Bussmann
Solutions for the Transportation Industry
Circuit Protection • Power Distribution • Wiring Accessories
TRANSPORTATION PRODUCTS
Contents
Page
Custom Solutions for Power Distribution 1
SERIES 31000/32000
Vehicle Electrical Centers 2-3
Vehicle Electrical Center Connectors 4
Vehicle Electrical Center Accessories 5
SERIES 15300 RTMR
Rear Terminal Mini Fuse & Relay Panels 6-7
SERIES 37700 PRM/PFM
Power Relay Module/Power Fuse Module 8-9
SERIES 15710 RTA
Rear Terminal ATC®Fuse Block 10
SERIES 15600
ATC®Blade-Type Fuse Panels 11
HMG
Automotive Bolt-In Fuseholder for the AMG Fuse 12
FMG
Automotive Bolt-In Fuseholder for the AMG Fuse 13
Inline Fuseholders 14
SERIES 15250
Battery Disconnect Switch 15
Stud Type Junction Blocks 16
Stud Type Junction Blocks
(Non-Feed-Thru) 17
Basic Overcurrent Technology 18-19
MINI Blade Fuses 20
SERIES 21X MINI Circuit Breakers 21
ATC ®Blade Fuses 22
SERIES 22X ATC®Circuit Breakers 23
SERIES 227 ATC®Circuit Breakers (Low Profile) 24
MAXI®Blade Fuses 25
SERIES 19X MAXI®Circuit Breakers 26
SERIES 3200/32013
Insertion/Extraction Tool 27
SERIES 174 FLAT-PAK
Manual Reset Circuit Breakers 28-29
SERIES 12X SHORTSTOP®
Auto, Manual & Modified Reset Circuit Breakers 30
SERIES 25X MID-RANGE
Auto, Manual Reset, & Manual Reset
w/ Push-to-Trip Circuit Breakers 31
SERIES 18X HI-AMP
Auto, Manual Reset & Switchable Circuit Breakers 32
SERIES 187 MRCB
Switchable Circuit Breakers 33
AMI SERIES
Bolt In Automotive Fuses 34
AMG SERIES
Bolt In Automotive Fuses 35
NOTES 36-37
1
Custom Solutions For Power Distribution
Cooper Bussmann plays a key role in developing custom solutions for vehicle power distribution applications.
Once a product need is identified, an innovative team of design engineers works closely with the customer to
discuss their needs. This enables our team to design and develop custom solutions tailored to meet specific
customer requirements.
Many custom solutions include developing linkage systems to join two or more of our products together. This
allows the customer “one-stop shopping” to create their vehicle electrical system. Other examples include
bussing/jumpering, color-coding, and changing thread sizes.
If you are in need of a custom solution, please contact your Bussmann sales representative for assistance.
Bussmann®VEHICLE ELECTRICAL CENTERS
2
SERIES 31000/32000 VEHICLE ELECTRICAL CENTERS
Cooper Bussmann’s Single Vehicle Electrical Center
(VEC) and Dual Vehicle Electrical Center (DVEC) are
widely used Transportation Industry power distribution
modules. The VEC & DVEC use patented programmable
3D matrix technologies that can be easily modified to
accommodate changes to an electrical system. These can
be customized for each specific electrical system, but
require no tooling for implementation.
The VEC & DVEC accept automotive components includ-
ing fuses, relays, circuit breakers, diodes, and other
devices that have 2.8mm wide terminals on 8.1mm center-
line spacing. (See page 5 for additional available compo-
nents.) The compact size of the VEC (about 4”x4”) and
larger size of the DVEC (approximately 8”x4”) provide for
high component density. VEC’s provide either 8.0mm
bladed inputs or M8/M6 stud inputs. The VEC can accom-
modate up to 2 input connectors - 4 bladed inputs or 2
studs - and 4 output connectors. The DVEC can accommo-
date up to twice this amount. (Some designs may limit the
number of connectors available for use.)
APPLICATIONS
The VEC/DVEC is ideal for distributed main power as well
as auxiliary “add-on” applications. Current VEC/DVEC
applications include Class 3-8 trucks, buses, chassis and
RV, Con-Ag equipment, marine specialty vehicles, and
automotive power distribution systems.
BENEFITS
The customizable designs of the VEC/DVEC enable them
to incorporate many different devices and multiple design
variations. Splices in the harness can also be eliminated by
internally programming them into the grid matrix. The
inputs (connector or stud) and outputs (connector) of the
VEC/DVEC are color-coded and keyed, and provide quick
installation. This makes the module easy to service. The
largest benefit of these modules are the reduced lead
times and zero tooling cost.
Transparent cover
for illustration
purposes only.
SPECIFICATIONS
Input Terminal Rating: 8.0mm blade terminals (60A max
per terminal); M8/M6 input studs (100A max per terminal).
200A max total for VEC, 400A max total for DVEC.
Output Terminal Rating: 2.8mm blade terminals (30A
max per terminal).
Temperature Rating: –40°F (–40°C) to 260°F (125°C).
Materials: Thermoplastic housing and connectors;
Tin-plated copper internal grid.
Termination: Delphi Packard Metri-Pack®280 Series
terminals (sealed/unsealed & tanged/tangless) or AMP®
terminals.* Delphi Packard 280 Series cavity plugs are
installed where wires are not used.* Accepts #10-22 AWG
wire sizes.
Mounting Torque Rating: 24in-lb (2.7Nm) max.
Mounting Orientation: Unit cannot be installed upside-
down. Consult factory for proper mounting orientations.
Ingress Protection Rating: IP55.
OPTIONS
Cover: Vented (VEC), Solid with gasket (VEC/DVEC),
Solid without gasket (DVEC), or none provided.
Cover Label: Inside cover, outside cover (VEC only), or
none provided.
Input Style: 8.0mm blade terminals or studs (M8/M6).
Mounting: External feet with mounting holes (VEC/DVEC)
or internal mounting holes (VEC only).
Components: Fuse, breaker, relay, etc. installation to be
specified by customer.
Severe Service: Added environmental protection avail-
able. Consult factory.
Fuse/breaker Extraction Tool: See page 27.
Each design is customer specific. Consult your
sales rep today for your application.
*Electrical terminals, cable seals & cavity
plugs are NOT supplied by
Cooper Bussmann.
Cooper Bussmann Transportation Products • Phone: 1-888-867-8194 • Website: http://www.coopertp.com
Bussmann®VEHICLE ELECTRICAL CENTERS
3
SERIES 31000/32000 VEHICLE ELECTRICAL CENTERS
4X #10 INTERNAL
MOUNTING HOLES
MOUNTING TORQUE
RECOMMENDATIONS
6.56[.26] OPTIONAL
EXTERNAL MOUNTING FEET
(CONSULT FACTORY)
BUILT IN DRAINAGE
106.6"
[4.20]
REF.
73.00"
[2.87]
73.00"
[2.87]
106.6"
[4.20]
REF.
I/O #5I/O #6
I/O #4
I/O #3
I/O #2
CONNECTOR #1
INPUT/OUTPUT
SPLASHPROOF
ASSEMBLY
OPTIONAL COVER
(SPLASHPROOF &
VENTED VERSIONS)
CONNECTOR LOCK
69.64"
[2.74]
REF.
1.90"
[.07]
REF.
22.49"
[.89]
REF.
15.23"
[.60]
REF.
146.59"
[5.77]
REF.
108.86"
[4.29]
REF.
DIMENSIONS 31000 SERIES VEC (Dims. shown are for reference only. Consult factory for latest prints)
TYP. 3
Mounting Holes
ø6.5"
(0.26)
Shown Without Cover
or Components
79.4"
(3.3)
(excluding text
height on cover)
49.4"
(1.95)
ø6.5"
(0.26)
197.6"
(7.78)
Optional
Stud Cover
Optional
Cover
111.4"
(4.39)
106.4"
(4.2)
160.8"
(6.3) 146.5"
(5.8)
229.7"
(9.0)
I/O #4 I/O #3
I/O #2
I/O #1
I/O #12
I/O #11
I/O #9 I/O #10
I/O #8
I/O #7
I/O #6
I/O #5
DIMENSIONS 32000 SERIES DVEC (Dims. shown are for reference only. Consult factory for latest prints)
Terminal position assurance
32004-TPX
Seal
Male Input Connector
32004-xx
Female Terminal*
Delphi Packard 800
Metri-Pack® series
shown Cable seal
Delphi Packard #12129381r
shown
Terminal position assurance
32006-TPX
Seal
Male Output Connector
32006-xxx
Female Terminal*
Delphi Packard 280
Metri-Pack® series
shown
Cable Seal
Delphi Packard 280
Metri-Pack® series
shown
Bussmann®VEHICLE ELECTRICAL CENTER CONNECTORS
4Cooper Bussmann Transportation Products • Phone: 1-888-867-8194 • Website: http://www.coopertp.com
VEHICLE ELECTRICAL CENTER CONNECTORS
26.8
(1.06)
30.3
(1.19)
46.2
(1.82)
Connector Polarized
(Consult Factory For Details)
32004-CP Shown
Assembled
In-Place
32004-CP Shown
Prior To Engagement
VEC Female Input Connector
(Shown For Reference Only)
Male Input
Connector
Assembly
HGF
BCD
24.4
(0.96)
26.3
(1.04) 17.9
(0.71)
39.9
(1.57)
30.8
(1.21)
Connector Polarizer
(Consult Factory for Details)
TERMINAL POSITION ASSURANCE
32006 - TPX
Sealed / Non-Sealed Configuration
1= Non-Sealed Version
2= Sealed Version
MALE INPUT CONNECTOR
32004 - X X
Sealed / Non-Sealed Configuration
1= Non-Sealed Version
2= Sealed Version
Color of Part
A= Black
B= Gray
TERMINAL POSITION ASSURANCE
32004 -TPX
CONNECTOR POSITION ASSURANCE
32004 - CP (Ship in Bulk)
Sealed / Non-Sealed Configuration
1= Non-Sealed Version
2= Sealed Version
CONNECTOR POSITION ASSURANCE
32006 - CP (Ship in Bulk)
Note: Terminals and Terminal Seal
Components are not provided with connectors.
Available from Delphi Packard. Contact factory
for part list and terminal removal tool. Sealed
connector option includes outer body seal.
Note: Terminals and Terminal Seal
Components are not provided with connectors.
Available from Delphi Packard. Contact factory
for part list and terminal removal tool. Sealed
connector option includes outer body seal.
Male Output Connector Assembly
VEC Female Output Connector
(Shown For Reference Only)
32006-CP
Shown
Assembled
In-Place
32006-CP
Shown
Prior To
Engagement
Sealed / Non-Sealed Configuration
1= Non-Sealed Version
2= Sealed Version
Connector Cavity Configuration
1= Tang-less Female Connector (Delphi 280)
2= with Tang Female Connector (Delphi 280)
3= AMP®
P= all cavities plugged
Color of Part
A= Black E= Yellow
B= Gray F= Red
C= Green G= Orange
D= Blue H= Brown
J= Neutral (only available for -JP2 option)
MALE OUTPUT CONNECTOR
32006 - X X X
(Dims.shown are for reference only. Consult factory for latest prints)
(Dims.shown are for reference only. Consult factory for latest prints)
OPTIONAL
"WING"
FOR ADDITIONAL
DIODE KEYING
STANDARD
DIODE KEY
DIODE MARKING
SHOWN
][0.0902.29
][0.91
23.0
][0.36
9.2
][0.30
7.6
][0.35
8.9
][1.07
27.3
][0.25
6.4
][
0.48
12.2
][0.153.8
][0.030.8
][0.112.8
][8.13
.32
22901 Series
Transorb
22902 Series
Resistor
22903 Series
Diode
Cooper Bussmann Transportation Products • Phone: 1-888-867-8194 • Website: http://www.coopertp.com
Bussmann®VEC ACCESSORIES
5
ELECTRICAL COMPONENTS
Series 229 Diode, Resistor, and Transorb
SPECIFICATIONS (Dims. shown are for reference only. Consult factory for latest prints)
Ratings: Consult Factory for Available Ratings and part numbers
Materials: Grey 94V-0 thermoplastic housing with metal cover.
Termination Type: Compatible with 280 Type fuse blocks using 8.1mm
centerline.
Diode Key Feature: Standard key denotes installation direction.
Extended key available for error-proof installation in VEC.
VEC ACCESSORIES
Series 32016
(Terminal Seals) &
Series 32017
(Cavity Plugs)
Used in conjunction with
the VEC input connector
(Series 32004), terminal
seals provide a sealed fit
between the wire terminals
and connector. Cavity
plugs can be used to seal
unused terminal positions.
Series 32011 (Input Connector Cap) &
Series 32012 (Output Connector Cap)
Connector caps can be assembled to the mating VEC harness
connectors (Series 32004 & 32006) when not in use.
Series 32018
(for use with Series 32000 DVEC)
External bus bar can be used with the Dual VEC to
bus together studded power inputs.
DVEC Cover Tether
Tether available for use with
Series 32000 DVEC cover.
Consult factory.
Relays (Only Available for VEC, DVEC, or RTMR Applications.)
SPECIFICATIONS
Types: 5-pin mini-relay, 12 VDC & 24 VDC
5-pin micro-relay, 12 VDC & 24 VDC
4-pin mini-micro relay, 12 VDC
Consult Factory for Available Amperage Ratings
Termination Type: Compatible with 280 Type fuse
blocks using 8.1mm centerline.
Sealed versions of some relays also available.
Bussmann®MINI-TERMINAL POWER DISTRIBUTION MODULE
6Cooper Bussmann Transportation Products • Phone: 1-888-867-8194 • Website: http://www.coopertp.com
SERIES 15300 RTMR
The Rear Terminal Mini Fuse and Relay panel (RTMR)
provides efficient power distribution in a rugged compact
form for applications in marine, construction, agriculture,
heavy trucking, specialty vehicles, etc. This innovative
product offers a weather tight enclosure (IP66/67)for
various MINI (2.8mm) blade components when cover,
cable seals, and cavity plugs are installed. It is available
with various degrees of internal electrical bussing.
Additionally, custom labels and multiple hardware configu-
rations are available to solve any application need.
SPECIFICATIONS
Input Terminal Rating: M6 input studs on bussed/partially
bussed inputs: 80A max input on bussed fuse side, 80A
max input on bussed relay side.
