Isolated Input and Output Terminals
Separates Control Circuits from
Load Circuits.
Finger-Safe
Protects Operators
from Live Circuits.
2-Way Side or DIN Rail Mounting System
Retrofits Existing Panel Mounting and
35 mm DIN Rail.
Mating Hold-Down Clips Available
Secures Relay to Socket.
Slim Design
Minimizes Space
on DIN Rail.
Modules
Allows for Optional
Protection or LED Modules
to be Used With Sockets.
I.D. Tag
/
Write-On P
l
astic La
b
e
l
Used for Custom Identification
of Circuits.
DIN Rail End Clip
Locking Screw Keeps
a Snug DIN Rail System
by Eliminating Sliding
Sockets.
Internal Coil Bus
Jumper System
Allows Connection to
Adjacent Sockets Without
Additional Wiring.
I.D. Tag/Write-On Plastic Label
Used for Identification of Relays
in Multi-Relay Circuits.
DIN Rail
35 mm Extruded Aluminum Rail.
Designed to Work With Most Sockets.
Pre-punched for Quick Installation.
The Complete
System Solution!
• Offers a “one stop solution” for
your power management system.
• Variety of contact congurations
and materials to meet your
switching needs.
• Plug-In switching capabilities
from 10mA to 20 Amps.
• A variety of Feature Codes and
operation combinations avail-
able for all budgets.
• Ejector clips, ribbed relay hous-
ings
and space-saving sockets
allow for easy removal from
crowded DIN rails.
• Color and appearance designed
for high visibility in all environ-
ments.
• Wiring diagrams include NEMA
and IEC standards.
• Engineering availability allows
for customized relay solutions.
• Internal Coil Bus Jumper
System reduces the number
of wires required for hook-up
to adjacent sockets.
SECTION 2
Advantages of a Finger-Safe, Ice Cube Socket System
Magnecraft Solution Guide 105A
Magnecraft Solution Guide 105A
2/2
Isolated Input and Output Terminals
Separates Control Circuits from
Load Circuits.
Finger-Safe
Protects Operators
from Live Circuits.
2-Way Side or DIN Rail Mounting System
Retrofits Existing Panel Mounting and
35 mm DIN Rail.
Mating Hold-Down Clips Available
Secures Relay to Socket.
Slim Design
Minimizes Space
on DIN Rail.
Modules
Allows for Optional
Protection or LED Modules
to be Used With Sockets.
I.D. Tag
/
Write-On P
l
astic La
b
e
l
Used for Custom Identification
of Circuits.
DIN Rail End Clip
Locking Screw Keeps
a Snug DIN Rail System
by Eliminating Sliding
Sockets.
Internal Coil Bus
Jumper System
Allows Connection to
Adjacent Sockets Without
Additional Wiring.
I.D. Tag/Write-On Plastic Label
Used for Identification of Relays
in Multi-Relay Circuits.
DIN Rail
35 mm Extruded Aluminum Rail.
Designed to Work With Most Sockets.
Pre-punched for Quick Installation.
The 700 series sockets have
the perfect mix of historical
Magnecraft socket quality
combined with a dynamic
arsenal of options. When
mated with the Magnecraft
relays and accessories, these
RoHS compliant sockets
provide a complete modular
system that will meet all your
plug-in relay requirements in
a package that is both visually
appealing and functionally
outstanding resulting in a
Complete Solution.
