Catalog 1308242 Issued 3-03 P&B CK series Mid-Priced CMOS IC Time Delay Relay * Choice of timing modes - Delay on operate - Delay on release - Delay on dropout (no input required during timing) - Interval on * Knob or resistor adjustable types * 10A output relay with DPDT contacts * Various models time from 0.1 to 180 sec. File E22575 File LR15734 Users should thoroughly review the technical data before selecting a product part number. It is recommended that user also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. Contact Data @ 25C Timing Modes Delay on operate - Delay period begins when input voltage is applied. At the end of the delay period, the relay will operate and will not release until input voltage is removed. Reset occurs when input voltage is reapplied. ON OFF ON OFF INPUT VOLTAGE N.O. RELAY CONTACTS TIME Delay on release - Input voltage must be applied continuously to operate the internal relay. When the control switch is closed, the relay energizes. When the control switch is opened, timing begins. When timing is complete, the relay will de-energize. Time may be reset to zero during timing by closing the control switch. ON OFF N.O. RELAY CONTACTS ON OFF CONTROL SWITCH TIME Delay on dropout - The relay operates immediately upon application of input voltage. Timing begins when input voltage is removed. When timing is complete, the relay will de-energize. Reset occurs when input voltage is reapplied. ON OFF ON OFF INPUT VOLTAGE N.O. RELAY CONTACTS TIME Interval on (with control switch) - Input voltage must be applied continuously to operate the internal relay. The relay energizes and timing begins when the external switch is closed. At the end of the time delay period the relay will de-energize. Reset is accomplished by opening and reclosing the control switch. ON OFF N.O. RELAY CONTACTS ON OFF TIME Input Data @ 25C Voltage: 24 & 120VAC and 12 & 24VDC. Power Requirement: AC Types: Typically less than 3 VA. DC Types: Typically less than 3 W. Initiate Time: Delay on dropout timers must have input voltage applied for a minimum of three seconds for dropout function to be guaranteed. Transient Protection: Yes. Reverse Voltage Protection: Yes. Input Voltages & Limits @ 25C Voltage Type Nominal Voltage Minimum Voltage Maximum Voltage AC 24 120 12 24 20 105 11 20 28 130 13 32 DC Environmental Data Timing Ranges: From 0.1 to 180 sec. Timing Adjustment: External resistor and knob adjustable. Tolerance (for AC units add 1/2 cycle 60 Hz.): Knob Adj. Types:-0, +20% of max. specified at high end of timing range; min. specified, or less, at low end. Fixed Types: 5%. Res. Adj. Types: 5% at high end of timing range; min. specified, or less, at low end. Delta Time (for AC units add 1 cycle 60 Hz.): 10%. Repeatability (for AC units add 1 cycle 60 Hz.): 2%. Release Time: 60 ms, typ.; 100 ms, max. Recycle Time: 60 ms, typ.; 100 ms, max. Dimensions are shown for Between Open Contacts: 500V rms, 60 Hz. Between All Other Conductors: 500V rms, 60 Hz. Timing Specifications 1224 reference purposes only. Initial Dielectric Strength Note: DC voltage must be filtered (5% p-p ripple max. at nom. voltage). AC models will operate on 50 or 60 Hz. CONTROL SWITCH Arrangements: 2 Form C (DPDT). Material: Silver-cadmium oxide alloy. Rating: 10A @ 30VDC or 277VAC, resistive; 1/2 HP @ 250VAC; 1/3 HP @ 120VAC. Expected Mechanical Life: 10 million operations. Expected Electrical Life: 100,000 operations, min., at rated load. Dimensions are in inches over (millimeters) unless otherwise specified. Temperature Range: Storage: -55C to +85C. Operating: -10C to +55C. Mechanical Data Termination: 8- or 11-pin octal style plug. Enclosure: White plastic case. Knob adjustable types have dial scale for reference only. Sockets: Models with 8-pin base fit either 27E122 or 27E891 (snap-on) screw terminal sockets. 11-pin types fit either 27E123 or 27E892 (snap-on) screw terminal sockets. Weight: 6 oz. (170g) approximately. Specifications and availability subject to change. www.tycoelectronics.com Technical support: Refer to inside back cover. Catalog 1308242 Issued 3-03 P&B Ordering Information - Authorized distributors are more likely to stock boldface items listed below. Delay On Release Models Delay On Operate Models Voltage Time 24VAC 0.1 to 10 Sec. 120VAC 0.1 to 10 Sec. 0.6 to 60 Sec. 1.2 to 120 Sec. 1.8 to 180 Sec. Adjustment Wiring Dia. Part Number Knob 1 CKB-38-30010 Knob 1 CKB-38-70010 CKB-38-70060 CKB-38-70120 CKB-38-70180 120VAC 0.1 to 10 Sec. Resistor 2 CKF-38-70010 12VDC 0.1 to 10 Sec. Knob 1 CKD-38-20010 Voltage Time 120VAC 0.1 to 10 Sec. 0.6 to 60 Sec. 1.8 to 180 Sec. Adjustment Wiring Dia. Part Number Knob 3 CKB-38-78010 CKB-38-78060 CKB-38-78180 120VAC 24VDC 0.1 to 10 Sec. Resistor 4 CKF-38-78010 0.1 to 10 Sec. Resistor 4 CKH-38-38010 Adjustment Wiring Dia. Part Number Knob 1 CKB-38-37010 CKB-38-37060 Knob 1 Adjustment Wiring Dia. Part Number Knob 3 CKB-38-79010 Delay On Dropout Models Voltage 24VAC 120VAC Time 0.1 to 10 Sec. 0.6 to 60 Sec. 0.1 to 10 Sec. 0.6 to 60 Sec. 1.2 to 120 Sec. CKB-38-77010 CKB-38-77060 CKB-38-77120 Interval On Models Voltage Time 120VAC 0.1 to 10 Sec. Outline Dimensions 2.406 MAX. (61.1) 2.937 MAX. (74.6) .56 (14.2) .60 (15.2) 1.781 MAX. (45.2) Wiring Diagrams - Bottom Views (pins numbered clockwise from keyway) EXTERNAL RESISTOR EXTERNAL RESISTOR INPUT (DC POLARITY INDICATED)** Fig.1 8 Pin Fig. 2 11 Pin Fig. 3 11 Pin _ + INPUT (DC POLARITY INDICATED)** + + CONTINUOUS SUPPLY INPUT (DC POLARITY INDICATED)** _ + _ EXTERNAL CONTROL SWITCH* _ CONTINUOUS SUPPLY INPUT (DC POLARITY INDICATED)** Fig. 4 11 Pin EXTERNAL CONTROL SWITCH* * If control switch is closed when power is applied, relay will immediately energize. A 50 millisecond minimum switch closure is required. IMPORTANT: A dry circuit switch is recommended. A "dry circuit" switch is one rated to reliably switch currents of less than 50mA. Use of a switch rated for other than dry circuit may result in failure of the time delay relay to function properly. ** Note: Input polarity for DC operation. For most reliable operation on AC, connect high side to "+" and low side to "-". External Resistor Chart See External Resistor Selection Charts at beginning of Time Delay Relay section of this Databook. Dimensions are shown for reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. Specifications and availability subject to change. www.tycoelectronics.com Technical support: 1225 Refer to inside back cover.