Output Terminal Rating: 2.8mm blade terminals (30A
max per terminal)
Temperature Rating: –40°F (–40°C) to 260°F (125°C).
Materials: Black thermoplastic housing; Tin-plated copper
internal bussing; Bright nickel-plated brass studs (on
bussed versions).
Termination: Delphi Packard Metri-Pack®280 Series ter-
minals (sealed/tangless) or AMP®terminals.* Delphi
Packard 280 Series cavity plugs are installed where wires
are not used.* Accepts #12-22 AWG wire sizes.
Torque Rating: 75in-lb (8.5Nm) max.
Mounting Torque Rating: #10-32 or M5 threaded inserts;
24in-lb (2.7Nm) max torque.
Ingress Protection Rating: IP66-IEC 60529 (Valid when
properly installed with cover, sealed terminals, and cavity
plugs.) IP67 (Same requirements as IP66, but also needs a
periodic - 3-9 months - coating of silicone lubricant applied
to green base seal.)
OPTIONS
End Caps: Protective silicone end caps available for stud-
ded versions.
Mounting: Mounting brackets available for surface-mount-
ing RTMR. (See page 7.)
Labels: Consult factory for custom label options.
Replacement Accessories: Consult factory for available
service parts.
*Electrical terminals, cable seals & cavity plugs are
NOT supplied by Cooper Bussmann.
IP66/67 Rated
Rear Terminal Mini Fuse & Relay
Power Distribution Module
Series
❏❏❏❏
1 5 3 0
Mounting
1 – #10-32
threaded
insert
2 – M5x0.8
threaded
insert
Cooper Bussmann Transportation Products • Phone: 1-888-867-8194 • Website: http://www.coopertp.com
Bussmann®MINI-TERMINAL POWER DISTRIBUTION MODULE
7
SERIES 15300 RTMR
DIMENSIONS (Dims. shown are for reference only. Consult factory for latest prints)
RELAY
SIDE RELAY
SIDE RELAY
SIDE
CB SIDE
FUSE/
FUSE/
15301-315301-2 BOTTOM VIEW OF
15301-2 & -3
TOP VIEW OF
SHOWN HERE (15301-4)
NON-BUSSED VERSION
STUDS INSTALLED ONLY
ON BUSSED SIDES. (15301-1 SHOWN HERE)
CB SIDE FUSE/
CB SIDE
15301-4, -5 & -6
BOTTOM VIEW OF 15301-1
15301-1
15301-615301-4 15301-5
THREADED INSERT
52.7
[2.1]
RELAY/CB
COVER
62.8
[2.5]
102.8
[4.0]
112.8
[4.4]
86.0
[3.4]
33.5
[1.3]
FUSE
COVER
75.0
[3.0]
90.6
[3.6]
PART NUMBERING SYSTEM
Base
1 – Fuse / C.B. Base
20 Fuse Positions
(10 on each side)
2 – Micro Relay Base
5 Micro Relays with 10 Fuses / C.B.
3 – Mini Relay Base
3 Mini (or Micro) Relays with 10 Fuses / C.B.
4 – Non Bussed Version
3 Mini or 5 Micro Relays and 10 Fuses/C.B.
5 – Partially Bussed Version
3 Unbussed Mini or 5 Unbussed Micro Relays
and 10 Bussed Fuses/C.B.
6 – Partially Bussed Version
3 Bussed Mini or 5 Bussed Micro Relays
and 10 Unbussed Fuses/C.B.
Hardware
0 – No nuts
1 – Nuts (bulk)
2 – Nuts
(assembled)
3 – No nuts, end
caps ( bulk)
4 – No nuts,
end caps
(assembled)
5 – Nuts and end
caps (in bulk)
6 – Nuts and
end caps
(assembled)
Terminal Cavity
Blank – Standard
Delphi 280
®
A – AMP
®
series
Cover
0 – No cover
1 – Fuse cover
2 – Relay / circuit
breaker
(C.B.) cover
Marking Options
Blank – Std. marking
(Consult factory for
special options.)
Mounting Brackets
❏❏❏❏ ❏❏❏❏
B 0 2 8 7 0 1 2
RTMR Stud End Cap
❏❏❏❏ ❏❏❏❏
B 0 6 6 7 0 0 8
Material
O – Plated steel
P – Stainless steel
RTMR OPTIONS
RTMR
Mounting Bracket
RTMR (STUD)
End cap/cover
Power Relay Module
Power Distribution Module & Fuse Block
Bussmann®POWER RELAY POWER DISTRIBUTION MODULE
8Cooper Bussmann Transportation Products • Phone: 1-888-867-8194 • Website: http://www.coopertp.com
SERIES 37700 PRM/PFM
PRM Rating: 70A, 12VDC steady-state relay; 24VDC relay
also available. Relay protection fuse: up to 60A; Non-
switched inline fuse: up to 60A.
PFM Rating: Each inline fuse rated up to 60A.
Temperature Rating: –40°F (–40°C) to 185°F (85°C).
Materials: UL-Rated 94V-0 thermoplastic (excluding cover;)
Silicone seal; Tin-plated copper terminals; Plated steel
studs.
Input Termination: M8 threaded stud. PRM
Switching/Trigger Signal: Delphi Packard Metri-Pack®150
Series; AMPSEAL®16.*
Output Termination Option: Bussmann Series 32004
sealed connector (see page 4); Accepts Delphi Packard 800
series terminals.* Two M6 threaded studs.
Torque Rating: Input stud: 144in-lb (16.3Nm) max.; Output
stud: 48in-lb (5.4Nm) max.
Mounting Torque Rating: 48in-lb (5.4Nm) max.
Ingress Protection Rating: IP66 (excluding stud connec-
tions)
OPTIONS
Mounting: Counter rotation feature (CRF) available to pre-
vent rotation on single bolt installations.
Bussing: Custom bussing available for joining multiple
PRMs/PFMs. Options also available for bussing
PRMs/PFMs to other Bussmann power distribution mod-
ules.
Accessories: Stud caps, separators, service components.
Consult factory for details.
*Electrical terminals are NOT supplied by Cooper
Bussmann.
PART NUMBERING SYSTEM
Series/
Module Type
❏❏❏❏❏
3 7 7 0 1
PFM
Output/Signal
Connector Type
1
Signal Key
(PRM only)
N
Output
Key
Nonswitched
Value
Switched
Fuse
(Right Side)
Cover
Option
Hardware
Option
Cooper Bussmann offers a sealed Power Relay Module (PRM)
along with an accompanying Power Fuse Module (PFM). These
compact power distribution modules are designed for high current
applications, and are suitable for placement in extreme moisture
and high vibration environments. The PRM contains a 70A relay
and two female fuse positions. One of these fuses protects the
relay and the other is a single-circuit inline fuse. The PFM con-
tains only two fuses - each a separate circuit. A silicone seal and
removable cover offer a weather-tight enclosure for the fuse posi-
tions. PRMs/PFMs also feature rugged M8 power input studs.
Multiple units may be connected together via a custom buss bar,
or can be bussed to any of Cooper Bussmann’s PDMs (i.e.
31000/32000 Series VEC/DVEC, 15300 Series RTMR, etc.)
SPECIFICATIONS
*PFM always uses this option.
70A-Sealed
❏❏❏❏❏
3 7 7 0 2
12V PRM
❏❏
❏❏❏❏❏
3 7 7 0 3
24V PRM
*1 – Stud/Delphi
2 – Connector/Delphi
3 – Stud/AMP
®
4 – Connector/AMP
®
A – Black (Delphi
only)
B – Grey (AMP
®
or Delphi)
C – Green
(AMP
®
only)
F – Red
(AMP
®
only)
Y – Yellow
(AMP
®
only)
N – Stud
output
(no key)
A – Black
B – Grey
0 – None
2 – 20 amps
3 – 30 amps
4 – 40 amps
5 – 50 amps
6 – 60 amps
0 – None
2 – 20 amps
3 – 30 amps
4 – 40 amps
5 – 50 amps
6 – 60 amps
0 – No cover
1 – Cover
(bulk)
2 – Cover
(installed)
0 – None
1 – Nuts
(bulk)
2 – Nuts
(installed)
3 – CRF
4 – CRF, nuts
(bulk)
5 – CRF, nuts
(installed)
❏❏
Cooper Bussmann Transportation Products • Phone: 1-888-867-8194 • Website: http://www.coopertp.com
Bussmann®POWER RELAY POWER DISTRIBUTION MODULE
9
SERIES 37700 PRM/PFM (Dims. shown are for reference only. Consult factory for latest prints)
MULTIPLE UNIT JOINING LATCH
OUTPUT STUDS
FUSE COVER LOCK/UNLOCK TAB
MOUNTING HOLE
(2) FEMALE MAXI
FUSE COVER:
INPUT STUD
Counter Rotation Feature (CRF)
(2 PLS)
M6X20 STUD
6.5 X 35.4
MOUNTING HOLE
M8X20 STUD
][2.387
60.62
][ 0.276
7.00
][ 0.039
1.00
][ 0.756
19.19
][ 0.394
10.00
(2 PLS)
R][ 0.256
6.50
(2 PLS)
R
][ 0.787
20.00
][ 0.472
12.00
][ 0.787
20.00
][ 0.513
13.04
][ 0.236
6.00
É”
][ 0.256
6.50
É”
][2.008
51.00
][ 1.732
44.00
][ 3.765
95.62
][ 1.575
40.00
MULTIPLE UNIT JOINING LATCH
BATTERY SIDE
OUTPUT STUD
SWITCHED SIDE
OUTPUT STUD
RELAY SIGNAL CONNECTOR
FUSE COVER LOCK/UNLOCK TAB
MOUNTING HOLE
(2) FEMALE MAXI
FUSE COVER
INPUT STUD
Counter Rotation Feature (CRF)
M6 X 20 STUD
SEALED, 2 WAY CONNECTOR
USE WITH DELPHI 150 SERIES,
RELAY SIGNAL CONNECTOR
M8 X 20 STUD 6.5 X 35.4
MOUNTING HOLE
][ 0.256
6.50
É”
][ 0.236
6.00
É”
][ 1.575
40.00
][ 0.787
20.00
][ 0.513
13.04
][ 4.772
121.21
][ 0.472
12.00
][ 2.004
50.90
][ 2.280
57.90
][ 0.039
1.00
][ 0.276
7.00
][ 0.756
19.19
][ 0.394
10.00
(2 PLS)
R][ 0.256
6.50
(2 PLS)
R
][ 0.787
20.00
][ 2.387
60.62
MULTIPLE UNIT JOINING LATCH
MOUNTING HOLE
OUTPUT CONNECTOR LOCKING TAB
OUTPUT CONNECTOR
RELAY SIGNAL CONNECTOR
FUSE COVER LOCK/UNLOCK TAB
(2) FEMALE MAXI
FUSE COVER
INPUT STUD
Counter Rotation Feature (CRF)
M8X20 STUD
P/N 32004
SEALED CONNECTOR
USE WITH BUSSMANN
OUPUT CONNECTOR
SEALED, 2 WAY CONNECTOR
USE WITH DELPHI 150 SERIES,
RELAY SIGNAL CONNECTOR
6.5 X 35.4
MOUNTING HOLE
][ 0.787
20.00
][ 0.276
7.00
][ 0.394
10.00
(2 PLS)
R][ 0.256
6.50
(2 PLS)
R
][ 0.256
6.50
É”
][ 0.236
6.00
É”
][ 2.387
60.62
][ 0.437
11.09
][ 0.039
1.00
][ 0.756
19.19
][ 0.513
13.04
][ 1.575
40.00
][ 0.212
5.38
][ 4.772
121.21
][ 0.472
12.00
][ 2.004
50.90
][ 2.280
57.90
][ 0.787
20.00
Bussmann®ATC®TERMINAL POWER DISTRIBUTION MODULE
10
SERIES 15710 REAR TERMINAL ATC®FUSE BLOCK
Series
❏❏❏❏
1571
1 – Single Stud, Single Supply Circuit
2 – Double Stud, Split Supply Circuit
3 – Triple Buss, Split Supply Circuit
Hardware
Options
0 – W/O nuts
1 – Nuts shipped bulk
2 – Nuts assembled
Cover
Option
0 – No cover
1 – w/ fuse cover
2 – w/ CB cover
Marking
Option
A-Standard
(consult factory for
special marking
QUICK-CONNECT TERMINALS
(Series 15713) 1/4-20 STUD (2 PLACES)
10-32 THREADED INSERTS (4 PLACES)
168.0148.432 POLE
148.0128.428 POLE
128.0108.424 POLE
108.088.420 POLE
88.068.416 POLE
68.048.412 POLE
48.028.48 POLE
VALUE
DIM 'B'
VALUE
DIM 'A'
][1.31
33.3
A
B
][ 1.38
35.0
][ 0.48
12.1
][ 0.41
10.5
][ 2.34
59.4
[2.94± .20]
74.7± 0.5
[3.38±.20]
85.8±0.50
][ 0.42
10.7
][ 0.74
18.8
Middle bus has quick-connect terminals
(series 15713 only)
COVER
TETHER
49.55
[1.95]
FUSE
COVER
66.28
[2.61]
BREAKER
COVER
DIMENSIONS (Dims. shown are for reference only. Consult factory for latest prints)
The Rear Terminal ATC®Fuse Block (RTA) is a rear-fed panel with high compo-
nent retention, which makes it an ideal choice for high vibration environments
including construction, agriculture, bus, RV, heavy trucking equipment, etc. It is
available in multiple lengths and internal bussing configurations. This allows for
up to three separate power input circuits and 32 individual output circuits.
SPECIFICATIONS
Input Terminal Rating: 1/4-20 stud; Quick-connect terminals provided on
middle bus (Series 15713). 200A max total input for unit.
Output Terminal Rating: 30A max load per circuit.
Temperature Rating: –40°F (–40°C) to 260°F (125°C).
Materials: Black thermoplastic.
Termination: Delphi Packard Pack-Con®Series 3 & 5.* Input Wire Size: #4-6
AWG. Output Wire Size: #10-16 AWG.
Torque Rating: 50in-lb (5.6Nm) max.
Mounting Torque Rating: #10-32 threaded inserts, 24in-lb (2.7Nm) max torque.
OPTIONS
Positions: 8-32 circuits available.
Split Power: Single, dual, or triple bus options.
Cover: Splash-resistant covers available. Short cover for fuses only, and taller
cover for use with circuit breakers.
