 mm) ; standard length : 2 m Connector Models (Shielded) Short Body 4-dia. vinyl-insulated round cable with 3 conductors M8xP1 Toothed washer (conductor cross section : 0.141 mm ; Two,clamping nuts insulator diameter : 0.85 mm) ; standard length : 2 m Connector Models (Unshielded) E2B-S08KS01-MC-@@/E2B-S08KS02-MC-@@ E2B-S08KN02-MC-@@/E2B-S08KN04-MC-@@ 44 44 27 4 13 Operating indicator (yellow LED,4x90) 27 4 6 13 Operating indicator (yellow LED,4x90) 6.6 dia. M8xP1 M8xP1 Two,clamping nuts Toothed washer M8xP1 M8xP1 Two,clamping nuts Toothed washer Long Body E2B-S08LS01-MC-@@/E2B-S08LS02-MC-@@ E2B-S08LN02-MC-@@/E2B-S08LN04-MC-@@ 66 66 49 49 4 13 Operating indicator (yellow LED,4x90) 6 13 4 Operating indicator (yellow LED,4x90) 6.6 dia. M8xP1 M8xP1 Two,clamping nuts Toothed washer M8xP1 M8xP1 Two,clamping nuts Toothed washer Mounting Hole Cutout Dimensions External diameter Dimension F (mm) Dimension G (mm) of Proximity Sensor M8 8.5 dia.+0.5 13 0 F 14 G E2B M12 Size Pre-wired Models (Shielded) Short Body Pre-wired Models (Unshielded) E2B-M12KS02-WP-@@/E2B-M12KS04-WP-@@ 47 E2B-M12KN05-WP-@@/E2B-M12KN08-WP-@@ 47 7.9 30 30 4 17 17 Operating indicator (yellow) 7.9 4 7 Operating indicator (yellow) 10.5 dia. M12xP1 Two,clamping nuts Toothed washer M12xP1 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section : 0.141 mm ; insulator diameter : 0.85 mm) ; standard length : 2 m 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section : 0.141 mm ; insulator diameter : 0.85 mm) ; standard length : 2 m Two,clamping nuts Toothed washer Long Body E2B-M12LS02-WP-@@/E2B-M12LS04-WP-@@ 70 70 7.9 53 17 E2B-M12LN05-WP-@@/E2B-M12LN08-WP-@@ Operating indicator (yellow) 4 7.9 53 17 4 7 Operating indicator (yellow) 10.5 dia. M12xP1 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section : 0.141 mm ; insulator diameter : 0.85 mm) ; standard length : 2 m Two,clamping nuts Toothed washer Connector Models (Shielded) Short Body M12xP1 Two,clamping nuts Toothed washer Connector Models (Unshielded) E2B-M12KS02-M1-@@/E2B-M12KS04-M1-@@ E2B-M12KN05-M1-@@/E2B-M12KN08-M1-@@ 51 51 31 17 4 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section : 0.141 mm ; insulator diameter : 0.85 mm) ; standard length : 2 m 31 Operating indicator (yellow LED 4x90) 17 4 7 Operating indicator (yellow LED 4x90) 10.5 dia. M12xP1 M12xP1 Two,clamping nuts M12xP1 Toothed washer Toothed washer M12xP1 Two,clamping nuts Long Body E2B-M12LS02-M1-@@/E2B-M12LS04-M1-@@ E2B-M12LN05-M1-@@/E2B-M12LN08-M1-@@ 74 74 54 17 4 54 Operating indicator (yellow LED 4x90) 17 7 4 Operating indicator (yellow LED 4x90) 10.5 dia. M12xP1 Two,clamping nuts Toothed washer M12xP1 M12xP1 Toothed washer M12xP1 Two,clamping nuts Mounting Hole Cutout Dimensions External diameter Dimension F (mm) Dimension G (mm) of Proximity Sensor M12 12.5 dia.+0.5 17 0 F G 15 E2B M18 Size Pre-wired Models (Shielded) Short Body Pre-wired Models (Unshielded) E2B-M18KS05-WP-@@/E2B-M18KS08-WP-@@ E2B-M18KN10-WP-@@/E2B-M18KN16-WP-@@ 56 56 36 24 36 5.6 Operating indicator (yellow) 4 24 5.6 4 10 Operating indicator (yellow) 16.4 dia. M18xP1 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section : 0.141 mm ; insulator diameter : 0.85 mm) ; standard length : 2 m Toothed washer M18xP1 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section : 0.141 mm ; insulator diameter : 0.85 mm) ; standard length : 2 m Toothed washer Two,clamping