SECTION 2
Magnecraft Solution Guide 105A
Magnecraft Solution Guide 105A 2/3
NEW
NEW
NEW
NEW
NEW
BOLD-FACED PART NUMBERS ARE NORMALLY STOCKED
SECTION 2
70-782EL14-1 Socket/10 Amp Rating, 300 Volts
General Specifications
Characteristics
Number of Terminals
Electrical Rating
Nominal Voltage Rating
Nominal Current Rating
Dielectric Strength
Output to Adjacent Output Terminals
Output to Input Terminals
Terminals to Rail / Chassis
Temperature
Operating Range:
Storage Range:
Construction
Protection Category (Finger-Safe)
Internal Metal Tracks
Screw Terminals
Screw Style
Screw size
Screw Torque 3.5 mm (Maximum)
Miscellaneous
Socket Mounting:
Wire Size Capacity (Maximum)
Soild Cu
Stranded Cu
Wire Connection Method
DIN Rail Mounting
Chassis Mount Screw Torque
Flamability Rating
Body Color
DIN Locking Method
Product Certification
Conformance
Weight
Units
Volts
Amps
V rms
V rms
V rms
°C
°C
EN 60529
mm
Lb-in / Nm
EN 60204-1
AWG, mm2
AWG, mm2
EN 60715
Lb-in / Nm
Class
grams
Value
14
300
10
3000
3000
3000
- 40 to + 80
- 40 to + 105
IP 20
Copper Alloy, Zinc Plated
Steel, Zinc Plated
Combination Head,
M3
7 / 0.8
Din / Panel
AWG mm2
16 / 18 (2) 1.5 /0.75 (2)
16 / 18 (2) 1.5 / 0.75 (2)
Elevator
35mm
7 / 0.8
94V-0
Light Gray
Red Plastic Locking Clip
UL, CSA
CE, RoHS
62
Standard Part Number
70-782EL14-1
Description
14-Pin Ice Cube, Logic Style, DIN Panel Mount
with Elevator Terminals, Module Compatible.
WHITE
UL Recognized
File No. E70550
Certified
40787
Module Compatible
Mating Hold-Down
Clips Available
Isolated Input
Terminals
Flip-Up I.D. Tag
Write-On Plastic Label
Side Panel or DIN Rail
Mounting System
Internal Coil Bus
Jumper System
Ink Marked Terminals
for Easy Identification
Finger-Safe Terminals Protect
Operator from Live Circuits.
Meets IP-20
(UL 508)
Magnecraft Solution Guide 105A
Magnecraft Solution Guide 105A
2/18
A2
14 13
INPUT
A1
44
41
42
4
8
12
2
32
3
22 12
1
14
6
34
7
24
5
21
10
31
11
11
9
1
2
3
4
5
6
7
8
9
10
11
12
14 13
0.9
(22)
1.06
(25.4)
(7)
(70)
(52)
2.75
2.04
(19)
0.27
(81)
(61)
2.4
0.74
318
3.11
(79)
(85)
3.34
(38)
1.49
0.2
(5.6)
MODULE
INPUT
COM
INPUT
N.O.
N.C.
1
A1
12
5
9
11
14
INPUT
A2
14
3
4
7
8
11
12
32
42
41 31
34
44
13
2
6
10
22
21
24
NEMA:
IEC:
IEC
NEMA
Optional Mating Accessories
782 Relay
Wiring Diagram
Top View
16-1342
16-782PC-1
Plastic Hold-Down Clip
See Section 3 p.8-11
16-782PC-1
16-700ST-1
16-700DIN
16-DCLIP-170-BSM 16-782FT-116-782SC
16-782CBJ-1
TDR782 Relay 16-TDR782SC
SECTION 2
www.magnecraft.com 847-441-2540
Standard Part Number
782XDX1, 2, 3 & 782H
16-782PC-1
16-700ST-1
16-782SC
16-1342
TDR782XDX
16-TDR782SC
70-BSM
16-782FT-1
16-782CBJ-1
16-700DIN
16-DCLIP-1
Description
Relay
Plastic Hold-Down Ejector Clip for 782
Plastic Snap-On I.D. Tag
Metal Hold-Down Clip for 782
Metal Hold-Down Clip/782H Relay Only
Relay
Metal Hold-Down Clip for TDR782
Module
Plastic I.D. Tag
Coil Bus Jumper
Metal DIN Rail
DIN Rail Locking Clip
Catalog Location
Section 1 p.16-17, 42-43
Section 3 p.8-11
Section 3 p.12
Section 3 p.8-11
Section 3 p.8-11
Section 5 p.14-17
Section 3 p.8-11
Section 3 p.6-7
Section 3 p.12
Section 3 p.13
Section 3 p.19
Section 3 p.19
Magnecraft Solution Guide 105A
Magnecraft Solution Guide 105A
2/19