Locks: Secondary locks available for securing of output terminals (#15710-TP).
(Comes in multiples of 8 positions. Must order multiple strips to cover length of
selected RTA.)
Tools: Output terminal removal tool (#HT15710-01). Secondary lock removal
tool (#HT15710-02).
*Electrical Terminals are NOT supplied by Cooper Bussmann.
PART NUMBERING SYSTEM
Cooper Bussmann Transportation Products • Phone: 1888-867-8194 • Website: http://www.coopertp.com
No. of
Positions
❏❏
1
08-32
❏❏ /❏❏
2
Left Side Right Side
06-28 04-28
(max. tot 32) (increments of 4)
❏❏ -❏❏
3
Total Pos Left Side
14-32 06-24
(max. total of 32) (increments of 4)
Cooper Bussmann Transportation Products • Phone: 1-888-867-8194 • Website: http://www.coopertp.com
Bussmann®ATC®TERMINAL POWER DISTRIBUTION MODULE
11
SERIES 15600 ATC®Blade-Type Fuse Panels
No. of Fuses &/or Circuit
Breaker Positions
❏❏
0
04-20
❏❏ /❏❏
2
Left Side Right Side
04-16 04-16
(max. combination of 20)
Series
❏❏❏❏
1560
0 – Single Stud, Single Supply Circuit
2 – Double Stud, Split Supply Circuits
"L"
"C"
1.06"
(26.92)
.62"
(15.75)
.62" TYP (15.75)
.80"
(20.32)
.250" QC (COPPER ALLOY - TIN PLATED)
(15600 -10-20 SHOWN)
.22" DIA. HOLE WITH .41 x .12
DEEP C'BORE (4X)
(12) .250" QC TERMINALS W/COMMON
WIRING STUD, ADD 1.300" TO "L" FOR
OVERALL LENGTH
"L"
"C"
3.37"
(85.59)
2.50"
(63.50)
1.06"
(26.92)
1.22"
(30.98) (15602-04/08-20 SHOWN)
15600 Series 15602 Series
Ground Terminal Base Option
PART NUMBERING SYSTEM
Hardware
Options
0 – W/O nuts
1 – Nuts shipped bulk
2 – Nuts assembled
Ground Terminal
Base
0 – None
1 – Include Ground Pad
No. of 15600 15602 No. of 15600 15602
Fuses “C” “L” “L” Fuses “C” “L” “L”
04 1.84 2.44 14 3.12 4.97 5.56
06 .62 2.47 3.06 16 3.76 5.59 6.19
08 1.25 3.09 3.68 18 4.37 6.22 6.81
10 1.87 3.75 4.32 20 5.00 6.84 7.43
12 2.50 4.34 4.94
Dimensions in inches. Multiply by 25.4 for metric.
DIMENSIONS (Dims. shown are for reference only. Consult factory for latest prints)
The 15600 ATC®fuse block is a compact, yet rugged,
power distribution module. It is available in a single or dual
internal buss electrical configuration featuring an optional
ground pad terminal strip. The 15600 fuse block is surface
mounted, uses convenient quick-connect terminals, and is
recommended as a supplemental power distribution
module. It can be used to accompany main PDMs such as
the Bussmann 31000/32000 Series VEC/DVEC, 15710
Series RTA, and the 15301 Series RTMR.
SPECIFICATIONS
Input Terminal Rating: #10-32 threaded studs (100A max).
Output Terminal Rating: 30A max per circuit.
Temperature Rating: –20°F (0°C) to 150°F (65°C).
Materials: Black thermoplastic.
Termination: .250" x .032" quick-connect terminals.
Ground terminal pad option available. Input wire size: #4-6
AWG. Output wire size: #12-16 AWG.
Torque Rating: 20in-lb (2.25Nm) max.
Mounting Torque Rating: 8in-lb (0.9Nm) max.
OPTIONS
Positions: 4-20 circuits available.
Split Power: Single or dual buss options.
Bussmann®BOLT-IN FUSEHOLDERS
12 Cooper Bussmann Transportation Products • Phone: 1-888-867-8194 • Website: http://www.coopertp.com
HMG FUSEHOLDER
Automotive Bolt-In Fuseholder for the AMG Fuse
PART NUMBERING SYSTEM
BUSSMANN
use AMG fuse
Cover Tether
Tie-Wrap Pass Thru's
.26"
(Ø6.6)
.26"
(Ø6.6)
1.11"
(26.3)
4.80"
(121.8)
1.44"
(36.7)
3.65"
(92.6)
1.51"
(38.4) 0.81"
(20.7")
4.94"
(125.4)
4.94"
(125.4)
4.23"
(107.4) 4.23"
(107.4)
1.02"
(25.8)
Center Mount
Offset Mount
Tie Wrap Mount
DIMENSIONS (Dims.shown are for reference only. Consult factory for latest prints)
Series
❏❏❏
HMG
Base
1 – Tie wrap mount
2 – Offset mounted
3 – Center mounted*
Hardware
1 – 5/16-18 Studs w/nuts
installed
2 – 5/16-18 Studs w/nuts bulk
3 – 5/16-18 Studs w/o nuts
4 – M8 x 1.25 studs w/nuts
installed
5 – M8 x 1.25 studs w/nuts bulk
6 – M8 x 1.25 studs w/o nuts
Style
0 – No cover
1 – Cover installed
2 – Cover bulk
Options
Consult factory for Bus Bar options
*Consult factory for availability.
The HMG fuse holder accepts industry standard AMG
fuses for primary fusing applications. The narrow rugged
body makes it ideal for demanding environments such as
‘under the hood’ locations in construction, agriculture,
heavy trucking, and specialty vehicle applications.
SPECIFICATIONS
Rating: For use with AMG fuses from 100-300A.
Temperature Rating: –40°F (–40°C) to 260°F (125°C).
Materials: Black thermoplastic with zinc-plated steel studs.
Termination: M8 or 5/16-18 threaded studs and hex nuts
for fuse mounting. Wire sizes: #2-8 AWG.
Torque Rating: 150in-lb (17Nm) max.
Mounting Torque Rating: Optional mounting hole
patterns, 44in-lb (5Nm) max.
FEATURES
• Side-stackable
• Bottom side insulated from mounting panel.
• Splash resistant cover.
PART NUMBERING SYSTEM
Series
❏❏❏
F M G
Base
1 – M8 studs
2 – 5/16-18 studs
Hardware
0 – No hardware installed
1 - Nuts installed
2 – Nuts bulk
Cover
0 – No cover
1 – Cover (black) installed
2 – Cover (black) bulk
4 – Cover (red) installed
5 – Cover (red) bulk
6 – Extended Cover (black) installed
7 – Extended Cover (black) bulk
8 – Extended Cover (red) installed
9 – Extended Cover (red) bulk
Cooper Bussmann Transportation Products • Phone: 1-888-867-8194 • Website: http://www.coopertp.com
Bussmann®BOLT-IN FUSEHOLDERS
13
FMG FUSEHOLDER
Full Access Automotive Bolt-In Fuseholder for the AMG Fuse
[121.4]
4.78
2.46
[62.5]
REF.
1.73
[43.9]
REF.
4.00
[101.6]
4.23
[107.4]
.80
[20.4]
1.35
[34.4]
Ø.25
[Ø6.4] .96
[24.5]
(EXTENDED
COVER)
.77
[19.5]
(STANDARD
COVER)
DIMENSIONS (Dims.shown are for reference only. Consult factory for latest prints)
The FMG fuse holder accepts industry standard AMG fuses for primary
fusing applications. The FMG is offered with a tough elastomer cover for
fuse protection, yet allows for cable input from various orientations. This
fuse holder cover is available in multiple colors and lengths. Similar to
Bussmann’s HMG holder, the FMG is well suited for demanding environ-
ments such as ‘under the hood’ locations in construction, agriculture,
heavy trucking, and specialty vehicle applications.
SPECIFICATIONS
Rating: For use with AMG fuses from 100-300A.
Temperature Rating: –40°F (–40°C) to 260°F (125°C).
Materials: Black thermoplastic with zinc-plated steel studs; thermoplastic
elastomer cover.
Termination: M8 or 5/16-18 threaded studs and hex nuts for fuse mount-
ing. Wire sizes: #2-8 AWG.
Torque Rating: 120in-lb (13.5Nm) max.
Mounting Torque Rating: 1/4-20 screws with washers (recommended),
44in-lb (5Nm) max.
OPTIONS
Cover: Available in black or red. Extended cover length also available.
FEATURES
Full access for cables. Can be routed to studs from nearly every direction.
1.56"
4.75" 4.75"
.25"
.25"
.59"
.41"
MINI
®
Fuse Blade Type Holder
Catalog No. Description Fuse Size Electrical Connection
HHL Fuseholder w/cover 2–20 A #16 AWG lead black wire;
HHL-B Body only 4" length
HHM Fuseholder w/cover
2–30 A #12 AWG lead red wire;
HHM-B Body only 4" length
HHM-C Cover only
Dimensions in inches. Multiply by 25.4 for metric.
(Dims. Shown are for reference only. Contact factory for latest prints)
(Dims. Shown are for reference only.
Contact factory for latest prints)
Bussmann®INLINE FUSEHOLDERS
14 Cooper Bussmann Transportation Products • Phone: 1-888-867-8194 • Website: http://www.coopertp.com
HHX
In-Line Fuseholder for MAXIFuses.
Rating: 32V, 60A Max. Firewall mounting hole
permits two or more holders to be mounted
together. Cover comes with a removable strap.
INLINE FUSEHOLDERS
3.35"
6.70" 6.70"
1.37"
.265" DIA. HOLE
In-Line Fuseholders for Blade-Type Fuses
MAXI
Fuse Blade Type Holder
Catalog No. Description Fuse Size Electrical Connection
HHX Fuseholder w/cover
#6 lead wire;
HHX-B Body only 20–60 amps 5" length
HHX-C Cover only
ATC
®
Blade Type Holder
Catalog No. Description Fuse Size Electrical Connection
HHC Yellow fuseholder (body only) 1–20 A #16 AWG lead black wire
HHD Black fuseholder (body only) 1–30 A #12 AWG lead yellow wire
HHD-C Cover only Fits only HHD Clear polycarbonate
HHF Black fuseholder w/cover 1–20 A #16 AWG lead yellow wire
HHG Black fuseholder w/cover 1–30 A #12 AWG lead yellow wire
HHR Black waterproof fuseholder 1–30 A #12 AWG lead orange wire
w/locking cover & mounting hole 5” length
HHS Blue fuseholder 1–20 A Self-stripping; accepts #18-
#14 AWG copper wire only
Dimensions in inches. Multiply by 25.4 for metric.
Dimensions in inches. Multiply by 25.4 for metric.
HHC, HHD, HHF,
HHG, HHR, and HHS
In-Line Fuseholders for ATC®Blade-Type Fuses.
Rating: 32V, See table for max. amp. “Write-in”
space for circuit identification on HHC holder.
Plastic cover fits only HHD holder. HHR holder is
waterproof with a locking cover and mounting
hole. HHS is a self-stripping holder.
HHL and HHM
In-Line Fuseholders for ATM MINI®Fuses.
Rating: 32V, See table for max. amp.
Body material withstands high temps.
Protective cover has removable straps. Rated
IP67 with cover installed.
4"
.250"
.430"
1.000" 4"
.670"
(TYP/2)
.810"
0.360" 1.250"
.920"
.606"
1.820"
1.100"
1.850" 5"
HHR
HHF / HHG
HHD HHC
(Dims. Shown are for reference only.
Contact factory for latest prints)
ON
ON
OFF
3.81"
(96.8)
1.56"
(39.7)
1.12"
(28.4)
.50"
(12.7)
2.75"
(69.8) Ref.
Point A
5.5"
(139.7) 7.0"
(177.8) 8.0"
(203.2)
4.19"
(106.4)
3.5"
(88.9)
3.0"
(76.2)
.59"
(15.1)
4.87"
(123.8)
2.44"
(61.9)
1.25"
(31.7)
3.12"
(79.4)
Ref. Point A
Ref. Point A
Ref. Point A
3.00"
(76.2)
4.50"
(114.3)
15250-1
15250-2
15250-3
1/2-13 Copper alloy stud
Stainless washers and locknuts supplied
Cooper Bussmann Transportation Products • Phone: 1-888-867-8194 • Website: http://www.coopertp.com
Bussmann®BATTERY DISCONNECT
15
SERIES 15250
Battery Disconnect Switch
Handle Variations
PART NUMBERING SYSTEM
Series
❏❏❏❏❏
15250
Bracket
Option
Lubricant
w/Sealant
❏❏
LR
Handle
Option
1
2
3
B – Bracket (Grease Filled)
DIMENSIONS (15250-1B Shown) (Dims. shown are for reference only. Consult factory for latest prints)
SPECIFICATIONS
Applications: A non-fused current interrupt disconnect
designed for opening the circuit between a battery and the
complete electrical load of a battery-powered system.
Rating: 400A continuous,. 50VAC/VDC. Vehicle cranking and
max. surge currents to 2,000A (based on 20% duty cycle with
ON times of 5 seconds max.).
Temperature Rating: –40°F (–40°C) to 150°F (65°C).
Termination: 1/2-13 Copper alloy stud.
Torque Rating: 420in-lb (47.5Nm) max.
Mounting Torque Rating: With mounting brackets: 48in-lb
(5.4Nm) max; without mounting brackets: 10in-lb (1.1Nm)
max.
OPTIONS
Handles: Three handle styles available.
Other: Lubricant-filled body with silicone sealant.
(Dims. shown are for reference only.
Consult factory for latest prints)
Bussmann®VEHICLE IGNITION PROTECTION CENTER
Cooper Bussmann Transportation Products • Phone: 1-888-867-8194 • Website: http://www.coopertp.com
Bussmann®JUNCTION BLOCKS
16
STUD TYPE JUNCTION BLOCKS
F
KA KA KA
JH
GED
CB
M (thread size)
.75"
(19.1) .75"
(19.1)
1.87"
(47.6)
1.12"
(28.6)
L (4 MTG. HOLES)
L(2 MTG. HOLES) L(2 MTG. HOLES)
Fig. 1 Fig. 2 Fig. 3
SPECIFICATIONS
Applications: Heavy-duty ground or power
connection points in AC or DC circuits. Feed-
thru or stand alone mount options available for
transformers, communication and computer
power sections along with various vehicle elec-
trical systems.