nuts Two,clamping nuts Long Body E2B-M18LS05-WP-@@/E2B-M18LS08-WP-@@ E2B-M18LN10-WP-@@/E2B-M18LN16-WP-@@ 78 78 58 24 58 4 5.6 Operating indicator (yellow) 4 24 10 5.6 Operating indicator (yellow) 16.4 dia. M18xP1 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section : 0.141 mm ; insulator diameter : 0.85 mm) ; standard length : 2 m Two,clamping nuts M18xP1 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section : 0.141 mm ; insulator diameter : 0.85 mm) ; standard length : 2 m Two,clamping nuts Toothed washer Toothed washer Connector Models (Shielded) Short Body Connector Models (Unshielded) E2B-M18KS05-M1-@@/E2B-M18KS08-M1-@@ E2B-M18KN10-M1-@@/E2B-M18KN16-M1-@@ 59 59 39 39 24 Operating indicator (yellow LED 4x90) 4 10 24 Operating indicator (yellow LED 4x90) 4 10 16.4 dia. M12xP1 M18xP1 M12xP1 M18xP1 Two,clamping nuts Toothed washer Two,clamping nuts Toothed washer Long Body E2B-M18LS05-M1-@@/E2B-M18LS08-M1-@@ E2B-M18LN10-M1-@@/E2B-M18LN16-M1-@@ 81 81 61 4 24 Operating indicator (yellow LED 4x90) 24 10 61 4 Operating indicator (yellow LED 4x90) 16.4 dia. M12xP1 M18xP1 M18xP1 Two,clamping nuts Toothed washer M12xP1 Two,clamping nuts Toothed washer Mounting Hole Cutout Dimensions External diameter Dimension F (mm) Dimension G (mm) of Proximity Sensor M18 18.5 dia.+0.5 24 0 F 16 G E2B M30 Size Pre-wired Models (Shielded) Short Body Pre-wired Models (Unshielded) E2B-M30KS10-WP-@@/E2B-M30KS15-WP-@@ 60 60 6.1 41 5 36 E2B-M30KN20-WP-@@ 6.1 41 36 5 15 Operating indicator (yellow) Operating indicator (yellow) 27.8 dia. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section : 0.141 mm ; insulator diameter : 0.85 mm) ; standard length : 2 m Toothed washer 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section : 0.141 mm ; M30xP1.5 M30xP1.5 insulator diameter : 0.85 mm) ; standard length : 2 m Two,clamping nuts Toothed washer Two,clamping nuts Long Body E2B-M30LS10-WP-@@/E2B-M30LS15-WP-@@ 82 82 6.1 63 36 E2B-M30LN20-WP-@@/E2B-M30LN30-WP-@@ Operating indicator (yellow) 5 6.1 63 5 36 Operating indicator (yellow) 15 27.8 dia. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section : 0.141 mm ; insulator diameter : 0.85 mm) ; standard length : 2 m M30xP1.5 Two,clamping nuts M30xP1.5 Two,clamping nuts Toothed washer Connector Models (Shielded) Short Body 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section : 0.141 mm ; insulator diameter : 0.85 mm) ; standard length : 2 m Toothed washer Connector Models (Unshielded) E2B-M30KS10-M1-@@/E2B-M30KS15-M1-@@ E2B-M30KN20-M1-@@ 64 64 Operating indicator (yellow LED 4x90) 44 5 36 Operating indicator (yellow LED 4x90) 44 36 5 15 27.8 dia. M12xP1 M12xP1 M30xP1.5 Toothed washer M30xP1.5 Two,clamping nuts Toothed washer Two,clamping nuts Long Body E2B-M30LS10-M1-@@/E2B-M30LS15-M1-@@ E2B-M30LN20-M1-@@/E2B-M30LN30-M1-@@ 86 86 Operating indicator (yellow LED 4x90) 66 36 5 66 5 36 Operating indicator (yellow LED 4x90) 15 27.8 dia. M12xP1 M12xP1 M30xP1.5 Toothed washer M30xP1.5 Two,clamping nuts Toothed washer Two,clamping nuts Mounting Hole Cutout Dimensions External diameter Dimension F (mm) Dimension G (mm) of Proximity Sensor M30 30.5 dia.