Mounting Torque Rating: 48in-lb (5.4Nm) max.
FEATURES
Modular design offers design and manufactur-
ing flexibility.
Suggested Max. Termination Ratings:
Part Fig. A B C D E F G H J K L M Max. Torque (in-lb) Material Color
C1925*1 2.75 1.5 1.25 1.25 1.12 .37 1.12 .19 .19 2.0 .22 dia. w/.44 dia. 1/2-13 300 Thermoplastic / Red
(69.8) (38.1) (31.7) (31.7) (28.6) (9.5) (28.6) (4.8) (4.8) (50.8) C’bore x .16 deep Zinc plated Brass
C1925B* 1 2.75 1.5 1.25 1.25 1.12 .37 1.12 .19 .19 2.0 .22 dia. w/.44 dia. 1/2-13 300 Thermoplastic / Black
(69.8) (38.1) (31.7) (31.7) (28.6) (9.5) (28.6) (4.8) (4.8) (50.8) C’bore x .16 deep Zinc plated Brass
C1925-1* 1 2.75 1.5 1.25 1.25 1.12 .37 1.12 .19 .19 2.0 .22 dia. w/.44 dia. 1/2-13 300 Thermoplastic / Red
(69.8) (38.1) (31.7) (31.7) (28.6) (9.5) (28.6) (4.8) (4.8) (50.8) C’bore x .16 deep Tin plated Brass
C1925-1B* 1 2.75 1.5 1.25 1.25 1.12 .37 1.12 .19 .19 2.0 .22 dia. w/.44 dia. 1/2-13 300 Thermoplastic / Black
(69.8) (38.1) (31.7) (31.7) (28.6) (9.5) (28.6) (4.8) (4.8) (50.8) C’bore x .16 deep Tin plated Brass
C1925-2* 1 2.75 1.5 1.25 1.25 1.12 .37 1.12 .19 .19 2.0 .22 dia. w/.44 dia. 3/8-16 150 Thermoplastic / Red
(69.8) (38.1) (31.7) (31.7) (28.6) (9.5) (28.6) (4.8) (4.8) (50.8) C’bore x .16 deep Tin plated Brass
C1925-2B* 1 2.75 1.5 1.25 1.25 1.12 .37 1.12 .19 .19 2.0 .22 dia. w/.44 dia. 3/8-16 150 Thermoplastic / Black
(69.8) (38.1) (31.7) (31.7) (28.6) (9.5) (28.6) (4.8) (4.8) (50.8) C’bore x .16 deep Tin plated Brass
C1933 1 2.75 1.44 1.25 1.5 1.12 .37 None .19 None 2.0 .22 dia. 1/2-13 300 Thermoplastic / Black
(69.8) (36.6) (31.7) (38.1) (28.6) (9.5) (4.8) (50.8) Zinc plated Brass
C1933-1 1 2.75 1.44 1.25 1.5 1.12 .37 None .19 None 2.0 .22 dia. 5/16-18 75 Thermoplastic / Black
(69.8) (36.3) (31.7) (38.1) (28.6) (9.5) (4.8) (50.8) Zinc plated Brass
C1938*2 2.06 .94 .69 .87 .69 .31 .94 .06 .06 1.31 .22 dia. w/.41 dia. 3/8-16 150 Thermoplastic / Black
(52.4) (23.8) (17.5) (22.2) (17.5) (7.9) (23.8) (1.6) (1.6) (33.3) C’bore x 14 deep Zinc plated Brass
C1938R* 2 2.06 .94 .69 .87 .69 .31 .94 .06 .06 1.31 .22 dia. w/.41 dia. 3/8-16 150 Thermoplastic / Red
(52.4) (23.8) (17.5) (22.2) (17.5) (7.9) (23.8) (1.6) (1.6) (33.3) C’bore x 14 deep Zinc plated Brass
C1938-1* 2 2.06 .94 .69 .87 .69 .31 .94 .06 .06 1.31 .22 dia. w/.41 dia. 5/16-18 75 Thermoplastic / Black
(52.4) (23.8) (17.5) (22.2) (17.5) (7.9) (23.8) (1.6) (1.6) (33.3) C’bore x 14 deep Tin plated Brass
C1938-1R* 2 2.06 .94 .69 .87 .69 .31 .94 .06 .06 1.31 .22 dia. w/.41 dia. 5/16-18 75 Thermoplastic / Red
(52.4) (23.8) (17.5) (22.2) (17.5) (7.9) (23.8) (1.6) (1.6) (33.3) C’bore x 14 deep Tin plated Brass
C2791*3 2.06 .69 .44 .62 .69 .31 .69 .06 .06 1.31 .22 dia. w/.41 dia. 1/4-20 30 Thermoplastic / Black
(52.4) (17.5) (11.2) (15.9) (17.5) (7.9) (17.5) (1.6) (1.6) (33.3) C’bore x .14 deep Zinc plated Brass
C2791-R*3 2.06 .69 .44 .62 .69 .31 .69 .06 .06 1.31 .22 dia. w/.41 dia. 1/4-20 30 Thermoplastic / Red
(52.4) (17.5) (11.2) (15.9) (17.5) (7.9) (17.5) (1.6) (1.6) (33.3) C’bore x .14 deep Zinc plated Brass
C2909*3 2.06 .69 .44 .62 1.0 .31 .69 .06 .06 1.31 .22 dia. w/.41 dia. 10-32 24 Thermoplastic / Black
(52.4) (17.5) (11.2) (15.9) (25.4) (7.9) (17.5) (1.6) (1.6) (33.3) C’bore x 14 deep Zinc plated Brass
C2909-1*3 2.06 .69 .44 .62 1.0 .31 .69 .06 .06 1.31 .22 dia. w/.41 dia. 1/4-20 30 Thermoplastic / Black
(52.4) (17.5) (11.2) (15.9) (25.4) (7.9) (17.5) (1.6) (1.6) (33.3) C’bore x 14 deep Zinc plated Brass
C4044*2 2.06 .87 .62 .62 1.12 .31 .94 .06 .06 1.31 .22 dia. w/.41 dia. 3/8-16 150 Thermoplastic / Black
(52.4) (22.2) (15.9) (15.9) (28.6) (7.9) (23.8) (1.6) (1.6) (33.3) C’bore x .14 deep Zinc plated Brass
C4044-1* 2 2.06 .87 .62 .62 1.12 .31 .94 .06 .06 1.31 .22 dia. w/.41 dia. 3/8-16 150 Thermoplastic / Black
(52.4) (22.2) (15.9) (15.9) (15.9) (7.9) (23.8) (1.6) (1.6) (33.3) C’bore x .14 deep Tin plated Brass
C4044-1R* 2 2.06 .87 .62 .62 1.12 .31 .94 .06 .06 1.31 .22 dia. w/.41 dia. 3/8-16 150 Thermoplastic / Red
(52.4) (22.2) (15.9) (15.9) (15.9) (7.9) (23.8) (1.6) (1.6) (33.3) C’bore x .14 deep Tin plated Brass
C5898*2 2.06 .94 .69 .87 .69 .31 .94 .06 .06 1.31 .22 dia. w/.41 dia. 3/8-16 150 Thermoplastic / Red
(52.4) (23.8) (17.5) (22.2) (17.5) (7.9) (23.8) (1.6) (1.6) (33.3) C’bore x .14 deep Zinc plated Brass
C6344-2 2 2.06 .87 .62 .62 1.12 .31 None .06 None 1.31 .22 dia. w/.41 dia. 1/2-20 150 Thermoplastic / Black
(52.4) (22.2) (15.9) (15.9) (15.9) (7.9) (1.6) (33.3) C’bore x .14 deep Zinc plated Steel
C7018*3 2.06 .69 .44 .47 .69 .31 .53 .06 .06 1.31 .22 dia. w/.41 dia. M6 55 Thermoplastic / Black
(52.4) (17.5) (11.2) (11.9) (17.5) (7.9) (13.5) (1.6) (1.6) (33.3) C’bore x 14 deep Zinc plated Steel
C7020* 2 2.06 .94 .69 .88 .69 .31 1.25 .06 .06 1.31 .22 dia. w/.41 dia. 3/8-16 150 Thermoplastic / Red
(52.4) (23.8) (17.5) (22.2) (17.5) (8.0) (31.8) (1.6) (1.6) (33.3) C’bore x 14 deep Zinc plated Brass
JB3816-2 2 2.12 .98 .62 .87 .69 .31 None .06 None 1.37 .22 dia. w/.37 dia. 3/8-16 150 Thermoplastic / Black
(54.0) (24.9) (15.9) (22.2) (17.5) (7.9) (1.6) (34.9) C’bore x .14 deep Zinc plated Sleel
JB3816-3 2 2.12 .98 .62 .87 .69 .31 None .06 None 1.37 .22 dia. w/.37 dia. 3/8-16 150 Thermoplastic / Red
(54.0) (24.9) (15.9) (22.2) (17.5) (7.9) (1.6) (34.9) C’bore x .14 deep Zinc plated Sleel
*Feed-thru Options – Nuts & washers; consult factory.
Thread/Stud Size Amperages
#10 50 amps
#1/4 & M6 100 amps
#5/16 200 amps
#3/8 250 amps
#1/2 400 amps
DIMENSIONS
Cooper Bussmann Transportation Products • Phone: 1-888-867-8194 • Website: http://www.coopertp.com
Bussmann®JUNCTION BLOCKS
17
STUD TYPE JUNCTION BLOCKS (Non Feed-Thru)
A
C
B
.75"
.375"
.375"
.625"
1.0"
.31"
.81"
1.16"
.31"
.5"
1.16"
Mtg. holes 9/32"X3/8" slot
JB1032-120-XX
(No bosses between studs)
C5237
(A,B,C Dimensions ars the same as C5237)
A
C
B
.75"
(19.05)
.75"
(19.05).375"
(9.53)
.375"
(9.53)
1.12"
(28.45)
0ther series available with .750" centers:
#10-32 zinc plated
steel studs
.31"
(7.87)
.31"
(7.87)
.84"
(21.34)
.84"
(21.34)
1.09"
(27.69)
C6083
C4559
1.05"
(26.67)
Mtg. holes 9/32"x 3/8" slot
(A,B,C Dimensions are the same as C4559)
Part No. A B C
C4559-2 3.00 (76.2) 2.25 (57.1) 0.75 (19.0)
C4559-3 3.75 (95.2) 3.00 (76.2) 1.50 (38.1)
C4559-4 4.50 (114.3) 3.75 (95.2) 2.25 (57.1)
C4559-5 5.25 (133.3) 4.50 (114.3) 3.00 (76.2)
C4559-6 6.00 (152.4) 5.25 (133.3) 3.75 (95.2)
C4559-7 6.75 (171.4) 6.00 (152.4) 4.50 (114.3)
C4559-8 7.50 (190.5) 6.75 (171.4) 5.25 (133.3)
C4559-9 8.25 (209.5) 7.50 (190.5) 6.00 (152.4)
C4559-10 9.00 (228.6) 8.25 (209.5) 6.75 (171.4)
C4559-11 9.75 (247.6) 9.00 (228.6) 7.50 (190.5)
C4559-12 10.50 (266.7) 9.75 (247.6) 8.25 (209.5)
C4559-13 11.25 (285.7) 10.50 (266.7) 9.00 (288.6)
C4559-14 12.00 (308.4) 11.25 (285.7) 9.75 (247.6)
C4559-15 12.75 (323.8) 12.00 (308.4) 10.50 (266.7)
C4559-16 13.50 (342.9) 12.75 (323.8) 11.25 (285.7)
Part No. A B C
C5237-1 2.00 (50.8) 1.25 (31.7)
C5237-2 2.62 (66.7) 1.87 (47.5) .625 (15.9)
C5237-3 3.25 (82.5) 2.50 (63.4) 1.25 (31.7)
C5237-4 3.87 (98.4) 3.12 (79.4) 1.87 (47.5)
C5237-5 4.50 (114.3) 3.75 (95.2) 2.50 (63.4)
C5237-6 5.12 (130.8) 4.37 (111.1) 3.12 (79.4)
C5237-7 5.75 (146.0) 5.00 (127.0) 3.75 (95.2)
C5237-8 6.37 (161.9) 5.62 (142.9) 4.37 (111.1)
C5237-9 7.00 (177.8) 6.25 (158.7) 5.00 (127.0)
C5237-10 7.62 (193.7) 6.87 (174.6) 5.62 (142.9)
C5237-11 8.25 (209.5) 7.50 (190.5) 6.25 (158.7)
C5237-12 8.87 (225.4) 8.12 (206.4) 6.87 (174.6)
C5237-13 9.50 (241.3) 8.75 (222.2) 7.50 (190.5)
C5237-14 10.12 (257.2) 9.37 (238.1) 8.12 (206.4)
C5237-15 10.75 (273.0) 10.00 (254.0) 8.75 (222.2)
Dimensions
Dimensions
Series C4559 & C6083
SPECIFICATIONS
Rating: 30A, 600V
Temperature Rating: 250°F (120°C)
Materials: Black thermoplastic with zinc-plated steel studs.
Termination: #10-24 threaded studs on .750" centers. Studs feature a “dog
point” to guide nut onto thread.
Torque Rating: 25 in-lb (2.8Nm) max.
Mounting Torque Rating: 24in-lb (2.7Nm) max.
OPTIONS
Positions: 2-16 positions available.
FEATURES
Numbers and arrows molded on top of barriers indicate terminals.
Compliances: UL/CSA; CE Certified.
Series C5237 & JB1032
SPECIFICATIONS
Rating: UL: 30A, 300V; CSA: 30A, 600V.
Temperature Rating: 250°F (120°C)
Materials: Black thermoplastic with brass studs.
Termination: #10-32 threaded studs on .625" centers. Studs feature a “dog
point” to guide nut onto thread.
Torque Rating: 25 in-lb (2.8Nm) max.
Mounting Torque Rating: 24in-lb (2.7Nm) max.
OPTIONS
Positions: 1-15 positions available.
FEATURES
Numbers and arrows molded on top of barriers indicate terminals.
Compliances: UL/CSA; CE Certified.
(Dims. shown are for reference only.
Consult factory for latest prints)
(Dims. shown are for reference only.
Consult factory for latest prints)
Bussmann®
18 Cooper Bussmann Transportation Products • Phone: 1-888-867-8194 • Website: http://www.coopertp.com
Basic Overcurrent Technology
Overcurrent devices may serve several purposes in
electrical circuits:
• To protect components, equipment, and associated wiring
from the effects of electric circuit overloads and/or short
circuits.
• To isolate branch circuits from the main power supply
once an overload or short circuit has occurred.
Fuses and circuit breakers are commonly selected as the
preferred overcurrent device.
TYPES OF OVERCURRENT
An overcurrent device is constructed to react in a
prescribed fashion to varying levels of electrical current,
where at pre-determined levels, the device provides
interruption of the current flow through it. Any current that
exceeds the ampere rating of the fuse or circuit breaker is
an overcurrent. Overcurrents are generally classified as
either short circuits or overloads and are defined as
follows:
Short circuit - a current that greatly exceeds the rating of
the device. It is caused when a malfunction or accident
creates a break in the normal path allowing electricity to
flow directly to ground or another phase. This shorter
current path bypasses the resistance offered by the
circuit components and the load connected in the normal
current path. In this situation there is little resistance to
impede the current and the current will build to a level
where the heat generated can cause insulation damage
and/or equipment breakdown.
• Overload - an overcurrent that is within the normal
current path. Overloads occur when the current exceeds
the value for which the equipment or associated wiring is
rated. This typically occurs when too many devices are
connected to the circuit or when a device connected to
the circuit malfunctions. Overloads are also caused by
harmless temporary surge currents; such as when motors
are started. These overload currents are normal, usually
brief in duration, and have no harmful effect on the circuit
components. (It is important that protective devices do
not react to such overloads.) Sustained overloads,
however, may slowly cause overheating of the wiring and
the components. Provided the overload is of sufficient
magnitude and duration to activate the device, the circuit
protection device shall open before the overload induces
system component failures.
SELECTING OVERCURRENT PROTECTION
During normal conditions, an overcurrent protection device
must carry the current without nuisance openings.
However, when an overload or short circuit occurs the
device interrupts the overcurrent and withstands the
voltage across the device. To properly select an
overcurrent device the following items must be carefully
considered:
• Voltage rating - represents the maximum system voltage
present in the circuit in which the overcurrent device is
installed. The system voltage should not exceed this
value for proper operation of the device during an
overcurrent event.
• Current Rating - the amperage value marked on the
circuit protection device. The circuit protection device is
designed to handle this value under steady operating
conditions and at room ambient temperatures. Since field
applications often deliver loading conditions and ambient
temperatures that vary from ideal nominal settings, it is
recommended that circuit designers select device ratings
above the nominal circuit current continuous load to
prevent nuisance trips. Additionally, the continuous
current flowing through the overcurrent protective device
should not be more than 80% of the current rating.
• Characteristics of equipment to be protected - during
the operation of protected equipment, system current can
significantly vary. This is particularly evident when motor
or other inductive loads in the circuit cause large current
surges during start-up. Circuit protection designers should
be aware of these surges and/or in-rush characteristics
and select the overcurrent protection devices accordingly.
Available short circuit current - during a fault or short
circuit condition the fuse or circuit breaker may see a
large amount of current. Large DC battery supplies and
high current rated electric distribution buses often have
this potential for severe short circuits. In these situations,
the circuit protection device should have an interrupting
rating that is equal to or greater than the short circuit
current that can be delivered.
Ambient temperature - the time it takes to interrupt the
current is dependent upon the ambient current
temperature characteristics. Ambient temperature refers
to the temperature of the air immediately surrounding the
circuit protection device. The ambient temperature around
the fuse or circuit breaker can be appreciably different
than the outside room or larger enclosure containing the
device. This can occur when the device is contained in a
tight area or it is mounted in or near a heat-producing
component such as a transformer or resistor. When
selecting a fuse or circuit breaker at ambient
temperatures significantly different from the stated
nominal temperature, the circuit designer should adjust
the selected overcurrent protection rating based on the
published temperature re-rating curves.
OVERCURRENT PROTECTION DEVICES
Two categories of overcurrent devices are available.
Fuses
The key component of a fuse is the “element’, a short
piece of metallic wire or link made of a material with a
CIRCUIT PROTECTION PRODUCTS
relatively low and predictable melting point. Fuses are
current-sensitive devices and the resistance is so low that
they simply act as a conductor. Circuit protection is
provided when the fuse element melts and interrupts an
overcurrent. The key criteria used to judge the performance
of a fuse is the time-versus-current characteristic curve.
This curve can be used to match the fuse with the load.
Fuses may be preferred when fast response to a short
circuit condition is required or when high available short
circuit currents occur. Fuse characteristic curves can be
used to carefully size the device to a critical or special
application.
Thermal Circuit Breakers
The basic components of a thermal circuit breaker are the
thermal alloy element, electrical contacts, and the terminals
for external connections. When an overload occurs, heat is
generated as the current flows through the thermal alloy
element causing it to deflect and separate the electrical
contacts, interrupting current flow. An important parameter
used to judge the performance of a thermal circuit breaker
is the time-versus-current characteristic curve, which is
similar to that of a fuse. A thermal circuit breaker is
generally not a one-event type device as is a fuse. The
resettable features of circuit breakers are often found
attractive for use in electrical circuits where non-resetting
interruption of current flow is undesirable. It is important to
note that cycle life of a thermal circuit breaker is
impacted both by the operational characteristic of the
circuit breaker as well as the relative magnitude and
duration of overcurrents or short circuits that the
device experiences. There are different operational
characteristics of Cooper Bussmann thermal circuit
breakers, which are described below.
CIRCUIT BREAKER
OPERATIONAL CHARACTERISTICS
Four different methods for reset are generally available:
Type I (automatic reset): the circuit breaker trips and
resets in response to the overcurrent condition in a
repetitive fashion. This version should be used in
applications that provide for other self-limiting or
non-resettable means (such as after a main fuse, main
manual-reset circuit breaker, or momentary switch).
These devices, while automatic in reset function, are
not designed for long-term cycling conditions in
applications where operator awareness of circuit fault
or serviceability access is limited, leading to
unsatisfactory failure events. Refer to SAE J553 or
J1625 for additional details.
Type II (modified reset): the circuit breaker contains an
additional resistive component that enables the device to
have only brief trip and reset activity and then afterwards
maintains an open circuit condition (except for a low
milliamp draw through the resistor). Requires minimum
voltage/current to maintain open circuit - see standards for
details SAEJ553.
Type III (manual reset): the circuit breaker will trip in
response to an overcurrent condition after which a reset
button or lever extends externally to indicate that the
breaker has tripped and is in a non-conducting state. The
trip indicator button or lever must be manually activated to
return the device to normal operation.
Type III (switchable): same as the manual Type III
manual reset with the additional feature of allowing the
user to open the circuit using an externally accessible trip
mechanism.
CIRCUIT BREAKER APPLICATION NOTES
Circuit Breaker Performance - Cooper Bussmann
thermal circuit breakers are designed to conform to
relevant industry standards (refer to individual models for
standard references). There are specific performance
aspects that may not always make circuit breakers
suitable for certain applications, especially in circuits
that are incapable of providing enough current to
operate the circuit breaker in a timely manner relative
to the associated components and wiring. It is of
utmost importance that the circuit designer investigates
components that have finite overload capabilities which
are below the time-current levels to initiate timely circuit
breaker activation.
Evaluation - Design-in situations require that the user
considers all application conditions and conducts
operational testing to establish the correctness of
ampere/voltage rating as well as overload protection
suitability. Further review of industry standards is advised
to understand all performance aspects that affect usage.
Wiring Considerations - Additional evaluation of circuit
conditions is essential to achieve proper matching of wire
sizes to the current load conditions anticipated under
normal operating conditions, and estimated abnormal
operating conditions when overloads could occur. Thermal
circuit breakers and fuses introduce some level of
resistance to the current path where installed. These
factors should also be considered when choosing wire,
both in gauge as well as in temperature rating
of insulation.
Installation Environment - Thermal circuit breakers are
produced in various configurations. Installation
environmental conditions need to be considered and
compared to the capability of the particular product of
choice. Not all circuit breaker designs are suitable for
harsh conditions, such as may be encountered under-
hood or external cavities.
Cooper Bussmann Transportation Products • Phone: 1-888-867-8194 • Website: http://www.coopertp.com
Bussmann®CIRCUIT PROTECTION PRODUCTS
19
Basic Overcurrent Technology
.430"
(10.92)
.15"
(3.81)
.320"
REF.
(8.13)
.295"
(7.49)
.345"
(8.76)
.110"
(2.79) .0325"
(.82)
.150"
(3.81)
32V
Bussmann®MINI TERMINAL CIRCUIT PROTECTION
20 Cooper Bussmann Transportation Products • Phone: 1-888-867-8194 • Website: http://www.coopertp.com
MINI BLADE FUSES
ATM Mini – Fuse
Fast Acting
SPECIFICATIONS
Current Rating: 2-30A.
Voltage Rating: 32VDC.
Interrupt Rating: 1,000A @ 32VDC.
Housing Material: UL-Rated 94V-0 thermoplastic.
Terminal Material: Silver-plated zinc alloy.
Marking: Amperage marking is OCR compliant.
Compliances: UL-Listed; SAE J2077; ISO 8820-3.
Consult factory for higher voltage fuses.
.4
1
10
100
200
CURRENT IN AMPERES
100
10
.1
1
.01
TIME IN SECONDS
AMPERE
RATING
2A
3A
4A
5A
7.5A
10A
15A
20A
25A
30A
DIMENSIONS (Dims. shown are for reference only. Consult factory for latest prints)
Part No. Amp Rating Color
BK/ATM-2 2 Gray
BK/ATM-3 3 Violet
BK/ATM-4 4 Pink
BK/ATM-5 5 Tan
BK/ATM-7.5 7.5 Brown
BK/ATM-10 10 Red
BK/ATM-15 15 Lt. Blue
BK/ATM-20 20 Yellow
BK/ATM-25 25 Natural
BK/ATM-30 30 Green
MINI FUSE PULLER - PART NUMBER 32002
MINI FUSE
MINI CB
See page 27 for
more information.
Cooper Bussmann Transportation Products • Phone: 1-888-867-8194 • Website: http://www.coopertp.com
Bussmann®MINI TERMINAL CIRCUIT PROTECTION
21
SERIES 21X MINI CIRCUIT BREAKERS
.490"
(12.45)
1.06"
(26.92)
.354"(8.99)
.435"
(11.05)
.110"
(2.79)
.32"
(8.13)
.032"(.81)
.150"(3.81)
.250"(6.35)
PART NUMBERING SYSTEM
Series
❏❏❏
21
211 – Type I, 14VDC
212 – Type II, 14VDC
Rating
❏❏
05 – 5 amps
75 – 7.5 amps
10 – 10 amps
15 – 15 amps
20 – 20 amps
25 – 25 amps
30 – 30 amps
Marking
❏❏
00 – Std. Marking
(Consult Factory for
Special Marking
Options)
Special Options
(Consult Factory for
Special Options)
1000
100
10
1
0.1
100% 200% 300% 400% 500% 600%
TRIP TIME VS. PERCENT OF RATED CURRENT
% of Rated Current
Time in Seconds
-50
0
50
100
150
200
-25 0 25 50 75 100
TEMPERATURE DERATING CURVES
AMBIENT TEMPERATURE IN DEGREES C
Maximum % Hold Current
MINI FUSE
MINI CB
MINI FUSE PULLER - PART NUMBER 32002
See page 27 for
more information.
DIMENSIONS (Dims. shown are for reference only. Consult factory for latest prints)
SERIES 21X
MINI CIRCUIT BREAKERS
Auto & Modified Reset
SPECIFICATIONS
Single Pole Thermal Type Breakers
Rating: 5-30A; 14VDC.
Interrupt Rating: 150A @ 14VDC (5-10A versions); 225A
@ 14VDC (15A version); 300A @ 14VDC (20A version);
450A @ 14VDC (25-30A versions).
Operating Temperature Rating: –40°F (–40°C) to
185°F (85°C).
Storage Temperature Rating: –40°F (–40°C) to
260°F (125°C).
Materials: Grey UL-Rated 94V-0 thermoplastic housing
with metal cover: gold (Type I) or silver (Type II).
Marking: Standard marking includes amp/voltage ratings,
part number, and date code. OCR marking is available.
Termination: Compatible with 280 Type fuse blocks using
0.32in. (8.1mm) centerline spacing.
Compliances: SAE J553 Type I and Type II Circuit
Breakers.
Bussmann®ATC®TERMINAL CIRCUIT PROTECTION
22 Cooper Bussmann Transportation Products • Phone: 1-888-867-8194 • Website: http://www.coopertp.com
ATC®BLADE FUSES
ATC®Blade – Type Fuse
Fast Acting
SPECIFICATIONS
Current Rating: 1-40A.
Voltage Rating: 32VDC.
Interrupt Rating: 1,000A @ 32VDC.
Housing Material: UL-Rated 94V-0 thermoplastic.
Terminal Material: Tin-plated zinc alloy.
Marking: Amperage marking is OCR compliant.
Compliances: UL-Recognized (3-40A);
SAE J1284; ISO 8820-3
Consult factory for higher voltage fuses.
BUSS
ATC
20
.15"
(3.80)
.03"
(.69)
.46"
(11.7)
.76"
(19.30)
.49"
(12.54)
.26"(6.67)
.16"
(4.13) .57"
(14.61)
.75"
(19.05)
.21"
(5.25)
Part No. Amp Rating Color
BK/ATC-1 1 Black
BK/ATC-2 2 Gray
BK/ATC-3 3 Violet
BK/ATC-4 4 Pink
BK/ATC-5 5 Tan
BK/ATC-7.5 7.5 Brown
BK/ATC-10 10 Red
BK/ATC-15 15 Lt. Blue
BK/ATC-20 20 Yellow
BK/ATC-25 25 Clear
BK/ATC-30 30 Green
BK/ATC-40 40 Amber
1
10
100
1000
CURRENT IN AMPERES
100
10
1
.1
.01
TIME IN SECONDS
10
15
20
25
30
AMPERE
RATING
7.5
5
4
3
40
ATC®FUSE PULLER - PART NUMBER 32003
DIMENSIONS (Dims. shown are for reference only. Consult factory for latest prints)
ATC FUSE
ATC CB
See page 27 for
more information.
Series
❏❏❏
22
221 – Type I, 14VDC
222 – Type II, 14VDC
223 – Type III, 28VDC
226 – Type III w/Push-to-trip
option, 28VDC
Consult factory for
terminal option availability.