+0.5 36 0 F G 17 E2B Accessories (Order Separately) Sensor I/O Connectors M8 Connector (3 pin) PVC Type (Unit: mm) Straight XS3F-M8PVC3S2M (L = 2 m) XS3F-M8PVC3S5M (L = 5 m) L(Cable length) M8xP1 31.9 21.5 4 3 1 5 dia. 9 dia. 5 30 Model Right-angle XS3F-M8PVC3A2M (L = 2 m) XS3F-M8PVC3A5M (L = 5 m) 50 Lot No. L(Cable length) 5 dia. 23.1 5 21 30 Model 50 Lot No. 9 dia. 1 4 3 M8xP1 PVC Robot Type Straight XS3F-M321-302-R (L = 2 m) XS3F-M321-305-R (L = 5 m) M8xP1 4 dia. 4 3 1 9 dia. 21.5 30 31.4 Right-angle XS3F-M322-302-R (L = 2 m) XS3F-M322-305-R (L = 5 m) 30 20.5 4 dia. 9 dia. 1 4 3 M8xP1 Pin arrangement 4 3 18 1 1-Brown 3-Blue 4-Black 50 L (Cable length) 23.1 5 50 L (Cable length) 5 E2B Sensor I/O Connectors M12 Connector (4 pin) PVC Type Straight XS2F-M12PVC4S2M (L = 2 m) XS2F-M12PVC4S5M (L = 5 m) L(Cable length) 40.7 1 2 4 3 5 dia. Model 14.9 dia. 5 30 Lot No. M12 x P1 Right-angle XS2F-M12PVC4A2M (L = 2 m) XS2F-M12PVC4A5M (L = 5 m) 50 L(Cable length) 25.3 5 dia. Model 5 30 28.3 Lot No. 50 14.9 dia. 3 2 M12 x P1 4 1 PVC Robot Type Straight XS2F-D421-D80-F (L = 2 m) XS2F-D421-G80-F (L = 5 m) M12xP1 1 2 4 3 6 dia. 14.9 dia. 30 40.7 L (Cable length) Right-angle XS2F-D422-D80-F (L = 2 m) XS2F-D422-G80-F (L = 5 m) 50 L (Cable length) 30 25.3 5 50 5 28.3 6 dia. 14.9 dia. 3 2 4 1 M12xP1 Pin arrangement 1 4 2 3 1-Brown 2-White 3-Blue 4-Black 19 E2B Precautions Wiring WARNING Be sure to wire the E2B and load correctly, otherwise it may be damaged. This product is not designed or rated for ensuring safety of persons. Do not use it for such purpose. Connection with No Load Be sure to insert loads when wiring. Make sure to connect a proper load to the E2B in operation, otherwise it may damage internal elements. Never use this product with an AC power supply. Otherwise, explosion may result. Do not expose the product to flammable or explosive gases. Do not disassemble, repair, or modify the product. Safety Precautions Load Short-circuit Do not short-circuit the load, or the E2B may be damaged. The E2B's short-circuit protection function will be valid if the polarity of the supply voltage imposed is correct and within the rated voltage range. When provided with the UL Listing Mark, the E2B series with M1 or MC suffix shall be used with a Listed cable/connector assembly rated minimum 30V, minimum 200mA, in the final installation. Correct Use Designing Power Reset Time The Proximity Sensor is ready to operate within 100 ms after power is supplied. If power supplies are connected to the Proximity Sensor and load respectively, be sure to supply power to the Proximity Sensor before supplying power to the load. Effects of Surrounding Metal When mounting the proximity sensor within a metal panel, ensure that the clearances given in the Table1 are maintained. Failure to maintain these distance may cause deterioration in the performance of the sensor. Table 1 Single Sensing Distance Type l l n m d dia. D m n m d dia. D m l l (Unit: mm) Item l d D m n Size M8 M12 M18 0 8 0 4.5 12 0 12 0 8 18 M30 0 18 0 20 27 0 30 0 40 45 Double Sensing Distance Type (Unit: mm) Item l d D m n Size M8 M12 6 24 6 8 24 M18 15 40 15 20 36 M30 22 55 22 40 54 l l n m d dia. D m n m d dia. D m l l (Unit: mm) Item l d D m n 20 30 90 30 70 90 Size M8 M12 0 8 0 4.5 12 M18 2.4 18 2.4 12 18 M30 3.6 27 3.6 24 27 6 45 6 45 45 (Unit: mm) Item l d D m n Size M8 M12 12 24 12 8 24 M18 15 40 15 20 40 M30 25 70 25 48 70 45 140 45 90 140 E2B Power OFF The Proximity Sensor may output a pulse signal when it is turned OFF. Therefore,it is recommended that the load be turned OFF before turning OFF the Proximity Sensor. Power Supply Transformer When using a DC power supply, make sure that the DC power supply has an insulated transformer. Do not use a DC power supply with an auto-transformer. Mutual Interference When installing two or more proximity sensors face to face or side by side, ensure that the minimum distances given in the Table2 are maintained. Table 2 Unit: (mm) Size M8 M12 M18 M30 Type Shielded Unshielded Shielded Unshielded Shielded Unshielded Shielded Unshielded Model S08@S01 S08@S02 S08@N02 S08@N04 M12@S02 M12@S04 M12@N05 M12@N08 M18@S05 M18@S08 M18@N10 M18@N16 M30@S10 M30@S15 M30@N20 M30@N30 E2B-( ) A 20 20 80 80 30 30 120 120 50 60 200 200 100 110 300 350 B 15 15 60 60 20 20 100 100 35 35 110 120 70 90 200 300 Wiring High-tension Lines Maintenance and Inspection Wiring through Metal Conduit: If there is a power or high-tension line near the cable of the Proximity Sensor, wire the cable through an independent metal conduit to prevent against Proximity Sensor damage or malfunctioning. Cable Extension Standard cable length is less than 200 m. The tractive force is 50 N. Mounting Do not tighten the sensor mounting nuts with excessive force. Table 3 (Shielded) (Unshielded) Size M8 M12 M18 M30 Torque 7 N*m 12 N*m 30 N*m 50 N*m Periodically perform the following checks to ensure stable operation of the Proximity Sensor over a long period of time. 1. Check for mounting position, dislocation, looseness, or distortion of the Proximity Sensor and sensing objects. 2. Check for loose wiring and connections, improper contacts, and line breakage. 3. Check for attachment or accumulation of metal powder or dust. 4. Check for abnormal temperature conditions and other environmental conditions. 5. Check for proper lighting of indicators (for models with a set indicator.) Never disassemble or repair the Sensor. Environment Water Resistivity The Proximity Sensors are tested intensively on water resistance, but in order to ensure maximum performance and life expectancy avoid immersion in water and provide protection from rain or snow. Operating Environment Ensure storage and operation of the Proximity Sensor within the given specifications. Inrush Current A load that has a large inrush current (e.g., a lamp or motor) will damage the Proximity Sensor, in which case connect the load to the Proximity Sensor through a relay. OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of the products in the customer's application or use of the products. Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will be used. Product specifications and accessories may be changed at any time based on improvements and other reasons. Consult with your OMRON representative at any time to confirm actual specifications of purchased product. 21 READ AND UNDERSTAND THIS DOCUMENT Please read and understand this document before using the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. SUITABILITY FOR USE THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT SAFETY RATED. THEY ARE NOT DESIGNED OR RATED FOR ENSURING SAFETY OF PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES. Please refer to separate catalogs for OMRON's safety rated products. OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the product. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: * Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document. * Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. * Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PERFORMANCE DATA Performance data given in this document is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. COPYRIGHT AND COPY PERMISSION This document shall not be copied for sales or promotions without permission. This document is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or reproducing this document in any manner, for any other purpose. If copying or transmitting this document to another, please copy or transmit it in its entirety. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. OMRON Corporation Industrial Automation Company Authorized Distributor: Tokyo, JAPAN Contact: www.ia.omron.com Regional Headquarters OMRON EUROPE B.V. Sensor Business Unit Carl-Benz-Str. 4, D-71154 Nufringen, Germany Tel: (49) 7032-811-0/Fax: (49) 7032-811-199 OMRON ELECTRONICS LLC One Commerce Drive Schaumburg, IL 60173-5302 U.S.A. Tel: (1) 847-843-7900/Fax: (1) 847-843-7787 OMRON ASIA PACIFIC PTE. LTD. No. 438A Alexandra Road # 05-05/08 (Lobby 2), Alexandra Technopark, Singapore 119967 Tel: (65) 6835-3011/Fax: (65) 6835-2711 OMRON (CHINA) CO., LTD. Room 2211, Bank of China Tower, 200 Yin Cheng Zhong Road, PuDong New Area, Shanghai, 200120, China Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200 (c) OMRON Corporation 2013 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. Printed in Japan CSM_1_5_0314 Cat. No. D116-E1-02 0314(0413) Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: E2B-M30LN30-M1-C2 E2B-S08KS02-WP-C2 5M E2B-M18LN16-WP-C2 5M E2B-M18LS08-M1-C2 E2B-M12KN08WP-C2 5M E2B-M12LN08-M1-C2 E2B-M12LN08-WP-B2 5M E2B-M18KN16-M1-C2 E2B-M18KN16-WP-B2 5M E2BS08KN04-WP-C2 5M E2B-M12LS04-WP-C2 5M E2B-M30LS15-WP-C2 5M E2B-S08LS02-WP-B2 5M E2B-S08KS02MC-C2 E2B-M30KS15-M1-C2 E2B-M30LN30-WP-B2 5M E2B-M18KN16-WP-C2 5M E2B-M18LN16-WP-B2 2M E2B-M12KN08-WP-B2 2M E2B-M12LS04-WP-C2 2M E2B-M30LN30-WP-B2 2M E2B-M18LN16-M1-C1 E2BS08KN04-MC-C1 E2B-M30LN30-M1-C1 E2B-M12LS04-WP-B2 5M E2B-M18LN16-M1-C2 E2B-M30KS15-WP-C2 5M E2B-S08KN04-MC-C2 E2B-S08KS02-WP-B2 5M E2B-M12KS04-WP-C2 5M E2B-M30LS15-WP-B2 5M E2BS08LS02-WP-C2 5M E2B-M18LS08-WP-C2 5M E2B-M12KN08-M1-C2 E2B-M12LS04-M1-C2 E2B-M30LN30-WP-C2 5M E2B-S08LS02-MC-C2 E2B-M18KS08-M1-C2 E2B-M12KS04-M1-C2 E2B-M18KS08-WP-B2 5M E2B-M12KN08WP-B2 5M E2B-M12KS04-WP-B2 5M E2B-M18LS08-WP-B2 5M E2B-M30KS15-WP-B2 5M E2B-M18KS08-WP-C2 5M E2B-S08LN04-MC-C2 E2B-M30LS15-M1-C2 E2B-S08LN04-WP-B2 5M E2B-M18LN16-WP-B2 5M E2BS08LN04-WP-C2 5M E2B-M12LN08-WP-C2 5M E2B-S08KN04-WP-B2 5M E2B-M12LN08-WP-B1 2M E2BM18KN16-WP-B1 2M E2B-M12LN08-M1-B1 E2B-M18KS08-WP-C1 2M E2B-M18LS08-M1-B1 E2B-M30LS15-WP-B1 2M E2B-M12KS04-WP-C1 2M E2B-S08LN04-WP-C1 2M E2B-M18KN16-WP-C1 5M E2B-M18KS08-M1-B2 E2BM12KN08-WP-B1 5M E2B-M12KS04-WP-C1 5M E2B-M30LS15-WP-B1 5M E2B-S08LS02-WP-C1 5M E2BM12LS04-WP-B1 5M E2B-M18KN16-M1-C1 E2B-M18KN16-WP-B2 2M E2B-M18LS08-M1-C1 E2B-M12LN08-WP-C2 2M E2B-S08KN04-WP-B2 2M E2B-S08KS02-WP-B2 2M E2B-M30KS15-WP-C2 2M E2B-S08LS02-WP-C1 2M E2BM12LN08-WP-C1 2M E2B-S08KN04-WP-B1 2M E2B-S08KS02-WP-B1 2M E2B-M18KN16-M1-B1 E2B-M30KS15WP-C1 2M E2B-M18KN16-WP-C1 2M E2B-M18KS08-WP-B1 2M E2B-S08KN04-MC-B2 E2B-M30KS15-WP-C1 5M E2B-M30LN30-M1-B2 E2B-S08KS02-WP-B1 5M E2B-M18LN16-WP-B1 5M E2B-S08LN04-WP-C1 5M E2BM30KS15-M1-B1 E2B-M30LS15-M1-B1 E2B-S08LN04-MC-B1 E2B-M12KS04-WP-B1 2M E2B-M30LN30-WP-C1 2M E2B-S08KS02-MC-B1 E2B-M30LS15-WP-C1 5M E2B-S08KS02-MC-B2 E2B-S08LS02-WP-B1 5M E2B-M12LS04WP-C1 5M E2B-S08LN04-MC-B2 E2B-S08LN04-WP-B1 5M