See page 27 for more
information.
ATC FUSE
ATC CB
PART NUMBERING SYSTEM
Rating
❏❏
05 _amps [LT. Brown (Tan)]*
75 – 7.5 amps [Brown]*
10 – 10 amps [Red]*
15 – 15 amps [Blue]*
20 – 20 amps [Yellow]*
25 – 25 amps [White]*
30 – 30 amps [Green]*
Terminal
0 – ATC
®
Fuse, 4mm Insertion Depth
2 – 8.1mm Centerline 280 (MINI)
3 – ATC
®
Fuse, Delphi Packard
Autofuse Block (e.g. 12004943)
4 – ATC
®
Fuse, Blocks with Raised
Shrouds, 6.4mm Insertion Depth
Marking
00 – Std. Marking
(Consult factory for
special marking options)
Cooper Bussmann Transportation Products • Phone: 1-888-867-8194 • Website: http://www.coopertp.com
Bussmann®ATC®TERMINAL CIRCUIT PROTECTION
23
SERIES 22X ATC®CIRCUIT BREAKERS
RESET BUTTON
(Series 223/226) TRIP LEVER
(Series 226)
34
2
0
][ 0.247
6.28 REF
][ 0.508
12.91REF
][ 0.074
1.88 REF
][ 0.428
10.88 REF
][0.153
3.88REF
][ 0.405
10.28REF
][0.288
7.32 REF
][ 0.310
7.88 REF
][ 0.562
14.28 REF
][0.032
0.80REF
][0.118
3.00REF
][0.150
3.80REF
][0.250
6.35REF
][0.571
14.50 REF
REF
][0.748
19.00 REF
][1.084
27.54REF
][.206
5.24
][0.150
3.81REF
Dimensions (Dims. shown are for reference only. Consult factory for latest prints.)
1000
100
10
1
0.1
100% 200% 300% 400% 500% 600%
TRIP TIME VS. PERCENT OF RATED CURRENT
% of Rated Current
Time in Seconds
-50
0
50
100
150
200
-25 0 25 50 75 100
TEMPERATURE DERATING CURVES
AMBIENT TEMPERATURE IN DEGREES C
Maximum % Hold Current
ATC®CIRCUIT BREAKERS
Auto, Modified, & Manual Reset
SPECIFICATIONS
Single Pole Thermal Type Breakers
Rating: 5-30A, 14VDC; 28VDC (Series 223 & 226).
Interrupt Rating: 150A @ 14VDC (5-10A versions); 225A @ 14VDC (15A
version); 300A @ 14VDC (20A version); 450A @ 14VDC (25-30A versions).
Operating Temperature Rating: –40°F (–40°C) to 185°F (85°C).
Storage Temperature Rating: –40°F (–40°C) to 260°F (125°C).
Materials: UL-Rated 94V-0 thermoplastic housing with gold metal cover
(Type I) or silver metal cover (Type II & III).
Marking: Standard marking includes amp/volt ratings, part number, and
date code. Type III reset buttons are color-coded to amperage ratings.
Push-to-trip option is available on manual reset version. OCR marking is
available.
Termination: Compatible with 280 Type or ATC®fuse blocks.
Compliances: SAE J553.
Terminal Options
*Reset Button Color (223 & 226 only).
ATC®Circuit Breaker Puller
Part Number 32003
Bussmann®ATC TERMINAL CIRCUIT PROTECTION
24 Cooper Bussmann Transportation Products • Phone: 1-888-867-8194 • Website: http://www.coopertp.com
Rating
❏❏
SERIES 227 ATC®CIRCUIT BREAKERS (Low-Profile)
PART NUMBERING SYSTEM
Series
❏❏❏
2 2 7
Marking
❏❏
0 0
DIMENSIONS (Dims. shown are for reference only. Consult factory for latest prints)
0.2"
(0.6)
0.26"
(6.5)
0.57"
(14.6 REF)
0.16"
(4.13)
0.18"
(4.6)
0.25"
(6.4)
0.76"
(19.3)
0.99"
(25.1)
1.18"
(30)
0.57"
(14.6)
28VDC
XXXXX
15A
XXXX
ATC®CIRCUIT BREAKERS
Manual Reset
SPECIFICATIONS
Single Pole Thermal Type Breakers
Rating: 5-30A, 28VDC.
Interrupt Rating: 2000A @ 28VDC.
Operating Temperature Rating: –40°F (–40°C) to
185°F (85°C).
Storage Temperature Rating: –40°F (–40°C) to
260°F (125°C).
Materials: UL-Rated 94V-0 thermoplastic body. Tin-plated cop-
per alloy terminals.
Marking: Cover is color-coded to amperage ratings.
Termination: 5.2mm wide blades compatible with ATC®type
fuse blocks.
Compliances: SAEJ553; SAEJ1171 (ignition protected).
Consult factory for time characteristic curves.
05 – 5 amps [LT. Brown (Tan)]
06 – 6 amps [Moss Green]
75 – 7.5 amps [Brown]
10 – 10 amps [Red]
15 – 15 amps [Blue]
20 – 20 amps [Yellow]
25 – 25 amps [White]
30 – 30 amps [Green]
00-Std. Marking
(Consult factory for special marking.)
Cooper Bussmann Transportation Products • Phone: 1-888-867-8194 • Website: http://www.coopertp.com
Bussmann®
25
MAXI®TERMINAL CIRCUIT PROTECTION
MAXI®BLADE FUSES
MAXI®– Fuse
Fast-Acting
SPECIFICATIONS
Current Rating: 20-80A.
Voltage Rating: 32VDC.
Interrupt Rating: 1,000A @ 32VDC.
Housing Material: UL-Rated 94V-0 thermoplastic.
Terminal Material: Silver-plated zinc alloy.
Marking: Amperage marking is OCR compliant.
Compliances: SAE J1888, ISO 8820-3.
BUSS
MAXI-FUSE®
32V
Z039
60
.67"
(17.02)
1.14"
(29.2)
.85"
(21.6)
.50" (12.7)
.83"
(21.21)
.31"
(8.0)
.35"
(8.9)
.18"
(4.57)
.10"
(2.54)
Part No. Amp Rating Color
BK/MAX-20 20 Yellow
BK/MAX-30 30 Green
BK/MAX-40 40 Orange
BK/MAX-50 50 Red
BK/MAX-60 60 Blue
BK/MAX-70 70 Tan
BK/MAX-80 80 Neutral
DIMENSIONS ( Dims. shown are for reference only. Consult factory for latest prints)
4
10
100
1000
2000
CURRENT IN AMPERES
100
10
1
.1
.01
TIME IN SECONDS
30
AMPERE
RATING
40
50
60
Bussmann®MAXI®TERMINAL CIRCUIT PROTECTION
26 Cooper Bussmann Transportation Products • Phone: 1-888-867-8194 • Website: http://www.coopertp.com
SERIES 19X MAXI®CIRCUIT BREAKERS
PART NUMBERING SYSTEM
Series
❏❏❏
19
191 – Type I, 14 VDC
192 – Type II, 14 VDC
193 – Type III, 12V/28 VDC
194 – Type I, 28 VDC
195 – Type II, 28 VDC
Rating
❏❏
08 – 8 amps
10 – 10 amps
15 – 15 amps
20 – 20 amps
25 – 25 amps
30 – 30 amps
35 – 35 amps
40 – 40 amps
50 – 50 amps (191, 193, 194 only)
Terminal
❏❏
01 – MAXI
®
02 – Wide ATC
®
03 – Long ATC
®
(w/dimple)
04 – Long ATC
®
(no dimple)
Cover
M – Metal*
P – Plastic (193 only)
Button
(193 Series Only)
1 – Black
2 – White
Marking
(Consult factory
for special markings.)
* All breakers have metal cover except 193 series.
Series 19X MAXI®Circuit Breakers
Auto, Manual & Modified Reset
SPECIFICATIONS
Single Pole Thermal Type Breakers
Rating: 8-50A; 14VDC; 28VDC (Series 193, 194, & 195).
Interrupt Rating: 150A @ 14VDC (8-10A versions); 225A @
14VDC (15A version); 300A @ 14VDC (20A version); 450A @
14VDC (25-30A versions); 600A @ 4VDC (35-40A versions);
750A @ 14VDC (50A version).
Operating Temperature Rating: –40°F (–40°C) to
185°F (85°C).
Storage Temperature Rating: –40°F (–40°C) to
260°F (125°C).
Materials: Grey UL-Rated 94V-0 thermoplastic.
Termination: Compatible with fuse blocks accepting MAXI®or
ATC®blade fuses.
Compliances: SAE J553.
04
03
02
01
0.170
(4.32)
0.4100
(10.29)
0.4100
(10.29)
0.290
(7.37)
0.210
(5.33) 0.370
(9.40)
0.170
(4.32)
0.290
(7.37)
0.210
(5.33) 0.370
(9.40)
0.450
(11.43)
0.290
(7.37)
0.330
(8.38)
0.190
(4.83)
0.920
(23.37)
0.670
(17.02) 0.032
(0.81)
0.141
(3.57)
0.500
(12.70)
0.310
(7.87) 0.840
(21.34)
(14VDC only)
0.360
(9.14)
1.150
(29.21)
Reset Button
(Series 193)
DIMENSIONS (Dims. shown are for reference only. Consult factory for latest prints) TERMINAL OPTIONS
500%
500200100403020151050
400%
300%
200%
100%
TIME VS. PERCENT OF RATED CURRENT
TIME IN SECONDS
% 0F RATED CURRENT
150%
100%
50%
0%
% 0F RATED CURRENT
50º 77º100º 150º 200º 250º 300º
(10º)(25º)(38º) (65º) (93º) (121º) (149º)(-18º)
TEMPERATURE IN DEGREES F°
(TEMPERATURE IN DEGREES C°)
TEMPERATURE DERATING CURVES
10 AMPS & BELOW
TYPICAL CURVE
15 AMPS & ABOVE
TYPICAL CURVE
10 AMPS & BELOW
TYPICAL CURVE
15 AMPS & ABOVE
TYPICAL CURVE
Cooper Bussmann Transportation Products • Phone: 1-888-867-8194 • Website: http://www.coopertp.com
Bussmann®
27
INSERTION/EXTRACTION TOOL
SERIES 3200 INSERTION/EXTRACTION TOOL
MINI CB
MINI FUSE
ATC FUSE
ATC CB
.67"
(17.00)
.98"
(25.00)
1.18"
(30.00)
1.18"
(30.00)
1.18"
(30.00) .31"
(7.90)
1.30"
(33.00)
A
A
.24"
(R6.00)
.34"
(8.6)
.39"
(10.00)
.06"
(1.60)
.16"
(4.00)
32000
SECTION A-A
Series 3200
Automotive Fuse and
Circuit Breaker Insertion/Extraction Tool
FEATURES / BENEFITS
• Custom Configurable Design
Get Only the Extractors You Need
• Common Platform for any Style
Eliminates Design Changes When Protection
Requirements Change
• Center Snap-Lock Mounting Hole
Easy Mounting Using Simple Split-Ball Snap-Lock Post
• Positive Stop Locking Action
Tight Grip Allows Devices to be Removed and Inserted
• High Temperature Resilient Nylon 6/6 (105°C)
PART NUMBERING SYSTEM
Series
❏❏❏❏
32 00
Configuration
Top Right Bottom Left
0 – MINI CB MINI FUSE ATC
®
CB ATC
®
FUSE
1 – MINI CB BLANK ATC
®
CB BLANK
2 – MINI CB BLANK MINI FUSE BLANK
3 – ATC
®
CB BLANK ATC
®
FUSE BLANK
DIMENSIONS (Dims. shown are for reference only. Consult factory for latest prints)
SERIES 32013
Series 32013
Automotive Fuse Circuit Breaker Insertion/Extraction Tool
(To be used with Series 32000
Dual Vehicle Electrical Center)
FEATURES / BENEFITS
• Positive Stop Locking Action
Tight Grip Allows Devices to be Removed and Inserted.
• High Temperature Resilient Nylon 6/6 (105°C)
PART NUMBERING SYSTEM
Series
❏❏❏❏❏
32 01 3
MINI CB
ATC CB
.32"
(R8.25)
32001 32002 32003
ATC FUSE
ATC CB
MINI FUSE
MINI CB
Bussmann®FLAT-PAK CIRCUIT PROTECTION
28 Cooper Bussmann Transportation Products • Phone: 1-888-867-8194 • Website: http://www.coopertp.com
SERIES 174 FLAT-PAK CIRCUIT BREAKER
®®
174XX-3X
XXA XXX
BUSSMANN 32 VDC
250 VAC
®®
174XX-3X
XXA XXX
BUSSMANN 32 VDC
250 VAC
®®
174XX-3X
XXA XXX
BUSSMANN 32 VDC
250 VAC
®®
174XX-3X
XXA XXX
BUSSMANN 32VDC
250 VAC
2
5
TERMINAL / BASE STYLES
BUSHING / NECK STYLES BUTTON MARKING OPTIONS
FIGURE A
HARDWARE VARIATIONS
SNAP - ON
SNAP - ON
PLASTIC KNURL NUT
(STANDARD) PALNUT
* PLASTIC BOOT
* ALSO AVAILABLE IN BULK
3/8-24 P/N B151-7135-3
7/16-28 P/N B151-7135-1
RECOMMENDED BUSHING PANEL CUTOUT
FIGURE B
31
UL & CSA
05 TO 30AMP
32
UL & CSA
05-40AMP
33
UL & CSA
05-15 (WIRE)
05-30 (RING)
34
UL & CSA
05-15 (WIRE)
05-30 (RING)
7/16 - 28 THREAD 3/8 - 24 THREAD
7/16 - 28
THREAD 3/8 - 24
THREAD
T
O
R
E
S
E
T
.75"
(19.04) .12"
(3.00)
9.91
(.390)
.44"
(Ø11.10) .38"
(Ø9.52)
.34"
(8.51)
.32"
(R8.1) .63"
(16.13)
.55"
(13.84)
.35"
(9.0)
.35"
(9.0)
.48"
(12.10)
.60"
(1.50)
TYP.
1.11"
(28.30) .19"
(4.83)
.93"
(23.57)
.81"
(20.55)
.42"
(10.67)
.76"
(19.40)
.79"
(19.98)
.20"
(5.19)
.76"
(19.40) .20"
(5.19)
.20"
(5.19)
P
U
S
H
.55"
(14.00)
.79"
(20.11)
PUSH
TO RESET
.40"
(9.00)
2
5
MANUAL RESET CIRCUIT BREAKERS
SPECIFICATIONS
Single Pole Thermal Type Breakers
Applications: Branch circuit protection for multiple power
outlet strips, trucks, RV’s, boats, buses, portable generators,
building equipment, etc.
Rating: 5-40A; 250VAC/32VDC.
Interrupt Rating: 200A @ 250VAC.
Operating Temperature Rating: –40°F (–40°C) to
185°F (85°C).
Storage Temperature Rating: –40°F (–40°C) to
260°F (125°C).
Materials: Grey UL-Rated 94V-0 thermoplastic.
Termination: Threaded or quick-connect options available.
Ingress Protection Rating: IP54 (except at terminals).
Compliances: UL 1077 & CSA 22.2 No. 235 (See individual
terminal styles for specific rating approvals); SAE J553; SAE
J1171 (Ignition Protected).
DIMENSIONS (Dims. shown are for reference only. Consult factory for latest prints)
Cooper Bussmann Transportation Products • Phone: 1-888-867-8194 • Website: http://www.coopertp.com
Bussmann®FLAT-PAK CIRCUIT PROTECTION
29
SERIES 174 FLAT-PAK CIRCUIT BREAKER
PART NUMBERING SYSTEM
Series
❏❏❏
174
174 – Type III
250 VAC/
32VDC
Manual
Reset
Rating
❏❏
3
05 – 5 amps
06 – 6 amps
07 – 7 amps
08 – 8 amps
10 – 10 amps
15 – 15 amps
20 – 20 amps
25 – 25 amps
30 – 30 amps
35 – 35 amps*
40 – 40 amps*
Terminal/
Base
1 – .25" Quick
Connect
2 – 10-32 screw -
90° bend
3 – 6-32 screw -
90° bend
4 – .25" Quick
Connect with
6-32 screw -
90° bend
Bushing/
Neck
1 – 7/16-28
thread
2 – 3/8-24
thread
3 – Snap-on
Button
A – White w/no
marking
B – Red w/no
marking
C – Black w/no
marking**
D – White w/amp
marking
Fig. A
E – White w/amp
marking
Fig. B
F – Red w/amp
marking
Fig. A
G – Red w/amp
marking
Fig. B
Hdwr. Pkg.
1 – Pack bulk
(standard)
2 – Assemble to
bushing
3 – No hardware
included
Bushing Hdwr.
A – White plastic knurl nut,
anti-rotational
B – Black plastic knurl nut,
anti-rotational
C – White plastic knurl nut,
anti-rotational w/ palnut
D – Black plastic knurl nut,
anti-rotational w/ palnut
E – None required for bushing
F – Zinc plated steel palnut
G – Button boot (thread-on)
w/ palnut
P Aluminum knurl nut
& palnut
R – Black aluminum knurl nut
& palnut
S Alum. knurl nut, palnut, black plate
w/ white “push-to-reset”
T Alum. knurl nut, palnut, white plate
w/ black “push-to-reset”
V Alum. knurl nut & white plate w/
black “push-to-reset”
W Alum. knurl nut & black plate w/
white “push-to-reset”
X Aluminum knurl nut & internal tooth
lockwasher
Z – Hex nut & internal tooth lockwasher
Special
Options
❏❏
0 – No hardware
1 – Bulk brass
screws for screw
terminals
2 – Bulk brass
screws and lock-
washers for
screw terminals
3 – Assembled brass
screws for screw
terminals
4 – Assembled brass
screws and lock-
washers for
screw terminals
TEMPERATURE IN DEGREES F°
(TEMPERATURE IN DEGREES C°)
TIME IN SECONDS
% 0F RATED CURRENT
% 0F RATED CURRENT
0°
0 5 10 15 20 30 40 50 100 150 200 400 600
50°77°100°150°200°250°300°
(-18°) (10°) (25°) (38°) (65°) (93°) (121°) (149°)
0%
100%
200%
300%
400%
500%
50%
100%
150%
200%
Temperature Derating Curves for 5-40 Amp. Circuit Breakers
174 SERIES TEMP. VS. CURRENT CURVES
TIME vs. Percent of Rated Current Curves for 5-40 Amp. Circuit Breakers
174 SERIES TRIP CURVES
10 AMP & BELOW
TYPICAL CURVE
COMMON CURVE
ALL VALUES
15 AMP & BELOW
TYPICAL CURVE
**No marking available
on Black buttons
*2 or 3 Style
Terminal Only.
Bussmann®SHORTSTOP®CIRCUIT PROTECTION
30 Cooper Bussmann Transportation Products • Phone: 1-888-867-8194 • Website: http://www.coopertp.com
SERIES 12X SHORTSTOP®CIRCUIT BREAKERS
.69"
(17.5) .69"
(17.5)
.69"
(17.5)
.56"
(14.2)
.56"
(14.2)
.54"
(13.7)
.37" (9.4)
.56"
(14.2)
.66"
(16.8)
.66"
(16.8) .41"
(10.3)
.41"
(10.3)
Two 10-32 studs:
.66" (AUX); .56" (BAT)
A
Two 10-32 studs:
.56" (AUX & BAT)
B
Two 10-32 studs:
.66" (AUX & BAT)
C
Two .25" Q.C.
(AUX & BAT)
D
.41"
(10.3)
.84"
(21.4)
.84"
(21.4)
.56"
(14.2)
.41"
(10.3)
.69"
(17.5)
.69"
(17.5)
.99"
(25.2)
Double .25" Q.C. (AUX);
One 10-32 stud (BAT)
H
Double .25" Q.C. (AUX);
Single .25" Q.C. (BAT)
J
One .25" Q.C. (AUX);
One 10-32 stud (BAT)
E
.99"
(25.2)
.30"
(7.7)
Two .25" Q.C. (AUX & BAT)
Perpendicular
Orientation
Two 10-32 studs
(AUX & BAT)
K
L
1.24"
(31.5)
1.27"
(32.3)
1.27"
(32.3)
1.24"
(31.5)
1.24"
(31.5)
1.24"
(31.5)
1.27"
(32.2) 1.27"
(32.2)
1.56"
(39.6)
1.56"
(39.6)
1.56"
(39.6)
.79"
(20.1)
.79"
(20.1)
.69"
(17.5) .69"
(17.5)
.79"
(20.1)
1.56"
(39.6)
1.56"
(39.6)
.64"
(16.3)
.62"
(15.7)
.69"
(17.5)
.83"
(21.1)
O Bracket
O Bracket
A Bracket
A Bracket
B Bracket C Bracket E Bracket
Series 123
O Bracket w/reset
B Bracket C Bracket
.38" (9.6)
.37" (9.4)
.79"
(20.1)
.38" (9.6)
METAL COVER
PLASTIC COVER
1.27"
(32.3) .83"
(21.1)
.62"
(15.7)
.83"
(21.1)
.37" (9.4)
.83"
(21.1)
.06"
(1.5)
.12" (3.0)
dia. boss
.62" (15.7)
Ref. (Typ)
w/base attached
Reset button*
BAT AUX
BATAUX
BAT AUX
( * Reset on BAT side)
PART NUMBERING SYSTEM
Series
❏❏❏
12
121 – Type I,
14 VDC
122 – Type II,
14 VDC
123 – Type III,
28 VDC
124 – Type I,
28 VDC
125 – Type II,
28 VDC
Terminal
A – Two 10-32 studs;
.66 (Aux), .56 (Bat)
B Two 10-32 studs;
.56 (Aux & Bat)
C – Two 10-32 studs;
.66 (Aux & Bat)
***D – Two .250 QC;
(Aux & Bat)
** H – One 10-32 stud
.56 (Bat), Double
.250 QC (Aux)
L – Two 10-32 studs; .37
(Aux & Bat)
Rating
❏❏
05 – 5 amps
08 – 8 amps
10 – 10 amps
12 – 12 amps
15 – 15 amps
20 – 20 amps
25 – 25 amps
30 – 30 amps
35 – 35 amps
40 – 40 amps
50 – 50 amps
Bracket
0 – No bracket
A – Bracket
B – Bracket
C – Bracket
E – Bracket
(plastic only)
Mtg. Holes
0 – No bracket
1 – .140 dia.
2 – .196 dia.
3 – .237 dia.
(metal only)
4 – .265 dia.
(plastic only)
5 – .228 dia.
(plastic only)
6 – .221 dia.
(metal only)
Cover*
M – Metal*
P – Plastic*
Options
❏❏
01 – Waterproof
(metal
covers only)
02 – Splashproof
(optional on
metal covers -
add 02 suffix;
std. on plastic
covers - omit
02 suffix.)
Hardware
❏❏
WA – Whiz-lock nut
assembled
WB – Whiz-lock
nut bulk
HA – Nut & lock
washer
assembled
HB – Nut & lock
washer bulk
KA – Keps lock nut
assembled
KB – Keps lock
nut bulk
*Series 123 available in plastic cover only. Series 122 & 125 available in metal cover only. **40A maximum ***30A maximum
500%
500200100403020151050
400%
300%
200%
100%
TIME VS. PERCENT OF RATED CURRENT
TIME IN SECONDS
% 0F RATED CURRENT
150%
100%
50%
0%
% 0F RATED CURRENT
50º 77º100º 150º 200º 250º 300º
(10º)(25º)(38º) (65º) (93º) (121º) (149º)(-18º)
TEMPERATURE IN DEGREES F°
(TEMPERATURE IN DEGREES C°)
TEMPERATURE DERATING CURVES
10 AMPS & BELOW
TYPICAL CURVE
15 AMPS & ABOVE
TYPICAL CURVE
10 AMPS & BELOW
TYPICAL CURVE
15 AMPS & ABOVE
TYPICAL CURVE
HA / HB
Hex Nut
#10-32
Keps Lock Nut
#10-32
Whiz Lock
#10-32
Lock Washer
WA / WB KA / KB
TERMINAL OPTIONS
COVER & BRACKET OPTIONS (Dims. shown are for reference only. Consult factory for latest prints)
HARDWARE
AUTO, MANUAL & MODIFIED RESET CIRCUIT BREAKERS
SPECIFICATIONS
Single Pole Thermal Type Breakers
Applications: Battery chargers, trucks, buses, RV’s, trolling motors, etc.
Rating: 5-50A, 14VDC; 28VDC (Series 123, 124, & 125).
Interrupt Rating: Main Circuit Protection: 1.5kA @ 12VDC (Series 193 w/plastic cover);
Branch Circuit Protection: 2.5kA @ 12VDC (Series 121 & 124 -01 sealed & Series 123
w/plastic cover).
Operating Temperature Rating: –40°F (–40°C) to 185°F (85°C).
Storage Temperature Rating: –40°F (–40°C) to 260°F (125°C).
Materials: Black UL-Rated thermoplastic body (thermoset for Type II body & buttons); Cover
is grey thermoplastic or steel-Type l gold, Type ll silver.
Marking: Custom marking available. Consult factory for options.
Termination: #10-32 thread and quick-connect options available.
Torque Rating: 24in-lb (2.7Nm) max.
Mounting Torque Rating: Plastic cover - 15in-lb (1.7Nm); Metal cover - 30in-lb (3.4Nm).
Ingress Protection Rating: IP66 on plastic cover version only (except for terminals).
Compliances: SAE J553; SAE J1171 (consult factory for Ignition Protection ratings).
PART NUMBERING SYSTEM
Series
❏❏❏
2 5
Rating
❏❏
10 – 10 amps
15 – 15 amps
20 – 20 amps
25 – 25 amps
30 – 30 amps
35 – 35 amps
40 – 40 amps
50 – 50 amps
Mounting Holes
A – Thru-hole Insert (#10 Clearance)
B – #8-32 Threaded Inserts
Hardware
0 – No nuts
1 – Nuts Installed
2 – Nuts bulk
251 – Type I, 32V
254 – Type III, 32V
255 – Type III w/push-
to-trip option, 32V
Cooper Bussmann Transportation Products • Phone: 1-888-867-8194 • Website: http://www.coopertp.com
Bussmann®MID-RANGE CIRCUIT PROTECTION
31
SERIES 25X MID-RANGE CIRCUIT BREAKER
(2) #10-32 CLEARANCE HOLE
OR #8-32 CLEARANCE HOLE
IF USING THREADED INSERTS
Ø31.75"
[Ø1.25]
19.99"
[0.787]
39.98"
[1.574]
21.50"
[0.85]
RESET LEVER
(series 254 & 255)
#10-32 EXTERNAL THREAD
MOUNTING OPTIONS
(255 series)
TRIP BUTTON
27.80"
[1.09]
5.00"
[0.20]
33.80"
[1.33]
18.50"
[0.73]
39.98"
[1.57]
17.33"
[0.68]
55.73"
[2.19]
37.00"
[1.46]
MANUAL RESET CIRCUIT BREAKERS
Automatic, Manual, & Manual W/ Push-to-Trip
SPECIFICATIONS
Single Pole Thermal Type Breakers
Applications: This unit is external ignition protected and weatherproof. It is typically used in
DC power systems in marine applications (as a main or branch circuit breaker), truck, bus and
RV systems, add-on protection for accessories, etc.
Rating: 10-50A, 32VDC.
Interrupt Rating: Circuit Protection (2.5kA) per ABYC E-11.
Operating Temperature Rating: –40°F (–40°C) to 185°F (85°C).
Storage Temperature Rating: –40°F (–40°C) to 260°F (125°C).
Materials: Black UL-Rated 94V-0 thermoset plastic body. Cover, lever, and button are UL-
Rated 94V-0 thermoplastic. Cover has a black thermoplastic elastomer overmold.
Marking: Standard marking includes amp/volt ratings, part numbers, and “SAE Type B.”
Termination: #10-32 threaded studs.
Torque Rating: 24in-lb (2.7Nm) max.
Mounting Torque Rating: Panel mount with either #8-32 threaded inserts or #10 clearance
holes. 18in-lb (2.0Nm) max.
Ingress Protection Rating: IP66
Features / Options: Series 254 & 255 have a unique reset mechanism which provides a
visual indication of tripped condition. Series 255 also features a push-to-trip option.
Compliances: SAE J553; ABYC E-11; SAE J1171 (Ignition Protected).
DIMENSIONS (Dims. shown are for reference only. Consult factory for latest prints)
TRIP TIME VS. PERCENT OF RATED CURRENT
% OF RATED CURRENT
100% 200% 300% 400% 500% 600%
1000
100
10
1
0.1
TIME IN SECONDS
-40 -20 0 20 40 60 80
AMBIENT TEMPERATURE IN DEGREE C
TEMPERATURE DERATING CURVE
200
150
100
50
0
MAXIMUM % HOLD CURRENT
Bussmann®HI-AMP CIRCUIT PROTECTION
32 Cooper Bussmann Transportation Products • Phone: 1-888-867-8194 • Website: http://www.coopertp.com
SERIES 18X HI-AMP CIRCUIT BREAKER
PART NUMBERING SYSTEM
Series
❏❏❏
18
181 – Type I, 30V
183 – Type II*, 30V
184 – Type III, 48V
185 – Type III-PTT, 48V
Rating
❏❏❏
025 – 25 amps
030 – 30 amps
035 – 35 amps
040 – 40 amps
050 – 50 amps
060 – 60 amps
070 – 70 amps
080 – 80 amps
090 – 90 amps
100 – 100 amps
110 – 110 amps
120 – 120 amps
135 – 135 amps
150 – 150 amps
Mounting
F – Surface Mount
P – Panel Mount
Terminal Hdwr.
❏❏
00 – Ship w/o nuts
01 – Sems nuts installed
02 – Sems nuts shipped bulk
03 – Stainless Steel Std. nuts &
washers installed
04 – Stainless Steel Std. nuts &
washers shipped bulk
07 – Flange gasket & Sems nuts installed
(Panel Mount Only)
08 – Threaded insert and Sems nuts
installed
12 – Stainless steel nuts and lockwashers
installed
13 – Stainless steel Sems nut installed
Marking
❏❏
0 – Blank cover
1 – Standard Marking; Part Number,
Amp Rating
181, 184, 185 Series - Top Surface
183 Series - Side Surface
S – Standard Ignition Protected
Marking
(Consult factory for special markings.)
600%
500%
500200100403020151050
400%
300%
200%
200%
150%
100%
50%
0%
100%
TIME VS. PERCENT OF RATED CURRENT
TIME IN SECONDS
% 0F RATED CURRENT % 0F RATED CURRENT
-50º 50º 77º 100º 150º 200º 250º
(-45º) (10º)(25º)(38º) (65º) (93º) (121º)(-18º)
TEMPERATURE IN DEGREES F°
(TEMPERATURE IN DEGREES C°)
TEMPERATURE DERATING CURVES
RESET
1.05
(26.67)
2.23
(56.64)
2.89
(73.41)
1.44
(36.58) 1.79
(45.47)
.66
(16.76)
1.09*
(27.69)
.40
(10.16)
1.90
(48.26)
Stud insulators
.26 (6.60) dia.
Mtg.holes (2)
Reset lever
(Shown in
operating
position series
184/185)
.26 (6.60) dia.
Mtg.holes (2) Reset lever
(Shown tripped)
1/4-28 Studs
Molded
cover
Molded
cover
*Overall heights of
Series 181 &183
Trip button (Series 185)
.57
(14.49) 1.06
(26.92)
.31
(7.87)
.89 (22.61)
1.44*
(36.58)
Tamper proof
cover
1.90
(48.26)
2.91
(73.91) 2.41
(61.21) 1.54
(39.12)
Surface Mount Panel Mount
*183 Available in Panel
Mount Only (Coverless)
DIMENSIONS (Dims. shown are for reference only. Consult factory for latest prints)
Flange mount
gasket for
thru-wall
applications
(option 07)
AUTO, MANUAL & SWITCHABLE RESET CIRCUIT BREAKERS
SPECIFICATIONS
Single Pole Thermal Type Breakers
Applications: Typically used in auxiliary and accessory circuits in truck, bus, RV and
marine systems. Others include battery chargers and DC audio systems. Series 181,
184 & 185 are sealed for engine compartment and bilge area applications.
Rating: 25-150A, 30VDC; 48VDC (Series 184 & 185).
Interrupt Rating: 3,000A @ 30VDC.
Operating Temperature Rating: –25°F (–32°C) to 180°F (82°C).
Storage Temperature Rating: –30°F (–34°C) to 300°F (149°C).
Materials: Black UL-Rated 94V-0 thermoset plastic. Thermoplastic elastomer stud
insulators are provided on covered units with F-style (surface-mount) bases.
Marking: Standard marking includes amp ratings and part numbers. Custom markings
also available.
Termination: 1/4-28 threaded studs.
Torque Rating: 50in-lb (5.6Nm) max.
Mounting Torque Rating: Panel or surface-mount options; 50in-lb (5.6Nm) max.
Threaded insert option has a max torque of 25in-lb (2.8Nm).
Ingress Protection Rating: IP67.
Features / Options: Series 184 & 185 have a unique reset mechanism which provides
visual indication of tripped condition. Series 185 also features a push-to-trip option.
Compliances: SAE J1625; ABYC E-11; CE; SAE J1171 (Ignition Protected).
Cooper Bussmann Transportation Products • Phone: 1-888-867-8194 • Website: http://www.coopertp.com
Bussmann®MARINE-RATED CIRCUIT PROTECTION
33
SERIES 187 MARINE RATED CIRCUIT BREAKER (MRCB)
PART NUMBERING SYSTEM
Series
❏❏❏
18 7
187 – Manual Reset - Switching
Style Circuit Breaker
Rating
❏❏❏
025 – 25 amps
030 – 30 amps
035 – 35 amps
040 – 40 amps
050 – 50 amps
060 – 60 amps
070 – 70 amps
080 – 80 amps
100 – 100 amps
110 – 110 amps
120 – 120 amps
135 – 135 amps
150 – 150 amps
Mounting
F – Surface mount
P – Panel mount
Hardware
❏❏
00 – No hardware
03 – Stainless nuts &
lockwashers - installed
on studs
04 – Stainless nuts &
lockwashers - supplied
bulk packed
Marking
1 – Standard marking; Part Number,
Amp Rating
(Consult factory for special marking options.)
MANUAL RESET CIRCUIT BREAKERS WITH SWITCH FUNCTION
SPECIFICATIONS
Single Pole Thermal Type Breakers
Applications: Typically used in DC power systems in marine applications
(as a main or branch circuit breaker), truck and bus systems, RV systems,
add-on protection for accessories, lift gates, etc. This unit is external igni-
tion protected and weatherproof.
Rating: 25-150A, 48VDC.
Interrupt Rating: Main Breaker Protection Interrupt Rating (5kA @
12VDC). (Consult factory for higher voltage interrupt ratings.)
Operating Temperature Rating: –40°F (–40°C) to 185°F (85°C).
Storage Temperature Rating: –40°F (–40°C) to 260°F (125°C).
Materials: Black UL-Rated 94V-0 thermoset plastic body. Cover and lever
are UL-Rated 94V-0 thermoplastic.
Marking: Standard marking includes amp/volt ratings. Custom markings
also available.
Termination: 5/16-18 threaded studs.
Torque Rating: 75in-lbs (8.5Nm) max.
Mounting Torque Rating: Panel or surface-mount options; 50in-lb (5.6
Nm) max.
Ingress Protection Rating: IP66.
Features / Options: A manual reset circuit breaker with On-Off switch
capability.
Compliances: ABYC E-11; CE; SAE J1171 (Ignition Protected).
Consult factory for time characteristic curves.
DIMENSIONS (Dims. are shown for reference only. Consult factory for latest prints)
R
MRCB
BUSS
TRIP
OFF
RESET
48V DC MAX
25A
IGNITION PROTECTED
WEATHERPROOF
69.85
[2.750]
28.84
[1.135]
ON 16.76
[.660]
26.81
[1.056]
53.47
[2.105]
57.68
[2.271] 2.24
[56.8]
2.32
[59.0]
1.06
[27.1]
1.64
[41.6]
1.72
[43.8]
2.72
[69.0]
.16
[3.9]
1.46
[37.1]
.73
[18.6]
3.44
[87.3]
60.34
[2.375]
58.15
[2.289]
MRCB
25A
48V DC MAX
WEATHERPROOF
IGNITION PROTECTED
RESET
BUSS
OFF
ON
Panel Mount Base Mount
Bussmann®BOLT-IN FUSE PROTECTION
34 Cooper Bussmann Transportation Products • Phone: 1-888-867-8194 • Website: http://www.coopertp.com
AMI SERIES
0.8
(0.03)
9.5
(0.37)
12.0
(0.47)
16.0
(0.63)
30.0
(1.18)
41.0
(1.61)
6.0
(0.24)
Ø5.5
(Ø0.22)
PART NUMBERING SYSTEM
Series
❏❏❏❏❏❏
B K / A M I
Rating
❏❏❏
030 – 30 amps (orange)
040 – 40 amps (lt. green)
050 – 50 amps (red)
060 – 60 amps (yellow)
070 – 70 amps (brown)
080 – 80 amps (white)
100 – 100 amps (blue)
125 – 125 amps (pink)
150 – 150 amps (gray)
DIMENSIONS (Dims. shown are for reference only. Consult factory for latest prints)
BOLT IN AUTOMOTIVE FUSES
SPECIFICATIONS:
Applications: Power distribution protection for
automotive systems. Consult factory for available fuse-
holders.
Current Rating: 30-150A.
Voltage Rating: 32VDC.*
Interrupt Rating: 2000A @ 32VDC.
Housing Material: UL-Rated 94V-0 thermoplastic.
Terminal Material: Tin-plated brass.
Mounting: Max torque of 35in-lb (4Nm).
Marking: Color-coded housings for each amperage.
*Consult factory for higher voltage fuses.
Maximum
3600 s
100 s
10 s
1 s
Minimum
100 hrs
4 hrs
90 s
5 s
0.3 s
0.1 s
% of
Rating
100
110
150
200
300
500
Opening Time
TIME-CURRENT SPECIFICATIONS
10000
1000
100
10
1
.01
0.01
TIME IN SECONDS
CURRENT IN AMPERES
AMPERE RATING
50
80
100
10 100 1000 10000
Cooper Bussmann Transportation Products • Phone: 1-888-867-8194 • Website: http://www.coopertp.com
Bussmann®BOLT-IN FUSE PROTECTION
35
AMG SERIES
BOLT IN AUTOMOTIVE FUSES
SPECIFICATIONS:
Applications: For high current applications. Use
with Bussmann HMG or FMG fuseholders. (See
pages 12-13.)
Current Rating: 100-300A.
Voltage Rating: 32VDC.*
Interrupt Rating: 1,000A @ 32VDC.
Housing Material: UL-Rated 94V-0
thermoplastic.
Terminal Material: Copper.
Mounting: M8 or 5/16-18 or less studs on 2.00 in
(50.8mm) centers.
Marking: Color-coded amperage ratings.
*Consult factory for higher voltage fuses.
68.40"
(2.693)
29.20"
(1.150)
1.52"
(0.06)
9.00"
(0.354)
29.20"
(1.150)
15.40"
(0.606)
50.80"
(2.000)
12.18"
(0.480)
Ø8.60"
(0.339)
PART NUMBERING SYSTEM
Series
❏❏❏❏❏❏
B K / A M G
Rating
❏❏❏
100 – 100 amps
125 – 125 amps
150 – 150 amps
175 – 175 amps
200 – 200 amps
225 – 225 amps
250 – 250 amps
300 – 300 amps
DIMENSIONS (Dims. are shown for reference only. Consult factory for latest prints)
150
175
200
250
Maximum
1800 s
30 s
5s
1 s
Minimum
100 hrs
120 s
1 s
0.1 s
0.02 s
% of
Rating
100
135
200
350
600
Opening Time
TIME-CURRENT SPECIFICATIONS
Bussmann®
36 Cooper Bussmann Transportation Products • Phone: 1-888-867-8194 • Website: http://www.coopertp.com
NOTES
Cooper Bussmann Transportation Products • Phone: 1-888-867-8194 • Website: http://www.coopertp.com
Bussmann®
37
NOTES
Transportation Products
Bussmann®
Bussmann
Cooper Bussmann
P. O. Box 14460
St. Louis, Missouri 63178-4460
Telephone: 636-394-2877
Facsimile: 800-544-2570
Cooper Bussmann
Transportation Products
175 Hansen Court
Wood Dale, IL 60191-1145
Telephone: 888-867-8194
Facsimile: 800-832-9873
European Headquarters
Cooper Bussmann U.K. Ltd.
Burton-on-the-Wolds
Leicestershire LE12 5 TH
England
Telephone: 44-1509-882737
Facsimile: 44-1509-882786
Cooper Bussmann
Thomas A. Edison R&D
Center (Shanghai)Co.,Ltd.
955 Sheng Li Road
Heqing Pudong, Shanghai
China 201201
Telephone: +8621 2899 3747
Facsimile: +8621 2899 3997
Cooper Electrical Australia
205-209 Woodpark Road
P.O. Box 2577
Smithfield, Sydney
NSW 2163, Australia
Telephone: 61-2-8787-2700
Facsimile: 61-2-9609-2342
Bussmann do Brazil Ltd.
Rodovia Santos Dumont, Km 23
Cruz das Almas - 13.300-000
Caixa Postal 095
Itu-Sao Paulo Brazil
Telephone: 55-11-4024-8400
Facsimile: 55-11-4024-8424
Bussmann Transportation
Products Authorized Sales
Office, Mexico
Kruvand and Associates
1202 Richardson Drive,
Suite 113
Richardson, Texas 75080
Telephone: 972-437-3355
Facsimile: 972-680-8854
Cooper Bussmann India Ltd.
EVR Street, Sedarapet
Pondicherry - 605 111 India
Telephone: 91-80-227-0893
Facsimile: 91-80-224-5725
COOPER BUSSMANN • 175 HANSEN COURT • WOOD DALE, IL 60191-1145
CUSTOMER SATISFACTION PHONE: (888) 867-8194 • TECHNICAL SUPPORT PHONE: (888) 478-8324 • FAX: (800) 832-9873
WEB SITE: www.coopertp.com
REORDER # 7003 Revised 3/06
Solutions for the Transportation Industry
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Eaton:
C1925 C2791 C2791-R C4559-10 C4559-2 C4559-4 C4559-6 C4559-8 C5237-1 C5237-5 C6344-2 JB3816-2
JB3816-3 C4044-1 C4044-1R